Slot-Antenna/Permanent-Magnet Device for Generating Plasma

A device that includes a rectangular-waveguide/slot-antenna structure and permanent magnets has been devised as a means of generating a substantially uniform plasma over a relatively large area, using relatively low input power and a low gas flow rate. The device utilizes electron cyclotron resonance (ECR) excited by microwave power to efficiently generate plasma in a manner that is completely electrodeless in the sense that, in principle, there is no electrical contact between the plasma and the antenna. Plasmas generated by devices like this one are suitable for use as sources of ions and/or electrons for diverse material-processing applications (e.g., etching or deposition) and for ion thrusters. The absence of plasma/electrode contact essentially prevents plasma-induced erosion of the antenna, thereby also helping to minimize contamination of the plasma and of objects exposed to the plasma. Consequently, the operational lifetime of the rectangular-waveguide/ slot-antenna structure is long and the lifetime of the plasma source is limited by the lifetime of the associated charged-particle-extraction grid (if used) or the lifetime of the microwave power source. The device includes a series of matched radiating slot pairs that are distributed along the length of a plasma-source discharge chamber (see figure). This arrangement enables the production of plasma in a distributed fashion, thereby giving rise to a uniform plasma profile. A uniform plasma profile is necessary for uniformity in any electron- or ion-extraction electrostatic optics. The slotted configuration of the waveguide/ antenna structure makes the device scalable to larger areas and higher powers. All that is needed for scaling up is the attachment of additional matched radiating slots along the length of the discharge chamber. If it is desired to make the power per slot remain constant in scaling up, then the input microwave power must be increased accordingly. Unlike in prior ECR microwave plasma-generating devices, there is no need for an insulating window on the antenna. Such windows are sources of contamination and gradually become ineffective as they become coated with erosion products over time. These characteristics relegate prior ECR microwave plasma-generating devices to non-ion beam, non-deposition plasma applications. In contrast, the lack of need for an insulating window in the present device makes it possible to use the device in both ion-beam (including deposition) and electron-beam applications. The device is designed so that ECR takes place above each slot and the gradient of the magnetic field at each slot is enough to prevent backflow of plasma.

Foster, John E.↗

Plasma Diagnostics by Antenna Impedance Measurements

The impedance of an electrically short antenna immersed in a plasma provides an excellent in situ diagnostic tool for electron density and other plasma parameters. By electrically short we mean that the wavelength of the free-space electromagnetic wave that would be excited at the driving frequency is much longer than the physical size of the antenna. Probes using this impedance technique have had a long history with sounding rockets and satellites, stretching back to the early 1960s. This active technique could provide information on composition and temperature of plasmas for comet or planetary missions. Advantages of the impedance probe technique are discussed and two classes of instruments built and flown by SDL-USU for determining electron density (the capacitance and plasma frequency probes) are described.

Swenson, C. M.↗

Antenna admittance determination of electron density.

A circular-aperture flush-mounted antenna for which a theoretical description of the antenna-plasma interaction has been developed was used to obtain a comparison between theoretical and experimental antenna admittance in the presence of ionized boundary layers of low-collision frequency. The antenna was located in a flat-plate model which was in turn located in the expanding-flow environment of a reflected-shock tunnel. The electron-temperature and electron-density distributions in the plate boundary layer at the antenna location were independently measured using voltage-swept thin-wire Langmuir probes for one of the test conditions. The antenna admittance was measured using a four-probe microwave reflectometer and these measured values were found to be in good agreement with those predicted from the theory. Measurements were also performed with another type of circular-aperture antenna which did not satisfy all of the constraints of the theoretical model, although good agreement was obtained between the calculations and the experimental results.

Dunn, M. G.↗

Theoretical and experimental investigations of antennas and waves in plasma

The near field characteristics of an antenna when it is covered by a plasma sheath were investigated. The areas of investigation were: (1) current distribution, (2) input admittance, and (3) radiation pattern as functions of the electrical length of the antenna. Diagnostic measurements were also made to determine the properties of the plasma. A numerical method was evolved to solve the problem of a finite cylindrical antenna in an infinite plasma column.