Search NASA⌕ Search

SEARCH · Search NASA

Results for “precision requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Precision in Assembled Discrete Lattice Space Structures for Next-Generation ISAM Applications

Robust autonomous robotic assembly of large-scale space structures has been a long-term and challenging goal to enable higher quality in-space communication and science instrumentation. For optical observatory support structures and antenna structures, the challenge is the strict dimensional precision requirements (generally RMS surface error) driven by the operational radiation wavelength. Early theoretical work in the area linked RMS surface error of a reflector support truss plate to the natural passive dynamic mode frequencies of the structure, as well as to the error distribution in dimensions of constituent structural elements. Prior robotic truss assembly demonstrations focused on designing ultra-high precision structural elements, joints, and robotic actuators. Recently, an alternative space structure assembly strategy based on a programmable matter approach (NASA ARMADAS) was demonstrated. This approach uses lattice building blocks (voxels) that are reversibly, mechanically joined into a bulk lattice structure by robots that locomote in and on the structure itself. Such a system can achieve high-level autonomy with low computation, robustly assemble utilizing inexpensive and imprecise robots, and efficiently build structures several orders of magnitude larger than the assembly robots. However, for instrumentation support structure applications, the resulting precision of these building block-based lattice structures is not well studied. Since they are demonstrated with many more assembly units than prior art trusses, it is unclear whether the same precision design approaches apply. In this work, we study in simulation the effects of voxel geometry, error in distribution, assembly resolution (module size), and assembly geometry on the error of both beam and plate lattice structures. While average RMS error of a plate increases with plate size, increasing plate thickness quickly collapses RMS error towards a limit that is on the order of the error of the constituent parts. We validate our models against previously published precision measurements of built systems. Results from this study will guide manufacturing precision requirements, as well as designs, for future robotically assembled structural applications and establish feasibility for different applications.

Christine E Gregg↗

Accelerator Neutrinos

Neutrino beams from particle accelerators are vital for probing fundamental physics, enabling experiments like DUNE and NOvA to study neutrino oscillations and CP violation. These experiments push proton beam power to multi-MW levels and require precise beam instrumentation to manage flux and enhance precision. This talk will explore advancements in neutrino beam technology, highlighting the challenges and future prospects of high-intensity, well-collimated beams for next-generation accelerator facilities. Neutrino beams from particle accelerators are vital for probing fundamental physics, enabling experiments like DUNE and NOvA to study neutrino oscillations and CP violation. These experiments push proton beam power to multi-MW levels and require precise beam instrumentation to manage flux and enhance precision. This talk will explore advancements in neutrino beam technology, highlighting the challenges and future prospects of high-intensity, well-collimated beams for next-generation accelerator facilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatial and Temporal Variability of Trace Gas Columns Derived from WRF/Chem Regional Model Output: Planning for Geostationary Observations of Atmospheric Composition

We quantify both the spatial and temporal variability of column integrated O3, NO2, CO, SO2, and HCHO over the Baltimore / Washington, DC area using output from the Weather Research and Forecasting model with on-line chemistry (WRF/Chem) for the entire month of July 2011, coinciding with the first deployment of the NASA Earth Venture program mission Deriving Information on Surface conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ). Using structure function analyses, we find that the model reproduces the spatial variability observed during the campaign reasonably well, especially for O3. The Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument will be the first NASA mission to make atmospheric composition observations from geostationary orbit and partially fulfills the goals of the Geostationary Coastal and Air Pollution Events (GEO-CAPE) mission. We relate the simulated variability to the precision requirements defined by the science traceability matrices of these space-borne missions. Results for O3 from 0- 2 km altitude indicate that the TEMPO instrument would be able to observe O3 air quality events over the Mid-Atlantic area, even on days when the violations of the air quality standard are not widespread. The results further indicated that horizontal gradients in CO from 0-2 km would be observable over moderate distances (≥ 20 km). The spatial and temporal results for tropospheric column NO2 indicate that TEMPO would be able to observe not only the large urban plumes at times of peak production, but also the weaker gradients between rush hours. This suggests that the proposed spatial and temporal resolutions for these satellites as well as their prospective precision requirements are sufficient to answer the science questions they are tasked to address.

