Search NASASearch

SEARCH · Search NASA

Results for “phase shifting interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Surface Figure Measurement at 20K: Silicon Carbide and Cesic Mirrors

This report presents the facility, methods, and results of testing cryogenically-cooled spherical mirrors, using standard phase-shifting interferometry, at the Goddard Space Flight Center (GSFC). Two mirrors were supplied to GSFC by the European Space Technology Center, so that GSFC could render a second, independent cryo-measurement of their surface figures at 20K. These mirrors, produced by Galileo Avionica and its partners, demonstrate the technology of silicon carbide and SiC-composite lightweighted mirrors, designed for high accuracy (10 nm rms surface figure error) at both room temperature and 20K. The two mirrors provided for testing at GSFC include one made of sintered silicon carbide (mirror blank by Bettini), and a second made of the C/Si/SiC composite known as Cesic (supplied by ECM). Both mirrors are f/2 spheres with 150 mm clear aperture, and with integral mounts. At GSFC, the mirrors will be measured first at at room temperature, making use of standard techniques, with a predicted uncertainty of 2 nm. Then each mirror will be tested in the cryostat, down to 20K: first freely supported and, second, mounted to a Cesic plate that models a Cesic optical bench. The uncertainty of the resultant surface figure error is predicted to be about 5 nm rms. Details of the uncertainty budget are discussed in a related poster. GSFC's techniques and results can be usefully compared to the measurements performed on the same two mirrors by and for Galileo Avionica, who used a somewhat different test configuration and alignment approach.

Blake, Peter

High-Accuracy Surface Figure Measurement of Silicon Mirrors at 80 K

This report describes the equipment, experimental methods, and first results at a new facility for interferometric measurement of cryogenically-cooled spherical mirrors at the Goddard Space Flight Center Optics Branch. The procedure, using standard phase-shifting interferometry, has an standard combined uncertainty of 3.6 nm rms in its representation of the two-dimensional surface figure error at 80, and an uncertainty of plus or minus 1 nm in the rms statistic itself. The first mirror tested was a concave spherical silicon foam-core mirror, with a clear aperture of 120 mm. The optic surface was measured at room temperature using standard absolute techniques; and then the change in surface figure error from room temperature to 80 K was measured. The mirror was cooled within a cryostat. and its surface figure error measured through a fused-silica window. The facility and techniques will be used to measure the surface figure error at 20K of prototype lightweight silicon carbide and Cesic mirrors developed by Galileo Avionica (Italy) for the European Space Agency (ESA).

Blake, Peter

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.

Feynman diagrams for matter wave interferometry

We introduce a new theoretical framework based on Feynman diagrams to compute phase shifts in matter wave interferometry. The method allows for analytic computation of higher order quantum corrections, beyond the traditional semi-classical approximation. These additional terms depend on the finite size of the initial matter wavefunction and/or have higher order dependence on ℏ. We apply the method to compute the response of matter wave interferometers to power law potentials and potentials with an arbitrary spatial dependence. The analytic expressions are validated by comparing to numerical simulations, and estimates are provided for the scale of the quantum corrections to the phase shift response to the gravitational field of the earth, anharmonic trapping potentials, and gravitational fields from local proof masses. We also find that for certain experimentally feasible parameters, these corrections are large enough to be measured and could lead to systematic errors if they are not mitigated. We find that to first order in a spatially dependent potential, quantum corrections vanish when the initial matter wavepacket has spherical symmetry and the potential satisfies Laplace's equation. We anticipate these quantum corrections will be especially important for trapped matter wave interferometers and for free-space matter wave interferometers in the presence of proof masses. These interferometers are becoming increasingly sensitive tools for mobile inertial sensing, gravity surveying, tests of gravity and its interplay with quantum mechanics, and searches for dark energy.

Glick, Jonah [Northwestern U.; Fermilab] (ORCID:00

Information retrieval from holographic interferograms: Fundamentals and problems

Holographic interferograms can contain large amounts of information about flow and temperature fields. Their information content can be very high because they can be viewed from many different directions. This multidirectionality, and fringe localization add to the information contained in the fringe pattern if diffuse illumination is used. Additional information, and increased accuracy can be obtained through the use of dual reference wave holography to add reference fringes or to effect discrete phase shift or hetrodyne interferometry. Automated analysis of fringes is possible if interferograms are of simple structure and good quality. However, in practice a large number of practical problems can arise, so that a difficult image processing task results.

Vest, Charles M.

