Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Application of physiologically based pharmacokinetic modeling for sertraline dosing recommendations in pregnancy

Pregnancy is a period of significant change that impacts physiological and metabolic status leading to alterations in the disposition of drugs. Uncertainty in drug dosing in pregnancy can lead to suboptimal therapy, which can contribute to disease exacerbation. A few studies show there are increased dosing requirements for antidepressants in late pregnancy; however, the quantitative data to guide dose adjustments are sparse. We aimed to develop a physiologically based pharmacokinetic (PBPK) model that allows gestational-age dependent prediction of sertraline dosing in pregnancy. A minimal physiological model with defined gut, liver, plasma, and lumped placental-fetal compartments was constructed using the ordinary differential equation solver package, ‘mrgsolve’, in R. We extracted data from the literature to parameterize the model, including sertraline physicochemical properties, in vitro metabolism studies, disposition in nonpregnant women, and physiological changes during pregnancy. The model predicted the pharmacokinetic parameters from a clinical study with eight subjects for the second trimester and six subjects for the third trimester. Based on the model, gestational-dependent changes in physiology and metabolism account for increased clearance of sertraline (up to 143% at 40 weeks gestational age), potentially leading to under-dosing of pregnant women when nonpregnancy doses are used. The PBPK model was converted to a prototype web-based interactive dosing tool to demonstrate how the output of a PBPK model may translate into optimal sertraline dosing in pregnancy. Quantitative prediction of drug exposure using PBPK modeling in pregnancy will support clinically appropriate dosing and increase the therapeutic benefit for pregnant women.

60 APPLIED LIFE SCIENCES↗

Calibration and Initial Results of Space Radiation Dosimetry Using the iMESA-R

The integrated Miniaturized Electrostatic Analyzer-Reflight (iMESA-R) is a space weather instrument designed to measure plasma density, temperature, and spacecraft charging, along with total ionizing dose and dose rate. A constellation consisting of five nearly identical instruments has been designed and developed to act as science payloads hosted on-board Department of Defense satellites operating in low-Earth orbit. To validate the dosimetry component of the iMESA-R, a radiation test study was performed to calibrate the dosimeter and ascertain the attenuation due to the instrument aluminum housing. An 80 curie Cobalt-60 radioisotope source emitting beta, X-ray, and gamma ray radiation decay products was used to calibrate the dosimeter response as a function of distance and instrument shielding. We present results of the calibration study along with initial on-orbit data presented from the first operational iMESA-R hosted on-board Space Test Program Satellite 5 in a polar Earth orbit. The initial on-orbit data demonstrate the ability to map the radiation environment, particularly the South Atlantic Anomaly and the auroral regions using total ionizing dose rate due to electrons of E > 1.5 MeV and protons of E > 25 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-DNA radiosensitive targets that initiate persistent behavioral deficits in rats exposed to space radiation

Predicting future CNS risks for astronauts during deep-space missions will rely substantially on ground-based rodent data with space-relevant ions and behaviors. For rats, the accumulated evidence indicates that less densely ionizing radiation, such as 4 He and 12 C ions, induce behavior deficits at lower doses than densely ionizing ions, such as 48 Ti and 56 Fe. However, this observation conflicts with standard somatic radiobiology, in which densely ionizing ions are generally more effective than less densely ionizing ions, and where the DNA/nucleus is the accepted target for radiation-induced tumorigenesis, cytogenetic aberrations, genetic mutations, and reproductive cell death. To gain deeper insight into the subcellular nature of the radiation targets for behavior risks, we compared the effects of dose, fluence, and linear energy transfer (LET) of 4 He and 56 Fe particles using existing datasets for four distinct behavioral outcomes in rats: elevated plus maze (EPM-anxiety), novel object recognition (NOR-memory), operant responding (OR-response to environmental stimuli), and attentional set-shifting (ATSET-cognitive flexibility). We confirmed that less densely ionizing particles (except protons) showed ~100-fold lower threshold doses than densely ionizing particles for behavioral deficits (0.1–1 cGy for 4 He vs. 15–100 cGy for 56 Fe). However, when analyzed by fluence the behavioral responses converged, indicating that 4 He and 56 Fe were equally effective on a per-track basis. When analyzed by LET, there were ~100-fold differences in the LET for maximum effectiveness for behavioral deficits and DNA endpoints (~1 vs ~100 keV/μm, respectively). These unique features of radiation-induced behavioral deficits (high sensitivity to particles in the 1-keV/μm range, insensitivity to protons in the 0.2 keV/μm range, and isofluence dependence for particles with LET>1 keV/μm) provide evidence in support of a new hypothesis of sub-micron sized radiosensitive targets for behavioral effects consistent with the thickness of plasma membranes and/or small subcellular structures, smaller than a whole synapse. Like our behavior findings, mouse immature oocyte killing which is known to have a plasma membrane target was also better explained by fluence, rather than dose. In contrast, fluence analyses for DNA/nuclear endpoints in somatic cells (e.g., tumor induction, chromosome aberrations) showed opposite results, suggesting that behavior targets are not DNA. Our findings raise questions regarding the identity of subcellular targets and the multi-cellular functional unit for behavior risks, low-dose susceptibility, and generalizability from rat to other species and astronauts.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

