Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase-contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Microscopy of Analogs for Martian Dust and Soil

The upcoming Mars 2001 lander will carry an atomic force microscope (AFM) as part of the Mars Environmental Compatibility Assessment (MECA) payload. By operating in a tapping mode, the AFM is capable of sub-nanometer resolution in three dimensions and can distinguish between substances of different compositions by employing phase-contrast imaging. Phase imaging is an extension of tapping-mode AFM that provides nanometer-scale information about surface composition not revealed in the topography. Phase imaging maps the phase of the cantilever oscillation during the tapping mode scan, hence detecting variations in composition, adhesion, friction, and viscoelasticity. Because phase imaging highlights edges and is not affected by large-scale height differences, it provides for clearer observation of fine features, such as grain edges, which can be obscured by rough topography. To prepare for the Mars 01 mission, we are testing the AFM on a lunar soil and terrestrial basaltic glasses to determine the AFMOs ability to define particle shapes and sizes and grain-surface textures. The test materials include the Apollo 17 soil 79221, which is a mixture of agglutinates, impact and volcanic beads, and mare and highland rock and mineral fragments. The majority of the lunar soil particles are less than 100 microns in size, comparable to the sizes estimated for Martian dust. The terrestrial samples are millimeter size basaltic glasses collected on Black Pointe at Mono Lake, just north of the Long Valley caldera in California. The basaltic glass formed by a phreatomagmatic eruption 13,000 years ago beneath a glacier that covered the Mono Lake region. Because basaltic glass formed by reworking of pyroclastic deposits may represent a likely source for Martian dunes, these basaltic glass samples represent plausible analogs to the types of particles that may be studied in sand dunes by the 01 lander and rover. We have used the AFM to examine several different soil particles at various resolutions. The instrument has demonstrated the ability to identify parallel ridges characteristic of twinning on a 150-micron plagioclase feldspar particle. Extremely small (10-100 nanometer) adhering particles are visible on the surface of the feldspar grain, and appear elongate with smooth surfaces. Phase contrast imaging of the nanometer particles shows several compositions to be present. When the AFM was applied to a 100-micron glass spherule, it was possible to define an extremely smooth surface.E Also visible on the surface of the glass spherule were chains of 100-nanometer- and-smaller impact melt droplets. Additional information is contained in the original extended abstract.

Anderson, M. A.↗

Methods, systems, and computer-readable storage media for enhanced phase-contrast x-ray imaging

Systems and methods that directly image attenuation-based object grid, use a source grid to improve imaging of the object grid using a high-energy polychromatic source, and use a detector grid having gratings oriented substantially orthogonally to that of the object grid, can address artifacts and beam hardening effects that limit the quality and discriminatory power of high-energy x-ray imaging that includes phase contrast.

Miller, Erin A.↗

Characterizing the microstructures of mammalian enamel by synchrotron phase contrast microCT

The enamel of mammalian teeth is a highly mineralized tissue that must endure a lifetime of cyclic contact and is inspiring the development of next-generation engineering materials. Attempts to implement enamel-inspired structures in synthetic materials have had limited success, largely due to the absence of a detailed understanding of its microstructure. Here, the present work used synchrotron phase-contrast microCT imaging to evaluate the three-dimensional microstructure of enamel from four mammals including Lion, Gray Wolf, Snow Leopard, and Black Bear. Quantitative results of image analysis revealed that the decussation pattern of enamel consists of discrete diazone (D) and parazone (P) bands of rods organized with stacking arrangement of D+/P/D-/P in all mammals evaluated; the D+ and D- refer to distinct diazone bands with juxtaposed rod orientations from the reference plane. Furthermore, the rod orientations in the bands can be described in terms of two principal angles, defined here as the pitch and yaw. While the pitch angle increases from the outer enamel to a maximum (up to ≈ 40°) near the dentin enamel junction, minimal spatial variations are observed in yaw across the enamel thickness. There are clear differences in the decussation parameters of enamel across species that are interpreted here with respect to the structural demands placed on their teeth. The rod pitch and band width of enamel are identified as important design parameters and appear to be correlated with the bite force quotient of the four mammals evaluated.

