Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system regulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Inter-Area Oscillation Damping with Type-5 Wind Power Plant

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and power system stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It may mitigate the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Design Considerations of DC/DC Regulator for High-Power Dynamic Wireless Charging Systems

Due to fast fluctuating input voltage, dynamic wireless charging requires a post-regulator stage for battery charging control and management. This regulator stage has a high requirement on efficiency, size as well as control performance to ensure tight regulation and fast trainset. This paper addresses the control challenges by modeling the system and designing the compensator with input voltage feedforward control. In addition, high resolution PWM is implemented to improve transient performance and current balancing among the phases. Experimental results prove the effectiveness of the proposed schemes and validates 180 kW closed-loop 4-phase operation at 99% efficiency.

Xue, Lincoln↗

Modular Power Electronics Approach for High Power Dynamic Wireless Charging System

Dynamic wireless power transfer (DWPT) can provide energy to EVs in motion and extend the drive range. Upscaling the charging power to 200 kW (High Power DWPT) reduces the percentage of electrified roadway required, and the solution becomes cost-effective. To smooth the power at the battery and grid, a secondary regulation stage must be added. The DWPT system therefore relies on power electronics to interface with the coils and regulate the power flow. Designing this high power system using wide bandgap devices makes ensuring high efficiency, small size, and reliable operation very challenging, and significant engineering effort is required to build such complicated systems for large-scale installation and deployment. Here, this paper describes a modular design approach for the power electronics to achieve the 200 kW wireless power transfer. As described, the SiC power electronics building block is designed, simulated, and characterized. The approach is validated in the DWPT system to build the inverter, the rectifier, and the DC/DC converter, which demonstrated high performance and reliable operation with 188 kW power.

42 ENGINEERING↗

Offering of Variable Resources in Regulation Markets with Performance Targets: An Analysis

To date, wind and solar power plants have mainly provided energy. Going forward, with the application of appropriate controls, they can offer additional grid services, such as regulating reserves. Additional grid services can present an opportunity for additional value streams to wind and solar power plants. However, the additional value might not be realized when operator-determined performance targets and settlement adjustments for the delivery of regulation capacity are disregarded. Additionally, this article studies the participation of variable resources in centralized regulation markets. We derive analytical results for regulation offers in terms of quantity and price considering that a variable resource does not want to risk being disqualified as a regulation provider, incurring losses, or foregoing more profitable opportunities. Our analysis suggests that U.S. operator-determined performance targets impose an upper bound on the quantity of a variable resource’s regulation offer; and settlement adjustments for the delivery of regulation affect the price at which variable resources offer and the calculations of opportunity costs in case of imperfect regulation delivery.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Overview of Behind-the-Meter Solar-Plus-Storage Regulatory Design: Approaches and Case Studies to Inform International Applications

Behind-the-meter energy storage systems paired with distributed photovoltaic (DPV) - with the capability to act as both generation and load - represent a unique and disruptive power sector technology capable of providing a range of important services to customers, utilities, and the broader power system. How should regulators, utilities, and policymakers manage the range of challenges and opportunities that increased behind-the-meter energy storage deployment will bring to the power system, in particular when these systems are paired with DPV? This report is intended to offer key regulatory considerations for facilitating DPV-plus-storage programs for retail customers; relevant cases from U.S. states are provided as examples of how novel regulatory issues related to behind-the-meter energy storage systems paired with DPV are being addressed in practice. At a high level, designing a regulatory framework that aligns DPV-plus-storage deployment with larger policy objectives requires thoughtful deliberation across a range of technical and economic issues. While this report attempts to segment many of these issues into distinct topics to enhance reader understanding, in reality, DPV-plus-storage regulatory issues are all closely integrated, and design decisions on a single aspect often have broader implications. With that in mind, this report outlines a series of steps that can be employed by regulators to approach DPV-plus-storage regulatory design.

