At least 37 records · Page 2

Benchmark Specification for FFTF LOFWOS Test #13

The Fast Flux Test Facility (FFTF) at the Hanford site in Washington was designed by the Westinghouse Electric Corporation for the U.S. Department of Energy. FFTF was a 400 MW thermal, oxide-fueled, liquid sodium cooled test reactor, built to assist development and testing of advanced fuels and materials for fast breeder reactors. After reaching criticality in 1980, FFTF operated until 1992, providing the U.S. Department of Energy (DOE) with the means to test fuels, materials, and other components in a fast neutron flux environment. In July 1986, a series of unprotected transients (with the plant protection system intentionally disabled) were performed in FFTF as part of the passive safety demonstration program. Among these were thirteen loss of flow without scram (LOFWOS) tests. The goals of this program included confirming the liquid metal reactor safety margins, providing data for computer code validation, and demonstrating the inherent and passive safety benefits of specific design features. The test defined in this benchmark is LOFWOS Test #13, which was initiated at 50% power and 100% flow with the pump pony motors turned off. This benchmark specification is intended to support collaborative efforts within international partnerships on the validation of simulation tools and models in the area of Sodium-cooled Fast Reactor (SFR) safety. Validated tools and models are needed to evaluate SFR inherent safety characteristics and assess the impact of passive design features in response to accident initiators. Comparisons with experimental data and the results of safety analyses from other groups create unique opportunities to improve predictive capabilities of computational codes and methods for SFR modeling and simulation. The conditions of the LOFWOS test along with the feedback from FFTF’s limited free bow core restraint system and the novel passive reactivity control Gas-Expansion Modules (GEMs) pose a very challenging and uniquely valuable benchmark exercise.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

H2-O2 auxiliary power unit for Space Shuttle vehicles - A progress report.

Description of a program to establish technology readiness of hydrogen-oxygen (H2-O2) auxiliary power units for use on board the Space Shuttle orbiter vehicle. Fundamental objectives include experimentally establishing an acceptable propellant flow control method, verification of combustor stability, and adequate thermal management. An initial auxiliary power unit (APU) configuration with recycled hydrogen flow has been studied and revised toward greater simplicity and scaling ease. The selected APU is a recuperated open-cycle, turbine-driven unit. Series flow of cryogenic hydrogen removes internally-generated heat and heat from the hydraulic system. The revised configuration schematic and its calculated performance are reviewed. A weight comparison is made between the shuttle baseline hydrazine and H2-O2 APU systems, showing that hydrogen-oxygen APUs have the potential of increasing the payload of the Space Shuttle.

Joyce, J. P.↗

Digital computer study of nuclear reactor thermal transients during startup of 60-kWe Brayton power conversion system

A digital computer study was made of reactor thermal transients during startup of the Brayton power conversion loop of a 60-kWe reactor Brayton power system. A startup procedure requiring the least Brayton system complication was tried first; this procedure caused violations of design limits on key reactor variables. Several modifications of this procedure were then found which caused no design limit violations. These modifications involved: (1) using a slower rate of increase in gas flow; (2) increasing the initial reactor power level to make the reactor respond faster; and (3) appropriate reactor control drum manipulation during the startup transient.

Jefferies, K. S.↗

Three-dimensional simulation of microwave-induced helium plasma under atmospheric pressure

A three-dimensional model is presented to investigate helium plasma generated by microwave under atmospheric pressure in this paper, which includes the physical processes of electromagnetic wave propagation, electron and heavy species transport, gas flow, and heat transfer. The model is based on the fluid approximation calculation and local thermodynamic equilibrium assumption. The simulation results demonstrate that the maxima of the electron density and gas temperature are 4.79 × 10{sup 17 }m{sup −3} and 1667 K, respectively, for the operating conditions with microwave power of 500 W, gas flow rate of 20 l/min, and initial gas temperature of 500 K. The electromagnetic field distribution in the plasma source is obtained by solving Helmholtz equation. Electric field strength of 2.97 × 10{sup 4 }V/m is obtained. There is a broad variation on microwave power, gas flow rate, and initial gas temperature to obtain deeper information about the changes of the electron density and gas temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

