Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis of Pull Force Test Results for Crimped Connections

Crimped electrical contacts are reliable when strict process controls are followed during manufacturing and accompanied by continuous process verification through pull force testing. Cable and wire harness assemblies’ standards are developed and refined over time to provide the minimum pull force that a crimp contact must meet before it breaks from the wire. However, in practice the failures occur at a much higher tensile strength than the minimum required. The first section of this paper reviewed 780 pull force test results provided by NASA Centers were collected and analyzed to determine how the data compares to NASA’s pre-existing requirements from the cable/harness standards NASA-STD-8739.4 and IPC/WHMA-A-620B-S. The measured tensile strength of most of the contact/conductor pairs (i.e. Contact/Wires or C/W) exceeded the minimum pull force values of NASA-STD-8739.4 and IPC/WHMA-A-620 standards by at least 100 %. The tensile strength samples of the C/W pairs values followed a normal distribution with an average tensile strength value that was at least 182 % of the minimum requirement, and all the samples analyzed passed the pull force testing. In addition, the 95 % confidence interval of the average tensile strength distributions for several C/W pairs was determined and plotted as error bars to show that there is good likelihood to observe C/W pair normal distribution with a 95 % confidence interval that will meet and surpass the standard requirements. The frequency of pull force testing can be problematic for projects because of the cost and availability of spare contacts for the destructive test. It could be possible to reduce the frequency of pull force testing if at the beginning of the production run, the conditions of the crimp tool and materials are verified, and the settings of the tool remain unchanged throughout the process. However, the project must evaluate the impact to risk from reducing the frequency of testing.

Crimped connections↗

Pull-out simulations of a capped carbon nanotube in carbon nanotube-reinforced nanocomposites

Systematic atomic simulations based on molecular mechanics were conducted to investigate the pull-out behavior of a capped carbon nanotube (CNT) in CNT-reinforced nanocomposites. Two common cases were studied: the pull-out of a complete CNT from a polymer matrix in a CNT/polymer nanocomposite and the pull-out of the broken outer walls of a CNT from the intact inner walls (i.e., the sword-in-sheath mode) in a CNT/alumina nanocomposite. By analyzing the obtained relationship between the energy increment (i.e., the difference in the potential energy between two consecutive pull-out steps) and the pull-out displacement, a set of simple empirical formulas based on the nanotube diameter was developed to predict the corresponding pull-out force. The predictions from these formulas are quite consistent with the experimental results. Moreover, the much higher pull-out force for a capped CNT than that of the corresponding open-ended CNT implies a significant contribution from the CNT cap to the interfacial properties of the CNT-reinforced nanocomposites. This finding provides a valuable insight for designing nanocomposites with desirable mechanical properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ring Pull Strain Analysis Version 1.1

This report details an analysis package, Ring Pull Strain Analysis (RPSA), that can be used to present and quantify digital image correlation (DIC) data as it relates to a gaugeless ring pull test. Gaugeless ring pull is a testing technique for mechanical testing of small annular samples, usually cut from a thin-walled tube. DIC data is often necessary for this kind of test because bending moments present on the ring cause a non-uniform strain distribution and localized measurements are necessary. In addition, the annular geometry of a ring lends itself to a polar representation, which is not present with typical DIC analysis methods. RPSA was made to calculate and plot the polar representation of strain from standard pre-processed DIC data of a gaugeless ring pull test. Further analysis can be done on ring pull including a quasi-uniaxial tensile analysis and coating analysis, which are also performed by RPSA. In addition, due to the universality of DIC plotting and ring pull test analysis, RPSA can accommodate a wide variety of tests, though it is tailored for ring pull testing. This report details how RPSA works, including the theory, assumptions, and logic behind the calculations and the structure of the program.

