Search NASASearch

SEARCH · Search NASA

Results for “preventative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Zoledronate Prevents Simulated Weightlessness-Induced Bone Loss in the Cancellous Compartment While Blunting the Efficacy of a Mechanical Loading Countermeasure

Astronauts using high-force resistance training while weightless show a high-turnover remodeling state within the skeletal system, with resorption and formation biomarkers being elevated. One countermeasure for the skeletal health of astronauts includes an antiresorptive of the bisphosphonate (BP) drug class. We asked, does the combination of an anti-resorptive and high-force exercise during weightlessness have negative effects on bone remodeling and strength? In this study, we developed an integrated model to mimic the mechanical strain of exercise via cyclical loading (CL) in mice treated with the BP Zoledronate (ZOL) combined with hind limb unloading (HU) to simulate weightlessness. We hypothesized that ZOL prevents structural degradation from simulated weightlessness and that CL and ZOL interact to render CL less effective. Thirty-two C57BL/6 mice (male, 16 weeks old, n=8/group) were exposed to 3 weeks of either HU or normal ambulation (NA). Cohorts of mice received one subcutaneous injection of ZOL (45μg/kg), or saline vehicle (VEH), prior to the start of HU. The right tibia was axially compressed in vivo 60x/day to 9N (+1200μstrain on the periosteal surface) and repeated 3x/week during HU. Left tibiae served as a within subject, non-compressed control. Ex vivo μCT was performed on all subjects to determine cancellous and cortical architectural parameters. Static and dynamic histomorphometry were carried out for the left and right tibiae to determine osteoclast- and osteoblast relevant surfaces. Further, micro damage was assessed in select groups by basic-fuchsin staining to test whether CL had an effect. For all assays, a multivariate (2x2x2) ANCOVA model was used to account for body weight changes. Additionally, for the tibiae, we incorporated a random effect for the subject (hence, a mixed model) to account for observations of both left and right tibiae within each subject. P < 0.05 was considered significant. In the cancellous compartment of the proximal tibial metaphysis, we observed a main effect from each independent variable, as determined by structural and histomorphometric assays. Specifically, as expected, ZOL showed an increase in the cancellous bone volume to total volume fraction (BV/TV, +32%) and trabecular number (+18%) compared to the VEH. As expected, ZOL decreased osteoclast surface (OC/BS) by -45% compared to VEH. Surprisingly, ZOL reduced mineralizing surface (MS/BS) and bone formation rate (BFR), indicators of osteoblast activity, by -40% and -54%, respectively, compared to VEH. Altogether, ZOL-treated mice displayed a low turnover state of remodeling in the metaphysis. In the context of skeletal aging, we speculate that ZOL prevented age-related cancellous strut loss during the experiment. As a main effect, as expected, HU decreased BV/TV by - 31% via reductions in both trabecular thickness (-11%) and number (-22%) compared to NA controls. Additionally, HU decreased MS/BS by -38% and bone formation rate (BFR) by -50% compared to NA controls. Altogether, these data are consistent with structural degradation resulting from imbalanced remodeling that favors resorption. As a main effect, CL increased BV/TV by +15% via increased trabecular thickness (+12%) compared to the noncompressed limb. As expected, CL increased MS/BS (+20%) and BFR (+24%), indicating osteoblast mineralization contributed to bone gains. These data show that CL provided an anabolic stimulus to the cancellous tissue. We observed unique interactions in ZOL*CL and HU*CL. First, ZOL prevented CL-induced increases in BV/TV and trabecular number, as compared to VEH. In the context of skeletal aging, these data suggest no added benefit from CL in the ZOL-treated mice. Interestingly, no microdamage was observed in mice that were unloaded and treated with ZOL (independent of CL). Secondly, HU prevented CL-induced increases in BFR, as compared to NA controls. These data suggest that either exercise is less effective or the kinetics of formation are slower during simulated weightlessness. Osteoclast surface was unchanged by either treatment. Thus, in contrast to exercising astronauts, these data do not suggest a high-turnover state in the metaphysis. To assess mechanical properties as a function of HU or ZOL, we tested the left femur in three-point bending ex vivo. As expected, HU decreased stiffness (-30%) compared to NA, and ZOL increased stiffness compared to VEH (+28%). Interestingly, HU increased the post-yield displacement, related to collagenous tensile loading, compared to NA (+20%). ZOL increased yield force (+11%) and ultimate force (+17%), which seems to explain the significant effect of ZOL increasing total energy (work-to-fracture, +15%), while not affecting the post yield displacement. Taken together, ZOL did not have detrimental affect on mechanical properties. Our integrated model simulates the combination of weightlessness, exercise-induced mechanical strain, and anti-resorptive treatment that astronauts experience during space missions. We conclude that Zoledronate was an effective countermeasure against weightlessness-induced bone loss, though zoledronate, as well as weightlessness, rendered exercise-related mechanical loading less effective.

