Search NASA⌕ Search

SEARCH · Search NASA

Results for “plugging temperature indicator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Recording Rapidly Changing Cylinder-wall Temperatures

The present report deals with the design and testing of a measuring plug suggested by H. Pfriem for recording quasi-stationary cylinder wall temperatures. The new device is a resistance thermometer, the temperature-susceptible part of which consists of a gold coating applied by evaporation under high vacuum and electrolytically strengthened. After overcoming initial difficulties, calibration of plugs up to and beyond 400 degrees C was possible. The measurements were made on high-speed internal combustion engines. The increasing effect of carbon deposit at the wall surface with increasing operating period is indicated by means of charts.

Meier, Adolph↗

Chemisorption studies of Pt/SnO2 catalysts

The low temperature CO oxidation catalysts that are being developed and tested at NASA-Langley are fairly unique in their ability to efficiently oxidize CO at low temperatures (approx. 303 K). The bulk of the reaction data that has been collected in the laboratory has been determined using plug flow reactors with a low mass of Pt/SnO2/SiO2 catalyst (approx. 0.1 g) and a modest flow rate (5 to 10 sc sm). The researchers have previously characterized the surface solely in terms of N2 BET surface areas. These surface areas have not been that indicative of reaction rate. Indeed, some of the formulations with high BET surface area have yielded lower reaction rates than those with lower BET surface areas. As a result researchers began a program of determining the chemisorption of the various species involved in the reaction; CO, O2 and CO2. Such a determination of will lead to a better understanding of the mechanism and overall kinetics of the reaction. The pulsed-reactor technique, initially described by Freel, is used to determine the amount of a particular molecule that is adsorbed on the catalyst. Since there is some reaction of CO with the surface to produce CO2, the pulsed reactor had to be coupled with a gas chromatograph in order to distinguish between the loss of CO that is due to adsorption by the surface and the loss that is due to reaction with the surface.

Brown, Kenneth G.↗

Plug cluster module demonstration

The low pressure, film cooled rocket engine design concept developed during two previous ALRC programs was re-evaluated for application as a module for a plug cluster engine capable of performing space shuttle OTV missions. The nominal engine mixture ratio was 5.5 and the engine life requirements were 1200 thermal cycles and 10 hours total operating life. The program consisted of pretest analysis; engine tests, performed using residual components; and posttest analysis. The pretest analysis indicated that operation of the operation of the film cooled engine at O/F = 5.5 was feasible. During the engine tests, steady state wall temperature and performance measurement were obtained over a range of film cooling flow rates, and the durability of the engine was demonstrated by firing the test engine 1220 times at a nominal performance ranging from 430 - 432 seconds. The performance of the test engine was limited by film coolant sleeve damage which had occurred during previous testing. The post-test analyses indicated that the nominal performance level can be increased to 436 seconds.

Rousar, D. C.↗

The 10 to the 8th power bit solid state spacecraft data recorder

The results are summarized of a program to demonstrate the feasibility of Bubble Domain Memory Technology as a mass memory medium for spacecraft applications. The design, fabrication and test of a partially populated 10 to the 8th power Bit Data Recorder using 100 Kbit serial bubble memory chips is described. Design tradeoffs, design approach and performance are discussed. This effort resulted in a 10 to the 8th power bit recorder with a volume of 858.6 cu in and a weight of 47.2 pounds. The recorder is plug reconfigurable, having the capability of operating as one, two or four independent serial channel recorders or as a single sixteen bit byte parallel input recorder. Data rates up to 1.2 Mb/s in a serial mode and 2.4 Mb/s in a parallel mode may be supported. Fabrication and test of the recorder demonstrated the basic feasibility of Bubble Domain Memory technology for such applications. Test results indicate the need for improvement in memory element operating temperature range and detector performance.