36 MATERIALS SCIENCE↗

Analysis of Pull Force Test Results for Crimped Connections

Crimped electrical contacts are reliable when strict process controls are followed during manufacturing and accompanied by continuous process verification through pull force testing. Cable and wire harness assemblies’ standards are developed and refined over time to provide the minimum pull force that a crimp contact must meet before it breaks from the wire. However, in practice the failures occur at a much higher tensile strength than the minimum required. The first section of this paper reviewed 780 pull force test results provided by NASA Centers that were collected and analyzed to determine how the data compare to NASA’s pre-existing requirements from the cable/harness standards NASA-STD-8739.4 and IPC/WHMA-A-620B-S. The measured tensile strength of most of the contact/conductor pairs (i.e., Contact/Wires or C/W) exceeded the minimum pull force values of NASA-STD-8739.4 and IPC/WHMA-A-620 standards by at least 100%. The C/W pair samples’ tensile strength values followed a normal distribution with an average tensile strength value that was at least 182% of the minimum requirement, and all the samples analyzed passed the pull force testing. In addition, the 95% confidence interval of the average tensile strength distributions for several C/W pairs was determined and plotted as error bars to show that the C/W pairs will meet and surpass the requirements. The frequency of pull force testing can be problematic for projects because of the cost and availability of spare contacts for the destructive test. It is possible to reduce the frequency of pull force testing if at the beginning of the production run, the conditions of the crimp tool and materials are verified, and the settings of the tool remain unchanged throughout the process. However, the project needs to understand and evaluate the impact to risk from reducing the frequency of testing prior to implementing process changes.

Alejandra Constante↗

Test and Analysis of Composite Hat Stringer Pull-off Test Specimens

Hat stringer pull-off tests were performed to evaluate the delamination failure mechanisms in the flange region for a rod-reinforced hat stringer section. A special test fixture was used to pull the hat off the stringer while reacting the pull-off load through roller supports at both stringer flanges. Microscopic examinations of the failed specimens revealed that failure occurred at the ply termination in the flange area where the flange of the stiffener is built up by adding 45/-45 tape plies on the top surface. Test results indicated that the as-manufactured microstructure in the flange region has a strong influence on the delamination initiation and the associated pull-off loads. Finite element models were created for each specimen with a detailed mesh based on micrographs of the critical location. A fracture mechanics approach and a mixed mode delamination criterion were used to predict the onset of delamination and the pull-off load. By modeling the critical local details of each specimen from micrographs, the model was able to accurately predict the hat stringer pull-off loads and replicate the variability in the test results.

Li, Jian↗

Push-Pull Locomotion for Vehicle Extrication

For applications in which unmanned vehicles must traverse unfamiliar terrain, there often exists the risk of vehicle entrapment. Typically, this risk can be reduced by using feedback from on-board sensors that assess the terrain. This work addressed the situations where a vehicle has already become immobilized or the desired route cannot be traversed using conventional rolling. Specifically, the focus was on using push-pull locomotion in high sinkage granular material. Push-pull locomotion is an alternative mode of travel that generates thrust through articulated motion, using vehicle components as anchors to push or pull against. It has been revealed through previous research that push-pull locomotion has the capacity for generating higher net traction forces than rolling, and a unique optical flow technique indicated that this is the result of a more efficient soil shearing method. It has now been found that pushpull locomotion results in less sinkage, lower travel reduction, and better power efficiency in high sinkage material as compared to rolling. Even when starting from an "entrapped" condition, push-pull locomotion was able to extricate the test vehicle. It is the authors' recommendation that push-pull locomotion be considered as a reliable back-up mode of travel for applications where terrain entrapment is a possibility.

extrication↗

Push-pull tests for estimating effective porosity: expanded analytical solution and in situ application

The analytical solution describing the one-dimensional displacement of the center of mass of a tracer during an injection, drift, and extraction test (push-pull test) was expanded to account for displacement during the injection phase. The solution was expanded to improve the in situ estimation of effective porosity. The truncated equation assumed displacement during the injection phase was negligible, which may theoretically lead to an underestimation of the true value of effective porosity. To experimentally compare the expanded and truncated equations, single-well push-pull tests were conducted across six test wells located in a shallow, unconfined aquifer comprised of unconsolidated and heterogeneous silty and clayey fill materials. The push-pull tests were conducted by injection of bromide tracer, followed by a non-pumping period, and subsequent extraction of groundwater. The values of effective porosity from the expanded equation (0.6–5.0%) were substantially greater than from the truncated equation (0.1–1.3%). The expanded and truncated equations were compared to data from previous push-pull studies in the literature and demonstrated that displacement during the injection phase may or may not be negligible, depending on the aquifer properties and the push-pull test parameters. The results presented here also demonstrated the spatial variability of effective porosity within a relatively small study site can be substantial, and the error-propagated uncertainty of effective porosity can be mitigated to a reasonable level (< ± 0.5%). The tests presented here are also the first that the authors are aware of that estimate, in situ, the effective porosity of fine-grained fill material.