bone

Designing Graceful Degradation into Complex Systems: The Interaction Between Causes of Degradation and the Association with Degradation Prevention and Recovery

System resilience is critical to safety in air traffic control. An important element of maintaining resilience is the ability of systems to degrade gracefully. Of the available graceful degradation research, a majority of studies have focused primarily on technological causes of degradation only, limiting an ecologically valid understanding of the causes of degradation in air traffic control, and the preventative and mitigative strategies that enable graceful degradation. The current study aimed to address this research gap by investigating causes of degradation in air traffic control (ATC) across the broad categories of technology, the environment, and the human operator, and the potential interactions between these causes. 12 retired controllers (ATCOs - Air Traffic Control Officers) participated in semi-structured interviews focused on previous experience of causes of degradation and mitigation strategies. Findings provide an understanding of causation of degradation in air traffic control, and the prevention and mitigation strategies that moderate the relationship between cause and system effect. Findings confirmed that causes appear to interact to create compound, multiple effects on overall system performance. Findings also revealed prevention and mitigation strategies utilized to moderate the effect of the cause on the system. In order to gain an ecologically valid understanding of the causes of degradation, and effective prevention or mitigation strategies, causes from multiple categories, and the interactions between them, must be identified. Findings have implications for designers of future air traffic control systems to ensure the ability of the system to gracefully degrade, as well as risk assessment and system validation processes.

Graceful Degradation

Prevention of Spaceflight-Induced Bone Loss: A Promising Dietary Countermeasure

Space radiation is one of the challenges for long-term spaceflight, especially for missions beyond low Earth Orbit. We have shown that a diet composed of 25% dried plum (DP) prevents radiation-induced bone loss. The DP diet fully protected the cancellous bone microarchitecture of mice exposed to ionizing radiation (gamma, proton, and HZE). In particular relevant to space radiation, we showed that the DP diet prevents bone loss due to 1Gy of sequential exposure of proton (1H, low linear energy transfer -LET-), and 1Gy of iron (56Fe, high-LET). In addition, total body exposure to 1Gy of HZE radiation (56Fe) impaired the osteoprogenitors in mice fed the control diet, as indicated by decreased osteoblast mineralization. In contrast, marrow stem cells from mice fed the DP did not exhibit these deficits. Based on these promising results supporting DP as a countermeasure to prevent space radiation induced-tissue damage, we conducted additional studies to combine radiation and simulated microgravity. We exposed skeletally mature male mice to simulated microgravity (using hindlimb unloading, HU) or total body irradiation (TBI, 2Gy 137Cs) or in combination (HU+TBI). We observed bone loss in the mice fed the control diet (CD) exposed to simulated spaceflight, as measured by cancellous bone microarchitecture parameters such as percent bone volume (BV/TV). In contrast, mice fed the DP diet did not exhibit similar bone loss with either treatments (HU or TBI) or combined (HU+TBI) as seen in most parameters. This was observed in both long bones (tibia) and axial bones (vertebrae). Furthermore, preliminary data shows that pre-feeding with the DP diet attenuates the HU-induced decrement in bone-forming osteoblasts colony counts and mineralization capacity of the osteoprogenitor cells. We also performed DP feeding at lower doses (5%, 10%) and found that these doses are less effective in preventing the radiation-induced bone loss. All our studies with the DP diet as a countermeasure were done with a period of pre-feeding ranging from 14 to 21 days before irradiation, and in order to test the capacity of the DP diet as a countermeasure provided after exposure to radiation, we exposed mice to 2Gy gamma radiation and then provided the DP diet 24 hours post-IR. Preliminary data indicates that DP mitigated the radiation-induced deficits in certain cancellous bone structural parameters. Finally, we showed that mice fed with the control diet (CD) increased oxidative damage in the serum after radiation exposure, whereas mice fed the DP diet do did not show such an increase. In summary, the DP diet is a promising countermeasure for spaceflight-induced tissue damage.

