Search NASA⌕ Search

SEARCH · Search NASA

Results for “polymer degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Understanding PV Polymer Backsheet Degradation through X-Ray Scattering

Understanding how photovoltaic (PV) module backsheet polymers age and degrade in response to environmental stresses is important for designing polymers that can maintain their structural integrity after decades of outdoor use. X-ray scattering is a powerful technique for exploring backsheet polymer structure at the angstrom- (wide-angle, WAXS) and nanometer- (small-angle, SAXS) length-scales. We present the use of SAXS and WAXS to study pristine and aged polymer backsheets. The structural insight from these techniques can be used to compare the degradation induced by accelerated testing with the degradation seen in field-aged PV materials.

14 SOLAR ENERGY↗

Analytical methods for toxic gases from thermal degradation of polymers

Toxic gases evolved from the thermal oxidative degradation of synthetic or natural polymers in small laboratory chambers or in large scale fire tests are measured by several different analytical methods. Gas detector tubes are used for fast on-site detection of suspect toxic gases. The infrared spectroscopic method is an excellent qualitative and quantitative analysis for some toxic gases. Permanent gases such as carbon monoxide, carbon dioxide, methane and ethylene, can be quantitatively determined by gas chromatography. Highly toxic and corrosive gases such as nitrogen oxides, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and sulfur dioxide should be passed into a scrubbing solution for subsequent analysis by either specific ion electrodes or spectrophotometric methods. Low-concentration toxic organic vapors can be concentrated in a cold trap and then analyzed by gas chromatography and mass spectrometry. The limitations of different methods are discussed.

Hsu, M.-T. S.↗

Accelerated Testing Of Photothermal Degradation Of Polymers

Electron-spin-resonance (ESR) spectroscopy and Arrhenius plots used to determine maximum safe temperature for accelerated testing of photothermal degradation of polymers. Aging accelerated by increasing illumination, temperature, or both. Results of aging tests at temperatures higher than those encountered in normal use valid as long as mechanism of degradation same throughout range of temperatures. Transition between different mechanisms at some temperature identified via transition between activation energies, manifesting itself as change in slope of Arrhenius plot at that temperature.

Kim, Soon Sam↗

Effect of cavitation on fluid stability in polymer thickened fluids and lubricants

The effects of cavitating flow on the polymeric additives used in functional fluids are described. A comparison of thermal and mechanical stability tests for these polymer solutions show distinct differences in the machanism of the polymer degradation. The thermal degradation tests appear to cause an unzippering or depolymerization type of reaction in which there is no particular selectivity based on molecular weight. The mechanical degradation of these fluids appears to be based on molecular weight. Measurements of molecular weight distributions during mechanical degradation show that for a given level of intensity only molecules above a certain minimum size are degraded. The effects of ultrasonic radiation on polymer degradation are reported. Tests were conducted to demonstrate the mechanism of mechanical polymer degradiation in an orifice. A more severe test than the orifice test in which two tapered roller bearings loaded against each other produce the mechanical breakdown is discussed.

Duda, J. L.↗

Nanoconfinement-induced shift in photooxidative degradation pathway of polystyrene

Polymer nanocomposites with high concentrations of nanoparticles (NPs) possess exceptional mechanical, transport, and thermal properties. To enable their widespread use in structural applications and functional coatings, it is crucial to understand how nanoconfinement and the polymer-NP interface influence polymer degradation under various environmental conditions, including prolonged UV exposure. In this study, we investigate the photooxidative degradation of polystyrene (PS)-confined in the interstices of SiO 2 NP films. These nanocomposite films are prepared by the capillary rise infiltration (CaRI) of PS into interstices of SiO 2 NP packings, and subsequently subjected to UV irradiation. Our investigation reveals that PS degradation progresses uniformly across the thickness, with degradation initiating from the center of the NP interstitial pores and extending towards the NP surface. We rationalize this degradation mechanism based on the disparity in the surface energies of PS and the NP surface, as well as slow oxygen diffusion through confined PS. Here, we also demonstrate that packing smaller NPs at a given thickness or thicker packing of a specific NP size facilitates photooxidative degradation, highlighting the critical role of the number of interstitial pores in influencing degradation processes.