58 GEOSCIENCES↗

On the pull-in behavior of optical injection phase-lock loop

This paper presents a detailed study of the pull-in behavior of an optical injection phase-lock loop (OIPLL) neglecting the noise components of the loop. We provide formulas for pull-in voltage and pull-in range of OIPLL in terms of the loop propagation delay, line-width enhancement factor and other parameters of the loop. In addition, we give a compact expression for the frequency pulling time of OIPLL for low injection and high injection level in presence of loop-delay. The effects of loop-delay and optical injection on the pull-in performance of the OIPLL are studied for non-zero values of line-width enhancement factor. Analytical expression of the maximum allowable loop delay is presented to study the deterministic stability of the loop. From the stochastic stability of the loop, we provide formula for the maximum value of the laser line-width to achieve the desired tracking performance. The simulation results are given in partial support of the conclusions of the analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An experimental investigation of silicon wafer surface roughness and its effect on the pull-strength of plated metals

Plated silicon wafers with surface roughness ranging from 0.4 to 130 microinches, subjected to tensile pull-strength tests, were analyzed. Results show that the measured pull-strength of plated metals decrease with increasing silicon surface roughness, effecting a weakening of the cohesive strength of the wafer, possibly caused by microcracks or 'etch pits' in the silicon surface. The mean value of pull-strength for all wafers plated with the Ni-Cu-Cu sequence exceeded the required 450 g/0.02 sq cm, and at Ra = 0.4 microinches, the mean pull-strength for the Ni-Cu-Cu and Ni-Cu wafers were 2290 and 850 g/0.02 sq cm, respectively. The development of standardized methods for measuring contact pull-strength is suggested. These results may have some bearing on solar cell arrays problems.

Spiers, G. D.↗

Analysis of Carbon Nanotube Pull-out from a Polymer Matrix

Molecular dynamics (MD) simulations of carbon nanotube (NT) pull-out from a polymer matrix are carried out. As the NT pull-out develops in the simulation, variations in the displacement and velocities of the NT are monitored. The existence of a carbon-ring-based period in NT sliding during pull-out is identified. Linear trends in the NT velocity-force relation are observed and used to estimate an effective viscosity coefficient for interfacial sliding at the NT/polymer interface. As a result, the entire process of NT pull-out is characterized by an interfacial friction model that is based on a critical pull-out force, and an analog of Newton's friction law used to describe the NT/polymer interfacial sliding.

Frankland, S. J. V.↗

Station Program Note Pull Automation

Upon commencement of my internship, I was in charge of maintaining the CoFR (Certificate of Flight Readiness) Tool. The tool acquires data from existing Excel workbooks on NASA's and Boeing's databases to create a new spreadsheet listing out all the potential safety concerns for upcoming flights and software transitions. Since the application was written in Visual Basic, I had to learn a new programming language and prepare to handle any malfunctions within the program. Shortly afterwards, I was given the assignment to automate the Station Program Note (SPN) Pull process. I developed an application, in Python, that generated a GUI (Graphical User Interface) that will be used by the International Space Station Safety & Mission Assurance team here at Johnson Space Center. The application will allow its users to download online files with the click of a button, import SPN's based on three different pulls, instantly manipulate and filter spreadsheets, and compare the three sources to determine which active SPN's (Station Program Notes) must be reviewed for any upcoming flights, missions, and/or software transitions. Initially, to perform the NASA SPN pull (one of three), I had created the program to allow the user to login to a secure webpage that stores data, input specific parameters, and retrieve the desired SPN's based on their inputs. However, to avoid any conflicts with sustainment, I altered it so that the user may login and download the NASA file independently. After the user has downloaded the file with the click of a button, I defined the program to check for any outdated or pre-existing files, for successful downloads, to acquire the spreadsheet, convert it from a text file to a comma separated file and finally into an Excel spreadsheet to be filtered and later scrutinized for specific SPN numbers. Once this file has been automatically manipulated to provide only the SPN numbers that are desired, they are stored in a global variable, shown on the GUI, and transferred over to a new Excel worksheet for comparison. I managed to get my application to acquire the CSWG (Computer Safety Working Group) and the SPNWG (Space Station Working Group) SPN's with just two mouse clicks for each pull, as opposed to several from the original process. When all three pulls are performed, an Excel sheet containing all three different results will be generated for the user to compare and determine which SPN's will be presented or reviewed the following month. The experience from this internship has been spectacular. As a high school senior who will begin attending college in the fall, this internship has been both educationally and occupationally beneficial. The internship has allowed me the opportunities to learn new programming languages, effectively network with NASA personnel from a variety of departments at JSC, and allowed me to learn new professional skills and etiquette. My internship at NASA's Johnson Space Center has further motivated me to pursue a Master's degree in Software Engineering and strive for a prosperous career with NASA as a civil servant.