36 MATERIALS SCIENCE↗

Single-distance nano-holotomography with coded apertures

High-resolution phase-contrast 3D imaging using nano-holotomography typically requires collecting multiple tomograms at varying sample-to-detector distances, usually 3 to 4. This multi-distance approach limits temporal resolution, making it impractical for operando studies. Moreover, shifting the sample complicates reconstruction, requiring precise alignment, registration, and interpolation to correct for shift-dependent magnification on the detector. In response, we propose and validate through simulations a novel, to the best of our knowledge, single-distance approach that leverages coded apertures to structure beam illumination while the sample rotates. Finally, this approach relies on a joint reconstruction scheme, which integrates phase retrieval with 3D tomography, ensuring data consistency and achieving artifact-free reconstructions from a single distance, unlocking dynamic experiments.

Nikitin, Viktor [Argonne National Laboratory (ANL)↗

Intracranial Effects of Artificial Gravity: A 3T MRI Study

INTRODUCTION Spaceflight associated neuro-ocular syndrome (SANS) is characterized by the development of optic disc edema, posterior globe flattening, choroidal/retinal folds and hyperopic refractive errors1. SANS is hypothesized to be a result of headward fluid shifts that invariably occurs in the microgravity environment. As a countermeasure, artificial gravity (AG) through centrifugation has been proposed to reduce this headward fluid shift, however there is no current proof of benefit. The goal of this study was to determine if the application of AG can prevent or reduce known changes in brain volumetry, internal carotid artery (ICA) stroke volume and cerebral spinal fluid (CSF) flow velocity that occurs during simulated chronic headward fluid shift using head down tilt bed rest (HDTBR) methodology2 as an indicator of countermeasure efficacy. METHODS Healthy volunteers were recruited for an IRB approved HDTBR study performed at the German Aerospace Center in Cologne, Germany. Strict six-degree HDTBR was used as a spaceflight analog to induce a continuous headward fluid shift. HDTBR was carried out for 60 days for all subjects. Short-arm centrifugation was utilized to generate AG equating to ~0.3g of acceleration at the level of the eye. The subjects were divided equally into three groups: NoAG (control; n=8), daily intermittent AG (6 x 5 min iAG; n=8), and daily continuous 30 min (cAG; n=8). All studies were performed on a single dedicated 3T MRI Scanner. Pulse-gated MRI phase-contrast flow imaging was used to quantify ICA stroke volume and peak-to-peak CSF flow velocity in the mid cerebral aqueduct. 3D-SPGR was acquired for volumetric segmentation of the brain and CSF spaces. MRI acquisitions were obtained at baseline (BDC), 14 days into HDTBR (HDTBR14), 52 days into HDTBR (HDTBR52) and 3-5 days after HDTBR (recovery, R+3/5).The data were analyzed by the mixed model, which included intervention and time (BDC, HDTBR 14, HDTBR 52, R+3/5) as the fixed effects and included subject as the random effect.RESULTS24 healthy subject volunteers (16 men, 8 women, mean age = 33 years ± 9 [standard deviation] and mean BMI = 24.3 kg/m2 ± 2.0) successfully completed all phases of the study. Strict six-degree HDTBR was characterized by progressive and statistically significant (p<.01) increases in mean combined brain and CSF volumes and mean aqueductal CSF peak-to-peak flow velocity, as well as statistically significant (p<.01) progressive decrease in mean ICA stroke volume from baseline to 52 days post intervention (Figs. 1-3). Compared to baseline, only combined brain and CSF volumes did not return to baseline values in the recovery period (p=NS). Neither iAG nor cAG exerted any significant effects on the measured MRI brain parameters as compared to HDTBR alone (p=NS). CONCLUSION Our results indicate that HDTBR at 6-degrees was effective in producing alterations in ICA stroke volume, aqueductal CSF flow velocity, and combined brain and CSF volumetric change that is associated with chronic headward fluid shift. Short duration, 30-min daily exposure to either iAG or cAG appears to be insufficient in preventing or reducing the effects of chronic HDTBR and thus may not be a suitable countermeasure as currently deployed. AG protocol modifications, including increased duration and magnitude of exposure, should be considered for future research.

