Search NASA⌕ Search

SEARCH · Search NASA

Results for “power flow initialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Three-dimensional simulation of microwave-induced helium plasma under atmospheric pressure

A three-dimensional model is presented to investigate helium plasma generated by microwave under atmospheric pressure in this paper, which includes the physical processes of electromagnetic wave propagation, electron and heavy species transport, gas flow, and heat transfer. The model is based on the fluid approximation calculation and local thermodynamic equilibrium assumption. The simulation results demonstrate that the maxima of the electron density and gas temperature are 4.79 × 10{sup 17 }m{sup −3} and 1667 K, respectively, for the operating conditions with microwave power of 500 W, gas flow rate of 20 l/min, and initial gas temperature of 500 K. The electromagnetic field distribution in the plasma source is obtained by solving Helmholtz equation. Electric field strength of 2.97 × 10{sup 4 }V/m is obtained. There is a broad variation on microwave power, gas flow rate, and initial gas temperature to obtain deeper information about the changes of the electron density and gas temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

STAR FORMATION IN TURBULENT MOLECULAR CLOUDS WITH COLLIDING FLOW

Using self-gravitational hydrodynamical numerical simulations, we investigated the evolution of high-density turbulent molecular clouds swept by a colliding flow. The interaction of shock waves due to turbulence produces networks of thin filamentary clouds with a sub-parsec width. The colliding flow accumulates the filamentary clouds into a sheet cloud and promotes active star formation for initially high-density clouds. Clouds with a colliding flow exhibit a finer filamentary network than clouds without a colliding flow. The probability distribution functions (PDFs) for the density and column density can be fitted by lognormal functions for clouds without colliding flow. When the initial turbulence is weak, the column density PDF has a power-law wing at high column densities. The colliding flow considerably deforms the PDF, such that the PDF exhibits a double peak. The stellar mass distributions reproduced here are consistent with the classical initial mass function with a power-law index of –1.35 when the initial clouds have a high density. The distribution of stellar velocities agrees with the gas velocity distribution, which can be fitted by Gaussian functions for clouds without colliding flow. For clouds with colliding flow, the velocity dispersion of gas tends to be larger than the stellar velocity dispersion. The signatures of colliding flows and turbulence appear in channel maps reconstructed from the simulation data. Clouds without colliding flow exhibit a cloud-scale velocity shear due to the turbulence. In contrast, clouds with colliding flow show a prominent anti-correlated distribution of thin filaments between the different velocity channels, suggesting collisions between the filamentary clouds.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-Gaussian elliptic-flow fluctuations in PbPb collisions at s NN = 5.02 TeV

Event-by-event fluctuations in the elliptic-flow coefficient $v_2$ are studied in PbPb collisions at $\sqrt{s_{_\text{NN}}} = 5.02$ TeV using the CMS detector at the CERN LHC. Elliptic-flow probability distributions ${p}(v_2)$ for charged particles with transverse momentum 0.3$< p_\mathrm{T} <$3.0 GeV and pseudorapidity $| \eta | <$ 1.0 are determined for different collision centrality classes. The moments of the ${p}(v_2)$ distributions are used to calculate the $v_{2}$ coefficients based on cumulant orders 2, 4, 6, and 8. In conclusion, a rank ordering of the higher-order cumulant results and nonzero standardized skewness values obtained for the ${p}(v_2)$ distributions indicate non-Gaussian initial-state fluctuation behavior. Bessel-Gaussian and elliptic power fits to the flow distributions are studied to characterize the initial-state spatial anisotropy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity study with a $\textit{D}$ and $\textit{B}$ mesons modular simulation code of heavy flavor $R_{AA}$ and azimuthal anisotropies based on beam energy, initial conditions, hadronization, and suppression mechanisms