36 MATERIALS SCIENCE↗

Thermosetting Phthalocyanine Polymers

Group of phthalocyanine polymers resist thermal degradation. Polymers expected semiconducting. Principal applications probably in molded or laminated parts that have to withstand high temperatures. Polymers made from either of two classes of monomer: Bisphthalonitriles with imide linkages or Bisphthalonitriles with ester-imide linkages.

Fohlen, G.↗

ESR Analysis of Polymer Photo-Oxidation

Electron-spin resonance identifies polymer-degradation reactions and their kinetics. New technique enables derivation of kinetic model of specific chemical reactions involved in degradation of particular polymer. Detailed information provided by new method enables prediction of aging characteristics long before manifestation of macroscopic mechanical properties.

Kim, Soon Sam↗

Facility and Methods Developed for Simulated Space Vacuum Ultraviolet Exposure Testing of Polymer Films

Vacuum ultraviolet (VUV) radiation of wavelengths between 115 and 200 nm produced by the Sun in the space environment can degrade polymer films, producing changes in their optical, mechanical, and chemical properties. These effects are particularly important for thin polymer films being considered for ultralightweight space structures, because, for most polymers, VUV radiation is absorbed in a thin surface layer. The NASA Glenn Research Center has developed facilities and methods for long-term ground testing of polymer films to evaluate space environmental VUV radiation effects. VUV exposure can also be used as part of combined or sequential simulated space environmental exposures to determine combined damaging effects with other aspects of the space environment, which include solar ultraviolet radiation, solar flare x-rays, electron and proton radiation, atomic oxygen (for low-Earth-orbit missions), and temperature effects. Because the wavelength sensitivity of VUV damage is not well known for most materials, Glenn's VUV facility uses a broad-spectrum deuterium lamp with a magnesium fluoride window that provides output between 115 and 200 nm. Deuterium lamps of this type were characterized by the National Institute of Standards and Technology and through measurements at Glenn. Spectral irradiance measurements show that from approximately 115 to 160 nm, deuterium lamp irradiance can be many times that of air mass zero solar irradiance, and as wavelength increases above approximately 160 nm, deuterium lamp irradiance decreases in comparison to the Sun. The facility is a cryopumped vacuum chamber that achieves a system pressure of approximately 5310(exp -6) torr. It contains four individual VUV-exposure compartments in vacuum, separated by water-cooled copper walls to minimize VUV radiation and any sample contamination cross interactions between compartments. Each VUV-exposure compartment contains a VUV deuterium lamp, a motor-controlled sample stage coupled with a moveable cesium iodide VUV phototube, and two thermocouples for temperature measurement. The vacuum chamber and exterior equipment is shown. Each VUV lamp is located at the top of the chamber with its projection-tube pushed through an O-ring compression fitting. The lamp assemblies are located on ports that can be isolated from the rest of the vacuum chamber, permitting maintenance or replacement of the lamps without breaking vacuum in the main chamber where the samples are located. A view of two of the four interior VUV-exposure compartments, including the moveable sample stages and detector holders is also shown. Glenn is using this facility to support testing of Next Generation Space Telescope sunshield materials that is being led by the NASA Goddard Space Flight Center and to develop an understanding of the wavelength, intensity, and temperature dependence of VUV-induced polymer degradation.

Dever, Joyce A.↗

Towards directed energy deposition of metals using polymer-based supports: porosity of 316L stainless steel deposited on carbon-fiber-reinforced ABS

Directed energy deposition (DED) is increasingly valuable to many industries because of its high deposition rates relative to other metal additive manufacturing processes, but the design space of DED is limited. For instance, steep overhangs are difficult or impossible to manufacture. Polymer-based support structures could help address this challenge. The viability of DED on polymer composite substrates has begun to be explored, specifically with 316L stainless steel on carbon-fiber-reinforced ABS substrates. Monolithic metal components can be deposited on the polymer, but it was found that gas release during polymer degradation causes porosity due to gas entrapment in the metal. An interlayer cooling time was introduced to reduce polymer degradation and decrease the porosity due to gas entrapment, but this led to porosity from lack of fusion. The results of this work provide insight into process parameter selection and scan strategy development to enable the use of polymer support structures in blown-powder DED.