L A Kramer↗

Intracranial Effects of Intermittent Lower Body Negative Pressure with Head Down Tilt Bed Rest: Comparison to Upright Posture

INTRODUCTION Spaceflight-associated neuro-ocular syndrome (SANS) affects a majority of astronauts during long-duration spaceflight. SANS is hypothesized to result from an unrelenting headward fluid shift that occurs in the microgravity environment. Altered intracranial structure and physiology documented in spaceflight and head-down tilt (HDT) experiments(1, 2) are also theorized to be related to chronic headward fluid shift and thereby can provide an independent quantitative assessment related to this mechanism. As a potential countermeasure, lower body negative pressure (LBNP) applied in the supine posture has shown efficacy in reducing headward fluid shift(3). However, it remains unknown if intermittent LBNP simulating daily upright posture fluid redistribution can mitigate SANS and intracranial changes associated with long-duration spaceflight. The goal of this study was to quantify the effects of daily application of LBNP or daily exposure to the upright posture on intracranial structure and physiology during long-term HDT in order to evaluate the potential efficacy of LBNP as a countermeasure to SANS. METHODS 22 healthy volunteers (11 men; 11 women; mean age = 35 years (SD=9.2)(age range = 24 to 52 years); mean BMI = 24.0 kg/m2 (SD=2.8)) completed an MRI study performed at the German Aerospace Facility in Cologne, Germany. Strict six-degree head-down tilt (HDT) bedrest was used as a spaceflight analog to induce a continuous headward fluid shift for 30 days. The subjects were divided equally into two groups of interventions: 1) LBNP for 3-hour sessions twice daily and 2) seated position for 3-hour sessions twice daily. Interventions were divided into morning and afternoon sessions for both groups. The LBNP intervention was maintained at 25 mmHg  2 mmHg. Pulse-gated MRI phase-contrast flow imaging was used to quantify cerebral artery stroke volume (CASV) and peak-to-peak cerebral spinal fluid (CSF) velocity (CSFVp-p) within the cerebral aqueduct. A 3D T1-MPRAGE sequence was used to quantify volumetric changes of the brain and intracranial CSF spaces using MRI Cloud software. MRI acquisitions were obtained at baseline (BDC, supine posture), 15 days into HDT (HDT15), 29 days into HDT (HDT29), and 12 days after recovery (R12, supine posture). The data were analyzed by a mixed model, which included intervention, time (four nominal levels BDC, HDT15, HDT29, R12), and intervention-time interaction as the fixed effects and included subject as a random effect. RESULTS Compared to BDC there was no statistically significant difference in CASV and CSFVp-p during HDT except for CASV at HDT29 (seated group) where there was a 1.7 mL (12%) decrease (P<0.01). Compared to BDC there was a statistically significant increase in intracranial volume (ICV; ICV = white matter + gray matter + CSF) for both interventions at HDT15 (Δ13 mL, 0.9 % (LBNP group); Δ15 mL, 1.0%, (seated group)) and HDT29 (Δ19 mL, 1.2%, (LBNP group); Δ23 mL, 1.5%) (seated group)) (All Ps<.001). Compared to baseline, lateral ventricular volume increased at HDT15 (Δ0.9 mL, 5.5%) and HDT29 (Δ1.8 mL, 10%)) for LBNP only (P=.001 for each). During HDT, white matter volume remained stable compared to baseline for both interventions. There were no significant intervention effects in the overall response to HDT (All Ps >.2). CONCLUSION LBNP had a similar response to the seated posture during 29 days of HDT. Although there was an increase in ICV and lateral ventricular volume with HDT there was no change in intracranial physiological parameters with LBNP suggesting an overall diminished response to the long-term effects of HDT. The lack of any significant increase in white matter volume during HDT with LBNP suggests maintenance of cerebral interstitial fluid transport. Final conclusions are pending the data collection for the control group (no intervention) which will be completed in 2023.