Step Bunch Evolution on Vicinal Faces of KDP

For in-situ studies of the formation and evolution of step patterns in solution growth, we have assembled an experimental setup based on Michelson interferometry with the growing crystal surface as one of the reflective surfaces. The device allows data collection over a relatively large area (approximately 4 sq. mm) in situ and in real time during growth. The depth resolution is improved over traditional interferometry using phase-shifted images combining by a suitable algorithm. We achieve a depth resolution of approximately 50 Angstroms. Lateral resolution, dependent on the degree of magnification, is around 0.3 to 5 microns. The crystal chosen as a model in this work is potassium dihydrogen phosphate (KDP), the optically non-linear material widely used in frequency doubling applications. Kinetics of KDP crystallization is well studied so that KDP can serve as a benchmark for our investigations. We present quantitative results on the onset, initial stages and development of instabilities in moving step trains on vicinal crystal surfaces at varying supersaturation, flow rate, and flow direction. The kinetics data suggest that at low supersaturations, step bunching is caused by impurity retardation of the steps, while at higher supersaturations, we link the non-linearity during growth to interdependence of the velocity and density of the steps evidenced in independent experiments. The behavior on the surface is very dynamic, small bunches both merge and split from larger bunches as they travel across the facet. We present evidence that despite these dynamics, under steady conditions there exists a limiting value to step bunch height. This height is reached at distances between 600 and 1000 microns from the step source. In our experiments, we observed the retention of this step bunch height limit up to the path of 1500 microns.

Booth, N. A.

Wide-Field InfraRed Survey Telescope (WFIRST) Slitless Spectrometer: Design, Prototype, and Results

The slitless spectrometer plays an important role in the Wide-Field InfraRed Survey Telescope (WFIRST) mission for the survey of emission-line galaxies. This will be an unprecedented very wide field, HST quality 3D survey of emission line galaxies. The concept of the compound grism as a slitless spectrometer has been presented previously. The presentation briefly discusses the challenges and solutions of the optical design, and recent specification updates, as well as a brief comparison between the prototype and the latest design. However, the emphasis of this paper is the progress of the grism prototype: the fabrication and test of the complicated diffractive optical elements and powered prism, as well as grism assembly alignment and testing. Especially how to use different tools and methods, such as IR phase shift and wavelength shift interferometry, to complete the element and assembly tests. The paper also presents very encouraging results from recent element tests to assembly tests. Finally we briefly touch the path forward plan to test the spectral characteristic, such as spectral resolution and response.

Grism

Phase Shift Interferometer and Growth Set Up to Step Pattern Formation During Growth From Solutions. Influence of the Oscillatory solution Flow on Stability

We have assembled an experimental setup based on Michelson interferometry with the growing crystal surface as one of the reflective surfaces. The crystallization part of the device allows optical monitoring of a face of a crystal growing at temperature stable within 0.05 C in a flow of solution of controlled direction and speed. The reference arm of the interferometer contains a liquid crystal element that allows controlled shifts of the phase of the interferograms. We employ an image-processing algorithm, which combines five images with a pi/2 phase difference between each pair of images. The images are transferred to a computer by a camera capable of capturing 60 frames per second. The device allows data collection on surface morphology and kinetics during the face layers growth over a relatively large area (approximately 4 sq. mm) in situ and in real time during growth. The estimated depth resolution of the phase shifting interferometry is approximately 50 Angstroms. The data will be analyzed in order to reveal and monitor step bunching during the growth process. The crystal chosen as a model for study in this work is KH2PO4 (KDP). This optically non-linear material is widely used in frequency doubling applications. There have been a number of studies of the kinetics of KDP crystallization that can serve as a benchmark for our investigations. However, so far, systematic quantitative characteristics of step interaction and bunching are missing. We intend to present our first quantitative results on the onset, initial stages and development of instabilities in moving step trains on vicinal crystal surfaces at varying supersaturation, flow rate, and flow direction. Behavior of a vicinal face growing from solution flowing normal to the steps and periodically changing its direction in time was considered theoretically. It was found that this oscillating flow reduces both stabilization and destabilization effects resulted from the unidirectional solution flow directed up the step stream and down the step stream. This reduction of stabilization and destabilization comes from effective mixing which entangles the phase shifts between the spatially periodic interface perturbation and the concentration wave induced by this perturbation. Numerical results and simplified mixing criterion will be discussed.

Chernov, Alex A.

LISA Mission Concept Study, Laser Interferometer Space Antenna for the Detection and Observation of Gravitational Waves

This document presents the results of a design feasibility study for LISA (Laser Interferometer Space Antenna). The goal of LISA is to detect and study low-frequency astrophysical gravitational radiation from strongly relativistic regions. Astrophysical sources potentially visible to LISA include extra-galactic massive black hole binaries at cosmological distances, binary systems composed of a compact star and a massive black hole, galactic neutron star-black hole binaries, and background radiation from the Big Bang. The LISA mission will comprise three spacecraft located five million kilometers apart forming an equilateral triangle in an Earth-trailing orbit. Fluctuations in separation between shielded test masses located within each spacecraft will be determined by optical interferometry which determines the phase shift of laser light transmitted between the test masses.

