Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Radar Waveform Pulse Analysis Measurement System for High-Power GaN Amplifiers

This work presents a measurement system to characterize the pulsed response of high-power GaN amplifiers for use in space-based SAR platforms that require very strict amplitude and phase stability. The measurement system is able to record and analyze data on three different time scales: fast, slow, and long, which allows for greater detail of the mechanisms that impact amplitude and phase stability. The system is fully automated through MATLAB, which offers both instrument control capability and in-situ data processing. To validate this system, a high-power GaN HEMT amplifier operated in saturation was characterized. The fast time results show that variations to the amplitude and phase are correlated to DC supply transients, while long time characteristics are correlated to temperature changes.

high-power amplifier (HPA)↗

Pulsed Lidar Measurements of Atmospheric CO2 Column Absorption and Range During the ASCENDS 2009-2011 Airborne Campaigns

We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS mission and have demonstrated the CO2 and O2 measurements from aircraft. Our technique uses two pulsed lasers allowing simultaneous measurement of a single CO2 absorption line near 1572 nm, O2 extinction in the Oxygen A-band, surface height and backscatter profile. The lasers are stepped in wavelength across the CO2 line and an O2 line doublet during the measurement. The column densities for the CO2 and O2 are estimated from the differential optical depths (DOD) of the scanned absorption lines via the IPDA technique. For the 2009 ASCENDS campaign we flew the CO2 lidar only on a Lear-25 aircraft, and measured the absorption line shapes of the CO2 line using 20 wavelength samples per scan. Measurements were made at stepped altitudes from 3 to 12.6 km over the Lamont OK, central Illinois, North Carolina, and over the Virginia Eastern Shore. Although the received signal energies were weaker than expected for ASCENDS, clear C02 line shapes were observed at all altitudes. Most flights had 5-6 altitude steps with 200-300 seconds of recorded measurements per step. We averaged every 10 seconds of measurements and used a cross-correlation approach to estimate the range to the scattering surface and the echo pulse energy at each wavelength. We then solved for the best-fit CO2 absorption line shape, and calculated the DOD of the fitted CO2 line, and computed its statistics at the various altitude steps. We compared them to CO2 optical depths calculated from spectroscopy based on HITRAN 2008 and the column number densities calculated from the airborne in-situ readings. The 2009 measurements have been analyzed in detail and they were similar on all flights. The results show clear CO2 line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. They showed the expected nearly the linear dependence of DOD vs altitude. The measurements showed -1 ppm random errors for 8-10 km altitudes and -30 sec averaging times. For the 2010 ASCENDS campaigns we flew the CO2 lidar on the NASA DC-8 and added an O2 lidar channel. During July 2010 we made measurements of CO2 and O2 column absorption during longer flights over Railroad Valley NV, the Pacific Ocean and over Lamont OK. CO2 measurements were made with 30 steps/scan, 300 scans/sec and improved line resolution and receiver sensitivity. Analysis of the 2010 CO2 measurements shows the expected -linear change of DOD with altitude. For measurements at altitudes> 6 km the random errors were 0.3 ppm for 80 sec averaging times. For the summer 2011 ASCENDS campaigns we made further improvements to the lidar's CO2 line scan and receiver sensitivity. The seven flights in the 2011 Ascends campaign were flown over a wide variety of surface and cloud conditions in the US, which produced a wide variety of lidar signal conditions. Details of the lidar measurements and their analysis will be described in the presentation.

Abshire, J. B.↗

Validating FENDL-2.1 and FENDL-3.2 with a Suite of LLNL Pulsed Sphere Measurements

This report summarizes simulations of LLNL pulsed-sphere neutron-leakage spectra using FENDL- 3.2, an upcoming version of the Fusion Evaluated Nuclear Data Library, and one of its predecessor libraries, FENDL-2.1. These simulated values are compared to values obtained with the recent U.S. nuclear data library, ENDF/B-VIII.0, and its predecessor, ENDF/B-VII.1 as well as experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Global Backscatter Experiment Airborne Pulsed Lidar Measurements

The Global Backscatter Experiment (GLOBE) was intended to provide data on prevailing values of atmospheric backscatter cross section. The primary intent was predicting the performance of space-borne lidar systems. A second and related goal was to understand the source and characteristics of atmospheric aerosol particles. In this paper the authors give a summary of measurement results with emphasis on the magnitude, structure, characteristics and variability of the observed atmospheric aerosol and cloud scattering. The GLOBE pulsed lidar measurements provide an extensive data set on the magnitude and variability of aerosol and cloud backscatter of the atmosphere. The data defines atmospheric aerosol scattering characteristics and should prove to be an important resource for determination of the performance and design of laser remote sensing instruments.