Murray, G. W.↗

Effects of via-conductor geometry in the electromigration failure of Al:Cu wires

Electromigration (EM) experiments conducted using two types of via/plug to conductor alignment indicate a geometrical dependence of electromigration failure in Al:Cu conductors. The resistance vs time curves show distinctive steps when the alignment is parallel. This is explained by a successive loss of conductivity through the plug due to void formation. In the perpendicular via/conductor arrangement, resistance increases by smaller and closely spaced steps. EM experiments without vias, found that the conductor life under stress increases by at least an order of magnitude. Kinetic studies at four temperatures between 180-240 C found activation energies to be 1.0 plus or minus 0.1eV.

Al:Cu accelerated testing electromigration activat↗

Bayesian Inference and the Effects of Varying Uncertainty Models in Charring Ablator Calibration and Uncertainty Quantification Problems

The Mars Science Laboratory (MSL) vehicle utilized a heat shield constructed from NASA’s Phenolic-Impregnated Carbon Ablator (PICA) material to protect the main structure from the high enthalpy environment encountered during hypersonic atmospheric entry. During the vehicle’s descent through Martian atmosphere, multiple thermocouples embedded within the heat shield captured in-depth material temperature data that allow for studies to be conducted on current material response reconstruction tools. In the present work, material temperature data obtained from thermocouples within the MISP-4 plug (MEDLI (Mars Science Laboratory Entry, Descent, and Landing Instrument) Integrated Sensor Plug) are utilized in the calibration of Theoretical Ablative Composite for Open Testing (TACOT) model parameters in conjunction with NASA’s Porous material Analysis Toolbox (PATO) through Bayesian inference where uncertainty due to parametric, modeling, and experimental sources is simultaneously quantified. Prior to the study, a sensitivity analysis is performed through computation of the robust Sobol indices in an effort to study the relationship between input space and model response and to reduce the dimensionality of the statistical inverse problem. The Bayesian inference methodology necessitates an a-priori choice to be made for the uncertainty model for which numerous possibilities are available. Across most works, however, only basic additive or multiplicative models are utilized with pre-defined magnitudes of uncertainty based on a-priori knowledge or to-be-calibrated multipliers of static covariance matrix structures. The present effort explores the effects of informed uncertainty models, ones with temporal dependence that are simultaneously calibrated through Bayesian inference, on calibrated results for parameters that make up the uncertain input space.

Sensitivity Analysis↗

Coke Deposition and Smoke Formation in Turbojet Engines

In the early development of jet engines, it was occasionally found that excessive amounts of coke or other carbonaceous deposits were formed in the combustion chamber. Sometimes a considerable amount of smoke was noted in the-exhaust gases. Excessive coke deposits may adversely affect jet-engine performance in several ways. The formation of excessive amounts of coke on or just downstream of a fuel nozzle (figs. 116(a) and (b)) changes the fuel-spray pattern and possibly affects combustor life and performance. Similar effects on performance can result from the deposition of coke on primary-air entry ports (fig. 116(c)). Sea-level or altitude starting may be impaired by the deposition of coke on spark-plug electrodes (fig. 116(b)), deposits either grounding the electrodes completely or causing the spark to occur at positions other than the intended gap. For some time it was thought that large deposits of coke in turbojet combustion chambers (fig. 116(a)) might break away and damage turbine blades; however, experience has indicated that for metal blades this problem is insignificant. (Cermet turbine blades may be damaged by loose coke deposits.) Finally, the deposition of coke may cause high-temperature areas, which promote liner warping and cracking (fig. 116(d)) from excessive temperature gradients and variations in thermal-expansion rates. Smoke in the exhaust gases does not generally impair engine performance but may be undesirable from a tactical or a nuisance standpoint. Appendix B of reference 1 and references 2 to 4 present data obtained from full-scale engines operated on test stands and from flight tests that indicate some effects on performance caused by coke deposits and smoke. Some information about the mechanism of coke formation is given in reference 5 and chapter IX. The data indicate that (1) high-boiling fuel residuals and partly polymerized products may be mixed with a large amount of smoke formed in the gas phase to account for the consistency, structure, and chemical composition of the soft coke in the dome and (2) the hard deposits on the liner are similar to petroleum coke and may result from the liquid-phase thermal cracking of the fuel. During the early development period of jet engines, it was noted that the excessive coke deposits and exhaust smoke were generally obtained when fuel-oil-type fuels were used. Engines using gasoline-type fuels were relatively free from the deposits and smoke. These results indicated that some type of quality control would be needed in fuel specifications. Also noted was the effect of engine operating conditions on coke deposition. It is possible that, even with a clean-burning fuel, an excessive amount of coke could be formed at some operating conditions. In this case, combustor redesign could possibly reduce the coke to a tolerable level. This chapter is a summary of the various coke-deposition and exhaust-smoke problems connected- with the turbojet combustor. Included are (1) the effect of coke deposition on combustor life or durability and performance; (2) the effect of combustor design, operating conditions, inlet variables, and fuel characteristics on coke deposition; (3) elimination of coke deposits; (4) the effect of operating conditions and fuel characteristics on formation of exhaust smoke; and (5) various bench test methods proposed for determining and controlling fuel quality.