The Preclinical Validation of 405 nm Light Parasiticidal Efficacy on Leishmania donovani in Ex Vivo Platelets in a Rag2 -/- Mouse Model

Violet–blue light of 405 nm in the visible spectrum at a dose of 270 J/cm 2 alone has been shown to be an effective microbicidal tool for inactivating several bacteria, HIV-1, and Trypanosoma cruzi in ex vivo plasma and platelets. Unlike chemical- and ultraviolet (UV)-based pathogen inactivation methods for plasma and platelet safety, 405 nm light is shown to be less toxic to host cells at light doses that are microbicidal. In this report, we evaluated the parasiticidal activity of a 405 nm light treatment on platelets spiked with the Leishmania donovani parasite. Following the light treatment, parasite viability was observed to be near zero in both low- and high-titer-spiked platelets relative to controls. Furthermore, to test the residual infectivity after inactivation in vivo, the light-treated low-titer L. donovani-spiked platelets were evaluated in an immunodeficient Rag2 -/- mouse model and monitored for 9 weeks. The parasiticidal efficacy of 405 nm light was evident from the lack of a presence of parasites in the mice spleens. Parasiticidal activity was confirmed to be mediated through 405 nm light-induced reactive oxygen species (ROS), as quantitatively measured by a 2',7'-Dichlorodihydrofluorescein diacetate (H 2 DCFDA)-based assay. Overall, these results confirm the complete inactivation of L. donovani spiked in ex vivo platelets by 405 nm light treatment and exemplify the utility of the Rag2 -/- mouse infection model for the preclinical validation of the parasiticidal efficacy of 405 nm light and this light-based technology as a potential PRT for ex vivo platelets.

405 nm light↗

Bemnifosbuvir: An HCV NS5B Inhibitor With Multiple Modes of Action

Bemnifosbuvir (BEM) is a potent, pan-genotypic inhibitor targeting the hepatitis C virus (HCV) NS5B polymerase. Its antiviral activity was evaluated in an ascending dose phase I clinical trial involving 30 patients treated once a day for 7 days. After treatment initiation, plasma HCV RNA declined in a biphasic manner with a mean reduction of 2.3 log 10 IU/mL after 24 hours and 4.4 log10 IU/mL by day 7 for the highest dose. Alanine aminotransferase (ALT) also normalized in most patients. We employed a multiscale mathematical model fitted to the HCV RNA and ALT dynamics to quantify the antiviral activity and evaluate the modes of action of BEM. We found that models in which BEM only acted as a typical HCV RNA polymerase inhibitor and reduced the intracellular production of HCV RNA did not fit the data as well as models in which BEM had multiple modes of action, including suppressing viral assembly and secretion and enhancing intracellular HCV RNA degradation. BEM's effectiveness in inhibiting intracellular HCV RNA production increased with dose (150 mg/day: 88.2%, 300 mg/day: 98.8%, 600 mg/day: 99.5%), while inhibition of viral assembly and release was ~95% effective regardless of dose. We observed a dose-dependent enhancement in the degradation of intracellular HCV RNA, with degradation rates 1.5-fold higher in patients receiving 300 mg/day and 2.7-fold higher in those receiving 600 mg/day than in patients receiving 150 mg/day. No significant differences in antiviral activity were detected between HCV genotypes 1b and 3 or between patients with and without compensated cirrhosis.