Heavy flavor probes provide important information about the in-medium properties of the quark-gluon plasma produced in heavy-ion collisions. In this work, we investigate the effects of 2D + 1 event-by-event fluctuating hydrodynamic backgrounds on the nuclear suppression factor and momentum anisotropies of heavy flavor mesons and nonphotonic electrons. Using the state-of-the-art $\textit{D}$ and $\textit{B}$ mesons modular simulation code (called “DAB-MOD”), we perform a systematic comparison of different transport equations in the same background, including a few energy-loss models—with and without energy-loss fluctuations—and a relativistic Langevin model with different drag parametrizations. We present the resulting $\textit{D}$ and $\textit{B}$ mesons $R_{A A}, v_2, v_3,$ and $v_4$ as well as multiparticle cumulants, in AuAu collisions at $\sqrt{s_{NN}}$ = 200 GeV and PbPb collisions at $\sqrt{s_{NN}}$ = 2.76 TeV and $\sqrt{s_{NN}}$ = 5.02 TeV , and compare them to the available experimental data. The $v_2${4}/$v_2${2} ratio, which is known to be a powerful probe of the initial conditions and flow fluctuations in the soft sector, is also studied in the context of heavy flavor. We also investigate the correlations between the transverse anisotropies of heavy mesons and all charged particles to better understand how heavy quarks couple to the hydrodynamically expanding quark-gluon plasma. Finally, we study the influence that different initial conditions and the implementation of heavy-light quark coalescence has on our results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental investigation of power transient flow boiling

To advance the mechanistic understanding of power transients in flow boiling, experimental investigations are performed to capture the thermal response of four different kinds of cladding materials, including FeCrAls, to Fuchs reactivity initiated accident transients and linear ramp power transients. The transition boiling regime is phenomenologically reflected in power-transient flow boiling, which is different from steady-state boiling. In light of this, the critical heat flux that is usually featured with temperature overshooting does not indicate thermal safety margin of cladding materials as conservatively as the maximum heat flux, which is greater than critical heat flux in the power transient boiling curve. This is physically attributed to the thermal energy deposition on the cladding wall. In addition, the thermal energy released from the cladding wall results in different boiling heat transfer coefficient for the decreasing and increasing power stages respectively during the Fuchs power transient. The maximum heat flux difference gap, which appears due to changes in cladding materials and transient time scales, is appreciable under an intermediate heat convection regime. However, this difference gap is gradually weakened by the progressive increasing of mass flux and/or inlet subcooling due to the enhanced dominance of heat convection over heat conduction. Finally, the small difference gap of maximum heat flux is found to be insignificant under the weak heat convection because of power transient induced annular flow instability.

42 ENGINEERING↗

Thermal-hydraulic analyses of MIT reactor LEU transition cycles

The Massachusetts Institute of Technology Reactor (MITR) is a research reactor in Cambridge, Massachusetts designed primarily for experiments using neutron beam and in-core irradiation facilities. In the framework of non-proliferation policy, research and test reactors have started a program to convert highly enriched uranium (HEU) fuel to low-enriched uranium (LEU) fuel. A new type of LEU fuel based on a high-density alloy of uranium and molybdenum (U-10Mo) is expected to allow conversion. A transition core plan, from 22 fresh LEU fuel elements to 24 in an equilibrium state, is proposed. This study evaluates the thermal-hydraulic safety margins of each transition cycle and state (i.e. beginning, middle and end). The STAT7 and RELAP5 codes are used in the study. STAT7 provides an integrated platform for statistical propagation of uncertainties in determining steady-state thermal-hydraulic margins. A RELAP5 model was created to verify MITR's STAT7 model, and provide transient analyses. The steady-state analyses determined that, during the entire transition from a fresh to equilibrium core, the Limiting System Safety Settings (LSSS) has a 10.2% margin to the minimum power at which onset of nucleate boiling (ONB) is precluded at 3σ confidence. The loss of flow (LOF) transient, which is the most limiting anticipated transient for the MITR, was simulated. With a conservative initial state of the reactor (operating at μ + 3σ power level and LSSS mass flow rate), the maximum calculated centerline fuel temperature was 115 degrees C, which is a significantly lower value than the blistering limit of 350 degrees C. The cladding wall temperatures did not exceed the ONB temperature throughout the transient. Therefore, during LOF, no nucleate boiling is expected, precluding any critical heat flux trigger. Overall, this study indicates that the proposed LEU transition core specifications have significant margin to thermal-hydraulic limits, during steady-state operation and the LOF transient.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Temperature Split-Flow Recompression Brayton Cycle Initial Test Results