Larry A Kramer↗

Coded-mask-based X-ray phase-contrast and dark-field imaging

Phase contrast and dark-field X-ray imaging enable imaging of objects that absorb or reflect very little X-ray light. Disclosed is a method and systems for performing coded-mask-based multi-contrast imaging (CMMI). The method includes providing radiation to a coded mask that has a known phase and absorption profile according to a pre-determined pattern. The radiation is then impingent upon a sample, and the radiation is detected to perform phase-reconstruction and image processing. The method and associated systems allow for the use of maximum-likelihood and machine learning methods for reconstruction images of the sample from the detected radiation.

Shi, Xianbo↗

Diffraction and imaging study of imperfections of crystallized lysozyme with coherent X-rays

Phase-contrast X-ray diffraction imaging and high-angular-resolution diffraction combined with phase-contrast radiographic imaging were employed to characterize defects and perfection of a uniformly grown tetragonal lysozyme crystal in the symmetric Laue case. The full-width at half-maximum (FWHM) of a 4 4 0 rocking curve measured from the original crystal was approximately 16.7 arcsec and imperfections including line defects, inclusions and other microdefects were observed in the diffraction images of the crystal. The observed line defects carry distinct dislocation features running approximately along the <1 1 0> growth front and have been found to originate mostly in a central growth area and occasionally in outer growth regions. Inclusions of impurities or formations of foreign particles in the central growth region are resolved in the images with high sensitivity to defects. Slow dehydration led to the broadening of a fairly symmetric 4 4 0 rocking curve by a factor of approximately 2.6, which was primarily attributed to the dehydration-induced microscopic effects that are clearly shown in X-ray diffraction images. The details of the observed defects and the significant change in the revealed microstructures with drying provide insight into the nature of imperfections, nucleation and growth, and the properties of protein crystals.

Muramidase/chemistry↗

Multi-slice electron ptychographic tomography for three-dimensional phase-contrast microscopy beyond the depth of focus limits

Electron ptychography is a powerful computational method for atomic-resolution imaging with high contrast for weakly and strongly scattering elements. Modern algorithms coupled with fast and efficient detectors allow imaging specimens with tens of nanometers thicknesses with sub-0.5 Ångstrom lateral resolution. However, the axial resolution in these approaches is currently limited to a few nanometers, limiting their ability to solve novel atomic structures ab initio. Here, we experimentally demonstrate multi-slice ptychographic electron tomography, which allows atomic resolution three-dimensional phase-contrast imaging in a volume surpassing the depth of field limits. We reconstruct tilt-series 4D-STEM measurements of a $\mathrm{Co_3O_4}$ nanocube, yielding 2 Å axial and 0.7 Å transverse resolution in a reconstructed volume of $\mathrm{(18.2\,nm)^3}$. Our results demonstrate a 13.5-fold improvement in axial resolution compared to multi-slice ptychography while retaining the atomic lateral resolution and the capability to image volumes beyond the depth of field limit. Multi-slice ptychographic electron tomography significantly expands the volume of materials accessible using high-resolution electron microscopy. We discuss further experimental and algorithmic improvements necessary to also resolve single weakly scattering atoms in 3D.

36 MATERIALS SCIENCE↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

Tetracycline rapidly reaches all the constituent cells of uropathogenic Escherichia coli biofilms

We have developed a method for visualizing Escherichia coli cells that are exposed to tetracycline in a biofilm, based on a previous report that liposomes containing the E. coli TetR(B) protein fluoresce when exposed to this antibiotic. By our method, cells devoid of TetR(B) also exhibited tetracycline-dependent fluorescence. At 50 microg of tetracycline ml(-1), planktonic cells of a uropathogenic E. coli (UPEC) strain developed maximal fluorescence after 7.5 to 10 min of exposure. A similar behavior was exhibited by cells in a 24- or 48-h UPEC biofilm, as examined by confocal laser microscopy, regardless of whether they lined empty spaces or occupied densely packed regions. Further, a comparison of phase-contrast and fluorescent images of corresponding biofilm zones showed that all the cells fluoresced. Thus, all the biofilm cells were exposed to tetracycline and there were no pockets within the biofilm where the antibiotic failed to reach. It also appeared unlikely that niches of reduced exposure to the antibiotic existed within the biofilms.

