Search NASA⌕ Search

SEARCH · Search NASA

Results for “power electronic converter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering↗

Robust Model Predictive Control for Attack Mitigation of Virtual Synchronous Generators (VSGs) in an Islanded Microgrid

With the increasing application of power converters in distributed energy systems, power electronics converters face an increasing number of cyber-attacks. To mitigate the cyber-attack impact on voltage source converters (VSCs) and microgrids, a robust model predictive control (RMPC) is proposed for virtual synchronous generators (VSG) in an islanded microgrid. This RMPC is designed to compensate for the frequency deviations, thus maintaining frequency stability of the whole islanded microgrid against cyber threats. Finally, to verify the feasibility of the proposed method, comparisons between the proposed method and the conventional VSC controller are provided in different attack scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantification of storage required for preserving frequency security in wind‐integrated systems

Abstract The penetration of wind power generation into the power grid has been accelerated in recent times due to the aggressive emission targets set by governments and other regulatory authorities. Although wind power has the advantage of being environment‐friendly, wind as a resource is intermittent in nature. In addition, wind power contributes little inertia to the system as most wind turbines are connected to the grid via power electronic converters. These negative aspects of wind power pose serious challenges to the frequency security of power systems as penetration increases. In this work, an approach is proposed where an energy storage system (ESS) is used to mitigate frequency security issues of wind‐integrated systems. ESSs are well equipped to supply virtual inertia to the grid due to their fast‐acting nature, thus replenishing some of the energy storage capability of displaced inertial generation. In this work, a probabilistic approach is proposed to estimate the amount of inertia required by a system to ensure frequency security. Reduction in total system inertia due to the displacement of conventional synchronous generation by wind power generation is considered in this approach, while also taking into account the loss of inertia due to forced outages of conventional units. Monte Carlo simulation is employed for implementing the probabilistic estimation of system inertia. An ESS is then sized appropriately, using the system swing equation, to compensate for the lost inertia. The uncertainty associated with wind energy is modeled into the framework using an autoregressive moving average technique. Effects of increasing the system peak load and changing the wind profile on the expected system inertia are studied to illustrate various factors that might affect system frequency security. The proposed method is validated using the IEEE 39‐bus test system.

17 WIND ENERGY↗

Introduction of a Variable Inductance Transformer for the Design of Resonant Power Converters

Magnetic integration is a hot topic in power electronics that concerns the use of a transformer’s leakage and magnetizing inductances purposefully in isolated power electronic converters, thereby giving the opportunity to save the cost and footprint of any additional inductor. This is of prime interest, especially in CLLLC resonant converters which require up to three inductors. For a complete integration of these inductances, the concept of a variable inductance transformer (VIT) is introduced in this thesis. A VIT is an adaptive magnetic structure that facilitates an easy adjustment of both magnetizing and leakage inductances to meet their desired values. However, for a more promising design, an accurate estimation of these inductances is necessary. While the evaluation of magnetizing inductance is quite straightforward, the calculation of leakage inductance is rather convoluted, because the leakage inductance is influenced by both the winding layout and the operating frequency. In this thesis, three new semi-analytical methods for calculating the frequency-independent leakage inductance, and a novel semi-analytical method for evaluating the frequency-dependent leakage inductance are proposed. These methods can calculate the respective leakage inductances of a VIT within an outstanding ±5% uncertainty. Finally, a bidirectional CLLLC resonant dc-dc converter is investigated for the constant current constant voltage (CCCV) charging of the next-generation 900 V traction battery of an electric vehicle. A new voltage gain equation is derived for designing the CLLLC resonant tank, and a small-signal model is presented for designing the variable-frequency feedback controller. Furthermore, a new methodology to design a VIT is developed to overcome the challenges associated with small coupling coefficients and guarantee a complete magnetic integration of the tank inductances. All theoretical results presented herein are verified through simulations and experiments performed on hardware prototypes designed in the lab.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advancing Dynamic Modeling of Grid-Connected PV Inverter Using Bi-LSTM-Based AI Model

Power electronic converters (PECs) are widely used in modern power systems to facilitate the interconnection between various AC or DC sources and loads. Because of the extensive integration, the power system has grown into a more dynamic system in which the dynamics of the PECs must be adequately modeled. The paper presents a new bidirectional long short-term memory (Bi-LSTM) method for evaluating grid-connected inverter-based resources (IBR) dynamics. The method is tested using real hardware data from a grid -connected commercial inverter in laboratory experiments. Results show the Bi-LSTM model accurately reproduces the detailed IBR model's dynamics, even when the internal structure is unknown and parameters are unknown, preventing the disclosure of the manufacturer's confidential data.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