STAR FORMATION IN TURBULENT MOLECULAR CLOUDS WITH COLLIDING FLOW

Using self-gravitational hydrodynamical numerical simulations, we investigated the evolution of high-density turbulent molecular clouds swept by a colliding flow. The interaction of shock waves due to turbulence produces networks of thin filamentary clouds with a sub-parsec width. The colliding flow accumulates the filamentary clouds into a sheet cloud and promotes active star formation for initially high-density clouds. Clouds with a colliding flow exhibit a finer filamentary network than clouds without a colliding flow. The probability distribution functions (PDFs) for the density and column density can be fitted by lognormal functions for clouds without colliding flow. When the initial turbulence is weak, the column density PDF has a power-law wing at high column densities. The colliding flow considerably deforms the PDF, such that the PDF exhibits a double peak. The stellar mass distributions reproduced here are consistent with the classical initial mass function with a power-law index of –1.35 when the initial clouds have a high density. The distribution of stellar velocities agrees with the gas velocity distribution, which can be fitted by Gaussian functions for clouds without colliding flow. For clouds with colliding flow, the velocity dispersion of gas tends to be larger than the stellar velocity dispersion. The signatures of colliding flows and turbulence appear in channel maps reconstructed from the simulation data. Clouds without colliding flow exhibit a cloud-scale velocity shear due to the turbulence. In contrast, clouds with colliding flow show a prominent anti-correlated distribution of thin filaments between the different velocity channels, suggesting collisions between the filamentary clouds.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-Gaussian elliptic-flow fluctuations in PbPb collisions at s NN = 5.02 TeV

Event-by-event fluctuations in the elliptic-flow coefficient $v_2$ are studied in PbPb collisions at $\sqrt{s_{_\text{NN}}} = 5.02$ TeV using the CMS detector at the CERN LHC. Elliptic-flow probability distributions ${p}(v_2)$ for charged particles with transverse momentum 0.3$< p_\mathrm{T} <$3.0 GeV and pseudorapidity $| \eta | <$ 1.0 are determined for different collision centrality classes. The moments of the ${p}(v_2)$ distributions are used to calculate the $v_{2}$ coefficients based on cumulant orders 2, 4, 6, and 8. In conclusion, a rank ordering of the higher-order cumulant results and nonzero standardized skewness values obtained for the ${p}(v_2)$ distributions indicate non-Gaussian initial-state fluctuation behavior. Bessel-Gaussian and elliptic power fits to the flow distributions are studied to characterize the initial-state spatial anisotropy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of a High-Fidelity 4kW-Class Engineering Model PPU and Integration with HiVHAc System

The High Voltage Hall Accelerator (HiVHAc) propulsion system consists of a thruster,power processing unit (PPU), and propellant feed system. An engineering model PPU was developed by Colorado Power Electronics, Inc. funded by NASA's Small Business Innovative Research Program. This PPU uses an innovative 3-phase resonant converter to deliver 4 kW of discharge power over a wide range of input and output voltage conditions.The PPU includes a digital control interface unit that automatically controls the PPU and a xenon flow control module (XFCM). It interfaces with a control computer to receive high level commands and relay telemetry through a MIL-STD-1553B interface. The EM PPU was thoroughly tested at GRC for functionality and performance at temperature extremes and demonstrated total efficiencies a high as 95 percent. It was integrated with the HiVHAc thruster and the XFCM to demonstrate closed-loop control of discharge current with anode flow. Initiation of the main discharge and power throttling were also successfully demonstrated and discharge oscillations were characterized.

