Search NASA⌕ Search

SEARCH · Search NASA

Results for “position measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A beam profile and position measurement system for the IPF target

Currently one determines the size and position of the proton beam at the IPF target using plastic films. These films are installed in a target carrier, lowered into position, exposed to the beam, raised back up to the hot cell, removed from the target carrier, and assessed via a video feed. About an hour is required for each cycle of measurement. Because of this high cost in terms of time the users usually settle for a beam that is good enough to meet their needs, but not as good as they would like. I propose here a diagnostic device that would enable a measurement of under two seconds. This would enable delivery of a better-quality beam in less time.

43 PARTICLE ACCELERATORS↗

Simultaneous Momentum and Position Measurement and the Instrumental Weyl-Heisenberg Group

The canonical commutation relation, [Q,P]=iℏ, stands at the foundation of quantum theory and the original Hilbert space. The interpretation of P and Q as observables has always relied on the analogies that exist between the unitary transformations of Hilbert space and the canonical (also known as contact) transformations of classical phase space. Now that the theory of quantum measurement is essentially complete (this took a while), it is possible to revisit the canonical commutation relation in a way that sets the foundation of quantum theory not on unitary transformations but on positive transformations. This paper shows how the concept of simultaneous measurement leads to a fundamental differential geometric problem whose solution shows us the following. The simultaneous P and Q measurement (SPQM) defines a universal measuring instrument, which takes the shape of a seven-dimensional manifold, a universal covering group we call the instrumental Weyl-Heisenberg (IWH) group. The group IWH connects the identity to classical phase space in unexpected ways that are significant enough that the positive-operator-valued measure (POVM) offers a complete alternative to energy quantization. Five of the dimensions define processes that can be easily recognized and understood. The other two dimensions, the normalization and phase in the center of the IWH group, are less familiar. The normalization, in particular, requires special handling in order to describe and understand the SPQM instrument.

47 OTHER INSTRUMENTATION↗

The study of high-frequency pick-ups for electron beam position measurements in the AWAKE common beamline

The common beamline of the AWAKE experiment at CERN involves the co-propagation of two particle beams: protons with 48 nC bunch charge and 250 ps bunch length, and electrons with up to 600 pC bunch charge and approximately 4 ps bunch length. The existing operational beam position monitors at AWAKE cannot measure the electron bunches whilst the more-intense proton bunches are present, due to their low operating frequency. In order to try to address this challenge, two different types of high-frequency pick-ups were studied, a conical-shaped button pick-up and a Cherenkov diffraction radiation-based pick-up designed to operate at around 30 GHz. Both devices were installed at AWAKE and were connected to two identical read-out systems designed by TRIUMF. This contribution presents and discusses the results obtained from beam-based measurements during the current experimental year.

43 PARTICLE ACCELERATORS↗

Position measurements for heavy ion beams using a sodium iodide scintillator

A 50 cm diameter, 1.7 cm thick disc of NaI scintillator has been mounted to permit edge viewing by four photomultipliers. Energetic heavy ions passing through the scintillator at different positions cause a variation in the division of light among the photomultipliers. A performance close to the expected limit for 670 MeV/n neon has been achieved. Calculations of expected response using an optical model agree well with the measurements.

Buffington, A.↗

Electrical instrument measures position and velocity of shock waves

Instrument employs a sensor consisting of twin-electrode probe mounted in shock tube wall, with small dc voltage impressed across electrodes. Power supply, amplifier, and gate pulse generator complete the system. Instrument provides data for construction of wave diagrams, as well as measurement of shock velocity.

Dannenberg, R. E.↗

An automated technique for stellar magnitude, color index, and position measurements of astronomical photographs

Computer programs have been developed for use in collecting and processing data from a PDS scanning microdensitometer. The goal is to obtain fast and simple algorithms for handling an entire astronomical photograph with one-pass digitization. This capability is realized by a real-time detection scheme that provides a data compression of a factor of 100, and a processing program that produces a catalog of magnitudes, color indices, and positions for up to 90,000 multicolor stellar images.

Green, R. F.↗

Optical position measurement for a large gap magnetic suspension system: Design and performance analysis

An optical measurement system (OMS) has been designed and tested for a large gap magnetic suspension system (LGMSS). The LGMSS will be used to study control laws for magnetic suspension systems for vibration isolation and pointing applications. The LGMSS features six degrees of freedom and consists of a planar array of electromagnets that levitate and position a cylindrical element containing a permanent magnet core. The OMS provides information on the location and orientation of the element to the LGMSS control system to stabilize suspension. The hardware design of this optical sensing system and the tracking algorithms are presented. The results of analyses and experiments are presented that define the accuracy limits of the optical sensing system and that quantify the errors in position estimation.