14 SOLAR ENERGY↗

Self-regulating power management for a neural network system

A neural network runs a known input data set using an error free power setting and using an error prone power setting. The differences in the outputs of the neural network using the two different power settings determine a high level error rate associated with the output of the neural network using the error prone power setting. If the high level error rate is excessive, the error prone power setting is adjusted to reduce errors by changing voltage and/or clock frequency utilized by the neural network system. If the high level error rate is within bounds, the error prone power setting can remain allowing the neural network to operate with an acceptable error tolerance and improved efficiency. The error tolerance can be specified by the neural network application.

Kegel, Andrew G.↗

Self-regulating power management for a neural network system

A neural network runs a known input data set using an error free power setting and using an error prone power setting. The differences in the outputs of the neural network using the two different power settings determine a high level error rate associated with the output of the neural network using the error prone power setting. If the high level error rate is excessive, the error prone power setting is adjusted to reduce errors by changing voltage and/or clock frequency utilized by the neural network system. If the high level error rate is within bounds, the error prone power setting can remain allowing the neural network to operate with an acceptable error tolerance and improved efficiency. The error tolerance can be specified by the neural network application.

Kegel, Andrew G.↗

Limiter-aware adaptive excitation control for hydropower generators with legacy voltage regulation systems

Hydropower units often rely on legacy excitation systems with fixed automatic voltage regulator (AVR) settings, but parameter drift, changing operating conditions, and evolving grid-service demands can degrade terminal-voltage regulation over time. This problem should be addressed because poor voltage regulation affects reactive-power support, system stability, and reliable plant operation, and replacing installed AVR and limiter logic is costly and disruptive in practice. To address this issue, this paper proposes a retrofit-friendly enhancement for hydropower generator excitation systems that combines adaptive tuning of the AVR middle lead–lag branch with a small proportional-integral correction for removing steady bias and slow drift. The adaptive laws are normalized, projection-bounded, and equipped with leakage, while adaptation is enabled only in the middle branch. Thus, the intent of the underexcitation and overexcitation limiters, as well as legacy current and rate limits, remains unchanged. Stability is analyzed under incremental performance assumptions, yielding boundedness and asymptotic tracking in the absence of saturation. The method is evaluated using real operational data from a utility-scale hydropower unit at Rocky Reach Dam, Unit C-8. Compared with the fixed AVR baseline, the proposed method reduces terminal-voltage mean squared error by about 70%, removes long periods of steady-state bias, and improves transient tracking while coexisting with limiter actions. These results show that substantial voltage-control improvement can be achieved on existing hydropower units with minimal integration effort and without replacing the installed AVR structure.

ESST5B model↗

Optimization-Based Dynamic Voltage Support of Microgrids Using Energy Storage Systems

A microgrid network is characterized by a high R/X ratio, making the voltage more sensitive to active power changes compared to bulk power systems, where the voltage is regulated primarily by reactive power. Due to its sensitivity, voltage control approaches for microgrids should also consider the active power input coupling, making it very different from conventional power systems. Additionally, as the energy costs associated with active and reactive powers are different and the operational conditions of microgrids connected to active distribution systems vary over time, the ideal controller to provide voltage support must be flexible enough to handle these technical and operational constraints. This paper proposes a model predictive control approach to provide dynamic voltage support using energy storage systems. This approach uses a simplified predictive model of the system to solve the model predictive control problem. By proper selection of model predictive control weighting parameters, the quality of service provided can be adjusted to achieve the desired performance. A simulation study in MATLAB/Simulink validates the proposed approach for the Cordova, Alaska microgrid. Results show that the performance of the voltage support can be adjusted depending on the choice of weight and constraints of the controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Centers Gap Analysis [Slides]