Electric Propulsion↗

Performance of a High-Fidelity 4kW-Class Engineering Model PPU and Integration with HiVHAc System

The High Voltage Hall Accelerator (HiVHAc) propulsion system consists of a thruster, power processing unit (PPU), and propellant feed system. An engineering model PPU was developed by Colorado Power Electronics, Inc. funded by NASA's Small Business Innovative Research Program. This PPU uses an innovative 3-phase resonant converter to deliver 4 kW of discharge power over a wide range of input and output voltage conditions. The PPU includes a digital control interface unit that automatically controls the PPU and a xenon flow control module (XFCM). It interfaces with a control computer to receive highlevel commands and relay telemetry through a MIL-STD-1553B interface. The EM PPU was thoroughly tested at GRC for functionality and performance at temperature limits and demonstrated total efficiencies a high as 95 percent. Integrated testing of the unit was performed with the HiVHAc thruster and the XFCM to demonstrate closed-loop control of discharge current with anode flow. Initiation of the main discharge and power throttling were also successfully demonstrated and discharge oscillations were characterized.

Power Processing Unit↗

Sensitivity study with a $\textit{D}$ and $\textit{B}$ mesons modular simulation code of heavy flavor $R_{AA}$ and azimuthal anisotropies based on beam energy, initial conditions, hadronization, and suppression mechanisms

Heavy flavor probes provide important information about the in-medium properties of the quark-gluon plasma produced in heavy-ion collisions. In this work, we investigate the effects of 2D + 1 event-by-event fluctuating hydrodynamic backgrounds on the nuclear suppression factor and momentum anisotropies of heavy flavor mesons and nonphotonic electrons. Using the state-of-the-art $\textit{D}$ and $\textit{B}$ mesons modular simulation code (called “DAB-MOD”), we perform a systematic comparison of different transport equations in the same background, including a few energy-loss models—with and without energy-loss fluctuations—and a relativistic Langevin model with different drag parametrizations. We present the resulting $\textit{D}$ and $\textit{B}$ mesons $R_{A A}, v_2, v_3,$ and $v_4$ as well as multiparticle cumulants, in AuAu collisions at $\sqrt{s_{NN}}$ = 200 GeV and PbPb collisions at $\sqrt{s_{NN}}$ = 2.76 TeV and $\sqrt{s_{NN}}$ = 5.02 TeV , and compare them to the available experimental data. The $v_2${4}/$v_2${2} ratio, which is known to be a powerful probe of the initial conditions and flow fluctuations in the soft sector, is also studied in the context of heavy flavor. We also investigate the correlations between the transverse anisotropies of heavy mesons and all charged particles to better understand how heavy quarks couple to the hydrodynamically expanding quark-gluon plasma. Finally, we study the influence that different initial conditions and the implementation of heavy-light quark coalescence has on our results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Engineering model system study for a regenerative fuel cell: Study report

Key design issues of the regenerative fuel cell system concept were studied and a design definition of an alkaline electrolyte based engineering model system or low Earth orbit missions was completed. Definition of key design issues for a regenerative fuel cell system include gaseous reactant storage, shared heat exchangers and high pressure pumps. A power flow diagram for the 75 kW initial space station and the impact of different regenerative fuel cell modular sizes on the total 5 year to orbit weight and volume are determined. System characteristics, an isometric drawing, component sizes and mass and energy balances are determined for the 10 kW engineering model system. An open loop regenerative fuel cell concept is considered for integration of the energy storage system with the life support system of the space station. Technical problems and their solutions, pacing technologies and required developments and demonstrations for the regenerative fuel cell system are defined.

Chang, B. J.↗

Growth of high-quality thin-film Ge single crystals by plasma-enhanced chemical vapor deposition

Thin-film Ge single crystals (approx. 10 microns) have been epitaxially grown on polished NaCl(100) substrates at 450C by using plasma-enhanced chemical vapor deposition. Films on approximately 1 sq cm and larger were separated from the NaCl by either melting the salt or by differential shear stress upon cooling to room temperature. The ordered growth of the Ge was found to be most sensitive to the initial plasma power and to the continuum flow dynamics within the carbon susceptor. The films were visually specular and exhibited a high degree of crysalline order when examined by X-ray diffraction. The films were found to be p-type with a carrier concentration of approximately 3 x 10 to the 16th power/cu cm, a resistivity of 0.11 ohm-cm, and a Hall hole mobility of 1820 sq cm/v/s at room temperature. Vacuum firing minimized the primary contaminant, Na, and corresponding lowered the carrier concentration to 4 x 10 to the 14th power/cu cm.