Delgado, Ivan↗

Laboratory pull-out tests on fully grouted rock bolts and cable bolts: Results and lessons learned

Laboratory pull-out tests were conducted on the following rock bolts and cable bolts: steel rebars, smooth steel bars, fiberglass reinforced polymer threaded bolts, flexible cable bolts, IR5/IN special cable bolts and Mini-cage cable bolts. The diameter of the tested bolts was between 16 mm and 26 mm. The bolts were grouted in a sandstone sample using resin or cement grouts. The tests were conducted under either constant radial stiffness or constant confining pressure boundary conditions applied on the outer surface of the rock sample. In most tests, the rate of displacement was about 0.02 mm/s. The tests were performed using a pull-out bench that allows testing a wide range of parameters. This paper provides an extensive database of laboratory pull-out test results and confirms the influence of the confining pressure and the embedment length on the pull-out response (rock bolts and cable bolts). Furthermore, it also highlights the sensitivity of the results to the operating conditions and to the behavior of the sample as a whole, which cannot be neglected when the test results are used to assess the bolt-grout or the grout–rock interface.

42 ENGINEERING↗

CO2 Push-Pull Dual (Conjugate) Faults Injection Simulations

This submission contains datasets and a final manuscript associated with a project simulating carbon dioxide push-pull into a conjugate fault system modeled after Dixie Valley- sensitivity analysis of significant parameters and uncertainty prediction by data-worth analysis. Datasets include: (1) Forward simulation runs of standard cases (push & pull phases), (2) Local sensitivity analyses (push & pull phases), and (3) Data-worth analysis (push & pull phases).

15 GEOTHERMAL ENERGY↗

Growth, structural and optical characterizations of LiLa{sub (1-x)}Eu{sub x}(WO{sub 4}){sub 2} single-crystalline fibers by the micro-pulling-down method

Highlights: Black-Right-Pointing-Pointer Transparent and uniform LiLa{sub (1-x)}Eu{sub x}(WO{sub 4}){sub 2} single-crystalline fibers were grown by the micro-pulling-down method. Black-Right-Pointing-Pointer Alkali and rare earth ionic radii influence the pulling rate on the growth. Black-Right-Pointing-Pointer Eu incorporation in LiLa(WO{sub 4}){sub 2} induces local distortions in the crystalline lattice. Black-Right-Pointing-Pointer LiLa{sub (1-x)}Eu{sub x}(WO{sub 4}){sub 2} single-crystalline fibers present intense red emission under 395 nm excitation. Black-Right-Pointing-Pointer Concentration quenching observed in the emission around 20 mol% of Eu doping. -- Abstract: Transparent and uniform LiLa{sub (1-x)}Eu{sub x}(WO{sub 4}){sub 2} single-crystalline fibers where x = 0.005, 0.01, 0.03, 0.05, 0.07, 0.1, 0.15, 0.2, 0.25 and 1.0, with an average of 20-40 mm length were obtained by the micro-pulling-down method aiming structural and optical characterization. The optimum pulling rate was found to depend on the difference between alkali and rare earth ionic radii. Rietveld analysis from X-ray diffraction data and excitation spectroscopy at room temperature were applied to investigate the lattice changes due to the Eu{sup 3+} incorporation in the host. LiLa{sub (1-x)}Eu{sub x}(WO{sub 4}){sub 2} crystal fibers present red emission due to the electric dipole {sup 5}D{sub 0} {yields} {sup 7}F{sub 2} transition under 395 nm excitation showing a concentration quenching around 20 mol% of doping. The excitation spectra of the {sup 7}F{sub 0} {yields} {sup 5}D{sub 0} transition show small changes in the Eu{sup 3+} surroundings as function of dopant concentration.

