Search NASA⌕ Search

SEARCH · Search NASA

Results for “post combustion carbon capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis of energetics and economics of sub-ambient hybrid post-combustion carbon dioxide capture

Adsorption of CO 2 from post-combustion flue gas is one of the leading candidates for globally impactful carbon capture systems. In this report, work focused on understanding the opportunities and limitations of sub-ambient CO 2 capture processes utilizing a multistage separation process. A hybrid process design using a combination of pressure-driven separation of CO 2 from flue gas (e.g., adsorption- or membrane-based separation) followed by CO 2 -rich product liquefaction to produce high-purity (>99%) CO 2 at pipeline conditions is considered. The operating pressure of the separation unit is a key cost parameter and also an important process variable that regulates the available heat removal necessary to reach the sub-ambient operating conditions. The economic viability of applying pressure swing adsorption (PSA) processes using fiber sorbent contactors with internal heat management was found to be most influenced by the productivity of the adsorption system, with productivities as high as 0.015 mol CO2 /kg sorb -1 sec -1 being required to reduce costs of capture below $60/ton CO 2 captured. This analysis was carried out using a simplified two-bed process, and thus there is opportunity for further cost reduction with exploration of more complex cycle designs. Three exemplar fiber sorbents (MIL-101(Cr), UiO-66, and zeolite 13X) were considered for application in the sub-ambient process of PSA unit. Among the considered sorbents, zeolite 13X fiber composites were found to perform better at ambient temperatures as compared to sub-ambient. MIL-101(Cr) and UiO-66 fiber composites had improved purity, recovery, and productivity at colder temperatures reducing costs of capture as low as $61/ton CO 2 . Future economic improvement could be achieved by reducing the required operating pressure of the PSA unit and pushing the Pareto frontier closer to the final pipeline requirement via a combination of PSA cycle design and material selection.

42 ENGINEERING↗

Energy-efficient carbon capture from industrial point sources via commercially available green solvent and hollow fiber membrane contactors

Solvent-based absorption systems have emerged in the carbon capture space due to their high absorption capacities, reusability, and favorable energy requirements. Using diethyl sebacate as a solvent for pre- and post-combustion carbon capture has advantages over other solvents, including high hydrophobicity, low viscosity, low vapor pressure, high CO 2 solubility, high CO 2 selectivity, and being commercially available in large quantities. Despite these advantageous properties, the use of diethyl sebacate as a solvent for post-combustion carbon capture has not been studied in detail. To examine the capability of diethyl sebacate, a scalable, energy-efficient, hollow fiber membrane (microporous polypropylene and polyvinylidene fluoride) contactor (HFMC)-based process with low-cost and high surface area is investigated. A purity of 95.3 % CO 2 with 46 % recovery in one absorption stage was achieved, with a permeate flux over one magnitude greater than using a deep eutectic solvent in the same system. Technoeconomic analysis determined a ∼ 0.8 GJ per ton of CO 2 at a processing cost of ∼$93 per ton of CO 2 . Results from this work underscore the potential for utilizing green solvents in HFMC-based separation processes for effective carbon capture and provide a pathway towards practical deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Filer City Biomass Carbon Removal and Storage (BiCRS) Net-Negative Study

NorthStar Clean Energy Company (NorthStar) conducted the Filer City Biomass Carbon Removal and Storage (BiCRS) Net-Negative Study to develop a conceptual design and cost estimate for retrofitting the TES Filer City Station with post-combustion carbon capture technology in Mainstee Michigan. The Filer City BiCRS Net-Negative Study allowed NorthStar and team to confirm the commercial feasibility of a post-combustion carbon capture system applied to biomass-fired boilers. At the time of the study, there were no operating facilities in the world with carbon capture applied to flue gas from woody biomass as proposed for Filer City. Due to the solvent-agnostic nature of B&W’s SolveBright™ technology, the team determined that multiple amines, both traditional and proprietary, would be capable of 95% CO 2 capture efficiency with the steam available from Filer City’s existing boilers after modifications to burn 100% biomass. Based on the cost estimates produced, NorthStar can now confirm the Filer City BiCRS Project is economically viable with a combination of tax credits available from the Inflation Reduction Act of 2022 and high-quality Carbon Dioxide Removal Credits sold on the Voluntary Carbon Market. The Filer City BiCRS project is uniquely positioned to become one of the first projects to capture and sequester large volumes of CO 2 from a biogenic source, removing existing CO 2 from the atmosphere. The unlimited version of the Filer City Biomass Carbon Removal and Storage (BiCRS) Net-Negative Study Final Technical Report is attached.

