Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Laser-Plasma Spatiotemporal Cyanide Spectroscopy and Applications

This article reports new measurements of laser-induced plasma hypersonic expansion measurements of diatomic molecular cyanide (CN). Focused, high-peak-power 1064 nm Q-switched radiation of the order of 1 TW/cm 2 generated optical breakdown plasma in a cell containing a 1:1 molar gas mixture of N 2 and CO 2 at a fixed pressure of 1.1 × 10 5 Pascal and in a 100 mL/min flow of the mixture. Line-of-sight (LOS) analysis of recorded molecular spectra indicated the outgoing shockwave at expansion speeds well in excess of Mach 5. Spectra of atomic carbon confirmed increased electron density near the shockwave, and, equally, molecular CN spectra revealed higher excitation temperature near the shockwave. Results were consistent with corresponding high-speed shadowgraphs obtained by visualization with an effective shutter speed of 5 nanoseconds. In addition, LOS analysis and the application of integral inversion techniques allow inferences about the spatiotemporal plasma distribution.

36 MATERIALS SCIENCE↗

Combined Impedance Probe and Langmuir Probe Studies of the Low-Latitude E Region

The EQUIS-2 sounding rocket and radar campaign, launched from Kwajalein Atoll in 2004, included a mission to study low-latitude irregularities and electrodynamics, led by NASA GSFC. This mission included two instrumented rockets launched into the nighttime E region (apogee near 120 km), which included comprehensive electrodynamics and neutral density instrumentation. These rockets carried the first of a new generation of impedance probes, that utilize a wide-band drive signal to simultaneously measure the impedance of an antenna in a plasma as a function of frequency from 7 kEIz to 4 MHz. at a rapid cadence. This technique promises to permit true plasma spectroscopy, and resulted in the identification of multiple plasma resonances and accurate measurements of the plasma density, even in the low density nighttime E region. We present analyses of the technique and resulting spectra, and show how these data may be combined with fixed-bias Langmuir Probe data to infer the temperature structure of the E region as well as providing accurate absolute calibrations for the very high time resolution fixed-bias probe data. The data is shown to agree well with data from ionosonde, the ALTAIR radar, and the Peruvian beacon experiment.

Rowland, D. E.↗

High-resolution spectroscopy of uranium laser-produced plasma using saturated absorption spectroscopy

High-resolution spectroscopy of laser ablation plumes or laser-produced plasmas (LPPs) is valuable for various applications, including measuring crowded spectral features, determining spectroscopic constants, characterizing plasmas, and performing isotopic analysis. However, various line broadening mechanisms in plasmas limit its use for several applications. Here, in this study, we present the use of saturated absorption spectroscopy (SAS) for Doppler-free linewidth analysis in a uranium LPP. We demonstrate that SAS is effective in obtaining Doppler-free Lamb dip profiles with linewidths on the order of ≤ 20 MHz. The effects of saturation on the Doppler-broadened absorption and Lamb dip profiles at different pressures and probe intensities are quantified, and their impact on measurements of plasma properties is discussed. Finally, we show that the linewidths of the Lamb dips can be used for quantitative estimates of pressure and natural broadening in the plasma.

Absorption spectroscopy↗

Microwave digestion preparation and ICP determination of boron in human plasma

A microwave digestion procedure, followed by Inductively Coupled Argon Plasma Spectroscopy, is described for the determination of boron (B) in human plasma. The National Institute of Standards and Technology (NIST) currently does not certify the concentration of B in any substance. The NIST citrus leaves 1572 (CL) Standard Reference Material (SRM) and wheat flour 1567a (WF) were chosen to determine the efficacy of digestion. CL and WF values compare favorably to those obtained from an open-vessel, wet digestion followed by ICP, and by neutron activation and mass spectrometric measurements. Plasma samples were oxidized by doubled-distilled ultrapure HNO3 in 120 mL PFA Teflon vessels. An MDS-81D microwave digestion procedure allows for rapid and relatively precise determination of B in human plasma, while limiting handling hazards and sources of contamination.