Hibbard, R. R.↗

Some preliminary results of brush seal/rotor interference effects on leakage at zero and low RPM using a tapered-plug rotor

Some preliminary brush seal leakage results for ambient temperature air are presented. Data for four nominal brush rotor radial clearances of -0.09, -0.048, -0.008, and 0.035 mm were taken by using a tapered plug rotor at 0 and 400 rpm with rotor runout of 0.127 mm peak to peak. The brush seal nominal bore diameter was 38 mm with 0.05 mm bristles at 200 bristles/mm of circumference and a 0.61 mm fence height. Leakages were greater than predicted, but agreement was reasonable. Leakage rates were not significantly altered by hysteresis or inlet flow variations. Visualization studies showed that the bristles followed the 400 rpm excitation, and loading studies indicated that bristles slid relative to one another.

Hendricks, R. C.↗

Some preliminary results of brush seal/rotor interference effects on leakage at zero and low rpm using a tapered-plug rotor

Some preliminary brush seal leakage results for ambient-temperature air are presented. Data for four nominal brush-rotor radial clearances of -0.09, -0.048, -0.008, and 0.035 mm were taken by using a tapered plug rotor at 0 and 400 rpm with rotor runout of 0.127 mm peak to peak. The brush seal nominal bore diameter was 38 mm with 0.05-mm bristles at 200 bristles/mm of circumference and a 0.61-mm fence height. Leakages were greater than predicted, but agreement was reasonable. Leakage rates were not significantly altered by hysteresis or inlet flow variations. Visualization studies showed that the bristles followed the 400-rpm excitation, and loading studies indicated that bristles slid relative to one another.

Hendricks, R. C.↗

The effects of trace impurities in coal-derived liquid fuels on deposition and accelerated high temperature corrosion of cast superalloys

The effects of trace metal impurities in coal-derived liquids on deposition, high temperature corrosion and fouling were examined. Alloys were burner rig tested from 800 to 1100 C and corrosion was evaluated as a function of potential impurities. Actual and doped fuel test were used to define an empirical life prediction equation. An evaluation of inhibitors to reduce or eliminate accelerated corrosion was made. Barium and strontium were found to limit attack. Intermittent application of the inhibitors or silicon additions were found to be effective techniques for controlling deposition without losing the inhibitor benefits. A computer program was used to predict the dew points and compositions of deposits. These predictions were confirmed in deposition test. The potential for such deposits to plug cooling holes of turbine airfoils was evaluated. Tests indicated that, while a potential problem exists, it strongly depended on minor impurity variations.