Supercritical CO 2 (S-CO 2 ) power plants offer the potential for better economics because of their small size, use of standard materials, and improved electrical power conversion efficiency at modest temperature (400–750°C). Sandia National Laboratories (SNL or Sandia) and the U.S. Department of Energy Office of Nuclear Energy (DOE-NE) are operating a supercritical CO 2 Brayton cycle power system—the Generation IV (Gen IV) split-flow S-CO 2 compressor test loop—currently located in Arvada Colorado, at Barber Nichols, Inc., under contract to Sandia. A photograph of the upgraded loop is shown in Figure E-1. This system is one of the first S-CO 2 power-producing Brayton cycles operating in the world. This report provides a summary of the newly installed hardware and briefly describes some of the test results that were performed in the upgraded split-flow Brayton loop during June and July of 2011. The Gen IV S-CO 2 split-flow Brayton loop was reconfigured to operate as a simple heated recuperated Brayton loop for the testing in this report period. The test loop had just concluded a phase of construction that substantially increased the capability of the loop by adding heaters, a high-temperature (HT) recuperator, more waste heat removal capability, high-power load banks, larger diameter piping with more bends to reduce thermal stress, and more capable scavenging pumps to reduce windage and friction within the turbomachinery and provide greater cooling capabilities. With these additions, the loop greatly increased its capacity for electrical power generation (30–80 kWe per generator, depending on the loop configuration) and its ability to reach high temperatures (up to 810 K [1000°F]). In recent weeks of testing, the test facility began to realize this potential by achieving new records in turbine inlet temperature (615 K [650°F]), shaft speed (52,000 rpm), pressure ratio (1.65), flow rate (2.7 kg/s), and electrical power generated (20 kWe). These operating conditions still remain short of design conditions for each turbine—an inlet temperature of 810 K (1000°F), a pressure ratio of 1.8, a shaft speed of 75,000 rpm, a flow rate of 3.5 kg/s, and a maximum generator power of 125 kWe—but they are beginning to be approached. Not all planned upgrades were implemented due to the limited funding profile of FY2010. Only 520 kW of heater power were installed—not the total 780 kW. Furthermore, because one of the heater controllers was not functioning, only 390 kW of heater power were available. Similarly, the 3-in. piping was installed only in the high-pressure leg of the loop, not in the low-pressure leg, as was originally planned. We also had to rely on the new load bank capability for rapid shutdown situations, and were not able to install a dedicated shutdown resistor. Nevertheless, in spite of these limitations, we operated the loop at record operating conditions and were largely limited only by the facility and support equipment—not the turbomachinery.

Wright, Steven Alan↗

The influence of Hall physics on power-flow along a coaxial transmission line

Extended-MHD simulations of a coaxial transmission line are performed in axisymmetric cylindrical geometry, in particular, in examining the influence of Hall physics on a plasma layer initialized against the anode versus the cathode, for which an MHD model is insensitive. The results indicate that Hall physics is required in order to model an electron E × B drift current in the electrode plasma, which is parallel to the anode current and opposite the cathode current. This results in confinement of the electrode plasma when initialized against the cathode and expansion of the plasma layer when initialized against the anode. The expansion in the anode-initialized case results in filaments of plasma bridging the gap, causing substantial power-flow losses. These results represent the first fluid simulations of power-flow, to our knowledge, that, by including Hall physics, recover fundamental aspects of anode and cathode dynamics predicted by kinetic theory while simulating over a dynamic range (nine orders of magnitude density variation from solid-density electrodes down to low-density electrode plasma) which is prohibitive for Particle-In-Cell (PIC) codes. In conclusion, this work demonstrates the need for further development of extended-MHD and two-fluid modeling of power-flow dynamics, which, possibly through hybridization with a PIC code, will eventually culminate in a code with reliable predictive capability for power-flow coupling and energy losses in pulsed-power systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computational examination of utility scale wind turbine wake interactions