01 COAL, LIGNITE, AND PEAT↗

Oxygen Solubility in Aqueous Amine Solvents with Common Additives Used for CO 2 Chemical Absorption

Major sources of anthropogenic CO 2 are power generation and transportation industries where researcher continue to explore CO 2 emission mitigation strategies as applied to these CO 2 sources through carbon capture, utilization, and sequestration (CCUS). The most mature CO 2 capture technology is post-combustion carbon capture (PCCC) using aqueous amine solutions/solvents, however solvent degradation and regeneration costs are slowing the widespread adoption of PCCC. Solvent degradation of the aqueous amine solutions is mainly caused from the temperature gradient between the absorber and stripper columns and common flue gas components such as SOx, NOx, and oxygen (O 2 ). The two main classifications of solvent degradation are thermal degradation, occurring when the amine reacts with itself at elevated temperatures and anaerobic conditions and oxidative degradation. Oxidative degradation reactions can occur from oxygen mass transfer and free radical oxidation. Metals, such as iron from the corrosion of steel structures used in industrial applications such as PCCC, can help to catalyze these reactions. Various oxidative degradation studies have shown how O 2 concentrations in flue gas and, to a lesser extent, temperature influence the extent of oxidative degradation. Accurately measuring the O 2 solubility, commonly referred to as dissolved oxygen (DO), in a quick, continuous, and efficient manner in aqueous amine solvents should contribute to determine the effectiveness of mitigation strategies for oxidative degradation. Knowing that commercial PCCC amine solvents contain components beyond water, amine, carbonate species and CO 2 , this investigation was conducted to determine the oxygen solubility changes of common aqueous amines solutions with commonly used and published solvent additives. The impact of carbon loadings with and without the additives was also examined. A commercial dissolved oxygen probe was used to measure the DO concentrations and compared them against standard Winkler Method titration values. The results show that antifoam shows minimal change in [DO]. MBT yielded lower DO values, and NaVO 3 showed a higher DO concentration due to interferences. These results indicate that most common amine solvent additives should be expected to minimally impact oxygen solubility and amine oxidative degradation.

60 APPLIED LIFE SCIENCES↗

Recent developments on polymeric membranes for CO 2 capture from flue gas

Polymeric membranes have been widely considered as one of the next-generation technologies for CO 2 capture from fossil fuel-derived flue gases. This separation modality requires novel polymeric materials that possess efficient CO 2 /N 2 separation properties, as well as chemical and mechanical stability for a multiyear membrane lifetime. In this paper, recent developments in polymeric membranes tailored for post-combustion carbon capture are reviewed. The selected polymeric materials encompass ether oxygen-rich polymers, polynorbornenes, ionic liquid membranes, and facilitated transport membranes. In each of the selected materials, noteworthy research efforts for material design and membrane formation are highlighted. The performances of the selected materials are compared in the CO 2 /N 2 selectivity-CO 2 permeance plot. As the only class of materials reviewed herein that have demonstrated the fabrication of thin-film composite membranes in scale, facilitated transport membranes have shown both high selectivity and permeance at relevant conditions for post-combustion carbon capture. Finally, comprehensive field tests are needed to resolve the technical gap between the material development and the commercial application.

