Search NASA⌕ Search

SEARCH · Search NASA

Results for “precision medicine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

28 records · Page 2

Biological Research and Space Health Enabled by Machine Learning to Support Deep Space Missions

A key science goal of the NASA “Moon to Mars” campaign is to understand how biology responds to the Lunar, Martian, and deep space environments in order to advance fundamental knowledge, reduce risk, and support safe, productive human space missions. Through the powerful emerging approaches of artificial intelligence (AI) and machine learning (ML), a paradigm shift has begun in biomedical science and engineered astronaut health systems, to enable Earth independence and autonomy of mission operations. Here we present an overview of AI/ML architecture to support deep space mission goals, developed with leaders in the field. First, we focus on the fundamental biological research that supports our understanding of physiological responses to spaceflight, and we describe current efforts to support AI/ML research including data standardization and data engineering through maximally open and FAIR (findable, accessible, interoperable, reusable) databases and the generation of AI-ready datasets for reuse and analysis. We also discuss remote data management frameworks for research data as well as environmental and health data that are generated during deep space missions. We highlight several research projects that leverage data standardization and management for fundamental biological discovery to uncover the complex effects of space travel on living systems. Next, we provide an overview of cutting-edge AI/ML approaches that can be integrated to support remote monitoring and analysis during deep space missions, including generative models and large language models to learn the underlying biomedical patterns and predict outcomes or answer questions during off world medical scenarios. We also describe current AI/ML methods to support this research and monitoring through automated cloud-based labs which enable limited human intervention and closed-loop experimentation in remote settings. These labs could support mission autonomy by analyzing environmental data streams, and would be facilitated through in situ analytics capabilities to avoid sending large raw data files through low bandwidth communications. Finally, in the context of deep space missions with limited communications or access to medical advice from Earth, we describe a solution for integrated, real-time mission biomonitoring across hierarchical levels from continuous environmental monitoring, to wearables and point-of-care devices, to molecular and physiological monitoring. We introduce a precision space health system that will ensure that the future of space health is predictive, preventative, participatory and personalized.

artificial intelligence↗

Medicine Delivery Device with Integrated Sterilization and Detection

Sterile delivery devices can be created by integrating a medicine delivery instrument with surfaces that are coated with germicidal and anti-fouling material. This requires that a large-surface-area template be developed within a constrained volume to ensure good contact between the delivered medicine and the germicidal material. Both of these can be integrated using JPL-developed silicon nanotip or cryo-etch black silicon technologies with atomic layer deposition (ALD) coating of specific germicidal layers. The application of semiconductor processing techniques and technologies to the problems of fluid manipulation and delivery has enabled the integration of chemical, electrical, and mechanical manipulation of samples all within a single microfluidic device. This approach has been successfully applied at JPL to the automated processing, detection, and analysis of minute quantities (parts per trillion level) of biomaterials to develop instruments for in situ exploration or extraterrestrial bodies. The same nanofabrication techniques that are used to produce a microfluidics device are also capable of synthesizing extremely high-surface-area templates in precise locations, and coating those surfaces with conformal films to manipulate their surface properties. This methodology has been successfully applied at JPL to produce patterned and coated silicon nanotips (also known as black silicon) to manipulate the hydrophilicity of surfaces to direct the spreading of fluids in microdevices. JPL's ALD technique is an ideal method to produce the highly conformal coatings required for this type of application. Certain materials, such as TiO2, have germicidal and anti-fouling properties when they are illuminated with UV light. The proposed delivery device contacts medicine with this high-surface-area black silicon surface coated with a thin-film germicidal deposited conformally with ALD. The coating can also be illuminated with ultraviolet light for the purpose of sterilization or identification of the medicine itself. This constrained volume that is located immediately prior to delivery into a patient, ensures that the medicine delivery device is inherently sterile. An additional benefit to integrating a high-surface-area template within the fluid channel of a medicine delivery device is that one can envision a number of different functional coatings that could facilitate the capture and analysis of either microbial contaminants or the medicine itself. For example, one could attach antibodies or some other binding agent with a specific affinity to the silicon nanotip template. Once a target molecule or microbe is bound to the high-surface- area template, one could use an optical analytical technique such as fluorescence or adsorption to determine the identity and potentially the concentration of the species of interest. By illuminating the bound species from the back, it may also be possible to probe only the molecules with an evanescent wave, making detection of the species from the front side of the device much simpler.