Schreurs, Ann-Sofie

A Survey on the Design, Detection, and Prevention of Pre-Silicon Hardware Trojans

The complexity of the semiconductor design lifecycle and globalized manufacturing process creates concern over the threat of deliberate malicious alterations, or hardware Trojans, being inserted into microelectronic designs. This has resulted in a significant corpus of hardware Trojan research including Trojan design and benchmarking efforts and development of corresponding metrics and detection and prevention techniques, over the last two decades. In this survey, we first highlight efforts in Trojan design and benchmarking, followed by a cataloging of seminal and recent works in Trojan detection and prevention and their accompanied metrics. Given the volume of literature in this field, this survey considers only pre-silicon techniques. We make this distinction between pre- and post-silicon to properly scope and provide appropriate context into the capabilities of existing hardware Trojan literature. Each major section (design, prevention, and detection) is accompanied by insights, and common pitfalls, which we highlight can be addressed by future research.

42 ENGINEERING

Use of differential plasma rotation to prevent disruptive tearing mode onset from 3-wave coupling

Abstract Plasma differential rotation is found to be capable of preventing disruptive neoclassical tearing modes (NTMs) seeded by nonlinear three-wave coupling. As tearing modes degrade confinement and can lead to disruptions, stabilization strategies are crucial to the successful operation of future devices. In ITER-relevant scenarios on DIII-D, rotationally coupled m / n = 1/1 and 3/2 modes have been observed to drive 2/1 islands through three-wave coupling. The frequency of the driven 2/1 mode is set by matching conditions and the frequencies of the driving modes. When the driven mode frequency matches the local plasma rotation frequency, e.g. at low differential rotation, the driven 2/1 island can grow into a disruptive NTM. Using neutral beam torque as an actuator to scan the differential rotation, these experiments demonstrate that a sufficiently large frequency mismatch prevents destabilization of disruptive 2/1 NTMs by three-wave coupling. This work indicates that differential rotation can be used as an actuator to prevent NTMs seeded by three-wave coupling.

Richner, N. J. (ORCID:0000000155443915)

Detecting Anomalies for Fire Prevention in Distribution Systems: Challenges and Analytical Techniques

Electric utilities in California have historically been linked to up to 10% of wildfires. To mitigate this risk, Southern California Edison has invested significantly in wildfire prevention strategies, including undergrounding cables and enhancing equipment inspections. This article explores a novel approach to fire prevention by detecting anomalies in the distribution system that may indicate potential fire hazards. The focus is on identifying arcing conditions through high-resolution point-on-wave (POW) measurements. Arcing, a precursor to fires, is challenging to detect due to its subtle transients and complex system topology. The article discusses the use of advanced signal processing and machine learning techniques, such as spectral correlation function and discrete wavelet transform, to extract features from POW data and accurately identify arcing events. The study demonstrates a high accuracy rate in detecting arcing, paving the way for improved fire prevention measures in electric distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION

Adaptive Framework for Maintenance Scheduling Based on Dynamic Preventive Intervals and Remaining Useful Life Estimation

Data-based prognostic methods exploit sensor data to forecast the remaining useful life (RUL) of industrial settings to optimize the scheduling of maintenance actions. However, implementing sensors may not be cost-effective or practical for all components. Traditional preventive approaches are not based on sensor data; however, they schedule maintenance at equally spaced intervals, which is not a cost-effective approach since the distribution of the time between failures changes with the degradation state of other parts or changes in working conditions. This study introduces a novel framework comprising two maintenance scheduling strategies. In the absence of sensor data, we propose a novel dynamic preventive policy that adjusts intervention intervals based on the most recent failure data. When sensor data are available, a method for RUL prediction, designated k-LSTM-GFT, is enhanced to dynamically account for RUL prediction uncertainty. The results demonstrate that dynamic preventive maintenance can yield cost reductions of up to 51.8% compared to conventional approaches. The predictive approach optimizes the exploitation of RUL, achieving costs that are only 3–5% higher than the minimum cost achievable while ensuring the safety of critical systems since all of the failures are avoided.

Nunes, Pedro (ORCID:0000000180012172)

Manufacturing contamination prevention handbook

Manufacturing management discipline handbook concerning contamination prevention may present principles and guidelines which can be adopted for industrial and commercial manufacturer usage. Contamination prevention program is categorized into three basic aspects: initial prevention; control of amount of unpreventable contamination; and detection and elimination of remaining contamination.