Lowell, C. E.↗

Velocity Characteristics of Evaporated Plasma using Hinode/EIS

This paper presents a detailed study of chromospheric evaporation using the EUV Imaging Spectrometer (EIS) onboard Hinode in conjunction with HXR observat,ions from RHESSI. The advanced capabilities of EIS were used to measure Doppler shifts in 15 emission lines covering the temperature range T=0.05-16 MK during the impulsive phase of a C-class flare on 2007 December 14. Blueshifts indicative of the evaporated material were observed in six emission lines from Fe XIV-XXIV (2-16 MK). Upflow velocity was found to scale with temperature as v(sub up) (kilometers per second) approximately equal to 5-17 T (MK). Although the hottest emission lines, Fe XXIII and Fe XXIV, exhibited upflows of greater than 200 kilometers per second, their line profiles were found to be dominated by a stationary component in stark contrast to the predictions of the standard flare model. Emission from O VI-Fe XIII lines (0.5-1.5 MK) was found to be redshifted by v(sub down) (kilometers per second) approximately equal to 60-17 T (MK) and was interpreted as the downward-moving 'plug' characteristic of explosive evaporation. These downflows occur at temperatures significantly higher than previously expected. Both upflows and downflows were spatially and temporally correlated with HXR emission observed by RHESSI that provided the properties of the electron beam deemed to be the driver of the evaporation. The energy contained in the electron beam was found to be greater than or equal to 10(sup 11) ergs per square centimeter per second consistent with the value required to drive explosive chromospheric evaporation from hydrodynamic simulations.

Milligan, Ryan O.↗

Technical Evaluation Motor 3 (TEM-3)

A primary objective of the technical evaluation motor program is to recover the case, igniter and nozzle hardware for use on the redesigned solid rocket motor flight program. Two qualification objectives were addressed and met on TEM-3. The Nylok thread locking device of the 1U100269-03 leak check port plug and the 1U52295-04 safe and arm utilizing Krytox grease on the barrier-booster shaft O-rings were both certified. All inspection and instrumentation data indicate that the TEM-3 static test firing conducted 23 May 1989 was successful. The test was conducted at ambient conditions with the exception of the field joints (set point of 121 F, with a minimum of 87 F at the sensors), igniter joint (set point at 122 F with a minimum of 87 F at sensors) and case-to-nozzle joint (set point at 114 F with a minimum of 87 F at sensors). Ballistics performance values were within specification requirements. Nozzle performance was nominal with typical erosion. The nozzle and the case joint temperatures were maintained at the heaters controlling set points while electrical power was supplied. The water and the CO2 quench systems prevented damage to the metal hardware. All other test equipment performed as planned, contributing to a successful motor firing. All indications are that the test was a success, and all expected hardware will be refurbished for the RSRM program.

Garecht, Diane↗

Qualification Motor no. 8 (QM-8), volume 1

All inspection and instrumentation data indicate that the QM-8 static test firing conducted 20 January 1989 was successful. Ambient temperature at T-0 was 28 F. With two flights successfully accomplished, this final test in the redesigned solid rocket motor (RSRM) program certified that the design meets motor performance requirements under extreme cold conditions. This test was a prerequisite to the third flight. The entire test article was cold conditioned at 20 to 25 F for approximately 31 days to assure a maximum propellant mean bulk temperature (PMBT) of 40 F, making it the lowest PMBT in the history of the program. This extreme condition also presented the opportunity to certify critical components at low temperatures. Certification of field joint and igniter heaters, adhesive bondline integrity, flex bearing performance, flight instrumentation performance, RSRM seal performance, and LSC and nozzle plug performance was accomplished. Prior to motor ignition, the field joints were maintained between 75 to 130 F, the igniter-to-case joint was maintained between 75 to 123 F, and the case-to-nozzle joint was maintained between 75 to 120 F. QM-8 was tested with induced side loads to simulate the strut loads experienced during ignition and maximum aerodynamic loading conditions. The ability of the safe and arm device to change position from safe-to-arm and arm-to-safe was certified. Ballistics performance was certified at the lower limits. Values were within specification requirements. Nozzle performance was nominal with typical erosion. The use of Fiberite carbon-cloth phenolic was certified. The water deluge system, CO2 quench, and other test equipment performed as planned during all required test operations.

