Search NASA⌕ Search

SEARCH · Search NASA

Results for “plug load control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Best Practices for Plug Load Management Using a Building Energy Management System

The University of California San Diego (UCSD) successfully integrated PLCs with their BEMS, which resulted in 66% energy savings over one week across 25 plug loads (K. Chia et al. 2023). UCSD documented each step of this effort, highlighting best practices along the way, in their 10-page brief, "Best Practices for Plug Load Management Using a Building Energy Management System" (also referred to as "brief" in this document). This fact sheet provides highlights and key takeaways from UCSD's brief. The reader is encouraged to read UCSD's full brief if they wish to move forward with implementing PLC integration with their BEMS.

Building Energy Management System Integration↗

Device-level plug load disaggregation in a zero energy office building and opportunities for energy savings

Along with heating, cooling, ventilation, and lighting, plug loads are one of the principal consumers of energy in commercial buildings. Managing ever-changing plug loads is a great challenge given the quantity and variety of devices in commercial buildings and the cost of monitoring equipment. To address this issue, we propose a method for developing a disaggregated model of an office building's plug loads that utilizes power data from a small portion of monitored devices and a device inventory. Using data from metering and control devices in the Research Support Facility at the National Renewable Energy Laboratory, we compared our model to the building's plug load submeters. We found that the model was effective in predicting the shape of the building's average plug loads; however, it did not account for the entire magnitude of the load. With the disaggregated breakdown, we identified devices that contributed significantly to the building's unoccupied load, such as the audio visual equipment as well as devices that contributed significantly at specific times of the day, such as the microwaves at noon. This disaggregated information enables building owners to make more informed decisions with respect to plug load controls and energy efficiency upgrades. Furthermore, we highlight how the plug loads in the Research Support Facility have changed over time and offer recommendations for implementing this disaggregation method in other buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic Receptacle Controls: Evaluating the clarity of receptacle markings

Plug loads and the electric loads of devices plugged into receptacles in commercial buildings play a significant and growing role in commercial buildings. Because plug loads are portable and are often placed in the building by the occupants, they are a challenging load to manage. This report summarizes an analysis of commercially available automatic receptacle controls (ARCs). As a part of this study, generic versions of ARCs were presented to a general user audience via an online survey, wherein survey respondents indicated which markings more clearly indicated that the receptacle was controlled. A total of 210 responses were collected and included in the analysis presented in this report. The results showed that receptacles with high-contrast markings were consistently clearer and more evident to the users than low-contrast markings. The survey responses also revealed that receptacles with a border drawn around each controlled receptacle were clearer and distinct to the users compared to other markings. These results led to the conclusion that for energy saving technology to be effective, consistent and easy to understand markings are necessary.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ibis Networks/WattIQ (IN2 Final Report)

Ibis Networks is a full-stack cleantech company that provides plug-level energy monitoring and control to solve energy and asset management problems for the enterprise. During DATES – DATES, an NREL research team worked with the Ibis team to validate their product, the InteliSocket. The Ibis InteliSocket is a pass-through plug-load energy monitor and controller that is designed to reduce energy wasted by common 120 V plug-in devices in commercial office buildings, such as computer peripherals, conference room AV equipment, and break-room appliances. The system can shut off supply power to these end uses via remote control, manual switches, pre-set schedules, or automated control algorithms. The scope of this IN2 project was the development and refinement of “smart” learning behavior algorithms (LBAs), which could help installation processes and dramatically expand the sockets’ capabilities and energy-saving potential by suggesting suitable control schedules that are based on monitored use patterns. While Ibis has the analytical and software expertise for algorithm development, the lack of test data, both in a controlled laboratory setting and in real-life deployment scenarios, represented a key barrier toward commercialization of the product. Assistance through the IN2 program provided an opportunity to conduct the needed “trial and error” algorithm development. The project included baseline field-data collection, laboratory testing, and field validation components, all of which were conducted at the NREL campus between April 2017 and July 2019.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emerging Technologies for Improved Plug Load Management Systems: Learning Behavior Algorithms and Automatic and Dynamic Load Detection