Kurfess, Rebecca↗

Effect of Environments on Parametric Degradation in Polymer Tantalum Capacitors

Chip polymer tantalum capacitors (CPTCs) are more sensitive to environments compared to conventional, MnO2 cathode capacitors. Contrary to MnO2 capacitors, CPTCs can degrade with time of storage even in dry conditions, that might limit their use for space applications. Performance of CPTCs depends on the amount of moisture in the slug, and varies with time of storage after manufacturing. For this reason, characteristics of the parts and qualification testing should be carried out after preconditioning to stabilize moisture content. This work analyzes kinetics of moisture sorption and desorption in different types of CPTCs from three manufacturers. Variations of capacitance, dissipation factor, ESR, and leakage currents caused by exposure to humid, dry, and radiation environments are discussed. Examples of the effects of long-term exposure to vacuum and humid environments at 85%RH are presented. Temperature dependencies of the characteristic times of moisture diffusion allow for assessments of the bake-out times that are necessary to avoid pop-corning failures after soldering and to precondition parts before qualification testing.

Teverovsky, Alexander↗

First principles modeling of polymer encapsulant degradation in Si photovoltaic modules

An outstanding issue in the longevity of photovoltaic (PV) modules is the accelerated degradation caused by the presence of moisture. Moisture leads to interfacial instability, de-adhesion, encapsulant decomposition, and contact corrosion. However, experimental characterization of moisture in PV modules is not trivial and its impacts can take years or decades to establish in the field, presenting a major obstacle to designing high-reliability modules. First principles calculations provide an alternative way to study the ingress of water and its detrimental effect on the structure and decomposition of the polymer encapsulant and interfaces between the encapsulant and the semiconductor, the metal contacts, or the dielectric layer. Here, we use density functional theory (DFT) computations to model single chain, crystalline and cross-linked structures, infrared (IR) signatures, and degradation mechanisms of ethylene vinyl acetate (EVA), the most common polymer encapsulant used in Si PV modules. IR-active modes computed for low energy EVA structures and possible decomposition products match well with reported experiments. The EVA decomposition energy barriers computed using the Nudged Elastic Band (NEB) method show a preference for acetic acid formation as compared to acetaldehyde, are lowered in the presence of a water solvent or hydroxyl ion catalyst, and match well with reported experimental activation energies. This systematic study leads to a clear picture of the hydrolysis-driven decomposition of EVA in terms of energetically favorable mechanisms, possible intermediate structures, and IR signatures of reactants and products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RESIN: Responsible Innovation for Highly Recyclable Plastics - TASK 4: Risk Assessment Framework

This report covers the entirety of Task 4, but its main purpose is to deliver milestones ML4.4 and ML4.5, the last two SOPO milestones under Task 4. ML4.4 reports on the compatibility of polymer properties that affect both environmental performance and functional performance and the tradeoffs involved in turning these properties to the benefit of each. ML4.5 presents a complete set of information on the critical properties of benign target products, where benign products are defined as those with the shortest environmental lifetime which meet performance requirements. To support and provide context to the discussions of ML4.4 and ML4.5 and to provide a complete picture of Task 4, milestones 4.1-4.3 are briefly summarized at the beginning of the report. The discussion of ML4.4 introduces the notion of polymer persistence as a proxy for environmental risk. It then discusses the development and comparison of two machine leaning models explored for estimating polymer degradation rates, a random forest (RF) classifier and an RF regressor. Given the advantage of continuous outputs rather than simple classes, the RF regressor was incorporated in the Excel risk calculator, which to this point could implement the objectives of subtasks 4.1-4.3, estimating polymer release and redistribution. The ML4.4 discussion then addresses the effect of each of the three polymer features used by the RF regressor on polymer functional performance. These features are number molecular weight (Mn), glass transition temperature (T g ) and heat of fusion (H fus ). The discussion of ML4.5 reviews the conceptual framework of the risk model, which served as the foundation for developing the Excel risk calculator and describes the use of, and assumptions within, the calculator. Appendix A is further provided as a user’s guide for the calculator. To demonstrate how the calculator is intended to be used by developers in the design of low-risk polymers, an analysis of 27 hypothetical polymers defined by varying values for the three polymer features used by the RF regressor is presented. The range of parameter values selected produces estimates of polymer degradation rates and lifetimes that may be typical of various consumer products made from polyurethane polymers and shows how changes in polymer features affect lifetimes. The demonstration also predicts the final distribution of released polymer materials in environmental compartments as a function of consumer product mix and assumed leakage rates of end-of-life processes. Lastly, this report summarizes the achievement of Task 4 goals from original conception to final delivery and discusses how and to what degree to which each subtask goal was achieved.