Spinhirne, James D.↗

Cryogenic goniometer for measurements in pulsed magnetic fields fabricated via additive manufacturing technique

Complex high-precision mechanical devices can be fabricated using 3-dimensional printing technology with the help of computer-aided design. Using 3D stereolithography, we have constructed a cryogenic goniometer for measurements in pulsed magnetic fields of up to 100 T, at temperatures as low as 0.5 K. We review the properties of several materials tested in developing the goniometer and report on its design and performance. The goniometer allows samples to be rotated in situ to a precision of 0.2 deg, so that the field can be applied at many different angles to the samples’ symmetry directions. Following its success, we establish that 3D printing is now a viable technology for pulsed-field and other cryogenic probes.

3D printing↗

Sound Speeds of Solids from Ultrasonic Pulse Receiver Measurements

A common method of determining elastic material properties is utilizing an ultrasonic pulse receiver. This is a non-destructive test (NDT) causing no plastic deformation of the material. It requires a pulse generator, oscilloscope, and two transducers to measure the sound velocity of a material. Both longitudinal and shear sound velocities may be obtained by utilizing the appropriate transducer. Acoustic nondestructive testing methods are often used in manufacturing certification processes and for material defect detection in industry. These methods can also be utilized to directly measure the elastic moduli of a material without damaging the material. Overall, it is a low-cost experiment with minimal preparation, and is easy to use.

36 MATERIALS SCIENCE↗

Position-Sensitive Magnetic Calorimeters for Lynx

We describe the performance of position-sensitive metallic magnetic calorimeter X-ray detectors for potential future astrophysics missions, such as Lynx. The motivation behind this is to achieve a large focal plane area by increasing the number of pixels compared to the number of readout channels (called hydra). The detector consists of a 5×5 array of gold absorbers thermally coupled to a paramagnetic sensor. Since each absorber has a different thermal link to the sensor, it generates a different pulse shape and enables discrimination of pixel position. Recently, we have been successfully able to discriminate 25 averaged pulse shapes by means of rise-time and pulse height. The measured pulse shapes and distribution agree well with the modeling results. The estimated energy resolutions based on the pulse height and noise data we measured are 2.8–3.7 eV for MnKα X-ray photons at 50 mK.

Magnetic calorimeters↗

Design and engineering challenges of a multi-energy hard x-ray camera for long-pulse profile measurements at WEST tokamak

The WEST tokamak has recently been prepared for long pulse operation with a water-cooled full first wall. Heating is provided by radiofrequency systems, including Lower Hybrid Current Drive (LHCD). The Princeton Plasma Physics Laboratory has developed a multi-energy hard x-ray camera for profile measurements at WEST. The camera is based on a new generation of 2D pixel array detectors that allow the energy threshold to be independently set for each pixel. The diagnostic will provide spatial, temporal and energy resolved measurements of the hard x-ray emission from the full plasma cross-section, investigating several physical quantities such as the electron temperature from continuum emission, the fast electron tail density produced by radiofrequency current drive and runaway electrons, as well as characteristic tungsten x-rays due to beam-target emission at the edge. Overall, this work describes the engineering challenges that the WEST long pulse scenario poses for this diagnostic and how the design addresses and solves them. Vacuum, thermal stress and heat transfer calculations are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulsed Lidar Measurements of Atmospheric CO2 Column Absorption in the ASCENDS 2011 Airborne Campaign