Plug loads are responsible for a significant portion of the energy consumed in commercial buildings, yet their distributed and ever-changing nature makes them one of the most challenging building end uses to manage. Plug load management systems exist today that utilize smart plugs to meter and control devices at the outlet level, however, their uptake has been relatively slow in part due to the significant labor required for installation and maintenance. Learning behavior algorithms and automatic and dynamic load detection have been identified as two technology areas that could accelerate the adoption of plug load management systems by reducing these labor demands and providing additional energy efficiency and non-energy benefits. Learning behavior algorithms learn occupant behavior and adjust plug load management systems accordingly, allowing for the automatic creation of optimized control schedules. Automatic and dynamic load detection allows a plug load management system to identify devices as they are plugged in to a building and keeps the system up to date as devices are moved throughout a building. In this paper, we present our findings with respect to the current state of these two technologies based on a review of existing research and patents, as well as a series of interviews with companies working in the plug load space. We have found that, as of now, no commercialized solutions exist for these plug load technologies and that more work is needed to bring them to market. In addition, we summarize our findings related to the technology challenges, market barriers, drivers, and opportunities for these technologies moving forward.

30 DIRECT ENERGY CONVERSION↗

Macromolecular crystal growing system

A macromolecular crystal growing system especially designed for growing crystals in the low gravity of space as well as the gravity of earth includes at least one tray assembly, a carrier assembly which receives the tray, and a refrigeration-incubation module in which the carrier assembly is received. The tray assembly includes a plurality of sealed chambers with a plastic syringe and a plug means for the double tip of the syringe provided therein. Ganging mechanisms operate the syringes and plugs simultaneously in a precise and smooth operation. Preferably, the tray assemblies are mounted on ball bearing slides for smooth operation in inserting and removing the tray assemblies into the carrier assembly. The plugging mechanism also includes a loading control mechanism. A mechanism for leaving a syringe unplugged is also provided.

Snyder, Robert S.↗

Frequency Restoration of Grid-Forming Inverters in Pulse Load and Plug-in Events

This article presents a restoration technique using grid-forming inverters in an islanded microgrid during pulse load and plug-in events. In a microgrid powered by droop-controlled inverters, frequency is the variable that is accessible to all inverters for adjusting their power contributions. The problem is that the microgrid frequency deviates from its nominal value after a load change. The presented method enables the inverters to restore the frequency to the nominal value and regulate their bus voltage amplitudes. The frequency and voltage restorations are performed without communication while achieving the desired power-sharing between grid-forming inverters. The restoration is activated after detecting any active or reactive power changes. In this article, the dynamic model of an inverter equipped with enabled restoration paths is developed to verify the stability of the inverter controller under various conditions. The frequency and voltage restorations are examined during pulse load and plug-in events. Furthermore, this study is performed using a laboratory-scale islanded microgrid powered by two 208 V, 60 Hz, 5 kVA inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Project Report: School Retrofit Demonstration of Lighting and Outlet Controls with LED Upgrades

A technology demonstration project funded by the U.S. Department of Energy (DOE) was hosted by Boston Public Schools (BPS). This project evaluated wireless controls technology for lighting systems and plug loads (energy consumed by devices plugged into electrical outlets), implemented along with LED lighting retrofits in two classrooms. This study assesses technology readiness and effectiveness to determine the deployment potential of the technology in schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Savings for ENERGY STAR Smart Home Energy Management Systems

The objective of this study was to develop a repeatable and defensible methodology to analyze the energy savings for Home Energy Management Systems (HEMS) that meets the minimum requirements for certification under ENERGY STAR ® Smart Home Energy Management System (SHEMS) Version 1. Mandatory connected loads include a smart thermostat, two smart lights, and one smart power strip or smart outlet. Control strategies must include feedback to occupants through an in-home display, user programming, occupancy sensor-based controls, and responsiveness to utility signals such as demand response programs. Several occupant behavior patterns were selected to quantify the range of energy savings potential for a HEMS with this basic functionality. A literature review was conducted to establish realistic room-by-room occupancy levels and usage patterns for connected devices. A series of event-driven hourly profiles were created, followed by adjustments based on application of HEMS control strategies to thermostats, interior lighting, and plug load schedules. EnergyPlus modeling was performed using these hourly schedules in three locations (Boston, Houston, and Phoenix) to examine climate dependence of energy savings. Total site energy savings ranged from 4.3 to 27.1 MBtu/year (7%-35%), and utility bill savings ranged from $\$$123 to $\$$670/year (6%-29%). The highest predicted savings was realized by occupants that were not energy conscious prior to HEMS installation, but highly engaged with the HEMS controls once the system was installed. The smart thermostat accounted for most of the savings, followed by the smart power strip. Smart lighting did not save a significant amount of energy in our analysis, based on an assumption that efficient LEDs with no standby power would normally be installed anyway.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