59 BASIC BIOLOGICAL SCIENCES↗

Stable and tunable MeV $$\gamma$$-ray generation via dual-laser inverse Thomson scattering from a laser-plasma accelerator

Abstract Inverse Thomson scattering from laser-plasma accelerators offers a pathway to compact, tunable MeV $$\gamma$$ -ray sources for reduced-dose radiography and enhanced performance in nuclear resonance fluorescence (NRF)-based isotope identification. However, photon yield and spectral quality are often limited by constraints on interaction geometry and scatter-laser tunability. Here we demonstrate a MeV $$\gamma$$ -ray source based on a dual-laser inverse Thomson scattering configuration driven by a 100-TW laser-plasma accelerator. Electron beams tunable from 122 to 204 MeV with $$<5$$ mrad divergence and $$<1$$ mrad pointing stability generate $$\gamma$$ rays with peak energies from 276 keV to 1.2 MeV and yields up to $$2\times 10^{7}$$ photons per shot. By independently controlling the interaction position and the scatter-pulse duration, we experimentally match the scatter pulse to the walk-off-limited interaction length. Extending the scatter pulse to 200 fs increases photon production by approximately $$15\%$$ while maintaining operation in the linear Thomson regime, thereby preserving narrow spectral bandwidth and controlled radiation divergence. Radiographic characterization demonstrates MeV-level penetration and $$\approx 0.1$$ mm spatial resolution, while stable operation is sustained over multi-hour timescales across multiple days. These results show that interaction-length optimization provides a scalable strategy for improving photon yield, spectral control, and operational stability in compact laser-plasma-accelerator-driven $$\gamma$$ -ray sources.

Tsai, Hai-En↗

Arsenic Exposure Causes Global Changes in the Metalloproteome of Escherichia coli

Arsenic is a toxic metalloid with differential biological effects, depending on speciation and concentration. Trivalent arsenic (arsenite, AsIII) is more toxic at lower concentrations than the pentavalent form (arsenate, AsV). In E. coli, the proteins encoded by the arsRBC operon are the major arsenic detoxification mechanism. Our previous transcriptional analyses indicate broad changes in metal uptake and regulation upon arsenic exposure. Currently, it is not known how arsenic exposure impacts the cellular distribution of other metals. This study examines the metalloproteome of E. coli strains with and without the arsRBC operon in response to sublethal doses of AsIII and AsV. Size exclusion chromatography coupled with inductively coupled plasma mass spectrometry (SEC-ICPMS) was used to investigate the distribution of five metals (56Fe, 24Mg, 66Zn, 75As, and 63Cu) in proteins and protein complexes under native conditions. Parallel analysis by SEC-UV-Vis spectroscopy monitored the presence of protein cofactors. Together, these data reveal global changes in the metalloproteome, proteome, protein cofactors, and soluble intracellular metal pools in response to arsenic stress in E. coli. This work brings to light one outcome of metal exposure and suggests that metal toxicity on the cellular level arises from direct and indirect effects.

59 BASIC BIOLOGICAL SCIENCES↗

Estimation Methodology to Evaluate Hypothetical Downwind Impacts from Fusion Plants

The continuing move toward establishing fusion systems for power generation and the associated research to that end is prompting examination of the potential health and safety impacts of such plants to the environment and human health. As many fusion facilities will have tritium inventories on site as part of the fusion fuel, evaluating the potential for downwind impacts from fusion facilities or power plants resulting from accident or routine emissions is a general requirement for assessing location and impacts to workers and the public. As part of siting considerations and permitting, the fusion facilities would be evaluated for potential for downwind concentration and dose impacts. For accident assessment scenarios, the downwind impacts are usually modeled as an instantaneous (or near-instantaneous) release of material transported following the wind. A range of meteorological conditions are usually assessed to determine a bounding case which results in a dose exceeding a specified threshold (e.g., 95 th or 99 th percentile; DOE 2015). This report provides initial estimates of the downwind dose impacts from a potential tritium release at a fusion power plant-relevant facility and identifies potential distances required to limit impacts to nearby population. This effort is meant to provide a bounding analysis and theoretical understanding of impacts of tritium releases for facilities subject to various environmental and atmospheric conditions. Using a Gaussian dispersion model to simulate a brief plume, downwind concentration and dose is projected for tritium oxide. Releases are assumed to consist entirely of tritium oxide due to the increased dose impacts from the oxide form relative to the elemental form of tritium. We also briefly identify how climatological conditions could potentially be used to support risk profile determination.