Advanced control techniques for modern inertia based inverters

In this research three artificial intelligent (AI)-based techniques are proposed to regulate the voltage and frequency of a grid-connected inverter. The increase in the penetration of renewable energy sources (RESs) into the power grid has led to the increase in the penetration of fast-responding inertia-less power converters. The increase in the penetration of these power electronics converters changes the nature of the conventional grid, in which the existing kinetic inertia in the rotating parts of the enormous generators plays a vital role. The concept of virtual inertia control scheme is proposed to make the behavior of grid connected inverters more similar to the synchronous generators, by mimicking the mechanical behavior of a synchronous generator. Conventional control techniques lack to perform optimally in nonlinear, uncertain, inaccurate power grids. Besides, the decoupled control assumption in conventional VSGs makes them nonoptimal in resistive grids. The neural network predictive controller, the heuristic dynamic programming, and the dual heuristic dynamic programming techniques are presented in this research to overcome the draw backs of conventional VSGs. The nonlinear characteristics of neural networks, and the online training enable the proposed methods to perform as robust and optimal controllers. The simulation and the experimental laboratory prototype results are provided to demonstrate the effectiveness of the proposed techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Cyber-Attack Detection for PV Farms via Time-Frequency Domain Features

The internetworking of grid-connected power electronics converters (PECs) in photovoltaic (PV) farms has inevitably expanded the cyber-attack surfaces. Here this paper presents a comprehensive study on cyber-attack detection and diagnosis for PEC-enabled PV farms via single waveform sensor to distinguish between normal conditions, open-circuit faults, short-circuit faults, and cyber-attacks. To our knowledge, this has not been attempted before. Firstly, we propose frequency-domain magnitude-based residuals to identify short-circuit faults and a time-domain mean current vector-based feature to distinguish open-circuit faults from other threats. These features can fully reflect the specific physical characteristics of PV farms during threat duration. Secondly, unlike micro phasor measurement units (µPMU) and raw electric waveform-based methods, the proposed innovative features can address novel cyber-attacks that are excluded from the training process. Thirdly, an online hardware-in-the-loop (HIL) testbed using the OPAL-RT real-time digital simulator has verified the effectiveness. The monitoring system runs in real-time while using HIL as an operational solar farm and a National Instruments (NI) data acquisition card as the electric waveform sensor at the point of coupling.

42 ENGINEERING↗

Foreword: Special Section on Multiphysics Aspects of Power Electronics Packaging—Power Die, Power Module, and Converter Level: Part 2

Power electronics are increasingly being used to condition electricity for a wide array of applications, such as transportation (on land, air, and water), data centers, radio frequency, directed energy, wind, solar, and grid-tied applications. Here, to increase power density, performance, efficiency, and reliability-as well as to reduce cost-innovations and developments are needed in the multiphysics packaging of power electronics at a die, module, and converter level. This includes fundamental R&D related to emerging high-voltage, high-temperature, and high-switching-frequency power electronics, packaging materials, thermal materials and interfaces, fluid-based thermal management technologies, reliability, condition monitoring, and prognostics. Latest developments in this area are published as a Special Section on Multiphysics Aspects of Power Electronics Packaging. The first part was published in the May 2024 issue of the IEEE Transactions on Components, Packaging and Manufacturing Technology (Volume 14, Issue 5). The second part of that Special Section is being published in this issue. A brief summary of the papers included in the second part are given below.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Hardware Platform for Studying Naval Power Electronic Power Distribution Systems

Abstract – Future intelligent ship system designs will likely include electric propulsion, numerous highpower sensors, and directed energy weapons. Supply and control of these large nonlinear loads will require a networked, multi-converter power electronic power distribution system. This work presents a hardware platform to emulate a microgrid power system with multiple power converters and a power data communication network. The platform is reconfigurable and can include both AC and DC power distribution zones, representative of shipboard power systems. It also allows for the study of both power control actuation and power data communication delays. Since the platform is based on electric power hardware, spatial and temporal uncertainties are inherently embedded in the system. Specifically, this work examines the control actuation of multiple pulsed power loads in a single microgrid. Several pulse load levels and operating scenarios have been implemented and measured. A framework for control parameter quantification is presented, and various metrics are explored to capture pulse signal characteristics. The sensitivity of pulse load metric parameters is analyzed. Dynamic shipboard, mission-specific load profiles coupled with pulse loads can also be emulated in the hardware platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium Voltage Converter Inductor Insulation Design Considering Grid Requirements

Medium voltage (MV) SiC devices facilitate direct (without 50-/60-Hz transformer) connection of the power electronics converter to the MV grid using simple topology. Compared to the insulation design of MV inductors that have been widely used in the power system, the insulation design of the MV converter filter inductors has new challenges. Particularly, the grid impact on insulation requirements on converter filter inductors is rarely discussed. This article introduces the insulation design of a grid-side filter inductor for a 13.8-kV power conditioning system converter. The grid insulation requirements, including the short-duration power frequency overvoltage and the lightning impulse voltage, are considered in the design. To meet the requirements, the layer-to-layer insulation, winding-to-core/ground insulation, the air gap discharge between the winding and the core, the local electric field, as well as the interturn transient voltage distribution are considered. Furthermore, the designed inductors are validated by the 46 kV (>1 min) dc hi-pot test, 12-kV ac partial discharge test, one-hour single-phase converter full rating test, as well as three-phase converter full rating test.