Ferrando, A. A.↗

High Power ECR Ion Thruster Discharge Characterization

Electron cyclotron resonance (ECR) based ion thrusters with carbon based ion optics can potentially satisfy lifetime requirements for long duration missions (approximately 10 years) because grid erosion and cathode insert depletion issues are virtually eliminated. Though the ECR plasma discharge has been found to typically operate at slightly higher discharge losses than conventional DC ion thrusters (for high total thruster power applications), the discharge power fraction is small (less than 1 percent at 25 kW). In this regard, the benefits of increased life, low discharge plasma potentials, and reduced complexity are welcome tradeoffs for the associated discharge efficiency decrease. Presented here are results from discharge characterization of a large area ECR plasma source for gridded ion thruster applications. These measurements included load matching efficacy, bulk plasma properties via Langmuir probe, and plasma uniformity as measured using current probes distributed at the exit plane. A high degree of plasma uniformity was observed (flatness greater than 0.9). Additionally, charge state composition was qualitatively evaluated using emission spectroscopy. Plasma induced emission was dominated by xenon ion lines. No doubly charged xenon ions were detected.

Foster, John E.↗

Cubic crystals in an x-ray polarization-splitting geometry

Hexagonal and cubic crystals contain paired sets of internal planes that reflect the linearly polarized components of certain x rays into two separate, perpendicular directions. For the cubic crystals, two distinct crystal orientations provide the same polarization-splitting geometry. One of the orientations may have advantages for plasma spectroscopy by suppressing unwanted reflections. This paper demonstrates the two orientations with a germanium crystal and K characteristic lines from copper and zirconium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanism of H 2 plasma-enabled reduction of hematite thin films

Hydrogen plasma is gaining significant interest as a promising pathway for direct iron ore reduction and for lowering process temperatures but the reduction mechanism remains poorly understood. In this work we analyzed the plasma and thermal reduction of thin-film hematite (Fe 2 O 3 ) at temperatures below 340 °C using X-ray diffraction and scanning electron microscopy with energy-dispersive X-ray spectroscopy. Plasma reduced the incubation period by an order of magnitude and increased the reduction rate by a factor of 2.6 compared to thermal reduction. Plasma-produced H-atoms facilitate the formation of numerous iron nucleation sites, bypassing the energetically unfavorable dissociative adsorption of H 2 on iron oxide. These iron nuclei can autocatalyze the reduction of the surrounding hematite via a hydrogen spillover mechanism. Our results demonstrate that plasma-derived H-atoms primarily impact the initial nucleation-limited stage. These new insights provide a mechanistic framework that can aid the implementation and optimization of hydrogen plasma-assisted iron oxide reduction at reduced temperatures.

08 HYDROGEN↗

A laboratory study on the dissociative recombination of vibrationally excited O2/+/ions

The dissociative recombination of vibrationally excited O2(+) ions is studied in light of the possible importance of this reaction in upper atmospheric chemistry. A plasma spectroscopy experiment was performed in a microwave cavity filled by an argon-oxygen mixture, with O(1S) production monitored by measurements of the 5577-A afterglow, the O2(+) density and the electron concentration. Plasma and optical data reveal the predominant afterglow ions to be Ar2(+) and O2(+), with an effective O(1S) dissociative recombination coefficient of 2.1 x 10 to the -8th cu cm/sec, corresponding to a quantum yield of 10%. Experiments with an argon-krypton-oxygen mixture reveal that vibrationally excited O2(+) ions are the chief source of the O(1S) atoms, with a specific recombination coefficient for the dissociation of O2(+)(2 pi g) into O(1S) and O(1D) of 4.2 x 10 to the -9th cu cm/sec. A comparison of the laboratory results with Atmospheric Explorer data on the 5577-A airglow implies that O2(+) ions in the sunlit ionosphere are vibrationally excited to the same degree as in the laboratory, with the vibrational relaxation of these ions much slower than dissociative recombination. Results also predict a dawn-twilight asymmetry in the effective O(1S) yield due to the normal variation of electron content.