Shearn, Michael J.↗

Fabricating High-Resolution X-Ray Collimators

A process and method for fabricating multi-grid, high-resolution rotating modulation collimators for arcsecond and sub-arcsecond x-ray and gamma-ray imaging involves photochemical machining and precision stack lamination. The special fixturing and etching techniques that have been developed are used for the fabrication of multiple high-resolution grids on a single array substrate. This technology has application in solar and astrophysics and in a number of medical imaging applications including mammography, computed tomography (CT), single photon emission computed tomography (SPECT), and gamma cameras used in nuclear medicine. This collimator improvement can also be used in non-destructive testing, hydrodynamic weapons testing, and microbeam radiation therapy.

Appleby, Michael↗

Mapping by VESGEN of Blood Vessels in the Retinas of ISS Crew Members and Bed Rest Subjects for Increased Understanding of VIIP

Research by NASA has established that significant risks for visual impairment in association with increased intracranial pressure (VIIP) are incurred by microgravity spaceflight, especially long-duration missions. Impairments include decreased near visual acuity, posterior globe flattening, choroidal folds, optic disc edema, and cotton wool spots. Much remains to be learned about the etiology of VIIP before effective countermeasures can be developed. Contributions of retinal vascular remodeling to the etiology of VIIP have not yet been investigated, primarily due to the current lack of ophthalmic tools for precisely measuring progressive pathophysiological remodeling of the retinal microvasculature. Although ophthalmic science and clinical practice are now highly sophisticated at detecting indirect, secondary signs of vascular remodeling such as cotton wool spots that arise during the progression of retinal vascular diseases, methods for quantifying direct, primary vascular changes are not yet established. To help develop insightful analysis of retinal vascular remodeling for aerospace medicine, we will map and quantify by our innovative VESsel GENeration Analysis (VESGEN) software the remodeling status of retinal blood vessels in crew members before and after ISS missions, and in healthy human subjects before and after head-down tilt bed rest. For this proof-of-concept study, we hypothesize that pathophysiological remodeling of retinal blood vessels occurs in coordination with microgravity-induced fluid shifts prior to development of visual impairments. VESGEN analysis in previous research supported by the US National Institutes of Health identified surprising new opportunities to regenerate retinal vessels during early-stage progression of the visually impairing, potentially blinding disease, diabetic retinopathy.

ISS Crew↗

Quantifying Caloric Expenditure During Zero-G Exercise

BACKGROUND: Exercise is a fundamental component of maintaining astronaut health on long-duration space missions, where the microgravity environment poses unique challenges to physiological homeostasis. Accurate quantification of energy expenditure during such exercises is crucial for optimizing nutritional and physical health strategies for spacefarers. OBJECTIVE: This study aims to develop a comprehensive model to estimate caloric expenditure during exercise in a microgravity environment, employing a combination of spirometry, heart rate data, and other relevant parameters. By assessing energy utilization under these conditions, we seek to facilitate enhanced health management protocols for astronauts in space. METHODS & OUTCOMES: A multivariate predictive model will be constructed, utilizing spirometry and heart rate data, coupled with additional physiological and environmental parameters. A systematic approach will be applied to analyze the relationship between these variables and energy expenditure during various exercises. The proposed model will subsequently undergo rigorous validation to ensure accuracy and reliability. This research is expected to yield a precise and reliable predictive model, contributing to improved strategies for exercise prescription and nutritional intake, addressing the unique challenges presented by microgravity environments. We anticipate that our findings will support the development of more effective health maintenance protocols for astronauts during extended space missions, mitigating the adverse effects of space travel on the human body. SIGNIFICANCE: The development of an accurate and adaptable model to quantify caloric expenditure during exercise in space represents a pivotal advancement in space medicine. The insights gained from this study have the potential to inform the design of enhanced health and wellness strategies, ensuring the well-being and operational effectiveness of astronauts in long-duration space missions.

Calorie↗

Identifying Neutron Irradiation in Space to Mitigate Bio-Medical Effects

One of the primary challenges to interplanetary human travel is mitigation of radiation expo-sure. As fast transit with LENR driven or conventional nuclear electric (NEP) or thermal propulsion (NTP) may be imminent, time and level of radiation exposure composingALARA (As Low as Rea-sonably Achievable) must be ascertained rapidly and precisely. Since acute physiological effects are difficult to detect, and chronic effects on crew health are delayed and potentially trans-generational, improved detection technologies will be game-changing and an essential element of the crew health monitoring and environmental protection toolkit.Secondary Galactic Cosmic Ray (GCR) induced neutrons are an additional hazard.