Welch, Sharon S.↗

Wide field of view laser beacon system for three-dimensional aircraft position measurement

This paper presents a new wide field of view laser beacon system for measurement, in three dimensions, of aircraft or other remote objects. The system is developed for aircraft collision hazard warning independent of ground-based hardware, as well as for flight research, helicopter-assisted construction and rescue, and robotic manipulation applications. Accurate information describing the relative range, elevation, and azimuth of the aircraft are generated by the sweep of a low-power fan-shaped rotating laser beacon past an array of optical detectors. The system achieves a wide angle of acceptance of laser beacon light through use of compound parabolic concentrators, which collimate the light for spectral filtering to minimize solar interference. An on-board microprocessor system converts the pulse sequence to aircraft position in real time. System reliability and performance are enhanced through narrow pass filtering of the pulse signals, digital logic design to mask spurious signals, and adaptive modulation of trigger threshold levels.

Sweet, L. M.↗

Precise position measurements of Jupiter, Saturn and Uranus systems with the Very Large Array

VLBI observations of the Jovian satellites Europa, Ganymede, and Callisto obtained in 1983, of Titan obtained in 1984, and of Uranus obtained in 1985, all with the VLA at 15 GHz, are used to determine the ephemerides. The results are presented graphically, and it is found that the standard ephemeris reference frame for the outer planets is in error by about -200 marcsec in right ascension.

Muhleman, D. O.↗

Extension of synthetic estimation filters for relative position measurements

The construction of synthetic estimation filters (SEF) for out-of-plane rotation is reported. When images corresponding to rotations between the angles which were used to construct the estimator were input to the simulator, the yaw measurement accuracy was a little better than one-half of a degree over the five degree range. If individual phase-only filters were used and the only criteria for yaw angle was 'best correlation', 11 filter would be required for the same range and accuracy. The technique proposed here is invariant to translation.

Monroe, Stanley E., Jr.↗

Application of Global Positioning Measurements to Continental Collision in the Pamir-Tien Shan Region, Central Asia and GPS Survey of the Western Tien Shan

In this report, we summarize what we have accomplished with five years of funding from NASA under its DOSE program, and with a comparable level of funding from NSF. We describe the development of a GPS network in the Tien Shan of Kyrgyzstan and Kazakhstan of the former Soviet Union, the analysis of data, and the main results. This discussion presents the state of the current network, which has grown significantly since the termination of our DOSE grants, with continued support both from NSF through its continental dynamics program and from NASA's SENH program. Although grants from NASA's DOSE program did not support this growth not directly, it did so indirectly by building the infrastructure that has enabled further expansion in an area where otherwise there would be only a small GPS presence. We note how the network has grown over time, but the emphasis of this discussion is on the quantity and quality of measurements that we have made.

Hamburger, Michael W.↗

Combined position and diameter measures for lunar craters

The note addresses the problem of simultaneously measuring positions and diameters of circular impact craters on wide-angle photographs of approximately spherical planets, such as the moon and Mercury. The method allows for situations in which the camera is not aligned on the planet's center.

Arthur, D. W. G.↗

Use of global positioning system measurements to determine geocentric coordinates and variations in Earth orientation

Geocentric tracking station coordinates and short-period Earth-orientation variations can be measured with Global Positioning System (GPS) measurements. Unless calibrated, geocentric coordinate errors and changes in Earth orientation can lead to significant deep-space tracking errors. Ground-based GPS estimates of daily and subdaily changes in Earth orientation presently show centimeter-level precision. Comparison between GPS-estimated Earth-rotation variations, which are the differences between Universal Time 1 and Universal Coordinated Time (UT1-UTC), and those calculated from ocean tide models suggests that observed subdaily variations in Earth rotation are dominated by oceanic tidal effects. Preliminary GPS estimates for the geocenter location (from a 3-week experiment) agree with independent satellite laser-ranging estimates to better than 10 cm. Covariance analysis predicts that temporal resolution of GPS estimates for Earth orientation and geocenter improves significantly when data collected from low Earth-orbiting satellites as well as from ground sites are combined. The low Earth GPS tracking data enhance the accuracy and resolution for measuring high-frequency global geodynamical signals over time scales of less than 1 day.

R P Malla↗