Data centers and other large loads are a significant driver of unprecedented, near-term demand growth in the United States. Power system planners, utilities, regulators, and other stakeholders are grappling with how to integrate data centers on the system without comprising reliability, resiliency, and energy affordability. NLR is pursuing work to develop a siting and decision-making tool that would draw on power systems modeling expertise to achieve granular representation of trade-offs involved in data center sitting and development. This slide deck supports the same workstream by reviewing the literature to identify mitigation options to facilitate near-term integration of large loads and by presenting options for pursuing data development and/or modeling projects to improve representation of siting options.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Health and Climate Benefits of Economic Dispatch in China’s Power System

China’s power system is highly regulated and uses an “equal-share” dispatch approach. However, market mechanisms are being introduced to reduce generation costs and improve system reliability. Here, we quantify the climate and human health impacts brought about by this transition, modeling China’s power system operations under economic dispatch. We find that significant reductions in mortality related to air pollution (11%) and CO 2 emissions (3%) from the power sector can be attained by economic dispatch, relative to the equal-share approach, through more efficient coal-powered generation. Additional health and climate benefits can be achieved by incorporating emission externalities in electricity generation costs. However, the benefits of the transition to economic dispatch will be unevenly distributed across China and may lead to increased health damage in some regions. Our results show the potential of dispatch decision-making in electricity generation to mitigate the negative impacts of power plant emissions with existing facilities in China.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ASEAN Technical Exchange Workshop for System Operators, Regulators, and Policymakers

This presentation provides an in-depth exploration of power system planning, cross-border electricity trading, and battery energy storage systems (BESS), offering actionable insights for system operators, regulators, and policymakers. The first section delves into power system planning and analysis, focusing on capacity expansion models and resource adequacy studies, including their role in optimizing system efficiency, managing emissions, and addressing system reliability risks. Key considerations, such as integration of transmission into generation planning and the forecasting versus optimization of customer distributed energy resources (DER) technologies, are explored. The session highlights critical trade-offs in spatial granularity and model runtimes, as well as the feasibility of aligning distribution investments with capacity expansion efforts. The second section examines cross-border electricity trading, with an emphasis on resource adequacy concepts such as reliability targets, loss of load expectation (LOLE), and planning reserve margins (PRM). Case studies on reserve market design and coordination across US regions provide insights into improving reserve deliverability and managing interregional power balance and congestion. This section also addresses market-to-market congestion management, including advanced strategies for high-voltage direct current (HVDC) optimization and ancillary service delivery. Finally, the presentation covers the rapid evolution of Battery Energy Storage Systems (BESS), highlighting their operational growth, regulatory frameworks, and use cases in grid flexibility, energy storage, and reliability. The discussion focuses on the benefits of BESS for system stability, resilience, and integration of renewable energy, offering insights into its role as a vital component in the transition toward a more sustainable and flexible grid. Key performance parameters, such as throughput, round-trip efficiency, and state of charge, are also examined.

25 ENERGY STORAGE↗

Physics-Informed Graph Neural Networks for Collaborative Dynamic Reconfiguration and Voltage Regulation in Unbalanced Distribution Systems

Network reconfiguration has long been employed as a strategic approach to minimize power distribution system losses and effectively regulate voltage levels. Tap-changing voltage regulators are also critical for controlling bus voltages, especially in accommodating the increasing integration of distributed energy resources (DERs) with intermittent outputs. This paper introduces novel methodologies to address the challenges of dynamic reconfiguration and optimal tap setting in unbalanced three-phase distribution systems. We propose an approximated mixed-integer quadratically constrained program (MIQCP) to model dynamic reconfiguration, along with a pioneering formulation for voltage regulator (VR) tap-setting based on Special Ordered Set type 1 (SOS1). To mitigate computational complexity, we propose a physics-informed spatial-temporal graph convolutional network (STGCN) with an integrated link classifier. The proposed approach enables efficient solution generation by fixing specific variables in the MIQCP instance and solving the simplified sub-MIP using an MIP solver. Numerical studies demonstrate the superior prediction accuracy of our STGCN model compared to baseline neural network models, resulting in reduced DER curtailment and voltage deviation with shorter computation time.