space medicine↗

NASA Tech Briefs, September 2013

Topics include: ISS Ammonia Leak Detection Through X-Ray Fluorescence; A System for Measuring the Sway of the Vehicle Assembly Building; Fast, High-Precision Readout Circuit for Detector Arrays; Victim Simulator for Victim Detection Radar; Hydrometeor Size Distribution Measurements by Imaging the Attenuation of a Laser Spot; Quasi-Linear Circuit; High-Speed, High-Resolution Time-to-Digital Conversion; Li-Ion Battery and Supercapacitor Hybrid Design for Long Extravehicular Activities; Ultrasonic Low-Friction Containment Plate for Thermal and Ultrasonic Stir Weld Processes; High-Powered, Ultrasonically Assisted Thermal Stir Welding; Next-Generation MKIII Lightweight HUT/Hatch Assembly; Centrifugal Sieve for Gravity-Level-Independent Size; Segregation of Granular Materials; Ion Exchange Technology Development in Support of the Urine Processor Assembly; Nickel-Graphite Composite Compliant Interface and/or Hot Shoe Material; UltraSail CubeSat Solar Sail Flight Experiment; Mechanism for Deploying a Long, Thin-Film Antenna From a Rover; Counterflow Regolith Heat Exchanger; Acquisition and Retaining Granular Samples via a Rotating Coring Bit; Very-Low-Cost, Rugged Vacuum System; Medicine Delivery Device With Integrated Sterilization and Detection; FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D; Multimode Directional Coupler for Utilization of Harmonic Frequencies from TWTAs; Dual-Polarization, Multi-Frequency Antenna Array for use with Hurricane Imaging Radiometer; Complementary Barrier Infrared Detector (CBIRD) Contact Methods; Autonomous Control of Space Nuclear Reactors; High-Power, High-Speed Electro-Optic Pockels Cell Modulator; Covariance Analysis Tool (G-CAT) for Computing Ascent, Descent, and Landing Errors; Enigma Version 12; Micrometeoroid and Orbital Debris (MMOD) Shield Ballistic Limit Analysis Program; Spitzer Telemetry Processing System; Planetary Protection Bioburden Analysis Program; Wing Leading Edge RCC Rapid Response Damage Prediction Tool (IMPACT2); ISSM: Ice Sheet System Model; Automated Loads Analysis System (ATLAS); Integrated Main Propulsion System Performance Reconstruction Process/Models. Phoenix Telemetry Processor; Contact Graph Routing Enhancements Developed in ION for DTN; GFEChutes Lo-Fi; Advanced Strategic and Tactical Relay Request Management for the Mars Relay Operations Service; Software for Generating Troposphere Corrections for InSAR Using GPS and Weather Model Data; Ionospheric Specifications for SAR Interferometry (ISSI); Implementation of a Wavefront-Sensing Algorithm; Sally Ride EarthKAM - Automated Image Geo-Referencing Using Google Earth Web Plug-In; Trade Space Specification Tool (TSST) for Rapid Mission Architecture (Version 1.2); Acoustic Emission Analysis Applet (AEAA) Software; Memory-Efficient Onboard Rock Segmentation; Advanced Multimission Operations System (ATMO); Robot Sequencing and Visualization Program (RSVP); Automating Hyperspectral Data for Rapid Response in Volcanic Emergencies; Raster-Based Approach to Solar Pressure Modeling; Space Images for NASA JPL Android Version; Kinect Engineering with Learning (KEWL); Spacecraft 3D Augmented Reality Mobile App; MPST Software: grl_pef_check; Real-Time Multimission Event Notification System for Mars Relay; SIM_EXPLORE: Software for Directed Exploration of Complex Systems; Mobile Timekeeping Application Built on Reverse-Engineered JPL Infrastructure; Advanced Query and Data Mining Capabilities for MaROS; Jettison Engineering Trajectory Tool; MPST Software: grl_suppdoc; PredGuid+A: Orion Entry Guidance Modified for Aerocapture; Planning Coverage Campaigns for Mission Design and Analysis: CLASP for DESDynl; and Space Place Prime.

