Search NASA⌕ Search

SEARCH · Search NASA

Results for “pushbroom”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multibeam 1.4-GHz Pushbroom Microwave Radiometer

Airborne prototype of multiple-beam pushbroom microwave radiometer (PBMR) developed to advance radiometric technology necessary for remote sensing of geophysical parameters. Instrument used in several joint Langley Research Center/United States Department of Agriculture soil-moisture flight experiments in Virginia, Texas, and California. Data from experiments used to modify, develop, and verify algorithms used to predict soil moisture from remote-sensing measurements. Image data useful in study of effects of characters of beams on radiometer imaging data.

Lawrence, Roland W.↗

HYMOSS signal processing for pushbroom spectral imaging

The objective of the Pushbroom Spectral Imaging Program was to develop on-focal plane electronics which compensate for detector array non-uniformities. The approach taken was to implement a simple two point calibration algorithm on focal plane which allows for offset and linear gain correction. The key on focal plane features which made this technique feasible was the use of a high quality transimpedance amplifier (TIA) and an analog-to-digital converter for each detector channel. Gain compensation is accomplished by varying the feedback capacitance of the integrate and dump TIA. Offset correction is performed by storing offsets in a special on focal plane offset register and digitally subtracting the offsets from the readout data during the multiplexing operation. A custom integrated circuit was designed, fabricated, and tested on this program which proved that nonuniformity compensated, analog-to-digital converting circuits may be used to read out infrared detectors. Irvine Sensors Corporation (ISC) successfully demonstrated the following innovative on-focal-plane functions that allow for correction of detector non-uniformities. Most of the circuit functions demonstrated on this program are finding their way onto future IC's because of their impact on reduced downstream processing, increased focal plane performance, simplified focal plane control, reduced number of dewar connections, as well as the noise immunity of a digital interface dewar. The potential commercial applications for this integrated circuit are primarily in imaging systems. These imaging systems may be used for: security monitoring systems, manufacturing process monitoring, robotics, and for spectral imaging when used in analytical instrumentation.

Ludwig, David E.↗

New Method for Calibration for Hyperspectral Pushbroom Imaging Systems

A new, easy-to-implement approach for achieving highly accurate spectral and radiometric calibration of array-based, hyperspectral pushbroom imagers is presented in this paper. The equivalence of the plane of the exit port of an integrating sphere to a Lambertian surface is utilized to provide a field-filling radiance source for the imager. Several different continuous wave lasers of various wavelengths and a quartz-tungsten-halogen lamp internally illuminate the sphere. The imager is positioned to "stare" into the port, and the resultant data cube is analyzed to determine wavelength calibrations, spectral widths of channels, radiometric characteristics, and signal-to-noise ratio, as well as an estimate of signal-to-noise performance in the field. The "smile" (geometric distortion of spectra) of the system can be quickly ascertained using this method. As the price and availability of solid state laser sources improve, this technique could gain wide acceptance.

Ryan, Robert↗

Design, tolerancing and alignment of pushbroom imaging spectrometers for high response uniformity

We present a design and tolerancing approach that permits the achievement of a high degree of spatial and spectral uniformity of response from a pushbroom imaging spectrometer. Such uniformity of response is crucial for the extraction of accurate spectroscopic information from remotely sensed data. The spectrometer system example comprises two independent spectrometer modules covering the 400-2500 nm range, seperated through a dichroic mirror.

imaging spectrometry optical design tolerancing↗

Thermoelectric temperature control system for the pushbroom microwave radiometer (PBMR)

A closed loop thermoelectric temperature control system is developed for stabilizing sensitive RF integrated circuits within a microwave radiometer to an accuracy of + or - 0.1 C over a range of ambient conditions from -20 C to +45 C. The dual mode (heating and cooling) control concept utilizes partial thermal isolation of the RF units from an instrument deck which is thermally controlled by thermoelectric coolers and thin film heaters. The temperature control concept is simulated with a thermal analyzer program (MITAS) which consists of 37 nodes and 61 conductors. A full scale thermal mockup is tested in the laboratory at temperatures of 0 C, 21 C, and 45 C to confirm the validity of the control concept. A flight radiometer and temperature control system is successfully flight tested on the NASA Skyvan aircraft.

Dillon-Townes, L. A.↗

Application of pushbroom altimetry from space using large space antennas

The capabilities of multibeam altimetry are discussed and an interferometric multibeam technique for doing precision altimetry is described. The antenna feed horn arrangement and the resulting footprint lube pattern are illustrated. Plans for a shuttle multibeam altimetry mission are also discussed.