Mackey, R. T., Sr.

Preventing Cracks in Silicon-Reactor Liners

Correct placement helps prevent contamination while eliminating crack-causing deposits. Repositioning quartz liner in silicon fluidized-bed reactor prevents cracking of liner when cools. Liner protects stainless-steel walls of reactor from abrasion by particles in fluidized bed. Prevents contamination of newly formed silicon by material abraded from wall and ensures high-quality product.

Lutwack, R.

Corrosion Prevention in Copper Combustion Chamber Liners of Liquid Oxygen/Methane Booster Engines

Prior research conducted by United Technologies Research Center and Rockwell International Rocketdyne Division encountered severe copper corrosion while flowing hydrocarbon fuels through copper cooling tubes. These experimental results have very important implications for the development of low-cost, regeneratively cooled, oxygen/hydrocarbon bipropellant booster engines. Aerojet TechSystems undertook a program sponsored by NASA/Lewis Research Center in 1986 with two objectives: (1) to define the corrosive interaction process that occurs between hydrocarbon fuels and copper combustion chamber liner materials, using both static and dynamic test methods, and (2) to identify and demonstrate protective measures against this corrosive process. The results of the first program task demonstrated that the most damaging corrosive process was caused by trace amounts of sulfur-containing impurities in the hydrocarbon fuel which react with the copper chamber liner material to form cuprous sulfide (Cu2S), as reported in Paper No. AlAA 88-3215. Experiments were conducted which demonstrated this corrosive process with Mil-Spec RP-1, propane, and methane fuels in contact with OFHC, NASA-Z, and ZrCu coppers. The preliminary results of the second program task demonstrated that electrodeposited gold and platinum coatings held promise of preventing corrosion of copper chamber liners by methane contaminated with sulfur-containing impurities, as reported in Paper No. AIAA 89-2738. Experiments were conducted which demonstrated greatly reduced corrosion of copper by hydrogen sulfide (H2S) and methyl mercaptan (CH3SH) as measured impurities in methane. This paper presents the concluding, confirmatory results from the second program task. The efficacy of a protective gold coating on NASA-Z copper cooling channel walls was conclusively demonstrated. Tests were conducted in the Aerojet Carbothermal Test Facility which provide realistic simulations of booster engine cooling channel conditions such as temperature, pressure, flow velocity, and heat flux. Dynamic test series were performed with methane containing 5 and 10 ppm (by volume) hydrogen sulfide. Gold-plated and unplated copper alloy specimens were evaluated. The tests demonstrated that gold coatings were effective in preventing corrosion of the copper. Posttest metallographic examinations of the unplated specimens showed severe corrosion as a result of reaction with the sulfur containing contaminant in the fuel. In contrast, posttest metallographic examination of the gold-coated specimens showed no corrosion under similar operating conditions. The findings from metallurgical and chemical analyses of the copper specimens, chemical analysis of the methane, and description of all test conditions are provided. Conclusions are reached as to the efficacy of the plating methods and the effectiveness of the metal coatings in the prevention of corrosion in hydrocarbon-fueled booster engine combustion chamber liners.

S D Rosenberg

Prevention of accretion onto white dwarfs by stellar winds

There is indirect observational evidence that hot white dwarfs may have weak stellar winds. In this paper, the interaction between such a wind and the flow of ISM material in the gravitational field of the white dwarf is investigated with the aim of finding limits on the mass-loss rate and terminal velocity of winds capable of preventing accretion from the ISM. The limiting cases of no relative motion of the star and the ISM and supersonic relative motion of the star through ISM are separately investigated. Each case is treated by generalizing models for the interaction between the solar wind and the local ISM to include the effects of gravity. It is found that, for wind velocities expected for radiatively driven winds, mass-loss rates as low as 10 exp -21 solar mass/yr are sufficient to prevent accretion from the hot phase of the ISM. To prevent accretion during passages through cold clouds, wind mass-loss rates of order 10 exp -18 to 10 exp -17 are required.