Source record↗

Micromachined TWTs for THz Radiation Sources

The Terahertz (THz) region of the electromagnetic spectrum (about 300 - 3000 GHz in frequency or about 0.1 - 1 mm free space wavelength) has enormous potential for high-data-rate communications, spectroscopy, astronomy, space research, medicine, biology, surveillance, remote sensing, industrial process control, etc. It has been characterized as the most scientifically rich, yet under-utilized, region of the electromagnetic spectrum. The most critical roadblock to full exploitation of the THz band is lack of coherent radiation sources that are powerful (0.001 - 1.0 W continuous wave), efficient (> 1%), frequency agile (instantaneously tunable over 1% bandwidths or more), reliable, and comparatively inexpensive. To develop vacuum electron device (VED) radiation sources satisfying these requirements, fabrication and packaging approaches must be heavily considered to minimize costs, in addition to the basic interaction physics and circuit design. To minimize size of the prime power supply, beam voltage must be minimized, preferably 10 kV. Solid state sources satisfy the low voltage requirement, but are many orders of magnitude below power, efficiency, and bandwidth requirements. On the other hand, typical fast-wave VED sources in this regime (e.g., gyrotrons, FELs) tend to be large, expensive, high voltage and very high power devices unsuitable for most of the applications cited above. VEDs based on grating or inter-digital (ID) circuits have been researched and developed. However, achieving forward-wave amplifier operation with instantaneous fractional bandwidths > 1% is problematic for these devices with low-energy (< 15 kV) electron beams. Moreover, the interaction impedance is quite low unless the beam-circuit spacing is kept particularly narrow, often leading to significant beam interception. One solution to satisfy the THz source requirements mentioned above is to develop micromachined VEDs, or "micro-VEDs". Among other benefits, micro-machining technologies provide superior high frequency wall conductivity as a result of superior surface smoothness compared with conventional mechanical or electric discharge machining approaches. Micro-VED technologies are already being applied to the development of millimeter-wave klystrons at Stanford Linear Accelerator Center and submillimeter-wave klystrons at the University of Leeds. We are investigating the use of micro-machining technologies to develop THz regime TWTs, with emphasis on folded-waveguide TWTs. The folded-waveguide TWT (FW-TWT) has several features that make it attractive for THz-regime micro-VED applications. It is a relatively simple circuit to design and fabricate, it is amenable to precision pattern replication by micro-machining, and it is has been demonstrated capable of forward-wave amplification with appreciable bandwidth. We are conducting experimental and computational studies of micro-VED FW-TWTs to examine their feasibility for applications at frequencies from 200 - 1000 GHz.

Booske, John H.↗

Self-motion perception: assessment by computer-generated animations

The goal of this research is more precise description of adaptation to sensory rearrangements, including microgravity, by development of improved procedures for assessing spatial orientation perception. Thirty-six subjects reported perceived self-motion following exposure to complex inertial-visual motion. Twelve subjects were assigned to each of 3 perceptual reporting procedures: (a) animation movie selection, (b) written report selection and (c) verbal report generation. The question addressed was: do reports produced by these procedures differ with respect to complexity and reliability? Following repeated (within-day and across-day) exposures to 4 different "motion profiles," subjects either (a) selected movies presented on a laptop computer, or (b) selected written descriptions from a booklet, or (c) generated self-motion verbal descriptions that corresponded most closely with their motion experience. One "complexity" and 2 reliability "scores" were calculated. Contrary to expectations, reliability and complexity scores were essentially equivalent for the animation movie selection and written report selection procedures. Verbal report generation subjects exhibited less complexity than did subjects in the other conditions and their reports were often ambiguous. The results suggest that, when selecting from carefully written descriptions and following appropriate training, people may be better able to describe their self-motion experience with words than is usually believed.

Non-NASA Center↗

Computer based imaging and analysis of root gravitropism

Two key issues in studies of the nature of the gravitropic response in roots have been the determination of the precise pattern of differential elongation responsible for downward bending and the identification of the cells that show the initial motor response. The main approach for examining patterns of differential growth during root gravitropic curvature has been to apply markers to the root surface and photograph the root at regular intervals during gravitropic curvature. Although these studies have provided valuable information on the characteristics of the gravitropic motor response in roots, their labor intensive nature limits sample size and discourages both high frequency of sampling and depth of analysis of surface expansion data. In this brief review we describe the development of computer-based video analysis systems for automated measurement of root growth and shape change and discuss some key features of the root gravitropic response that have been revealed using this methodology. We summarize the capabilities of several new pieces of software designed to measure growth and shape changes in graviresponding roots and describe recent progress in developing analysis systems for studying the small, but experimentally popular, primary roots of Arabidopsis. A key finding revealed by such studies is that the initial gravitropic response of roots of maize and Arabidopsis occurs in the distal elongation zone (DEZ) near the root apical meristem, not in the main elongation zone. Another finding is that the initiation of rapid elongation in the DEZ following gravistimulation appears to be related to rapid membrane potential changes in this region of the root. These observations have provided the incentive for ongoing studies examining possible links between potential growth modifying factors (auxin, calcium, protons) and gravistimulated changes in membrane potential and growth patterns in the DEZ.

NASA Discipline Plant Biology↗