20 FOSSIL-FUELED POWER PLANTS↗

Generating Emissions Inventory for Carbon Capture and Storage Analysis for Carbon-Intensive Industrial Sectors

Decarbonizing the industrial sector is critical to achieve carbon dioxide (CO2) emissions reductions goals of the Biden Administration. Currently available decarbonization options include electrification, fuel switching to zero carbon fuels like green hydrogen (H2) and carbon capture and storage (CCS). Application of post-combustion carbon capture (PCCC) technology in the power sector, as well as research at the U.S. Department of Energy's Fossil Energy and Carbon Management (FECM) Office has shown that its application in the industrial sector could have co-benefits in the form of emissions reductions of non-CO2 regulated pollutants. For example, solvent based PCCC systems require pre-conditioning of flue gas to remove sulfur and particulate matter (PM) upstream of the CO2 absorber. However, there is a lack of understanding about the type of non-CO2 pollutants which can be captured and the amount of reduction possible. PCCC application differs across industrial sectors as it depends on the availability of decarbonization options, characteristics of industrial processes and the amount and composition of pollutant flows. Certain facilities can also have multiple effluent flows with or without a CO2 stream. As such, understanding industrial processes and their effluent flows in detail is required to quantify the co-benefits opportunities presented by PCCC. Considering this requirement, the goal of this analysis is to develop a high-resolution inventory of effluent flows from facilities of 8 industrial sectors in the U.S. These industrial sectors - ethanol, ammonia, cement, steel, natural gas processing, hydrogen, petroleum refining and wood and pulp products - have carbon-intensive effluent flows, and thus are prime candidates for PCCC applications. In this study, we map the composition of pollutant flow from flue stacks across the identified facilities. Using data available in three Environmental Protection Agency (EPA) databases - the Green House Gas Reporting Program (GHGRP), the National Emissions Inventory (NEI) and the Toxic Release Inventory (TRI), we create a combined inventory which lists the type, amount, and concentration of pollutant flows. Using total weight of the pollutant flow back calculated from observed data for CO2 concentrations in flue gas for individual sectors, we calculate the concentration of each pollutant in the flue gas stream. Thus, the resultant emissions inventory includes the following details for each facility in the sector: facility-level and if possible, process-level pollutant flows, concentrations of pollutants in the flue gas, and geographical coordinates of the facilities. A detailed statistical analysis and summary allows us to search for erroneous data and remove them from the final inventory. The generation of the inventory is achieved using a python-based framework which can recreate this inventory for other industrial sectors as well as using newer releases of emission inventories from EPA. The statistical analysis performed on the inventory is also calibrated and automated to identify outliers efficiently.

air pollutants↗

Techno-economic evaluation of emission control configurations for AMP/PZ-based post-combustion CO 2 capture

Minimizing the environmental impacts of amine-based post-combustion carbon capture technologies is essential for regulatory compliance and public acceptance. Experimental campaigns at RWE's CO 2 capture pilot plant in Niederaussem using CESAR1 demonstrated that combining existing emission abatement technologies can substantially reduce the concentration of amines and degradation products in the CO 2 -depleted flue gas to below the detection limit of an infrared spectrometer. The campaign confirmed that a proprietary dry bed technology (OEASE aerozone™) or a second water wash can reduce AMP and PZ emissions to below 1 mg/Nm 3 . However, an acid or chemically active wash downstream of the water wash is necessary to reduce NH 3 emissions to very low levels (<2 mg/Nm 3 ). Combining a dry bed with an acid wash significantly reduces both the required acid solution and the resulting acid waste. The techno-economic analysis indicates that implementing emission mitigation technologies provides substantial environmental benefits for the CESAR1 process, with only a marginal increase (<1 €/tCO 2 ) in both the carbon capture cost (CCC) and CO 2 avoidance cost (CAC). The additional capital cost associated with extra column packing is offset by operational cost savings from reduced solvent losses. For stringent emission permits targeting NH 3 , a configuration combining a dry bed upstream of the water wash followed by an acid wash achieves the best balance between emission control and cost efficiency. This configuration results in a Levelized Cost of Electricity (LCOE) of 143 €/MWh, a CCC of 45.4 €/tCO 2 , and a CAC of 88.4 €/tCO 2 .

AMP↗