Macdonald, James

An Investigation of the Prevention of Ice on the Airplane Windshield

An investigation of three methods for the prevention and the removal of ice on an airplane windshield has been completed. The methods were: electric heating; hot-air heating; and an alcohol-dispensing, rotating wiper blade. The results showed that vision through the airplane windshield could be maintained during severe icing conditions by the use of heat. When put in operation prior to the formation of ice on the windshield the rotating wiper blade prevented the formation of ice. A combination of heated air and a rotating wiper blade would appear to protect against formation of ice on the windshield exterior, to prevent frost on the interior and to provide for the removal of rainfall.

Rodert, Lewis A

Design of a vehicle based system to prevent ozone loss

Reduced quantities of ozone in the atmosphere allow greater levels of ultraviolet light (UV) radiation to reach the earth's surface. This is known to cause skin cancer and mutations. Chlorine liberated from Chlorofluorocarbons (CFC's) and natural sources initiate the destruction of stratospheric ozone through a free radical chain reaction. The project goals are to understand the processes which contribute to stratospheric ozone loss, examine ways to prevent ozone loss, and design a vehicle-based system to carry out the prevention scheme. The 1992/1993 design objectives were to accomplish the first two goals and define the requirements for an implementation vehicle to be designed in detail starting next year. Many different ozone intervention schemes have been proposed though few have been researched and none have been tested. A scheme proposed by R.J. Cicerone, Scott Elliot and R.P.Turco late in 1991 was selected because of its research support and economic feasibility. This scheme uses hydrocarbon injected into the Antarctic ozone hole to form stable compounds with free chlorine, thus reducing ozone depletion. Because most polar ozone depletion takes place during a 3-4 week period each year, the hydrocarbon must be injected during this time window. A study of the hydrocarbon injection requirements determined that 100 aircraft traveling Mach 2.4 at a maximum altitude of 66,000 ft. would provide the most economic approach to preventing ozone loss. Each aircraft would require an 8,000 nm. range and be able to carry 35,000 lbs. of propane. The propane would be stored in a three-tank high pressure system. Missions would be based from airport regions located in South America and Australia. To best provide the requirements of mission analysis, an aircraft with L/D(sub cruise) = 10.5, SFC = 0.65 (the faculty advisor suggested that this number is too low) and a 250,000 lb TOGW was selected as a baseline. Modularity and multi-role functionality were selected to be key design features. Modularity provides ease of turnaround for the down-time critical mission. Multi-role functionality allows the aircraft to be used beyond its design mission, perhaps as an High Speed Civil Transport (HSCT) or for high altitude research.

Lynn, Sean R.

Environmental testing to prevent on-orbit TDRS failures

Can improved environmental testing prevent on-orbit component failures such as those experienced in the Tracking and Data Relay Satellite (TDRS) constellation? TDRS communications have been available to user spacecraft continuously for over 11 years, during which the five TDRS's placed in orbit have demonstrated their redundancies and robustness by surviving 26 component failures. Nevertheless, additional environmental testing prior to launch could prevent the occurrence of some types of failures, and could help to maintain communication services. Specific testing challenges involve traveling wave tube assemblies (TWTA's) whose lives may decrease with on-off cycling, and heaters that are subject to thermal cycles. The development of test conditions and procedures should account for known thermal variations. Testing may also have the potential to prevent failures in which components such as diplexers have had their lives dramatically shortened because of particle migration in a weightless environment. Reliability modeling could be used to select additional components that could benefit from special testing, but experience shows that this approach has serious limitations. Through knowledge of on-orbit experience, and with advances in testing, communication satellite programs might avoid the occurrence of some types of failures, and extend future spacecraft longevity beyond the current TDRS design life of ten years. However, determining which components to test, and how must testing to do, remain problematical.

Cutler, Robert M.

Preventing Damaging Pressure Gradients at the Walls of an Inflatable Space System