54 ENVIRONMENTAL SCIENCES↗

Accelerating plasma and radiation surface science using transient grating spectroscopy

A facility for the investigation of in situ radiation-materials and plasma-materials interaction is demonstrated with tungsten, using transient grating spectroscopy as a probe of thermal diffusivity and surface acoustic wave speed. Helium plasma exposure at 645 °C to 1.18 × 10 18 cm −2 helium, until the growth of tungsten fuzz, showed an increase in surface acoustic wave speed at the near-surface from 2542 ± 1 m s −1 up to 2565 ± 1 m s −1 , followed by a greater drop to 2499 ± 7 m s −1 . No observable change in thermal diffusivity was present for plasma exposure alone. A separate 10.26 MeV self-ion-irradiation of tungsten to a dose of 7.92 dpa showed a reduction in both thermal diffusivity from 61.4 ± 1.4 mm 2 s −1 to 36.0 ± 0.7 mm 2 s −1 , following trends seen in existing studies, and surface acoustic wave speed from 2647.8 ± 0.6 m s −1 to 2640.0 ± 0.4 m s −1 . Facilities like these are poised to rapidly close critical knowledge gaps regarding the coupled effects of plasma and radiation damage for materials in fusion systems.

Accelerated plasmas↗

Shutdown dose rate analysis with the Shift Monte Carlo radiation transport code and modular verification workflow

Calculation of the shutdown dose rate is crucial for safe fusion reactor operations. The Rigorous-two-step (R2S) method is a method that requires connected neutron transport, activation, and gamma transport. Shift has integrated variance reduction with a deterministic solver Denovo, supports multiple geometry formats, and is scalable. These features make it an attractive transport solver choice for an R2S workflow. An R2S workflow for the Shift Monte Carlo code is developed and compared to the existing Oak Ridge National Laboratory Shutdown Dose Rate Code Suite (ORCS) workflow. Also, a Python framework for integrating two R2S workflows is developed to mix and match each step in the R2S workflow for improved collaboration and verification experience. In this study, results show that the Shift-Denovo R2S workflow and the ORCS workflow calculate the shutdown dose rate of the ITER Shutdown Dose Rate benchmark problem with an average relative error of 2.285%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of the Utility of the Oral Fluid and Plasma Proteome for Hydrocodone Usage

Non-medical use and abuse of prescription opioids is a growing problem in both the civilian and military communities, with minimal technologies for detecting hydrocodone use. This study explored the proteomic changes that occur in the oral fluid and blood plasma following controlled hydrocodone administration in twenty subjects. The global proteomic profile was determined for samples taken at four time points per subject of pre-exposure and 4, 6, or 168 hours post-exposure. The oral fluid samples analyzed herein provided greater differentiation between “baseline” and “response” time points than was observed with blood plasma, at least partially due to significant person-to-person variability in the plasma proteome. A total of 399 proteins were identified from oral fluid samples, and the abundance of 102 of those proteins was determined to be significantly different upon metabolism of hydrocodone (4 and 6 hour time points) as compared to baseline levels in the oral fluid (pre-dose and 168 hour). This is the first, to our knowledge, assessment of the oral fluid and blood plasma proteome following hydrocodone administration, which demonstrates the potential of oral fluid as a non-invasive sample that may reveal features of hydrocodone or other opioid use and/or misuse.

Kaiser, Brooke LD↗

The interaction of acetonitrile with H-terminated and depassivated (100) diamond surfaces