Outlaw, R. A.↗

Experimental investigation of power transient flow boiling

To advance the mechanistic understanding of power transients in flow boiling, experimental investigations are performed to capture the thermal response of four different kinds of cladding materials, including FeCrAls, to Fuchs reactivity initiated accident transients and linear ramp power transients. The transition boiling regime is phenomenologically reflected in power-transient flow boiling, which is different from steady-state boiling. In light of this, the critical heat flux that is usually featured with temperature overshooting does not indicate thermal safety margin of cladding materials as conservatively as the maximum heat flux, which is greater than critical heat flux in the power transient boiling curve. This is physically attributed to the thermal energy deposition on the cladding wall. In addition, the thermal energy released from the cladding wall results in different boiling heat transfer coefficient for the decreasing and increasing power stages respectively during the Fuchs power transient. The maximum heat flux difference gap, which appears due to changes in cladding materials and transient time scales, is appreciable under an intermediate heat convection regime. However, this difference gap is gradually weakened by the progressive increasing of mass flux and/or inlet subcooling due to the enhanced dominance of heat convection over heat conduction. Finally, the small difference gap of maximum heat flux is found to be insignificant under the weak heat convection because of power transient induced annular flow instability.

42 ENGINEERING↗

Thermal-hydraulic analyses of MIT reactor LEU transition cycles

The Massachusetts Institute of Technology Reactor (MITR) is a research reactor in Cambridge, Massachusetts designed primarily for experiments using neutron beam and in-core irradiation facilities. In the framework of non-proliferation policy, research and test reactors have started a program to convert highly enriched uranium (HEU) fuel to low-enriched uranium (LEU) fuel. A new type of LEU fuel based on a high-density alloy of uranium and molybdenum (U-10Mo) is expected to allow conversion. A transition core plan, from 22 fresh LEU fuel elements to 24 in an equilibrium state, is proposed. This study evaluates the thermal-hydraulic safety margins of each transition cycle and state (i.e. beginning, middle and end). The STAT7 and RELAP5 codes are used in the study. STAT7 provides an integrated platform for statistical propagation of uncertainties in determining steady-state thermal-hydraulic margins. A RELAP5 model was created to verify MITR's STAT7 model, and provide transient analyses. The steady-state analyses determined that, during the entire transition from a fresh to equilibrium core, the Limiting System Safety Settings (LSSS) has a 10.2% margin to the minimum power at which onset of nucleate boiling (ONB) is precluded at 3σ confidence. The loss of flow (LOF) transient, which is the most limiting anticipated transient for the MITR, was simulated. With a conservative initial state of the reactor (operating at μ + 3σ power level and LSSS mass flow rate), the maximum calculated centerline fuel temperature was 115 degrees C, which is a significantly lower value than the blistering limit of 350 degrees C. The cladding wall temperatures did not exceed the ONB temperature throughout the transient. Therefore, during LOF, no nucleate boiling is expected, precluding any critical heat flux trigger. Overall, this study indicates that the proposed LEU transition core specifications have significant margin to thermal-hydraulic limits, during steady-state operation and the LOF transient.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Temperature Split-Flow Recompression Brayton Cycle Initial Test Results