Zipf, E. C.↗

Electron cyclotron resonance deposition and plasma diagnostics of a-Si:H and a-C:H films

Amorphous silicon (a-Si:H) and amorphous carbon (a-C:H) films deposited by electron cyclotron resonance (ECR) microwave plasma-enhanced chemical vapor deposition are discussed. It is shown that the ECR microwave plasma deposition technique can produce a-Si:H films with material qualities similar to and with a deposition rate one order of magnitude higher than for films deposited by radio-frequency glow discharge. The ECR-deposited a-C:H films are characterized by fluorescence, IR, and Raman spectroscopy. In situ optical emission spectroscopy plasma diagnostics indicates that ECR plasmas have a strong emission at 434 nm, which indicates a higher chemical reactivity than radio-frequency glow discharge plasmas. The radio frequency bias to the substrate is found to play a critical role in determining the film structure and the carbon bonding configuration of ECR-deposited a-C:H films.

Shing, Y. H.↗

Use of Electronic Laboratory Notebooks (ELN) in a Laboratory Information Management System (LIMS) [Slides]

The Actinide Analytical Chemistry (CAAC) group at Los Alamos National Laboratory (LANL) uses the LabWare LIMS (LabWare 7) system to manage our samples and material at risk. The LIMS system also provides other functionality which the Plasma Spectroscopy (PS) team has developed along with our LIMS team to provide streamlining and automation of all sample related actions required by PS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of helium line intensity ratio spectroscopy to xenon plasma in E × B Penning discharge

Here, we propose the application of helium line intensity ratio spectroscopy in a low-pressure (0.3 mTorr) xenon E × B discharge with an electron temperature of ~2 eV and a density of 10 10 –10 11 cm –3 . We successfully identified the helium atom line emissions at 388.9, 447.1, 501.6, 504.8, and 706.5 nm with helium pressures of up to ~20 mTorr. The measured electron temperature, density, and I–V characteristics of the discharge remained almost constant in all helium pressures in the present experiment, indicating the suitability of the helium gas as a diagnostic gas. The results of helium line intensity ratio spectroscopy using the line emissions at 388.9, 447.1, and 504.8 nm showed fair agreement with the Langmuir probe measurement. Considering the trade-off relationship between the disturbance introduced by the helium gas and the signal-to-noise ratio, we conclude that a helium pressure of approximately 4 mTorr (approximately 13 times the partial pressure of xenon) represents the optimal pressure range for the application of the helium line emission intensity ratio method to this xenon plasma. It is found that the use of the line emissions at 501.6 and 706.5 nm result in a significant disturbance in the helium line intensity ratio method due to the radiation trapping effect.

helium line intensity ratio spectroscopy↗

Trace Elemental Analysis of Bulk Thorium Using an Automated Separation–Inductively Coupled Plasma Optical Emission Spectroscopy Methodology

Presented here is a novel automated method for determining the trace element composition of bulk thorium by inductively coupled plasma–optical emission spectroscopy (ICP-OES). ICP-OES is a universal approach for measuring the trace elemental impurities present in actinide-rich materials; however, due to the emission rich spectrum of the actinide, a separation from the trace elements is warranted for spectrochemical analysis. Here, AG MP-1 ion exchange resin was utilized for retention of the Th matrix, while allowing the trace element impurities to be separated prior to subsequent analysis using ICP-OES. After demonstrating the separation on traditional gravity-driven columns, the methodology was transitioned to an automated platform for comparison. This automated platform utilizes syringe-driven sample and solvent flow and can collect the trace element and thorium fractions in separate locations. Finally, while reducing the sample size (500 µL, 1.5 mg of Th), maintaining the overall separation efficiency (recoveries >95%), and illustrating the sample throughput ability (n = 10+), this automated methodology could be readily adopted to nuclear facilities in which the determination of trace elemental impurities in Th samples is warranted.