Molecular adsorption on reactive semiconductor surfaces may enable novel surface functionalisation and atomically-precise dopant formation. In this work synchrotron-based x-ray photoelectron spectroscopy and near edge x-ray absorption spectroscopy are used to examine the interaction between acetonitrile and diamond (100) surfaces under ultrahigh vacuum (UHV) conditions. We observe two surface-bound nitrogen species on hydrogen terminated surfaces after thermal depassivation or following synchrotron radiation and subsequent exposure to acetonitrile, but find no evidence of nitrogen adsorption on the hydrogen-terminated diamond surface, at room temperature. Subsequent measurements explore the stability of the surface-bound nitrogen under various temperature conditions and with atmospheric exposure. While the nitrogen coverage achieved in this study is low, this study serves as a proof-of-concept demonstration of a UHV molecular dosing approach to selective nitrogen functionalisation of diamond surfaces as an alternative to plasma-based approaches. This development may be critical for proposed surface-based fabrication workflows using atomic placement of nitrogen-vacancy centres to create quantum devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Database of pharmacokinetic time-series data and parameters for 144 environmental chemicals

Time courses of compound concentrations in plasma are used in chemical safety analysis to evaluate the relationship between external administered doses and internal tissue exposures. This type of experimental data is rarely available for the thousands of non-pharmaceutical chemicals to which people may potentially be unknowingly exposed but is necessary to properly assess the risk of such exposures. In vitro assays and in silico models are often used to craft an understanding of a chemical’s pharmacokinetics; however, the certainty of the quantitative application of these estimates for chemical safety evaluations cannot be determined without in vivo data for external validation. To address this need, we present a public database of chemical time-series concentration data from 567 studies in humans or test animals for 144 environmentally-relevant chemicals and their metabolites (187 analytes total). All major administration routes are incorporated, with concentrations measured in blood/plasma, tissues, and excreta. We also include calculated pharmacokinetic parameters for some studies, and a bibliography of additional source documents to support future extraction of time-series. In addition to pharmacokinetic model calibration and validation, these data may be used for analyses of diferential chemical distribution across chemicals, species, doses, or routes, and for meta-analyses on pharmacokinetic studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward an effective use of laser-driven very high energy electrons for radiotherapy: Feasibility assessment of multi-field and intensity modulation irradiation schemes

Radiotherapy with very high energy electrons has been investigated for a couple of decades as an effective approach to improve dose distribution compared to conventional photon-based radiotherapy, with the recent intriguing potential of high dose-rate irradiation. Its practical application to treatment has been hindered by the lack of hospital-scale accelerators. High-gradient laser-plasma accelerators (LPA) have been proposed as a possible platform, but no experiments so far have explored the feasibility of a clinical use of this concept. We show the results of an experimental study aimed at assessing dose deposition for deep seated tumours using advanced irradiation schemes with an existing LPA source. Measurements show control of localized dose deposition and modulation, suitable to target a volume at depths in the range from 5 to 10 cm with mm resolution. The dose delivered to the target was up to 1.6 Gy, delivered with few hundreds of shots, limited by secondary components of the LPA accelerator. Measurements suggest that therapeutic doses within localized volumes can already be obtained with existing LPA technology, calling for dedicated pre-clinical studies.

59 BASIC BIOLOGICAL SCIENCES↗

Homotypic aggregates contribute to heterogeneity in B cell fates due to an intrinsic gradient of stimulant exposure

Highlights: • CD40-signaled B cells in cultures form three-dimensional homotypic aggregates. • These tight aggregates hinder the free diffusion of large molecule stimulants. • The resulting concentration gradient of stimulants leads to heterogeneous cell fates. • We describe a flow cytometric approach to quantify this positional information. Monocultures of several cell types result in the formation of robust clusters called homotypic aggregates (HAs). How this physical aggregation affects cell fates in immune cell cultures, is poorly understood. We studied anti-CD40-stimulated primary B cell cultures, where cells assembled into large three-dimensional LFA1-driven HAs by 72 h. The dense packing in these aggregates restricts the infiltration of stimulants, such as antibodies, to cells inside the clusters. This creates a concentration gradient of stimulant availability across the cross-section of HAs. We describe a method to retain this positional information even after the disruption of HAs, for analysis by flow cytometry. Comparison of stage-specific cell-surface markers showed that the extent of stimulant-binding affected multiple fates non-uniformly. While germinal center and lineage markers were moderately upregulated, immunoglobulins and markers associated with memory were more than doubled in the peripheral cells binding more anti-CD40. These cells also experienced a strong repression of the plasma cell regulator Prdm1 and an upregulation of the oncogene Myc. Thus, cells at different locations in HAs are subjected to unequal doses of stimulants, leading to a hitherto unreported source of heterogeneity in cell fates. These findings can be extrapolated to understand the dose-dependent effects of stimulants in other three-dimensional cell clusters.