An inflatable structural system to deploy a space system such as a solar shield, an antenna or another similar instrument, requires a stiffening element after it is extended by the inflated gas pressure. The stiffening element has to be packaged in a folded configuration before the deployment. It must be relatively small, lightweight, non-damaging to the inflated system, and be able to become stiff in a short time. One stiffening method is to use a flexible material inserted in the deployable system, which, upon a temperature curing, can become stiff and is capable to support the entire structure. There are two conditions during the space operations when the inflated volume could be damaged: during the transonic region of the launch phase and when the curing of the rigidizing element occurs. In both cases, an excess of pressure within the volume containing the rigid element could burst the walls of the low-pressure gas inflated portion of the system. This paper investigates those two conditions and indicates the vents, which will prevent those damaging overpressures. Vent openings at the non-inflated volumes have been calculated for the conditions existing during the launch. Those vents allow the initially folded volume to exhaust the trapped atmospheric gas at approximately the same rate as the ambient pressure drops. That will prevent pressure gradients across the container walls which otherwise could be as high as 14.7 psi. The other condition occurring during the curing of the stiffening element has been investigated. This has required the testing of the element to obtain the gas generation during the curing and the transformation from a pliable material to a rigid one. The tested material is a composite graphite/epoxy weave. The outgassing of the uncured sample at 121C was carried with the Cahn Microbalance and with other outgassing facilities including the micro-CVCM ASTM E-595 facility. The tests provided the mass of gas evolved during the test. That data, including the chemical nature of the evolved gas, provided the data for the calculation of the pressure produced within the volume. The evaluation of the areas of the vents that would prevent excessive pressures and provide a rapid release of the gas away from contamination sensitive surfaces has been carried out. The pressure decay with time has been indicated.

Scialdone, John J.

Heat Sink Welding for Preventing Hot Cracking in Alloy 2195 Intersection Welds: A Feasibility Study

Two concepts, stationary cooling and trailing cooling, were proposed to prevent weld intersection cracking. Finite element analysis was used to demonstrate the potential effectiveness of those two concepts. Both stationary and trailing heat sink setups were proposed for preventing intersection cracking. The cooling media could be liquid nitrogen, or pressured air knife. Welding experiments on the small test panel with the localized heat sink confirmed the feasibility of using such a stationary cooling technique. The required cooling was achieved in this test panel. Systematic welding experiments should be conducted in the future to validate and refine the heat sink technique for preventing intersection cracking.

Yang, Yu-Ping

Preventing Damaging Pressure Gradients at the Walls of an Inflatable Space System

An inflatable structural system to deploy a space system such as a solar shield, an antenna or another similar instrument requires a stiffening element after it is extended by the inflated gas pressure. The stiffening element has to be packaged in folded configuration before the deployment. It must be relatively small, lightweight, non-damaging to the inflated system and be able to become stiff in a short time. One stiffening method is to use a flexible material inserted in the deployable system, which, upon a temperature curing, can become stiff and is capable of supporting the entire structure. There are two conditions during the space operations when the inflated volume could be damaged: during the transonic region of the launch phase and when the curing of the rigidizing element occurs. In both cases, an excess of pressure within the volume containing the rigid element could burst the walls of the low-pressure gas inflated portion of the system. This paper investigates those two conditions and indicates the vents, which will prevent those damaging overpressures. Vent openings at the non-inflated volumes have been calculated for the conditions existing during the launch. Those vents allow the initially folded volume to exhaust the trapped atmospheric gas at approximately the same rate as the ambient pressure drops. That will prevent pressure gradients across the container walls which otherwise could be as high as 14.7 psi. The other condition occurring during the curing of the stiffening element has been investigated. This has required the testing of the element to obtain the gas generation during the curing and the transformation from a pliable material to a rigid on The tested material is a composite graphite/epoxy weave. The outgassing of the uncured sample at 121 deg Celcius was carried with the Cahn Microbalance and with other outgassing facilities including the micro-CVCM ASTM E-595 facility. The test provided the mass of gas evolved during the test. That data, including the chemical nature of the evolved gas, provided the data for the calculation of the pressure produced within the volume. The evaluation of the areas of the vents that would prevent excessive pressures and provide a rapid release of the gas away from contamination sensitive surfaces has be carried out. The pressure decay with time has been indicated.

Scialdone, John J.

Preventing Spacecraft Failures Due to Tribological Problems

Many mechanical failures that occur on spacecraft are caused by tribological problems. This publication presents a study that was conducted by the author on various preventatives, analyses, controls and tests (PACTs) that could be used to prevent spacecraft mechanical system failure. A matrix is presented in the paper that plots tribology failure modes versus various PACTs that should be performed before a spacecraft is launched in order to insure success. A strawman matrix was constructed by the author and then was sent out to industry and government spacecraft designers, scientists and builders of spacecraft for their input. The final matrix is the result of their input. In addition to the matrix, this publication describes the various PACTs that can be performed and some fundamental knowledge on the correct usage of lubricants for spacecraft applications. Even though the work was done specifically to prevent spacecraft failures the basic methodology can be applied to other mechanical system areas.

Fusaro, Robert L.