We performed numerical simulations of small, utility scale wind turbine groupings to determine how wakes generated by upstream turbines affect the performance of the small turbine group as a whole. Specifically, various wind turbine arrangements were simulated to better understand how turbine location influences small group wake interactions. The minimization of power losses due to wake interactions certainly plays a significant role in the optimization of wind farms. Since wind turbines extract kinetic energy from the wind, the air passing through a wind turbine decreases in velocity, and turbines downstream of the initial turbine experience flows of lower energy, resulting in reduced power output. Our study proposes two arrangements of turbines that could generate more power by exploiting the momentum of the wind to increase velocity at downstream turbines, while maintaining low wake interactions at the same time. Furthermore, simulations using Computational Fluid Dynamics are used to obtain results much more quickly than methods requiring wind tunnel models or a large scale experimental test.

17 WIND ENERGY↗

Interface Control Document for the EMPACT Module that Estimates Electric Power Transmission System Response to EMP-Caused Damage

The EPREP code is designed to evaluate the effects of an Electro-Magnetic Pulse (EMP) on the electric power transmission system. The EPREP code embodies an umbrella framework that allows a user to set up analysis conditions and to examine analysis results. The code links to three major physics/engineering modules. The first module describes the EM wave in space and time. The second module evaluates the damage caused by the wave on specific electric power (EP) transmission system components. The third module evaluates the consequence of the damaged network on its (reduced) ability to provide electric power to meet demand. This third module is the focus of the present paper. The EMPACT code serves as the third module. The EMPACT name denotes EMP effects on Alternating Current Transmission systems. The EMPACT algorithms compute electric power transmission network flow solutions under severely damaged network conditions. Initial solutions are often characterized by unacceptible network conditions including line overloads and bad voltages. The EMPACT code contains algorithms to adjust optimally network parameters to eliminate network problems while minimizing outages. System adjustments include automatically adjusting control equipment (generator V control, variable transformers, and variable shunts), as well as non-automatic control of generator power settings and minimal load shedding. The goal is to evaluate the minimal loss of customer load under equilibrium (steady-state) conditions during peak demand.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TRACE Analysis of Loss of Flow for the APR1400

The APR1400 is a pressurized water reactor (PWR). The APR1400 nuclear steam supply system consists of a reactor pressure vessel (RPV), which contains the reactor core, and two primary reactor coolant system loops connected in parallel to the RPV. Each coolant loop consists of a hot leg (HL), a u-tube steam generator (SG), two reactor coolant pumps (RCPs) and two cold legs (CLs). A pressurizer is connected to the hot leg on one of the coolant loops. During normal operation, the RCPs circulate high pressure water through the reactor core to remove the heat. The heated water exits the RPV and passes through the hot legs into the steam generator tubes. Heat is transferred through the walls of the steam generator tubes into a lower pressure secondary coolant system. Cooled primary system water from the steam generators is returned through the RCPs and cold legs to the RPV. The RCPs operate at constant speed; the primary coolant system is designed to provide a prescribed rate of coolant flow through the reactor core. The APR1400 SG secondary coolant system pressure is controlled through modulation of valves in the steam lines to maintain a prescribed turbine inlet pressure. The SG secondary coolant inventory is controlled by using a feedwater control system to maintain a prescribed liquid level in the steam generator downcomer. This water inventory level is sufficient to cover the outer surfaces of the steam generator tubes while preventing overfill that would cause liquid to pass from the steam generators through the steam lines into the turbine system. In the current work, the Nuclear Regulatory Commission's reactor systems analysis code, TRACE?2 was used to perform an analysis of a loss of flow anticipated operational occurrence (AOO). The loss of flow is initiated by a loss of off-site power (LOOP), resulting in a trip of the RCPs. The regulatory purpose of the current work is to confirm safety analyses documented in the APR1400 Design Control Document (DCD)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Non-linear flow modes of identified particles in Pb-Pb collisions at $ \sqrt{s_{\mathrm{NN}}} $ = 5.02 TeV