Non-NASA Center↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Rapid in situ hybridization technique using 16S rRNA segments for detecting and differentiating the closely related gram-positive organisms Bacillus polymyxa and Bacillus macerans

A rapid, sensitive, inexpensive in situ hybridization technique, using 30-mer 16S rRNA probes, can specifically differentiate two closely related Bacillus spp., B. polymyxa and B. macerans. The 16S rRNA probes were labeled with a rhodamine derivative (Texas Red), and quantitative fluorescence measurements were made on individual bacterial cells. The microscopic fields analyzed were selected by phase-contrast microscopy, and the fluorescence imaging analyses were performed on 16 to 67 individual cells. The labeled 16S rRNA probe, POL, whose sequence was a 100% match with B. polymyxa 16S rRNA but only a 60% match with B. macerans 16S rRNA, gave quantitative fluorescence ratio measurements that were 34.8-fold higher for B. polymyxa cells than for B. macerans cells. Conversely, the labeled probe, MAC, which matched B. polymyxa 16S rRNA in 86.6% of its positions and B. macerans 16S rRNA in 100% of its positions, gave quantitative fluorescence measurements that were 59.3-fold higher in B. macerans cells than in B. polymyxa cells. Control probes, whose 16S rRNA sequence segment (P-M) was present in both B. polymyxa and B. macerans as well as a panprokaryotic probe (16S), having a 100% match with all known bacteria, hybridized equally well with both organisms. These latter hybridizations generated very high fluorescence signals, but their comparative fluorescence ratios (the differences between two organisms) were low. The control paneukaryotic probe (28S), which had less than 30% identity for both B. macerans and B. polymyxa, did not hybridize with either organism.

Non-NASA Center↗

Colour thresholding and objective quantification in bioimaging

Computer imaging is rapidly becoming an indispensable tool for the quantification of variables in research and medicine. Whilst its use in medicine has largely been limited to qualitative observations, imaging in applied basic sciences, medical research and biotechnology demands objective quantification of the variables in question. In black and white densitometry (0-256 levels of intensity) the separation of subtle differences between closely related hues from stains is sometimes very difficult. True-colour and real-time video microscopy analysis offer choices not previously available with monochrome systems. In this paper we demonstrate the usefulness of colour thresholding, which has so far proven indispensable for proper objective quantification of the products of histochemical reactions and/or subtle differences in tissue and cells. In addition, we provide interested, but untrained readers with basic information that may assist decisions regarding the most suitable set-up for a project under consideration. Data from projects in progress at Tulane are shown to illustrate the advantage of colour thresholding over monochrome densitometry and for objective quantification of subtle colour differences between experimental and control samples.

NASA Discipline Neuroscience↗

Biomolecular Analysis Capability for Cellular and Omics Research on the International Space Station

International Space Station (ISS) assembly complete ushered a new era focused on utilization of this state-of-the-art orbiting laboratory to advance science and technology research in a wide array of disciplines, with benefits to Earth and space exploration. ISS enabling capability for research in cellular and molecular biology includes equipment for in situ, on-orbit analysis of biomolecules. Applications of this growing capability range from biomedicine and biotechnology to the emerging field of Omics. For example, Biomolecule Sequencer is a space-based miniature DNA sequencer that provides nucleotide sequence data for entire samples, which may be used for purposes such as microorganism identification and astrobiology. It complements the use of WetLab-2 SmartCycler"TradeMark", which extracts RNA and provides real-time quantitative gene expression data analysis from biospecimens sampled or cultured onboard the ISS, for downlink to ground investigators, with applications ranging from clinical tissue evaluation to multigenerational assessment of organismal alterations. And the Genes in Space-1 investigation, aimed at examining epigenetic changes, employs polymerase chain reaction to detect immune system alterations. In addition, an increasing assortment of tools to visualize the subcellular distribution of tagged macromolecules is becoming available onboard the ISS. For instance, the NASA LMM (Light Microscopy Module) is a flexible light microscopy imaging facility that enables imaging of physical and biological microscopic phenomena in microgravity. Another light microscopy system modified for use in space to image life sciences payloads is initially used by the Heart Cells investigation ("Effects of Microgravity on Stem Cell-Derived Cardiomyocytes for Human Cardiovascular Disease Modeling and Drug Discovery"). Also, the JAXA Microscope system can perform remotely controllable light, phase-contrast, and fluorescent observations. And upcoming confocal microscopy capability will allow for optical sectioning of biological tissues to determine microanatomical localization of biomarkers. Furthermore, NASA's geneLAB effort addresses integration of genomic, epigenomic, transcriptomic, proteomic and metabolomic datasets, by applying an innovative open source science platform for multi-investigator high throughput utilization of the ISS. In sum, the expanding ISS capability for analysis of biomolecules is enabling innovative research in a broad spectrum of areas such as cellular and molecular biology, biotechnology, tissue engineering, biomedicine, and Omics, providing manifold benefits for humanity.