47 OTHER INSTRUMENTATION↗

Transuranium Sulfide via the Boron Chalcogen Mixture Method and Reversible Water Uptake in the NaCu T S 3 Family

The behavior of 5f electrons in soft ligand environments makes actinides, and especially transuranium chalcogenides, an intriguing class of materials for fundamental studies. Due to the affinity of actinides for oxygen, however, it is a challenge to synthesize actinide chalcogenides using non-metallic reagents. Using the Boron Chalcogen Mixture (BCM) method, we achieved the synthesis of the transuranium sulfide NaCuNpS 3 starting from the oxide reagent, NpO 2 . Via the same synthetic route, the isostructural composition of NaCuUS 3 was synthesized and the material contrasted with NaCuNpS 3 . Single crystals of the U-analog, NaCuUS 3 , were found to undergo an unexpected reversible hydration process to form NaCuUS 3 ·xH 2 O (x ≈ 1.5). Here, a large combination of techniques was used to fully characterize the structure, hydration process, and electronic structures, specifically a combination of single crystal, powder, high temperature powder X-ray diffraction, extended X-ray ab-sorption fine structure, infrared, and inductively coupled plasma spectroscopies, thermogravimetric analysis, and density functional theory calculations. The outcome of these analyses enabled us to determine the composition of NaCuUS 3 ·xH 2 O and obtain a structural model that demonstrated the retention of the local structure within the [CuUS 3 ] – layers throughout the hydration-dehydration process. Band structure, density of states, and Bader charge calculations for NaCuUS 3 , NaCu-US 3 ·xH 2 O, and NaCuNpS 3 along with X-ray absorption near edge structure, UV-vis-NIR and work function measurements on ACuUS 3 (A = Na, K, and Rb) and NaCuUS 3 ·xH 2 O samples were carried out to demonstrate that electronic properties arise from the [CuTS 3 ] – layers and show surprisingly little dependence on the interlayer distance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic layer deposition for surface area determination of solid oxide electrodes

Surface area measurements are important for characterizing porous solids, but commonly used methods such as Brunauer–Emmett–Teller (BET) gas adsorption and computed nanotomography are lacking for certain applications such as the development of solid oxide fuel cell electrodes, which often have absolute surface areas <1 m 2 and contain nanoscale features. Presented is a novel method for the surface area determination of samples with total measurable areas of 1–1000 cm 2 with a standard deviation ± 1 cm 2 , utilizing the atomic layer deposition (ALD) of Al 2 O 3 over microstructurally complex internal porosity. The volume of alumina is then quantified using plasma spectroscopy and converted to an area using the known ALD layer thickness. Under the modest ALD reactor soak times used (8.5 s), the precursor penetration depth is found to be ~50 μm, exceeding the requirement for uniformly coating SOFC functional layers. A model system, (La 0.8 Sr 0.2 ) 0.98 MnO 3–δ /Ce 0.9 Gd 0.1 O 1.95 (LSM/GDC) scaffolds of ~2.7 m 2 g –1 , was measured using the technique and compared against the BET method, and comparable results were obtained but with 1000 times less material needed. The technique is demonstrated for measurements in two example areas of active SOFC research: exsolved (Ni, Fe) nanoparticles on an Sr(Ti, Fe, Ni)O 3–δ electrode and PrO x catalyst nanoparticles infiltrated onto LSM/GDC scaffolds. Finally, the technique may be broadly useful wherever the accurate surface area determination of small absolute quantities of porous ceramic structures on the order of 0.1–50 m 2 g –1 is sought.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Method Developed To Purify Single Wall Carbon Nanotubes for Aerospace Applications