36 MATERIALS SCIENCE↗

Dose Rate Effects on Degradation of Nuclear Power Plant Electrical Cable Insulation at a Common Dose

The intent of this report is to address an identified knowledge gap in relating accelerated aging of nuclear electrical cables to service aging: dose rate effects (DRE). Here, DRE refer to gamma radiation-induced polymer degradation being a function of dose rate in addition to total absorbed dose. The concern raised is that historical qualification conducted at higher dose rates to simulate service lifetime may underestimate insulation degradation that occurs at lower dose rates in service. In the work described herein, common nuclear cable insulation materials—cross-linked polyethylene (XLPE) and ethylene propylene diene elastomer (EPDM)—were subjected to accelerated aging at ambient temperature (26°C) at different gamma dose rates of 100, 200 and 1800 Gy/h for select exposure durations to achieve constant total doses of 170, 210 and 300 kGy to evaluate DRE. First, the cable insulation material types investigated are described. Then, the accelerated aging experimental process involving gamma irradiation applied to the insulation specimens at room temperature and different dose rates is discussed. Then, the experimental characterization techniques used to perform this work are elucidated. These include elongation at break (EAB), mass change, yellowness index (YI), carbonyl index (CI), density, indenter modulus (IM), and relaxation constant (t). Theory of polymer degradation is discussed, and characterization results and discussion are provided. Finally, concluding remarks are made. The findings from this work and cited prior work reveal that DRE are material dependent, even between similar material categories (e.g., XLPE). In the case of the EPDM studied, degradation of ductility was observed to be greater at higher dose rate for the same total dose, indicating accelerated gamma aging to be more conservative than extended aging. Thus, conclusions regarding the conservatism of historical qualification likely require additional consideration for specific materials and conditions in question. The results of this study support the contention that, due to inherent limitations and uncertainties associated with prediction of cable remaining useful life from accelerated aging experiments, trending of installed cable insulation health status will be more practical and useful for safe and efficient cable aging management repair and replace decisions than lifetime prediction from historical qualification. The combination of material robustness demonstrated by the qualification process and ongoing monitoring of cable health status combine to provide confidence in continued safe use of existing nuclear cables. Additional research into effective and efficient condition monitoring methods for non-destructive evaluation of installed cables is needed to support aging cable management, including material studies to inform interpretation of measured results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

X-Ray Absorption near Edge Structure Spectroscopic Study of Hayabusa Category 3 Carbonaceous Particles

Analyses with a scanning transmission x-ray microscope (STXM) using x-ray absorption near edge structure (XANES) spectroscopy were applied for the molecular characterization of two kinds of carbonaceous particles of unknown origin, termed category 3, which were collected from the Hayabusa spacecraft sample catcher. Carbon-XANES spectra of the category 3 particles displayed typical spectral patterns of heterogeneous organic macromolecules; peaks corresponding to aromatic/olefinic carbon, heterocyclic nitrogen and/or nitrile, and carboxyl carbon were all detected. Nitrogen-XANES spectra of the particles showed the presence of N-functional groups such as imine, nitrile, aromatic nitrogen, amide, pyrrole, and amine. An oxygen-XANES spectrum of one of the particles showed a ketone group. Differences in carbon- and nitrogen-XANES spectra of the category 3 particles before and after transmission electron microscopic (TEM) observations were observed, which demonstrates that the carbonaceous materials are electron beam sensitive. Calcium-XANES spectroscopy and elemental contrast mapping identified a calcium carbonate grain from one of the category 3 particles. No fluorine-containing molecular species were detected in fluorine-XANES spectra of the particles. The organic macromolecular features of the category 3 particles were distinct from commercial and/or biological ‘fresh (non-degraded)’ polymers, but the category 3 molecular features could possibly reflect degradation of contaminant polymer materials or polymer materials used on the Hayabusa spacecraft. However, an extraterrestrial origin for these materials cannot currently be ruled out.

Asteroides↗