The Assistant Secretary of the Army (Installations, Energy and Environment) tasked the Pacific Northwest National Laboratory to examine plug loads in typical Army buildings. Plug loads (also known as miscellaneous electric loads (MELs)) represent the electricity used by appliances and devices that are plugged in or hardwired and serve functions outside of a building’s core end uses. Common plug loads include computers, printers, copiers, networking devices, refrigerators, and vending machines. They also include personal electronic devices such as televisions, smart phones, tablets, and gaming systems. Examples of hardwired MELs include elevators, air compressors, and fire and security systems. The findings from this study confirm that significant energy is consumed within Army buildings by plug load devices and hardwired MEL equipment. A number of opportunities are identified for reducing unnecessary energy use that could save the Army over $5 million per year when broadly applied. Army regulations clearly spell out expectations for the purchase and operation of information technology equipment (computers, laptops, monitors, printers, and multi-function devices). However, the policies regarding the shutdown or activation of sleep and other lower power modes after 30 minutes of inactivity (15 minutes for monitors) do not appear to be consistently followed. There are many effective approaches and pathways for impacting change as it relates to improving awareness, implementing measures, and adjusting behaviors to identify and reduce plug load energy use. The Army should prioritize and consider deploying all of these to better understand and manage plug load equipment to save energy and enhance resilience across their facilities. Engaging the building occupants who use these devices daily via outreach and education should be a strong component of the strategy. The focus should be on reducing waste without sacrificing productivity or the benefits that many of these devices provide. Continued evaluation of plug loads beyond that performed here is important to gather lessons from additional building and equipment types, and to stay aware of evolving device technology and management options. This will highlight additional needs for policies, best practices, control technologies, and education of personnel to achieve real reductions in energy waste from plug load equipment. It is recommended that this study may serve as the foundation for a broader and sustained focus on plug loads and MELs, towards simultaneously enhancing the productivity, readiness, and resilience of the Army while reducing energy use and demand, and freeing up resources to better support the mission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated and Advanced Lighting Controls: The Next Frontier in Energy Savings?

Lighting energy use has significantly declined as a portion of overall building energy usage due largely to the uptake of more efficient light-emitting diode technology. Although the per unit cost of lighting controls has declined, the installation and use of lighting controls are low and the installation and use of advanced controls are abysmally low. Increased use of advanced and connected lighting controls, and the ability to integrate lighting with other building systems (e.g., heat and air, plug loads, miscellaneous loads) that make the building “smarter,” offer the potential for additional energy savings. Studies into the performance of new, advanced lighting control technologies in commercial buildings have generated new findings. Although each field evaluation has interesting results individually, an analysis of their collective findings across a spectrum of commercial building types will help establish the current state of the technology and implications related to market readiness. This paper will analyze results from available field evaluation studies (recently completed as well as ongoing) of retrofit sites and share findings and insights including: • The amount of energy savings that may be expected from these systems. • Cost effectiveness, monetization, and cost points of these systems. • Ideal characteristics of these systems the most viable. • Lessons learned from the installation, commissioning, and occupant response of these systems. The results will support Department of Energy research investments and help inform efficiency programs of the potential of these emerging technologies and how they may fit within the clean energy future.

Myer, Michael↗

Managing Army Plug Load Equipment Energy Use: Breakroom Appliances

Breakroom equipment is the third highest energy-consuming plug load category in Army buildings. In addition to the vending machine measures described separately, improved purchasing and control measures for breakroom appliances can save the Army more than 9 million kWh and $550K per year in the building types evaluated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Refining Control, Charging, and Battery Chemistry for CO 2 e Savings in Heavy-Duty Off-Road Plug-In Series Hybrid

With current and future regulations continuing to drive reductions in carbon dioxide equivalent (CO 2 e) emissions in the on-road industry, the off-road industry is also likely to be regulated for fuel and CO 2 e savings. This work focuses on converting a heavy-duty off-road material handler from a conventional diesel powertrain to a plug-in series hybrid, achieving a 49% fuel reduction and 29% CO 2 e reduction via simulation. Control strategies were refined for energy savings, including a regenerative braking strategy to increase regenerative braking and a load-following hydraulic strategy to decrease electrical energy consumption. The load-following hydraulic control shuts off the hydraulic electric machine when it is not needed—an approach not previously seen in a load-sensing, pressure-compensated system. Furthermore, these strategies achieved a 24.1% fuel savings, resulting in total savings of 61% in fuel and 41% in CO 2 e in the plug-in series compared to the conventional machine. Beyond control strategies, this study evaluated battery chemistry and charging strategy refinements for total cost of ownership (TCO) and lifetime CO 2 e. LFP batteries emerged as the most cost-effective and least emitting due to their longer lifespan, which reduced replacement frequency. Charging comparisons showed that Level 2 charging (L2C) typically resulted in lower TCO but higher lifetime CO 2 e than DC fast charging (DCFC). DCFC costs were heavily influenced by local demand charges, and DCFC emissions were heavily influenced by local grid emissions.