Garecht, D. M.↗

Effect of Molding and Machining on Neoflon CTFE M400H Polychlorotrifluoroethylene Rod Stock and Valve Seat Properties

Since 1997 numerous fires have been reported to the Food and Drug Administration involving cylinder valves installed on medical use oxygen cylinders sold and operated within the United States. All of the cylinder valves in question had polychlorotrifluoroethylene (PCTFE) valve seats. Subsequent failure analysis showed that the main seat was the primary source of ignition. A review of the incidents involving cylinder valve fires indicated three possible ignition mechanisms: contaminant promotion, flow friction, and resonance. However, gas purity analysis showed that uncombusted, residual oxygen was within specification. Infrared and energy dispersive spectroscopy further showed that no contaminants or organic compounds were present in the remaining, uncombusted valve seat material or on seat plug surfaces. Therefore, contaminant-promoted ignition did not appear to be responsible for the failures. Observations of extruded material along the outer edge of the coined or loaded seat area produced by cylinder overuse or poppet overload led to concerns that accelerated gas flow across a deformed seat surface could generate enough localized heating to ignite the polymeric seat. Low molecular weight or highly amorphous quick-quenched PCTFE grades might be expected to be especially prone to this type of deformation. Such a failure mechanism has been described as flow friction; however, the corresponding mechanistic parameters are poorly understood. Subsequent revelation of low-temperature dimensional instability by thermomechanical analysis (TMA) in a variety of PCTFE sheet and rod stock samples led to new concerns that PCTFE valve seats could undergo excessive expansion or contraction during service. During expansion, additional extrusion and accompanying flow friction could occur. During contraction, a gap between the seal and adjacent metal surfaces could form. Gas flowing past the gap could, in turn, lead to resonance heating and subsequent ignition as described in ASTM Guide for Evaluation Nonmetallic Materials for Oxygen Service (G 63). Attempts to uncover the origins of the observed dimensional instability were hindered by uncertainties about resin grade, process history, and post-process heat history introduced by machining, annealing, and sample preparation. An approach was therefore taken to monitor property changes before and after processing and machining using a single, well-characterized lot of Neoflon CTFE.1 M400H resin. A task group consisting of the current PCTFE resin supplier, two molders, and four valve seat manufacturers was formed, and phased testing on raw resin, intermediate rod stock, and finished valve seats initiated. The effect of processing and machining on the properties of PCTFE rod stock and oxygen gas cylinder valve seats was then determined. Testing focused on two types of extruded rod stock and one type of compression-molded rod stock. To accommodate valve seat manufacturer preferences for certain rod stock diameters, two representative diameters were used (4.8 mm (0.1875 in.) and 19.1 mm (0.75 in.)). To encompass a variety of possible sealing configurations, seven different valve seat types with unique geometries or machining histories were tested. The properties investigated were dimensional stability as determined by TMA, specific gravity, differential scanning calorimetry (DSC), compressive strength, zero strength time, and intrinsic viscosity. Findings are discussed in the context of polymer structure-process-property relationships whenever possible.

Waller, Jess M.↗

Turbojet-engine Starting and Acceleration

From considerations of safety and reliability in performance of gas-turbine aircraft, it is clear that engine starting and acceleration are of utmost importance. For this reason extensive efforts have been devoted to the investigation of the factors involved in the starting and acceleration of engines. In chapter III it is shown that certain basic combustion requirements must be met before ignition can occur; consequently, the design and operation of an engine must be tailored to provide these basic requirements in the combustion zone of the engine, particularly in the vicinity of the ignition source. It is pointed out in chapter III that ignition by electrical discharges is aided by high pressure, high temperature, low gas velocity and turbulence, gaseous fuel-air mixture, proper mixture strength, and-an optimum spark. duration. The simultaneous achievement of all these requirements in an actual turbojet-engine combustor is obviously impossible, yet any attempt to satisfy as many requirements as possible will result in lower ignition energies, lower-weight ignition systems, and greater reliability. These factors together with size and cost considerations determine the acceptability of the final ignition system. It is further shown in chapter III that the problem of wall quenching affects engine starting. For example, the dimensions of the volume to be burned must be larger than the quenching distance at the lowest pressure and the most adverse fuel-air ratio encountered. This fact affects the design of cross-fire tubes between adjacent combustion chambers in a tubular-combustor turbojet engine. Only two chambers in these engines contain spark plugs; therefore, the flame must propagate through small connecting tubes between the chambers. The quenching studies indicate that if the cross-fire tubes are too narrow the flame will not propagate from one chamber to another. In order to better understand the role of the basic factors in actual engine operation, many investigations have been conducted in single combustors from gas-turbine engines and in full-scale engines in altitude tanks and in flight. The purpose of the present chapter is to discuss the results of such studies and, where possible, to interpret these results qualitatively in terms of the basic requirements reported in chapter III. The discussion parallels the three phases of turbojet engine starting: (1) Ignition of the fuel-air mixture (2) Propagation of flame throughout the combustion zone (3) Acceleration of the engine to operating speed.