Single wall carbon nanotubes have attracted considerable attention because of their remarkable mechanical properties and electrical and thermal conductivities. Use of these materials as primary or secondary reinforcements in polymers or ceramics could lead to new materials with significantly enhanced mechanical strength and electrical and thermal conductivity. Use of carbon-nanotube-reinforced materials in aerospace components will enable substantial reductions in component weight and improvements in durability and safety. Potential applications for single wall carbon nanotubes include lightweight components for vehicle structures and propulsion systems, fuel cell components (bipolar plates and electrodes) and battery electrodes, and ultra-lightweight materials for use in solar sails. A major barrier to the successful use of carbon nanotubes in these components is the need for methods to economically produce pure carbon nanotubes in large enough quantities to not only evaluate their suitability for certain applications but also produce actual components. Most carbon nanotube synthesis methods, including the HiPCO (high pressure carbon monoxide) method developed by Smalley and others, employ metal catalysts that remain trapped in the final product. These catalyst impurities can affect nanotube properties and accelerate their decomposition. The development of techniques to remove most, if not all, of these impurities is essential to their successful use in practical applications. A new method has been developed at the NASA Glenn Research Center to purify gram-scale quantities of single wall carbon nanotubes. This method, a modification of a gas phase purification technique previously reported by Smalley and others, uses a combination of high-temperature oxidations and repeated extractions with nitric and hydrochloric acid. This improved procedure significantly reduces the amount of impurities (catalyst and nonnanotube forms of carbon) within the nanotubes, increasing their stability significantly. The onset of decomposition of the purified nanotubes (determined by thermal gravimetric analysis in air) is more than 300 C higher than that of the crude nanotubes. Transmission electron microscopy analysis of nanotubes purified by this method reveals near complete removal of iron catalyst particles. Analysis of the nanotubes using inductively coupled plasma spectroscopy revealed that the iron content of the nanotubes was reduced from 22.7 wt% in the crude nanotubes to less than 0.02 wt%. X-ray photoelectron spectroscopy revealed a decrease in iron content after purification as well as an increase in oxygen content due to the formation of carboxylic acid groups on the surface of the nanotubes. Nanotubes purified by this improved method can be readily dispersed in common organic solvents, in particular N,N-dimethylformamide, using prolonged ultrasonic treatment. These dispersions can then be used to incorporate single wall carbon nanotubes into polymer films.

Lebron, Marisabel↗

Performance and Analysis of Perfluoropolyalkyl Ether Grease Used on Space Shuttle Actuators--A Case Study

Actuators used on the United States space shuttle fleet are lubricated with unspecified amounts of Braycote 601 (Castrol Braycote) grease consisting of a perfluoropolyalkyl ether (PFPAE) base oil thickened with a polytetrafluoroethylene (PTFE) filler. Each shuttle has four body flap actuators (BFAs) (two on each wing) on a common segmented shaft and four rudder speed brake (RSB) actuators. The actuators were designed to operate for 10 years and 100 flights without periodic relubrication. Visible inspection of two partially disassembled RSB actuators in continuous use for 19 years raised concerns over possible grease degradation due to discoloration of the grease on several places on the surfaces of the gears. Inspection revealed fretting, micropitting, wear and corrosion of the bearings and gears. A small amount of oil dripped from the disassembled actuators. Whereas new grease is beige in appearance, the discolored grease consisted of both grey and reddish colors. Grease samples taken from the actuators together with representative off-the-shelf new and unused grease samples were analyzed by gravimetry for oil content; by inductively coupled plasma spectroscopy (ICP) for metals content; Fourier transform infrared (FTIR) spectroscopy for base oil decomposition; and by size exclusion chromatography (SEC) for determination of the molecular weight distributions of the grease oil. The Braycote 601 grease was stable after 19 years of continuous use in the sealed RSB actuators and was fit for its intended purpose. There were no significant chemical differences between the used grease samples and new and unused samples. Base oil separation was not significant within the sealed actuators. No corrosive effect in the form of iron fluoride was detected. The grey color of grease samples was due to metallic iron. The red color was due to oxidation of the metallic wear particles from the gears and the bearings comprising the actuators.

Morales, Wilfredo↗