The pT-differential non-linear flow modes, v 4,22 , v 5,32 , v 6,33 and v 6,222 for π ± , K ± , K$^0_S$ , $p + \bar{p}, Λ + \bar{Λ}$ and &straightphi;-meson have been measured for the first time at $\sqrt{s_{NN}}$ = 5.02 TeV in Pb-Pb collisions with the ALICE detector at the Large Hadron Collider. The results were obtained with a multi-particle technique, correlating the identified hadrons with reference charged particles from a different pseudorapidity region. These non-linear observables probe the contribution from the second and third order initial spatial anisotropy coefficients to higher flow harmonics. All the characteristic features observed in previous p T -differential anisotropic flow measurements for various particle species are also present in the non-linear flow modes, i.e. increase of magnitude with increasing centrality percentile, mass ordering at low p T and particle type grouping in the intermediate p T range. Hydrodynamical calculations (iEBE-VISHNU) that use different initial conditions and values of shear and bulk viscosity to entropy density ratios are confronted with the data at low transverse momenta. These calculations exhibit a better agreement with the anisotropic flow coefficients than the non-linear flow modes. These observations indicate that non-linear flow modes can provide additional discriminatory power in the study of initial conditions as well as new stringent constraints to hydrodynamical calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids

Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Shape and flow fluctuations in ultracentral Pb + Pb collisions at the energies available at the CERN Large Hadron Collider

In ultracentral heavy-ion collisions, anisotropic hydrodynamic flow is generated by density fluctuations in the initial state rather than by geometric overlap effects. For a given centrality class, the initial fluctuation spectrum is sensitive to the method chosen for binning the events into centrality classes. We show that sorting events by total initial entropy or by total final multiplicity yields event classes with equivalent statistical fluctuation properties, in spite of viscous entropy production during the fireball evolution. With this initial entropy-based centrality definition we generate several classes of ultracentral Pb + Pb collisions at CERN Large Hadron Collider energies and evolve the events using viscous hydrodynamics with nonzero shear but vanishing bulk viscosity. Comparing the predicted anisotropic flow coefficients for charged hadrons with CMS data we find that both the Monte Carlo Glauber (MC-Glb) and Monte Carlo Kharzeev-Levin-Nardi (MC-KLN) models produce initial fluctuation spectra that are incompatible with the measured final anisotropic flow power spectrum, for any choice of the specific shear viscosity. In spite of this failure, we show that the hydrodynamic model can qualitatively explain, in terms of event-by-event fluctuations of the anisotropic flow coefficients and flow angles, the breaking of flow factorization for elliptic, triangular, and quadrangular flow measured by the CMS experiment. For elliptic flow, this factorization breaking is large in ultracentral collisions. Finally, we conclude that the bulk of the experimentally observed flow factorization breaking effects are qualitatively explained by hydrodynamic evolution of initial-state fluctuations, but that their quantitative description requires a better understanding of the initial fluctuation spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hydrodynamics of countercurrent flows in a structured packed column: effects of initial wetting and dynamic contact angle

The structured packed column has gained considerable attention as a prospective technology to mitigate carbon dioxide emissions from thermal power plants. The computational flow investigation of such systems is a multiscale problem, and local hydrodynamics plays a key role in overall column efficiency. Accordingly, multiphase flow studies in the representative elementary unit (REU) of a packed column can offer insights into the local flow behavior such as flow pattern, interfacial area, etc. The interfacial area plays a key role in the overall interphase mass transfer and thereby in separation efficiency. The predicted effective area matches well with corresponding ones in experiments for Mellapak 250.Y packings. The contact angle (i.e., solid substrate behavior) is one of the critical factors that dictates wettings, and thereby the interfacial area. The dynamic contact angle (DCA) was considered in order to explore the effects of contact angle hysteresis on the interfacial area. DCA has more pronounced impact on the interfacial area for a solvent possessing a higher value of surface tension and equilibrium contact angle. The interfacial area shows temporal undulation and does not achieve a pseudo steady state due to the capillary force. In contrary, the interfacial area gets a net value for a solvent having low surface tension value. Further, specification of the static contact angle at the solid substrate shows the least value of the interfacial area. We also extensively studied the effect of the initial sheet condition (dry vs wet) on the interfacial area. The initially wetted sheets show slightly higher value of the interfacial area as compared to the initially dry sheets at a fixed flow rate for a solvent having high surface tension value. Wetting hysteresis decreases with increasing liquid loads. On the other hand, wetting hysteresis does not occur for a solvent having value of low surface tension and equilibrium contact angle.