60 APPLIED LIFE SCIENCES↗

A new platform for ultra-high dose rate radiobiological research using the BELLA PW laser proton beamline

Abstract Radiotherapy is the current standard of care for more than 50% of all cancer patients. Improvements in radiotherapy (RT) technology have increased tumor targeting and normal tissue sparing. Radiations at ultra-high dose rates required for FLASH-RT effects have sparked interest in potentially providing additional differential therapeutic benefits. We present a new experimental platform that is the first one to deliver petawatt laser-driven proton pulses of 2 MeV energy at 0.2 Hz repetition rate by means of a compact, tunable active plasma lens beamline to biological samples. Cell monolayers grown over a 10 mm diameter field were exposed to clinically relevant proton doses ranging from 7 to 35 Gy at ultra-high instantaneous dose rates of 10 7 Gy/s. Dose-dependent cell survival measurements of human normal and tumor cells exposed to LD protons showed significantly higher cell survival of normal-cells compared to tumor-cells for total doses of 7 Gy and higher, which was not observed to the same extent for X-ray reference irradiations at clinical dose rates. These findings provide preliminary evidence that compact LD proton sources enable a new and promising platform for investigating the physical, chemical and biological mechanisms underlying the FLASH effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative neutron-irradiation effects on thermal conductivity degradation and dimensional stability of TiC, TiB 2 , and ZrB 2 at 200–1000 °C

Ultra-high-temperature ceramics (UHTCs), including TiC, Ti 11 B₂, and Zr 11 B₂, show great potential for plasma-facing components due to their excellent high-temperature properties prior to irradiation. However, their response to neutron irradiation remains insufficiently understood, limiting robust assessment of their viability for fusion energy applications. Here, this study examines the thermal conductivity, dimensional stability and microstructure of TiC, TiB₂, and ZrB₂ following neutron irradiation at temperatures of 200–1000 °C and fast neutron fluences of 2.0 × 10 25 to 1.1 × 10 26 n/m 2 (E > 0.1 MeV). Lattice swelling measured by synchrotron X-ray diffraction in all three UHTCs was maximized at 200 °C and decreased with increasing irradiation temperature, with no evidence of amorphization observed at 200 °C. Above 600 °C, significant macroscopic volume swelling was observed in irradiated Ti 11 B₂ and Zr 11 B₂, but not in TiC, likely due to cavity formation in the diborides. The post-irradiation thermal conductivity, measured at the irradiation temperature, ranged from 28 to 45 W/m·K, representing a 34–45% reduction relative to the unirradiated material. Notably, neutron-irradiated UHTCs exhibit recoverable thermal conductivity at elevated temperatures, comparable to ferritic–martensitic steels and potentially superior to W when transmutation effects are considered, highlighting promise for shielding or armor plasma-facing components. At 600 °C, both thermal conductivity degradation and lattice swelling saturated at doses exceeding 2–4 dpa.

fusion materials↗

Advances in laser-based bremsstrahlung x-ray sources. I. Optimizing laser-accelerated electrons

In this work, we have performed a suite of kinetic simulations of relativistic laser–plasma interaction under settings relevant to recent and planned experiments on a variety of laser systems. The goal of the study is to illuminate the physics of laser–target coupling and to provide guidance for how to optimize these sources for applications. It is shown that the production of relativistic electrons is maximized when conditions of relativistic induced transparency (RIT) in dense plasmas can be achieved over a large interaction volume at the time of arrival of most intense part of the laser pulse. RIT is shown to enhance both the numbers of relativistic electrons and the energies of the electrons, leading to an increased x-ray dose. A variety of approaches to enhancing laser–target coupling are considered. These include optimizing the effects of low-density pre-plasma (arising either from finite laser pedestal or from the use of foam coatings) and of modifying the laser focusing geometry to reduce effects of filamentation and self-focusing. Evidence of a novel approach to achieving stable laser propagation over distances of tens of micrometers in a plasma gradient is also presented. These conditions coincide with plasma and laser conditions explored in recent experiments on the Omega EP laser system and compare favorably with an analytic criterion for stable laser propagation in relativistically underdense plasma obtained from a nonlinear Wentzel–Kramers–Brillouin analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