dynamic reconfiguration↗

Cyber-Physical Dynamic System (CPDS) Modeling for Frequency Regulation and AGC Services of Distributed Energy Resources

The substantial integration of renewable energy brings significant challenges to balance the system in real time because of the variability and intermittency of renewable power. For the reliable system operation, the frequency regulation service is used to stabilize the system frequency through automatically balancing the system generation and load. On one hand, with the substantially increasing deployment of renewable energy in electricity system, the requirement of frequency regulation (FR) services increases significantly. On the other hand, the current main resource of FR services, the controllable conventional generation, is continuously decreasing in the system generation mix. This means that in the future high renewable penetration power system, additional and alternative reliable FR services providers such as distributed energy storage (DES) resources should be explored. Although the capability of utility-scale energy storage to provide FR services has been demonstrated, the integrated control and dynamic modeling of distributed energy resource (DER) providing frequency regulation grid services has been rarely explored. There are several challenges to adopt DERs to provide reliable grid services as illustrated in FERC 755. First, the distributed installation of DES requires a comprehensive cyber-physical dynamic system (CPDS) modeling to fully consider the impacts of the communication latency variability on its real time FR provision capability. Unlike the conventional generators, there are two-layer communication between DERs and system operators which increase the communication delay. Second, unlike the conventional generators whose dynamic models have been comprehensively studied, the difference among individual DER components' power-dynamic characteristic brings challenges in the accurate dynamic AGC modeling of its power-frequency relationship. Third, the temporal dependent state of charge uncertainty of DERs challenges DERs' power and frequency regulation capacities scheduling in the look-ahead generation scheduling. Therefore, the aggregator should optimize the frequency regulation provision from individual DER in real time. To overcome these challenges, this project proposes a cyber-physical dynamic system (CPDS) model to handle the uncertainty of DERs two-layer communication latency and power dynamics. The variability of DERs' communication delay and dynamic constraints will be comprehensively modeled. The DERs' AGC model with communication delay is designed to validate DESs' frequency regulation services. Like current performance-based frequency regulation evaluation, the delivery of DERs' frequency regulation will be assessed through post-analysis of the actual AGC response with respect to the AGC control signal from system operators. Consequently, the reliability improvement with DERs providing reliable frequency regulation services can be evaluated from a comprehensive perspective considering all the dynamics of communication and power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guest Editorial Special Issue on Emerging Topics of Power Electronics Interfaced Battery Energy Storage System

No doubt, battery energy storage systems have been the enabling solution to balance generation and consumption of power systems with high-penetration renewable energy resources, long-range electric vehicles, and various smart devices. Upon the battery has been manufactured, the rest of implementation issues become how to interface battery and related systems, how to regulate the charging/discharging power, and how to keep battery energy storage systems (BESSs) safe, reliable, and long-term service. In this editorial, we discuss how power electronic converters and associated control and optimization, which can maximize the value of BESSs, are devoted to provide cost-effective, efficient, and even revolutionary technologies.

25 ENERGY STORAGE↗

Opportunities for Renewable Energy, Storage, Vehicle Electrification, and Demand Response in Rajasthan's Power Sector

To support the government of Rajasthan and inform state policy makers, regulators, planners, and system operators on power system trends, NREL undertook a long-term capacity expansion planning study. We used NREL's flagship capacity expansion planning tool for the power sector called the Regional Energy Deployment System India (ReEDS-India) to understand the generation and transmission needs of Rajasthan through 2050. NREL's modeling framework includes co-optimized decisions about generation, energy storage, transmission, and reserves investments needed to meet future demand while maintaining reliable electricity supply. Scenario analysis was conducted to assess a range of potential future scenarios, providing insight for planning agencies, utilities, and local stakeholders about key trends and sources of uncertainty.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