TEMPO↗

A simulator study on information requirements for precision hovering

A fixed base simulator study of an advanced helicopter instrument display utilizing translational acceleration, velocity and position information is reported. The simulation involved piloting a heavy helicopter using the Integrated Trajectory Error Display (ITED) in a precision hover task. The test series explored two basic areas. The effect on hover accuracy of adding acceleration information was of primary concern. Also of interest was the operators' ability to use degraded information derived from less sophisticated sources. The addition of translational acceleration to a display containing velocity and position information did not appear to improve the hover performance significantly. However, displayed acceleration information seemed to increase the damping of the man machine system. Finally, the pilots could use translational information synthesized from attitude and angular acceleration as effectively as perfect acceleration.

Lemons, J. L.↗

Miniature X-Ray Bone Densitometer

The purpose of the Dual Energy X-ray Absorptiometry (DEXA) project is to design, build, and test an advanced X-ray absorptiometry scanner capable of being used to monitor the deleterious effects of weightlessness on the human musculoskeletal system during prolonged spaceflight. The instrument is based on the principles of dual energy x-ray absorptiometry and is designed not only to measure bone, muscle, and fat masses but also to generate structural information about these tissues so that the effects on mechanical integrity may be assessed using biomechanical principles. A skeletal strength assessment could be particularly important for an astronaut embarking on a remote planet where the consequences of a fragility fracture may be catastrophic. The scanner will employ multiple projection images about the long axis of the scanned subject to provide geometric properties in three dimensions, suitable for a three-dimensional structural analysis of the scanned region. The instrument will employ advanced fabrication techniques to minimize volume and mass (100 kg current target with a long-term goal of 60 kg) of the scanner as appropriate for the space environment, while maintaining the required mechanical stability for high precision measurement. The unit will have the precision required to detect changes in bone mass and geometry as small as 1% and changes in muscle mass as small as 5%. As the system evolves, advanced electronic fabrication technologies such as chip-on-board and multichip modules will be combined with commercial (off-the-shelf) parts to produce a reliable, integrated system which not only minimizes size and weight, but, because of its simplicity, is also cost effective to build and maintain. Additionally, the system is being designed to minimize power consumption. Methods of heat dissipation and mechanical stowage (for the unit when not in use) are being optimized for the space environment.

Charles, Harry K., Jr.↗

Drilling Precise Orifices and Slots

Reaction control thrustor injector requires precisely machined orifices and slots. Tooling setup consists of rotary table, numerical control system and torque sensitive drill press. Components used to drill oxidizer orifices. Electric discharge machine drills fuel-feed orifices. Device automates production of identical parts so several are completed in less time than previously.

Richards, C. W.↗

Dual-Image Color Normalization to Enable High-Performance Concentrating Solar Optical Metrology

Concentrating Solar Power (CSP) requires precision mirrors, and these in turn require metrology systems to measure their optical slope. In this project we studied a color-based approach to the correspondence problem, which is the association of points on an optical target with their corresponding points seen in a reflection. This is a core problem in deflectometry-based metrology, and a color solution would enable important new capabilities. We modeled color as a vector in the [R,G,B] space measured by a digital camera, and explored a dual-image approach to compensate for inevitable changes in illumination color. Through a series of experiments including color target design and dual-image setups both indoors and outdoors, we collected reference/measurement image pairs for a variety of configurations and light conditions. We then analyzed the resulting image pairs by selecting example [R,G,B] pixels in the reference image, and seeking matching [R,G,B] pixels in the measurement image. Modulating a tolerance threshold enabled us to assess both match reliability and match ambiguity, and for some configurations, orthorectification enabled us to assess match accuracy. Using direct-direct imaging, we demonstrated color correspondence achieving average match accuracy values of 0.004 h, where h is the height of the color pattern. We found that wide-area two-dimensional and linear one-dimensional color targets outperformed hybrid linear/lateral gradient targets in the cases studied. Introducing a mirror degraded performance under our current techniques, and we did not have time to evaluate whether matches could be reliably achieved despite varying light conditions. Nonetheless, our results thus far are promising.