36 MATERIALS SCIENCE↗

Distinguishing photo-induced oxygen attack on alkyl chain versus conjugated backbone for alkylthienyl-benzodithiophene (BDTT)-based push–pull polymers

Synthetic design has enabled increasing power conversion efficiency advances in organic photovoltaics (OPV). One continuing knowledge gap is detailed understanding of single-material chemical (photo)stability. Many considerations are based on prior OPV-relevant donor homopolymer systems rather than the next-generation push–pull architectures. Generally, energetic offsets between the lowest occupied molecular orbital of the donor and molecular oxygen are assumed to dictate kinetics of photo-induced charge transfer to a super oxide radical. Herein we determine the ambient-induced photo-degradation pathways, presented as proposed site-specific arrow-pushing mechanisms, for five donor polymers all containing the same push unit – alkylthienyl-substituted-benzodithiophene (BDTT) – but with chemically distinct pull units. The donor-only polymer films were subject to controlled photobleaching in air as an accelerated degradation approach, coupled with simultaneous monitoring of absorptance. Sample subsets were periodically removed and analyzed with X-ray photoelectron spectroscopy, to evaluate near-surface chemical composition and oxygen additions to hetero reporter atoms on either the BDTT push unit or distinct pull unit (i.e., sulphur and nitrogen). Here, this methodology allows us to distinguish between different mechanisms of bond cleavage and formation. Overall, we find that neither polymer redox properties nor individual push or pull unit stability are sufficient to predict photo-oxidative degradation of these polymers. Rather, there is a greater dependence on the susceptibility of unique structural groups within a polymeric system. Alkyl chain oxygen addition is generally the first attack site and direct sulfur oxidation on the conjugated backbone occurs after saturation of the alkyl chain initiation sites. This work provides a standard that could be used to evaluate relative photo-oxidative (in)stability for new OPV materials quickly – prior to time-consuming device optimization – and demonstrates an effective methodology for correlating optical degradation with chemical structure alterations via spectroscopic signatures to guide synthetic design.

14 SOLAR ENERGY↗

Quantitative in-situ scanning electron microscope pull-out experiments and molecular dynamics simulations of carbon nanotubes embedded in palladium

In this paper, we present our results of experimental and numerical pull-out tests on carbon nanotubes (CNTs) embedded in palladium. We prepared simple specimens by employing standard silicon wafers, physical vapor deposition of palladium and deposition of CNTs with a simple drop coating technique. An AFM cantilever with known stiffness connected to a nanomanipulation system was utilized inside a scanning electron microscope (SEM) as a force sensor to determine forces acting on a CNT during the pull-out process. SEM-images of the cantilever attached to a CNT have been evaluated for subsequent displacement steps with greyscale correlation to determine the cantilever deflection. We compare the experimentally obtained pull-out forces with values of numerical investigations by means of molecular dynamics and give interpretations for deviations according to material impurities or defects and their influence on the pull-out data. We find a very good agreement of force data from simulation and experiment, which is 17 nN and in the range of 10–61 nN, respectively. Our findings contribute to the ongoing research of the mechanical characterization of CNT-metal interfaces. This is of significant interest for the design of future mechanical sensors utilizing the intrinsic piezoresistive effect of CNTs or other future devices incorporating CNT-metal interfaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical pulling of airborne absorbing particles and smut spores over a meter-scale distance with negative photophoretic force

We demonstrate optical pulling of single light-absorbing particles and smut spores in air over a meter-scale distance using a single collimated laser beam based on negative photophoretic force. The micron-sized particles are pulled towards the light source at a constant speed of 1–10 cm/s in the optical pulling pipeline while undergoing transverse rotation at 0.2–10 kHz. The pulled particles can be manipulated and precisely positioned on the entrance window with an accuracy of ∼20 μm, and their chemical compositions can be characterized with micro-Raman spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data. Additional capability is included with Ring Pull Coating Analysis (RPCA, also part of the software). Additional images are taken of samples with an outer coating and are used to correlate failure of the coating with strain values measured with DIC.

Beck, Peter↗