We have previously demonstrated an efficient pulsed, wavelength-resolved IPDA lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS mission. Our team participated in the 2010 ASCENDS airborne campaigns we flew airborne version of the CO2 and O2 lidar on the NASA DC-8. The CO2 lidar measures the atmospheric backscatter profiles and shape of the 1572.33 nm absorption line using 250 mW average laser power, 30 wavelength samples per scan and 300 scans per second. Most flights had 5-6 altitude steps to greater than 12 km, and clear CO2 line shapes were observed at all altitudes. Our post-flight analysis estimated the Iidar range and pulse energies at each wavelength every second. We then solved for the best-fit CO2 absorption line shape, and calculated the Differential Optical Depth (DOD) at the line peak. We compared these to CO2 DODs calculated from spectroscopy based on HITRAN 2008 and the conditions from airborne in-situ readings. Analysis of the 2010 measurements over the Pacific Ocean and Lamont OK shows the expected -linear change of the peak DOD with altitude. For measurements at altitudes greater than 6 km the random errors were approximately 0.3 ppm for 80 sec averaging times. After the 2010 flights we improved the airborne lidar's scan uniformity, calibration and receiver sensitivity. Our team participated in the seven ASCENDS science flights during late July and August 2011. These flights were made over a wide variety of surface and cloud conditions near the US, including over the central valley of California, over several mountain ranges, over both broken and solid stratus cloud deck over the Pacific Ocean, snow patches on mountain tops, over thin and broken clouds above the US Southwest and Iowa, and over forests near the WLEF tower in Wisconsin. Analyses show the retrievals of lidar range and CO2 column absorption, as wen as estimates of CO2 mixing ratio worked well when measuring over topography with rapidly changing height and reflectivity, through thin clouds and to stratus cloud tops. For regions where the CO2 concentration was relatively constant, the measured CO2 absorption profile (averaged for 50 sec) matched the predicted profile to better than 1% RMS error for all flight altitudes. For 1 & 10 second averaging, the scatter in the retrievals was limited by signal shot noise (i.e. the sigual photon count). Analysis to date shows the decrease in CO2 due to vegetation when flying easterward over the Great Plains as well as the increase in CO2 concentration in the vicinity ofthe coal-fired power plant in New Mexico. Examples of these and other results will be presented.

Abshire, James B.↗

A fiber-coupled dispersion interferometer for density measurements of pulsed power transmission line electron sheaths on Sandia’s Z machine

A fiber-coupled Dispersion Interferometer (DI) is being developed to measure the electron density of plasmas formed in power flow regions, such as magnetically insulated transmission lines, on Sandia National Laboratories (SNL’s) Z machine [D. B. Sinars et al., Phys. Plasmas 27, 070501 (2020)]. The diagnostic operates using a fiber-coupled 1550 nm CW laser with frequency-doubling to 775 nm. The DI is expected to be capable of line-average density measurements between ∼1013 and 1019 cm−2. Initial testing has been performed on a well-characterized RF lab plasma [A. G. Lynn et al., Rev. Sci. Instrum. 80, 103501 (2009)] at the University of New Mexico to quantify the density resolution lower limits of the DI. Initial testing of the DI has demonstrated line-average electron density measurements within 9% of results acquired via a 94 GHz mm wave interferometer for line densities of ∼1 × 1014 cm−2, despite significant differences in probe beam geometries. The instrument will next be utilized for measurements on a ∼1 MA-scale pulsed power driver {MYKONOS [N. Bennett et al., Phys. Rev. Accel. Beams 22, 120401 (2019)] at SNL} before finally being deployed on SNL’s Z machine. The close electrode spacing (mm scale) on Z requires probe beam sizes of ∼1 mm, which can only be obtained with visible or near infrared optical systems, as opposed to longer wavelength mm wave systems that would normally be chosen for this range of density.

Hines, N. R. (ORCID:0000000315316465)↗

Implementation of a Pulsed-Laser Measurement System in the National Transonic Facility

A remotely-adjustable laser transmission and imaging system has been developed for use in a high-pressure, cryogenic wind tunnel. Implementation in the National Transonic Facility has proven the system suitable for velocity and signal lifetime measurements over a range of operating conditions. The measurement system allows for the delivery of high-powered laser pulses through the outer pressure shell and into the test section interior from a mezzanine where the laser is free from environmental disturbances (such as vibrations and excessive condensation) associated with operation of the wind tunnel. Femtosecond laser electronic excitation tagging (FLEET) was utilized to provide freestream velocity measurements, and first results show typical data that may be obtained using the system herein described.