Folkner, W. M.

Phase-Compensating System For Fiber-Optic Holography

Phase-compensating system controls relative phase of laser light emitted from two optical fibers. Stabilized for conventional holographic applications, or stepped through sequence of 90 degree phase shifts for phase-stepping holographic interferometry. Closed-loop system compensates for phase fluctuations caused by mechanical stresses and temperature changes in fibers, providing long-term phase stability and phase steps accurate to within 0.02 degrees. Controls environmental fluctuations in phases of light emitted by output fibers.

Mercer, Carolyn R.

$Z$-Pinch Interferometry Analysis With the Fourier-Based TNT Code

Here, we present the analysis of interferometry diagnostics with the user-friendly Talbot Numerical Tool (TNT), a Fourier-based postprocessing code that enables real-time assessment of plasma systems. TNT performance was explored with visible and infrared interferometry in pulsed-power-driven Z -pinch configurations to expand its capabilities beyond Talbot X-ray interferometry in the high-intensity laser environment. TNT enabled accurate electron density characterization of magnetically driven plasma flows and shocks through phase-retrieval methods that did not require data modification or masking. TNT demonstrated enhanced resolution, detecting below 4 % fringe shift, which corresponds to 8.7 × 10 15 cm –2 within 28 μ m, approaching the laser probing system limit. TNT was tested against a well-known interferometry analysis software, delivering an average resolving power nearly ten times better (~28 μ m versus ~ 210 μ m) when resolving plasma ablation features. TNT demonstrated higher sensitivity when probing sharp electron density gradients in supersonic shocks. A maximum electron areal density of 4.1 × 10 17 cm –2 was measured in the shocked plasma region, and a minimum electron density detection of ~ 1.0 × 10 15 cm –2 was achieved. When probing colliding plasma flows, the calculations of the effective adiabatic index and the associated errors were improved from γ* = 2.6 ± 1.6 – 1.4 ± 0.2 with TNT postprocessing, contributing valuable data for the interpretation of radiative transport. Additional applications of TNT in the characterization of pulsed-power plasmas and beyond are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

An optical study of grain formation: Casting and solidification technology (2-IML-1)

By studying the unidirectional growth of a metal-model material in microgravity, an attempt is made to characterize alloy solidification. Using holograms and supporting temperature measurements obtained during processing in the Fluids Experiment System (FES), the solute and thermal fields associated with the dendrite growth front and extraneous nucleation will be measured and compared to a theoretical (computational) model. Ground based supporting experiments include particle tracking to measure the velocity fields, and optical phase shift techniques (confocal optical signal processing, interferometry, and Schlieren) to study thermal and solutal fields.

Mccay, Mary H.

Numerical simulation of solar wind density fluctuations and their effects on VLF radio interferometry

A mission consisting of an array of small satellites has been proposed to investigate radio sources at frequencies from approximately 2 to 20 MHz, a range unobservable from the ground because of ionospheric absorption and aberrations. Such a mission seems feasible and relatively inexpensive, but further investigation is still necessary. The solar wind is a major concern because it contains turbulence-induced random density variations that cause a fluctuating phase shift in any electromagnetic signal passing through, sometimes making radio source imaging by interferometry impossible. A numerical simulation has been developed which attempts to accurately characterize solar wind density fluctuations. Results have allowed more concrete conclusions to be drawn about observing constraints and have shown that interferometric imaging at radio frequencies below 10 MHz with baselines up to 100 km is possible at solar elongation angles of about 90 deg or more.

Williamson, Robert S., III

4D PhaseCam(Trade Mark) Capabilities: Modal Analysis and Multiple-Wavelength Mirror Phasing

The PhaseCam is a dynamic phase shifting interferometer system manufactured by 4D Technology Corporation that is capable of very fast data acquisition. This rapid acquisition extends the capability of conventional interferometry to enable measurement in unstable environments, the generation of phase movies of surface shape and to facilitate modal analysis of structures. The PhaseCam hardware and software have been modified for MSFC to include synchronous modal optical measurement and analysis. These modifications will be discussed and data presented. The dynamic range of a phase shifting measurement is limited by local slope and pixel sampling to lambda/4 wave steps. Two-wavelength techniques can increase the effective measurement wavelength from microns to tens of centimeters and permit the phasing of mirror segments. A two wavelength PhaseCam will be discussed and measurement results presented.

Millerd, James E.