Guinart-Ramirez, Y.↗

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based X-ray microscope

With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

3D virtual histology↗

NASA Tech Briefs, October 2005

Topics covered include: Insect-Inspired Optical-Flow Navigation Sensors; Chemical Sensors Based on Optical Ring Resonators; A Broad-Band Phase-Contrast Wave-Front Sensor; Progress in Insect-Inspired Optical Navigation Sensors; Portable Airborne Laser System Measures Forest-Canopy Height; Deployable Wide-Aperture Array Antennas; Faster Evolution of More Multifunctional Logic Circuits; Video-Camera-Based Position-Measuring System; N-Type delta Doping of High-Purity Silicon Imaging Arrays; Avionics System Architecture Tool; Updated Chemical Kinetics and Sensitivity Analysis Code; Predicting Flutter and Forced Response in Turbomachinery; Upgrades of Two Computer Codes for Analysis of Turbomachinery; Program Facilitates CMMI Appraisals; Grid Visualization Tool; Program Computes Sound Pressures at Rocket Launches; Solar-System Ephemeris Toolbox; Data-Acquisition Software for PSP/TSP Wind-Tunnel Cameras; Corrosion-Prevention Capabilities of a Water-Borne, Silicone-Based, Primerless Coating; Sol-Gel Process for Making Pt-Ru Fuel-Cell Catalysts; Making Activated Carbon for Storing Gas; System Regulates the Water Contents of Fuel-Cell Streams; Five-Axis, Three-Magnetic-Bearing Dynamic Spin Rig; Modifications of Fabrication of Vibratory Microgyroscopes; Chamber for Growing and Observing Fungi; Electroporation System for Sterilizing Water; Thermoelectric Air/Soil Energy-Harvesting Device; Flexible Metal-Fabric Radiators; Actuated Hybrid Mirror Telescope; Optical Design of an Optical Communications Terminal; Algorithm for Identifying Erroneous Rain-Gauge Readings; Condition Assessment and End-of-Life Prediction System for Electric Machines and Their Loads; Lightweight Thermal Insulation for a Liquid-Oxygen Tank; Stellar Gyroscope for Determining Attitude of a Spacecraft; and Lifting Mechanism for the Mars Explorer Rover.

Source record↗

Solving complex nanostructures with ptychographic atomic electron tomography

Abstract Transmission electron microscopy (TEM) is essential for determining atomic scale structures in structural biology and materials science. In structural biology, three-dimensional structures of proteins are routinely determined from thousands of identical particles using phase-contrast TEM. In materials science, three-dimensional atomic structures of complex nanomaterials have been determined using atomic electron tomography (AET). However, neither of these methods can determine the three-dimensional atomic structure of heterogeneous nanomaterials containing light elements. Here, we perform ptychographic electron tomography from 34.5 million diffraction patterns to reconstruct an atomic resolution tilt series of a double wall-carbon nanotube (DW-CNT) encapsulating a complex ZrTe sandwich structure. Class averaging the resulting tilt series images and subpixel localization of the atomic peaks reveals a Zr 11 Te 50 structure containing a previously unobserved ZrTe 2 phase in the core. The experimental realization of atomic resolution ptychographic electron tomography will allow for the structural determination of a wide range of beam-sensitive nanomaterials containing light elements.

36 MATERIALS SCIENCE↗