Supercritical CO 2 (S-CO 2 ) power plants offer the potential for better economics because of their small size, use of standard materials, and improved electrical power conversion efficiency at modest temperature (400–750°C). Sandia National Laboratories (SNL or Sandia) and the U.S. Department of Energy Office of Nuclear Energy (DOE-NE) are operating a supercritical CO 2 Brayton cycle power system—the Generation IV (Gen IV) split-flow S-CO 2 compressor test loop—currently located in Arvada Colorado, at Barber Nichols, Inc., under contract to Sandia. A photograph of the upgraded loop is shown in Figure E-1. This system is one of the first S-CO 2 power-producing Brayton cycles operating in the world. This report provides a summary of the newly installed hardware and briefly describes some of the test results that were performed in the upgraded split-flow Brayton loop during June and July of 2011. The Gen IV S-CO 2 split-flow Brayton loop was reconfigured to operate as a simple heated recuperated Brayton loop for the testing in this report period. The test loop had just concluded a phase of construction that substantially increased the capability of the loop by adding heaters, a high-temperature (HT) recuperator, more waste heat removal capability, high-power load banks, larger diameter piping with more bends to reduce thermal stress, and more capable scavenging pumps to reduce windage and friction within the turbomachinery and provide greater cooling capabilities. With these additions, the loop greatly increased its capacity for electrical power generation (30–80 kWe per generator, depending on the loop configuration) and its ability to reach high temperatures (up to 810 K [1000°F]). In recent weeks of testing, the test facility began to realize this potential by achieving new records in turbine inlet temperature (615 K [650°F]), shaft speed (52,000 rpm), pressure ratio (1.65), flow rate (2.7 kg/s), and electrical power generated (20 kWe). These operating conditions still remain short of design conditions for each turbine—an inlet temperature of 810 K (1000°F), a pressure ratio of 1.8, a shaft speed of 75,000 rpm, a flow rate of 3.5 kg/s, and a maximum generator power of 125 kWe—but they are beginning to be approached. Not all planned upgrades were implemented due to the limited funding profile of FY2010. Only 520 kW of heater power were installed—not the total 780 kW. Furthermore, because one of the heater controllers was not functioning, only 390 kW of heater power were available. Similarly, the 3-in. piping was installed only in the high-pressure leg of the loop, not in the low-pressure leg, as was originally planned. We also had to rely on the new load bank capability for rapid shutdown situations, and were not able to install a dedicated shutdown resistor. Nevertheless, in spite of these limitations, we operated the loop at record operating conditions and were largely limited only by the facility and support equipment—not the turbomachinery.

Wright, Steven Alan↗

Electron-cyclotron-resonance (ECR) plasma thruster research

An experimental apparatus to scientifically investigate the process of Electron-Cyclotron-Resonance (ECR) plasma acceleration has been tested. The apparatus consists of a vacuum facility, a 20 kW microwave power supply, and an argon ECR plasma thruster. Present instrumentation allows measurement of microwave input power, reflected power, propellant flow rate, and static pressure in the vacuum tank. In initial tests, an argon ECR plasma has been initiated repeatably at power levels ranging from 0.3 to 7.0 kW. The ECR plasma appears to diverge and separate from the applied magnetic field as predicted by theory. These tests suggest that the ECR plasma acceleration concept can be studied scientifically in the new apparatus.

Sercel, Joel C.↗

The influence of Hall physics on power-flow along a coaxial transmission line

Extended-MHD simulations of a coaxial transmission line are performed in axisymmetric cylindrical geometry, in particular, in examining the influence of Hall physics on a plasma layer initialized against the anode versus the cathode, for which an MHD model is insensitive. The results indicate that Hall physics is required in order to model an electron E × B drift current in the electrode plasma, which is parallel to the anode current and opposite the cathode current. This results in confinement of the electrode plasma when initialized against the cathode and expansion of the plasma layer when initialized against the anode. The expansion in the anode-initialized case results in filaments of plasma bridging the gap, causing substantial power-flow losses. These results represent the first fluid simulations of power-flow, to our knowledge, that, by including Hall physics, recover fundamental aspects of anode and cathode dynamics predicted by kinetic theory while simulating over a dynamic range (nine orders of magnitude density variation from solid-density electrodes down to low-density electrode plasma) which is prohibitive for Particle-In-Cell (PIC) codes. In conclusion, this work demonstrates the need for further development of extended-MHD and two-fluid modeling of power-flow dynamics, which, possibly through hybridization with a PIC code, will eventually culminate in a code with reliable predictive capability for power-flow coupling and energy losses in pulsed-power systems.