Reese, Daniel T.↗

Analysis of gas storage and transport in Eagle Ford shale using pressure pulse decay measurements with He, Kr and CO 2

Detailed characterization of gas transport and storage in low-permeability and organic-rich shales is associated with an array of challenges due to the complex morphology of the pore space, representing a broad range of pore sizes, combined with the heterogeneous fabric of the shale matrix. These factors, and their interplay during gas transport and sorption, complicate a) the analysis of shale samples at the laboratory scale (~ up to a ft. In length), and b) the prediction of natural gas production and carbon sequestration potential at larger scales. Here, in this work, tandem experiments with inert (helium – He) and adsorbing (krypton - Kr and carbon dioxide - CO 2 ) gases were performed and analyzed to develop an efficient workflow for characterizing and modeling transport and sorption at the laboratory scale. In particular, pressure pulse-decay (PPD) measurements were conducted on an Eagle Ford shale core sample at room temperature using He, Kr, and CO 2 . PPD measurements with He (a non-sorbing gas) were employed to probe the overall porosity, including natural fractures, microcracks, mesopores, and micropores. A triple-porosity model (TPM) was adopted to interpret the gas transport in the shale sample: The pore space is represented by three interacting continua, including macropores (larger fractures), mesopores (including microcracks), and micropores. To facilitate the application of the TPM, a modified analytical approach is introduced to extract effective transport parameters (in terms of the characteristic time for transport at relevant porosity levels) directly from the PPD measurements with He. To validate the modeling approach, model parameters extracted from two He PPD measurements are demonstrated to provide excellent agreement with a 3rd He PPD measurement performed at a higher pressure. The effective transport parameters, extracted from the He experiments, were subsequently converted for application to the Kr and CO 2 PPD experiments, by accounting for relevant transport modes and differences in fluid properties. Excess adsorption isotherms were extracted from the equilibrium pressures of the Kr and CO 2 PPD experiments using the He pore volume as a baseline. These adsorption isotherms were then integrated into the TPM to predict combined gas transport and sorption for Kr and CO 2 , with transport coefficients translated from the He measurements. The predictions for Kr and CO 2 are demonstrated to be in excellent agreement with the experimental observations. This, in turn, demonstrates that the proposed analytical approach provides for an effective characterization of mass transfer rates in shales, that can be applied directly in a TPM representation of mass transfer and sorption.

58 GEOSCIENCES↗

Pulse shape measurements for neutron/gamma discrimination using the TOFPET2 ASIC

Many highly pixelated organic scintillator detection systems would benefit from independent readout of each scintillator pixel. Recent advances in Silicon Photomultiplier (SiPM) technology makes this goal feasible, however the data acquisition from potentially hundreds or thousands of channels requires a low-cost and compact solution. For pixelated neutron detection with organic scintillators, the capability to distinguish between neutron and gamma interactions using Pulse Shape Discrimination (PSD) is required along with pulse charge and time of arrival. The TOFPET2 ASIC from PETsys Electronics is a 64-channel readout chip providing pulse time and charge integration measurements from SiPMs, and is specifically designed for time-of-flight positron-emission tomography. Using an 8 × 8 array of 6 mm × 6 mm J-series SiPMs from SensL/OnSemi (ArrayJ-60035-64P-PCB), we have studied the energy and PSD performance of the TOFPET2 ASIC using a 4 × 4 array of 6 mm × 6 mm × 30 mm trans -Stilbene crystals from Inrad Optics and a custom SiPM routing board from PETsys Electronics. In conclusion, using a time-over-threshold method, we measure a maximum PSD figure-of-merit of approximately 1.2 at 478 keV (the Compton edge of 662 keV) for a J-series SiPM operating at an over-voltage of 3V.

47 OTHER INSTRUMENTATION↗