Mc Cafferty, R. J.↗

Variance Decomposition of MEDLI2 Reconstructed Heating Using Neural Networks

The Mars Entry, Descent, and Landing Instrumentation (MEDLI2) sensor suite collected data during entry of the Mars 2020 Perseverance rover into Mars’ atmosphere. This suite included a network of MEDLI2 Instrumented Sensor Plugs (MISPs). Each MISP was comprised of a cylinder made of Thermal Protection System (TPS) material with 1-3 embedded thermocouples (TCs), and it was flush mounted into the heatshield or backshell. Data from these in-depth TCs were used to reconstruct the aeroheating environment of the vehicle throughout entry. Surface heating was posed as an inverse problem, with the goal of estimating the surface heating by minimizing an objective function of the difference between MISP temperature measurements during flight and the temperature predictions derived from the Fully Implicit Ablation and Thermal response (FIAT) program. Given an aerothermal environment, FIAT calculates the material response and provides in-depth temperatures throughout the TPS material. To achieve the reverse, an internal tool called FIAT_Opt runs through multiple different environments until the output temperature at the TC depth closely matches the flight data. 95% confidence intervals on the reconstructed surface heating were obtained using Monte Carlo analysis, in which uncertainties in the thermocouple depth and the TPS material properties (e.g., density, thermal conductivity, heat capacity, emissivity) based on flight-lot material testing were included. A variance decomposition method using Sobol indices was employed to assess the sensitivity of the reconstructed peak heating to the TC placement and material property uncertainties. Variance decomposition was found to require tens of thousands of FIAT_Opt runs in order for the Sobol indices to converge. With a single FIAT_Opt run taking on the order of 40 minutes, the required number of computations would take months to complete, even if using multiple CPUs. To mitigate this problem, three machine learning models (ridge regression with cross-validation, random forest regression, and a deep neural network) were trained and tested using the 2000 Monte Carlo runs that were already completed. A subset of 1600 runs were used to train the model (i.e., training set), while the remaining 400 runs were used as the test set. The predictions from the deep neural network (DNN) on the test set showed nearly perfect agreement to the actual values computed with FIAT_Opt (R2 > 0.99). Using the DNN as a surrogate model, the variance decomposition using 50,000 runs was completed within minutes. The resulting Sobol indices showed that the reconstructed peak surface heating was most sensitive to the uncertainties in the thermal conductivity (ST = 0.37) and heat capacity (ST = 0.26). This method can be leveraged to provide requirements for material property measurements needed to improve the accuracy of surface heating prediction and ultimately lead to the reduction of design margins in the future. This presentation will include background on the MEDLI2 suite; the method used for inverse heating estimation; the way that material property uncertainties were accounted for using Monte Carlo analysis; a brief background on variance decomposition; the motivation for using machine learning in this context; how a neural network was trained on the data to enable variance decomposition in a fraction of the time; and the variance decomposition results for one of the MISPs.

Hannah Alpert↗

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the non-liquid-level-sensing temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode . a known function of the current and temperature . is measured as an indication of its temperature. For the purpose of this measurement, "small electric current" signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired locations along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode a known function of the current and temperature is measured as an indication of its temperature. For the purpose of this measurement, small electric current signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when the diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired location along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