structured packings, dynamic contact angle, interf↗

A Nonlinear Algebraic Multigrid Framework for the Power Flow Equations

Multigrid is a highly scalable class of methods most often used for solving large linear systems. In this paper we develop a nonlinear algebraic multigrid framework for the power flow equations, a complex quadratic system of the form ${diag}({v})\overline{Y{v}}={s}$, where $Y$ is approximately a complex scalar rotation of a real graph Laplacian. This is a standard problem that needs to be solved repeatedly during power grid simulations. A key difference between our multigrid framework and typical multigrid approaches is the use of a novel multiplicative coarse-grid correction to enable a dynamic multigrid hierarchy. We also develop a new type of smoother that allows one to coarsen together the different types of nodes that appear in power grid simulations. In developing a specific multigrid method, one must make a number of choices that can significantly affect the method's performance, such as how to construct the restriction and interpolation operators, what smoother to use, and how aggressively to coarsen. In this paper, we make simple but reasonable choices that result in a scalable and robust power flow solver. Experiments demonstrate this scalability and show that it is significantly more robust to poor initial guesses than current state-of-the-art solvers.

97 MATHEMATICS AND COMPUTING↗

Acceleration of Power System Dynamic Simulations Using a Deep Equilibrium Layer and Neural ODE Surrogate

The dominant paradigm for power system dynamic simulation is to build system-level simulations by combining physics-based models of individual components. The sheer size of the system along with the rapid integration of inverter-based resources exacerbates the computational burden of running time domain simulations. Here, in this paper, we propose a data-driven surrogate model based on implicit machine learningspecifically deep equilibrium layers and neural ordinary differential equationsto learn a reduced order model of a portion of the full underlying system. The data-driven surrogate achieves similar accuracy and reduction in simulation time compared to a physics-based surrogate, without the constraint of requiring detailed knowledge of the underlying dynamic models. This work also establishes key requirements needed to integrate the surrogate into existing simulation workflows; the proposed surrogate is initialized to a steady state operating point that matches the power flow solution by design.

Neural ordinary differential equations↗

Uncertainty Quantification on SAM Simulations of EBR-II Loss-of-Flow Tests

The System Analysis Module (SAM) is a modern system analysis tool being developed at Argonne National Laboratory for advanced non-LWR safety analysis. It aims to provide fast-running, whole-plant transient analyses capability with improved-fidelity for SFR, LFR, and MSR/FHR. In prior work, SAM has performed well in modeling the EBR-II benchmark based on the SHRT-17 and SHRT-45R protected and unprotected loss-of-flow experiments. However, underlying uncertainties in the modeling parameters need to be quantified to gain confidence in any best-estimate simulations. In this work, a Python coupling framework between Dakota and SAM has been developed to investigate these uncertainties, alongside code enhancements in SAM for user-flexibility in perturbing physical closure models and fluid equations of state. 25 significant input parameters covering boundary conditions, geometry, physical closure models, and equations of state were identified with their uncertainties defined from literature. Two SAM transient models for SHRT-17 and SHRT-45R were perturbed on these input parameters using Latin Hypercube Sampling and the uncertainties in predicted maximum fuel, cladding, and coolant temperatures were quantified as the output responses. Spearman rank correlation of input parameters to the predicted temperatures indicated that the most sensitive parameters include the initial core power, pipe wall drag, fuel & coolant conductivity, and peak channel flow area. Sensitivity of input parameters was found to differ between the two transients and core channel modeling strategies. The overall perturbations did not result in large uncertainties in the predicted temperatures, despite the efforts made to obtain accurate yet conservative input uncertainties.

Mui, Travis↗