33 ADVANCED PROPULSION SYSTEMS↗

ELECTRIFICATION OF A HEAVY-DUTY OFF-ROAD MATERIAL HANDLER: ENERGY SAVINGS AND EMISSION REDUCTIONS

Federal regulations are driving the adoption of electrification technologies to reduce carbon dioxide equivalent (CO2e) emissions, a metric that quantifies the global warming potential of various greenhouse gases in terms of carbon dioxide (CO2). Although no specific CO2 regulations exist for heavy-duty off-road machines, future reductions are likely, given stricter emissions standards for on-road vehicles. The heavy-duty off-road sector offers significant fuel-saving potential, as its focus has traditionally been on reliability and performance rather than fuel efficiency. This dissertation examines fuel and CO2e savings opportunities on a heavy-duty off-road material handler, the Pettibone Cary-Lift 204i, from stock configuration to simple modifications to a complete teardown and reconfiguration of the machine with a plug-in series hybrid architecture using electrified hydraulics. The study begins by modeling the baseline machine’s fuel and energy consumption, calibrating with experimental data from custom operating cycles. An energy analysis identifies key areas for fuel savings. Two simple powertrain modifications result in a combined 16.2% fuel savings. Next, a Pugh-style analysis narrows a list of electrified architectures, leading to high-fidelity models that evaluate total lifetime CO2e and costs. Higher electrification levels reduce CO2e emissions but increase costs, and electricity grid emissions significantly impact CO2e for plug-in architectures. A plug-in series hybrid is chosen for the project. In its base control form, 49% fuel and 29% CO2e savings are expected from the plug-in series hybrid compared to the baseline machine. Further savings are pursued through regenerative braking (6.3%) and load-following hydraulic control (17.8%), totaling 24.1% fuel savings, and leading to a total of 61% fuel and 41% CO2e savings compared to the baseline. Battery chemistries and charging strategies are also analyzed for cost and CO2e impacts, finding LFP batteries as superior due to longevity, and overnight level 2 charging usually at a lower cost but resulting in higher emissions than opportunity DC fast-charging (DCFC). DCFC emissions are highly dependent on grid emissions, and DCFC cost is highly dependent on grid demand charges. Finally, artificial intelligence is applied to operating cycle recognition. Neural network accuracy ranges from 81% to 99%, with applications to worksite efficiency and safety improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct measurement and calculation of rubber bulk modulus by piston-cylinder method using conventional mechanical testing equipment

This article describes a method to directly measure the bulk modulus of rubber using a piston-cylinder type apparatus. The function of the testing apparatus is to reliably transfer load to the water inside the vessel and allow for the accurate and continuous measurement of volumetric displacement as the contents are compressed. During the test, load is applied to a piston-cylinder containing the rubber test sample and water using a conventional mechanical testing load frame. Load and the travel of the piston are recorded by a load cell and extensometer, respectfully. A brass or stainless steel plug of the same dimensions as the test sample is tested as a control sample to isolate the compliance of the system, including the compressibility of water and compliance of the piston-cylinder. The results from this control test are used to disincorporate the compliance of the system from the sample test results. Load-linear displacement data are mathematically converted to pressure-volumetric displacement data, from which bulk modulus is calculated. The test apparatus and method are validated using the known bulk modulus of water. Finally, the bulk modulus for two similar rubbers is evaluated. The validity of the results and limitations of the device are discussed.

36 MATERIALS SCIENCE↗

Motor Controller

M.H. Marks Enterprises' Power Factor Controller (PFC) matches voltage with motor's actual need. Plugged into a motor, PFC continuously determines motor load by sensing shifts between voltage and current flow. When it senses a light load, it cuts voltage to the minimum needed. It offers potential energy savings ranging from eight percent up to 65 percent depending on the application. Myles Marks started out with the notion of writing an article for Popular Electronics magazine at the same time offering to furnish kits to readers interested in assembling PFC's. Within two weeks from publication he had orders for 500 kits and orders are still coming three years later.

Source record↗

Low Carbon Technology Strategies: Small Office

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon small office buildings within their existing building portfolios. Small offices are typically less than 50,000 square feet and often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