42 ENGINEERING↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗

Synchronous Wind: Evaluating the Grid Impact of Inverterless Grid-Forming Wind Power Plants

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. This paper develops the generic model of synchronous wind power generators, also known as Type-5 wind turbines, for power system integration studies. The Type-5 wind turbine interfaces with the electric grid through a synchronous generator; hence, its operation and consequent grid impacts are similar to a conventional power plant. Based on the developed model, a Type-5 wind power plant is integrated into the IEEE 14-bus test bed to evaluate its control and operation with a bulk power system. Finally, the stability properties of Type-5 wind turbine generators are compared with Type-3 wind turbines in GFM control mode through impedance characterization.

grid strength↗

Operating Wind Turbine as Synchronous Generator: Modeling and Power-Hardware-in-the-Loop Demonstration

Grid-forming (GFM) control of Type 3 and Type 4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also referred to as a Type 5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type 5 WTG interfaces with the electric grid via a synchronous generator driven by a variable speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type 5 WTG in a power-hardware-in-the-loop testing environment, and it presents its operation characteristics under different grid contingencies. The power-hardware-in-the-loop demonstration shows that a Type 5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power response, wind rotor dynamics, and stability enhancement compared to a Type 3 WTG in GFM control mode. Furthermore, the paper provides further insight into how Type 5 WTGs can support the smooth transition to power systems with high integration levels of inverter-based resources.

17 - WIND ENERGY↗

Synchronous Wind: Evaluating the Grid Impact of Inverterless Grid-Forming Wind Power Plants: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators have attracted substantial attention in power system research. However, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. This paper developed the generic model of synchronous wind power generators, also known as Type-5 wind turbines, for the power system integration studies. The Type-5 wind turbine interface to the grid through a synchronous generator; hence, its operation and consequent grid impacts are similar to a conventional power plant. Based on the developed model, a Type-5 wind power plant is integrated into IEEE 14-bus testbed to evaluate its control and operation with a bulk power system. Finally, the stability properties of Type-5 wind turbine generators are compared with Type-3 wind turbines in GFM control mode through impedance characterization.

grid strength↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as Type-5 wind turbine generator (WTG), offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high penetration levels of renewable generation. A Type-5 WTG interfaces to the electric grid via a synchronous generator (SG) driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation and the generator shaft remains synchronous to the grid. This paper developed and tested a high-fidelity model of Type-5 WTG under power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration showed that a Type-5 WTGs inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to Type-3 WTG in high wind conditions. The developed model also provides further insight on how Type-5 WTGs can benefit the smooth transition to power systems with high integration level of inverter-based resources.

grid strength↗

Grid and Wind Transient Ride Through Assessment of Type-5 Synchronous Wind Turbine

The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.

17 - WIND ENERGY↗

Medium Voltage Converter Inductor Insulation Design Considering Grid Insulation Requirements

Medium voltage SiC devices facilitate direct (without 50/60 Hz transformer) connection of the power electronics converter to the medium voltage grid using simple topology. Compared to the insulation design of medium voltage inductors that have been widely used in the power system, the insulation design of directly connected medium voltage converter filter inductors has more challenges. Although some works has been done discussing that, the grid insulation requirements on converter filter inductors are rarely discussed. This paper introduces the insulation design of a grid-side filter inductor for a 13.8 kV power conditioning system converter. The grid insulation requirements, including the short-duration power frequency overvoltage and the lightning impulse voltage, are considered in the design. To meet the requirements, the layer-to-layer insulation, winding-to-core/ground insulation, the air gap discharge between the winding and the core, as well as the local electrical field have been taken into consideration. Experimental tests are provided to validate the design.

Li, Haiguo↗

A Medium Voltage Testbed for the Performance and Function Tests of a 13.8 kV Power Conditioning System Converter

Medium voltage SiC devices facilitate the development of medium voltage grid-connected power electronics converters. However, it is difficult to test these converters directly on the real medium voltage grid, especially considering abnormal grid conditions, such as grid voltage and frequency variation, and different converter operation modes, such as grid-connected mode and islanded mode. This paper introduces the design and implementation of a medium voltage testbed, which supports tests of medium voltage converters in both grid-connected and islanded mode tests. In the grid-connected mode, the testbed can provide up to 13.8 kV grid voltage, can support the four-quadrant operation, and can emulate different grid conditions, such as voltage and frequency variation. In the islanded mode, the converter under test works as a voltage source and the testbed emulates a three-phase balanced or unbalanced load. Experiment test results are provided to validate the design and capability of the testbed.

Li, Haiguo↗