Achieving a near-ideal silicon crystal neutron interferometer using submicrometer fabrication techniques

Perfect-crystal neutron interferometry, which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degree of dimensional tolerance as well as being relatively defect-free with minimal internal stresses. In the past, perfect-crystal neutron interferometers have been produced by a two-step process. First, a resin diamond wheel would be used to remove excess material and shape the interferometer. Afterword, the crystal would be etched to remove surface defects and elevate strains. This process has had limitations in terms of repeatability and in maximizing the final contrast, or fringe visibility, of the interferometer. We have tested various fabrication and post-fabrication techniques on a single perfect-crystal neutron interferometer and measured the interferometer's performance at each step. Here we report a robust, nonetching fabrication process with high final contrast. For the interferometer used in this work, we achieved contrasts of greater than 90% several times and ultimately finished with an interferometer that has 92% contrast and a uniform phase distribution. Published by the American Physical Society 2024

Huber, M. G. (ORCID:0000000237958445)

The Effects of LOX Post Biasing on SSME Injector Wall Compatibility

An experimental investigation has been carried out to examine the effects of LOX post biasing of a shear coaxial injector on the behavior of the spray near a chamber wall. The experimental work was performed with inert propellant simulants in a high-pressure chamber. Injector flow rates and chamber pressure were designed to match the Space Shuttle Main Engine (SSME) injector gas-to-liquid density and velocity ratio at the point of propellant injection. Measurements of liquid mass flux, gas phase velocity and droplet size were made using mechanical patternation and phase Doppler interferometry techniques. The measurements revealed that the liquid mass flux distribution shifts away from the wall with increasing LOX post bias away from the wall. The shift in the liquid flux distribution was much greater than that caused by the angling of the LOX post alone. Gas velocity near the wall simultaneously increased with increasing LOX post bias away from the wall. The increase in wall side gas velocity was due to the higher fraction of gas injected on the wall side of the injector as a result of the eccentricity at the injector exit. The net result is a decrease in mixture ratio near the wall. Estimates of heat transfer and engine performance relative to the unbiased case are presented.

Strakey, P. A.

Broadband Achromatic Phase Shifter for a Nulling Interferometer

Nulling interferometry is a technique for imaging exoplanets in which light from the parent star is suppressed using destructive interference. Light from the star is divided into two beams and a phase shift of radians is introduced into one of the beams. When the beams are recombined, they destructively interfere to produce a deep null. For monochromatic light, this is implemented by introducing an optical path difference (OPD) between the two beams equal to lambda/2, where lambda is the wavelength of the light. For broadband light, however, a different phase shift will be introduced at each wavelength and the two beams will not effectively null when recombined. Various techniques have been devised to introduce an achromatic phase shift a phase shift that is uniform across a particular bandwidth. One popular technique is to use a series of dispersive elements to introduce a wavelength-dependent optical path in one or both of the arms of the interferometer. By intelligently choosing the number, material and thickness of a series of glass plates, a nearly uniform, arbitrary phase shift can be introduced between two arms of an interferometer. There are several constraints that make choosing the number, type, and thickness of materials a difficult problem, such as the size of the bandwidth to be nulled. Several solutions have been found for bandwidths on the order of 20 to 30 percent (Delta(lambda)/lambda(sub c)) in the mid-infrared region. However, uniform phase shifts over a larger bandwidth in the visible regime between 480 to 960 nm (67 percent) remain difficult to obtain at the tolerances necessary for exoplanet detection. A configuration of 10 dispersive glass plates was developed to be used as an achromatic phase shifter in nulling interferometry. Five glass plates were placed in each arm of the interferometer and an additional vacuum distance was also included in the second arm of the interferometer. This configuration creates a phase shift of pi radians with an average error of 5.97 x 10(exp -8) radians and standard deviation of 3.07 x 10(exp -4) radians. To reduce ghost reflections and interference effects from neighboring elements, the glass plates are tilted such that the beam does not strike each plate at normal incidence. Reflections will therefore walk out of the system and not contribute to the intensity when the beams are recombined. Tilting the glass plates, however, introduces several other problems that must be mitigated: (1) the polarization of a beam changes when refracted at an interface at non-normal incidence; (2) the beam experiences lateral chromatic spread as it traverses multiple glass plates; (3) at each surface, wavelength- dependent intensity losses will occur due to reflection. For a fixed angle of incidence, each of these effects must be balanced between each arm of the interferometer in order to ensure a deep null. The solution was found using a nonlinear optimization routine that minimized an objective function relating phase shift, intensity difference, chromatic beam spread, and polarization difference to the desired parameters: glass plate material and thickness. In addition to providing a uniform, broadband phase shift, the configuration achieves an average difference in intensity transmission between the two arms of the interferometer of 0.016 percent with a standard deviation of 3.64 x 10(exp -4) percent, an average difference in polarization between the two arms of the interferometer of 5.47 x 10(exp -5) percent with a standard deviation of 1.57 x 10(exp -6) percent, and an average chromatic beam shift between the two arms of the interferometer of -47.53 microns with a wavelength-by-wavelength spread of 0.389 microns.

Bolcar, Matthew R.