Absolute low-pressure calibration system

McLeod gage is used as the primary reference standard in a system used for absolute calibration of vacuum gages in the very low pressure range. The system involves steady-state flow of a gas through a cascade of differentially pumped chambers or stages connected by precisely defined orifices.

Roehrig, J. R.↗

Development and Characterization of a Low-Pressure Calibration System for Hypersonic Wind Tunnels

Minimization of uncertainty is essential for accurate ESP measurements at very low free-stream static pressures found in hypersonic wind tunnels. Statistical characterization of environmental error sources requires a well defined and controlled calibration method. A calibration system has been constructed and environmental control software developed to control experimentation to eliminate human induced error sources. The initial stability study of the calibration system shows a high degree of measurement accuracy and precision in temperature and pressure control. Control manometer drift and reference pressure instabilities induce uncertainty into the repeatability of voltage responses measured from the PSI System 8400 between calibrations. Methods of improving repeatability are possible through software programming and further experimentation.

Green, Del L.↗

Alexandrite as a high-temperature pressure calibrant, and implications for the ruby-fluorescence scale

The wavelength shifts of the R1 and R2 fluorescence lines of alexandrite (BeAl2O4:Cr(+3)) have been experimentally calibrated against the ruby-fluorescence scale as a function of both hydrostatic and nonhydrostatic pressures between 0 and 50 GPa, and simultaneously as a function of temperatures between 290 and 550 K. It is found that the pressure-temperature cross derivative of the fluorescence wavelength shifts are negligible for both ruby and alexandrite.

Jahren, A. H.↗

Improvement of a large-amplitude sinusoidal pressure generator for dynamic calibration of pressure transducers

Results of research on the improvement of a sinusoidal pressure generator are presented. The generator is an inlet-area-modulated, gas-flow-through device (siren type) which was developed to dynamically calibrate pressure transducers and pressure probes. Tests were performed over a frequency range of 100 Hz to 20 kHz at average chamber pressures (bias pressure) between 30 and 50 psia (21 and 35 N/sq cm abs) and between 150 and 300 psia (104 and 207 N/sq cm abs). Significant improvements in oscillation pressure waveform were obtained but with reduction in available generator oscillation pressure amplitude range. Oscillation pressure amplitude, waveform, and waveform spectral content are given as functions of frequency for the two bias pressure conditions. The generator and instrumentation for frequency, amplitude, and spectrum measurements are described.

Robinson, R. E.↗

Oscillation pressure device for dynamic calibration of pressure transducers

Method and apparatus for obtaining dynamic calibrations of pressure transducers. A calibration head (15), a flexible tubing (23) and a bellows (20) enclose a volume of air at atmospheric pressure with a transducer (11) to be calibrated subject to the pressure inside the volume. All of the other apparatus in the drawing apply oscillations to bellows (20) causing the volume to change thereby applying oscillating pressures to transducer (11) whereby transducer (11) can be calibrated.

Hess, Robert W.↗

A temperature and pressure controlled calibration system for pressure sensors

A data acquisition and experiment control system capable of simulating temperatures from -184 to +220 C and pressures either absolute or differential from 0 to 344.74 kPa is developed to characterize silicon pressure sensor response to temperature and pressure. System software is described that includes sensor data acquisition, algorithms for numerically derived thermal offset and sensitivity correction, and operation of the environmental chamber and pressure standard. This system is shown to be capable of computer interfaced cryogenic testing to within 1 C and 34.47 Pa of single channel or multiplexed arrays of silicon pressure sensors.

Chapman, John J.↗

Inflatable bladder provides accurate calibration of pressure switch

Calibration of a pressure switch is accurately checked by a thin-walled circular bladder. It is placed in the pressure switch and applies force to the switch diaphragm when expanded by an external pressure source. The disturbance to the normal operation of the switch is minimal.

Smith, N. J.↗

A dynamic pressure source for the calibration of pressure transducers

A dynamic pressure source is described for producing sinusoidally varying pressures of up to 34 kPa zero to peak, over the frequency range of approximately 50 Hz to 2 kHz. The source is intended for the dynamic calibration of pressure transducers. The transducer to be calibrated is mounted near the base of the thick walled aluminum tube forming the vessel so that the pressure sensitive element is in contact with the liquid in the tube. A section of the tube is filled with small steel balls to damp the motion of the 10-St dimethyl siloxane working fluid in order to extend the useful frquency range to higher frequencies than would be provided by an undamped system. The dynamic response of six transducers provided by the sponsor was evaluated using the pressure sources; the results of these calibrations are given.

Vezzetti, C. F.↗

Miniature pressure valve for on-board calibration of pressure transducers.

This paper describes the development and testing of a miniature one-pole, three-position pressure valve and actuation mechanism. This valve was designed primarily for installation with a pressure transducer directly in a wind-tunnel model, thereby reducing lag time effects resulting from long connecting tubes to the transducer. This valve provides for the in-situ calibration of the transducer during testing by providing one position for transducer zero, a second position for a known calibrate pressure, and a third position for measurement of the unknown test pressure. The valve is driven from the spring loaded test pressure position to the zero and calibrate positions by a pneumatically operated dual-piston yoke assembly. Large numbers of transducers can be simultaneously calibrated from a remote location in a matter of seconds.

Rollins, G. N.↗

Dynamic Calibration of Pressure Transducers

Sinusoidal calibration signal produced in 4- to 100-Hz range. Portable oscillating-pressure device measures dynamic characteristics of pressure transducers installed in models or aircraft at frequency and oscillating-pressure ranges encountered during unsteady-pressure-measurement tests. Calibration is over range of frequencies and amplitudes not available with commercial acoustic calibration devices.

Hess, R. W.↗

Deadweight calibration of pressure gages without contamination

Calibration of pressure gages is accomplished by use of fluid chamber in conjunction with conventional single chamber hydraulic deadweight tester. System eliminates cleaning of gages with liquid oxygen after tests and is simple to construct and operate.

Hensley, D. R.↗

System enables more complete calibrations of dynamic-pressure transducers

Absolute pressure calibration system using a Michelson interferometer calibrates phase characteristics and pressure sensitivities of the transducers that monitor acoustic or aerodynamic pressure fields. The interferometer uses a helium-neon laser light source and interchangeable acoustic signal generators to produce acoustic waves.

Pernet, D. F.↗

Calibrating Nonremovable Pressure Transducers

Report describes supplementary calibration procedure for pressure transducers. Method developed for transducers that cannot be removed without damage. Units calibrated en masse in large pressure chamber.

Watts, Michael E.↗

Flexible arms provide constant force for pressure switch calibration

In-place calibration of a pressure switch is provided by a system of radially oriented flexing arms which, when rotated at a known velocity, convert the centrifugal force of the arms to a linear force along the shaft. The linear force, when applied to a pressure switch diaphragm, can then be calculated.

Cain, D. E.↗