14 SOLAR ENERGY↗

Critical requirements for the design of large space structures

The requirements for the design of a large space structure which will be deployed, erected, assembled or fabricated in space are delineated in terms of operational loads, stiffness requirements, structure-control interaction, deformations, precision requirements and member slenderness. Design examples for a truss antenna reflector, interorbit propulsion loads and free-flying solar reflectors are given. It is concluded that the demand for dimensional accuracy and stability form the primary requirements.

Hedgepeth, J. M.↗

Modeling Stellar Jitter and its Effects on the Stellar Spectrum for More Precise Radial Velocity Measurements

Detection of Earth-size exoplanets is a technological and data analysis challenge. Future progress in Earth-mass exoplanet detection is expected from the development of extreme precision radial velocity (EPRV) measurements. The required precision of these measurements necessitates developing a new physics-based data analysis methodology to discriminate planetary signals from host-star-related effects, taking stellar variability and instrumental uncertainties into account. In this work, we investigate and quantify stellar disturbances of the planet-hosting solar-type star HD121504 from 3D radiative modeling obtained with the StellarBox code. The model was used to determine the statistical properties of the turbulent plasma and to obtain synthetic spectroscopic observations for several Fe I lines at different locations on the stellar disk to mimic high-resolution spectroscopic observations. Presented are the initial results of our effort to characterize stellar jitter properties as well as future objectives.

SMD↗

Making Precise Antenna Reflectors For Millimeter Wavelengths

In improved method of fabrication of precise, lightweight antenna reflectors for millimeter wavelengths, required precise contours of reflecting surfaces obtained by computer numberically controlled machining of surface layers bonded to lightweight, rigid structures. Achievable precision greater than that of older, more-expensive fabrication method involving multiple steps of low- and high-temperature molding, in which some accuracy lost at each step.

Sharp, G. Richard↗

Precision maneuver determination for trajectory corrections

The interplanetary navigation of a spacecraft requires precise calculation of trajectory correction maneuver parameters. Velocity increments must be found which make the required corrections, minimize propellant consumption, and do not violate hardware design constraints or scientific objectives. This process is illustrated by its application to the Galileo Mission. The paper describes inflight analysis techniques, mathematical modeling, and computational algorithms used in the precision maneuver calculation scenario.

Hintz, G. R.↗

Laboratory molecular spectroscopy

The precision required in making spectroscopic measurements is discussed. Remarks are directed specifically to vibration-rotation spectra rather than continuum absorptions. The ultimate precision that is required for line positions is related to the width of the lines which may be no narrower than the Doppler width. The spectroscopic methods considered are those which are of the most general value to the astronomers; those which acquire and can handle large volumes of spectra in digital form, or in a form which is compatible with computer analysis, and in a form which is at least internally consistent. The use of dye laser, grating instruments, and the most versatile instrument for laboratory spectroscopy, the Fourier transform spectrometer is discussed.

Margolis, J.↗

Design and breadboard evaluation of the SPS reference phase control system concept

Efficient operation of a very large phased array such as the proposed solar power satellite, requires precision focusing and pointing of the power beam; i.e., the power beam must have a planar wavefront directed precisely at the center of the target antenna (rectenna). To maintain such a power beam requires real-time phase compensation at each subaperture in order to adjust for structural deformations and other transitory factors. In the current solar power satellite (SPS) baseline, the spaceborne antenna (Spacetenna) is an active retrodirective array. A pilot signal transmitted from the center of the rectenna is phase-conjugated at each subaperture (power module) of the spacetenna, thereby assuring that the radiated composite wave is focused on the target. This scheme requires a large amount of precision electronic circuitry on the spacetenna. Specifically, pilot receivers must be located at each power module and an adaptive distribution network is required in order to provide a properly phased reference signal at each conjugator.

Hopkins, P. M.↗

High frequency flow-structural interaction in dense subsonic fluids

Prediction of the detailed dynamic behavior in rocket propellant feed systems and engines and other such high-energy fluid systems requires precise analysis to assure structural performance. Designs sometimes require placement of bluff bodies in a flow passage. Additionally, there are flexibilities in ducts, liners, and piping systems. A design handbook and interactive data base have been developed for assessing flow/structural interactions to be used as a tool in design and development, to evaluate applicable geometries before problems develop, or to eliminate or minimize problems with existing hardware. This is a compilation of analytical/empirical data and techniques to evaluate detailed dynamic characteristics of both the fluid and structures. These techniques have direct applicability to rocket engine internal flow passages, hot gas drive systems, and vehicle propellant feed systems. Organization of the handbook is by basic geometries for estimating Strouhal numbers, added mass effects, mode shapes for various end constraints, critical onset flow conditions, and possible structural response amplitudes. Emphasis is on dense fluids and high structural loading potential for fatigue at low subsonic flow speeds where high-frequency excitations are possible. Avoidance and corrective measure illustrations are presented together with analytical curve fits for predictions compiled from a comprehensive data base.

Liu, Baw-Lin↗

Robotic Surgery

The Automated Endoscopic System for Optimal Positioning, or AESOP, was developed by Computer Motion, Inc. under a SBIR contract from the Jet Propulsion Lab. AESOP is a robotic endoscopic positioning system used to control the motion of a camera during endoscopic surgery. The camera, which is mounted at the end of a robotic arm, previously had to be held in place by the surgical staff. With AESOP the robotic arm can make more precise and consistent movements. AESOP is also voice controlled by the surgeon. It is hoped that this technology can be used in space repair missions which require precision beyond human dexterity. A new generation of the same technology entitled the ZEUS Robotic Surgical System can make endoscopic procedures even more successful. ZEUS allows the surgeon control various instruments in its robotic arms, allowing for the precision the procedure requires.

Source record↗

Attitude control requirements for future space systems

Landsat-D and the Large Space Telescope represent current state-of-the-art systems with precise requirements placed on attitude control. Future systems for planetary stations, high precision earth monitoring and large precision deployable and erectable platforms project still more severe constraints and requirements on attitude control, including the requirement for many enabling and highly enhanced technologies beyond current state of the art. Two trend projections are identified for the areas of (1) precision pointing systems for earth orbiters and planetary spacecraft and (2) onboard high-capacity fast controllers for distributed control systems.

Dahlgren, J. B.↗

Application of Millisecond Pulsar Timing to the Long-Term Stability of Clock Ensembles

We review the application of millisecond pulsars to define a precise long-term standard and positional reference system in a nearly inertial reference frame. We quantify the current timing precision of the best millisecond pulsars and define the required precise time and time interval (PTTI) accuracy and stability to enable time transfer via pulsars. Pulsars may prove useful as independent standards to examine decade-long timing stability and provide an independent natural system within which to calibrate any new, perhaps vastly improved atomic time scale. Since pulsar stability appears to be related to the lifetime of the pulsar, the new millisecond pulsar J173+0747 is projected to have a 100-day accuracy equivalent to a single HP5071 cesium standard. Over the last five years, dozens of new millisecond pulsars have been discovered. A few of the new millisecond pulsars may have even better timing properties.

Foster, Roger S.↗

Defining Navigation Requirements for Future Precision Lander Missions

Human mission concepts for both the Moon and Mars require landing precision capabilities beyond the current state of art. The Safe and Precise Landing Integrated Capabilities Evolution (SPLICE) project leverages previous work at NASA to develop multimission precision landing and hazard avoidance (PL&HA) technologies to meet the advanced landing requirements. SPLICE aims to develop guidance, navigation and control (GN&C) capabilities for both Moon and Mars lander missions. The approach the project is using to identify a standard suite begins with developing a PL&HA requirements matrix to inform technology investments. The approach to develop a multi-mission navigation requirements matrix includes identifying representative concepts of operations for both robotic and human missions. It also identifies navigation sensor options with estimated performance parameters. This paper summarizes the concepts of operations and sensors considered to develop the SPLICE PL&HA requirements matrix. A description of the analysis used to determine candidate optimal sensor suites and initial results are provided.

Dwyer Cianciolo, Alicia↗