Parsons, C. L.↗

Advanced CID array multispectral pushbroom scanner

An optical imager, called the Scanning Imaging Spectroradiometer (SIS), was built for NASA in the early 1970's. Later, the Solidstate Array Spectroradiometer (SAS) was developed on the basis on a substitution of a Charge Injection Device (CID) array for the vidicon of the SIS. The Advanced Solidstate Array Spectroradiometer (ASAS) represents an improvement of the SAS. ASAS is a solidstate multispectral optical imaging radiometer which is currently the most versatile instrument of its type in the visible part of the spectrum. The instrument is capable of absolute radiometric measurements in all of its 32 bands. ASAS can be easily mounted in small aircraft as well as high altitude craft such as the U-2, taking into account also the possibility of a use in the Space Shuttle. The instrument consists of three separate subsystems. Attention is given to the optics, the detector array, data storage, data retrieval, and system performance.

Stewart, S. E.↗

Auxiliary Sensors For "Pushbroom" Imaging

Proposed subsystem of small auxiliary imaging sensors yields additional data on motion of linear imaging sensor scanned across scene perpendicular to its length. Sensors yield data on components of motion to which inertial, radar, and air-speed detectors insensitive. Additional data on motion enhances geometric fidelity.

Jones, Kenneth L.↗

Remote sensing using solid-state array technology

The paper describes the design features and capabilities of a remote sensor that uses solid-state linear arrays and operates in a 'pushbroom' scan mode to provide the required performance. Pushbroom scanning is a term describing the technique of using the forward motion of a satellite platform to sweep a linear array of detectors oriented perpendicular to the ground track across a scene being imaged. One array is typically used for each spectral channel. Satellite motion provides one direction of scan and electronic sampling of the detectors in the crosstrack dimension provides the orthogonal scan component to form an image. The detector array is sampled at the appropriate rate so that contiguous lines are produced. The performance of a pushbroom system is discussed relative to radiometric sensitivity, detector array geometric fidelity, and radiometric correction. System advantages are precision geometric positioning of the detectors, very high sensitivity and favorable SNR, low power consumption, and no moving optics.

Thompson, L. L.↗

Technical issues in focal plane development for terrestrial resource observations

Performance goals for solid-state detector arrays operating in the pushbroom scan mode for the high-resolution, high-accuracy remote sensing of earth resources from space are discussed and some of the focal plane and system trades involved are identified. Issues in the development of solid-state pushbroom arrays with radiometric calibration to 0.5% precision detector-to-detector over a dynamic range of 1000:1 are considered, with calibration, temporal stability and spectral response conditions noted. Factors influencing the geometric precision of satellite-borne pushbroom scan mode sensors are then examined, including satellite orbit track and attitude errors, and geometric and radiometric correlation between information in the various spectral bands. Approaches to the alignment of linear arrays of thousands of detectors are then discussed that take into account tradeoffs between fabrication and test complexity and ground processing requirements. Continuing science experiments are indicated as necessary to establish tolerances on performance goals.

Thompson, L. L.↗

The Landsat Data Continuity Mission Operational Land Imager: Radiometric Performance

The Operational Land Imager (OLI) is one of two instruments to fly on the Landsat Data Continuity Mission (LDCM), which is scheduled to launch in December 2012 to become the 8th in the series of Landsat satellites. The OLI images in the solar reflective part of the spectrum, with bands similar to bands 1-5, 7 and the panchromatic band on the Landsat-7 ETM+ instrument. In addition, it has a 20 nm bandpass spectral band at 443 nm for coastal and aerosol studies and a 30 nm band at 1375 nm to aid in cirrus cloud detection. Like ETM+, spatial resolution is 30 m in the all but the panchromatic band, which is 15 meters. OLI is a pushbroom radiometer with approximately 6000 detectors per 30 meter band as opposed to the 16 detectors per band on the whiskbroom ETM+. Data are quantized to 12 bits on OLI as opposed to 8 bits on ETM+ to take advantage of the improved signal to noise ratio provided by the pushbroom design. The saturation radiances are higher on OLI than ETM+ to effectively eliminate saturation issues over bright Earth targets. OLI includes dual solar diffusers for on-orbit absolute and relative (detector to detector) radiometric calibration. Additionally, OLI has 3 sets of on-board lamps that illuminate the OLI focal plane through the full optical system, providing additional checks on the OLI's response[l]. OLI has been designed and built by Ball Aerospace & Technology Corp. (BATC) and is currently undergoing testing and calibration in preparation for delivery in Spring 2011. Final pre-launch performance results should be available in time for presentation at the conference. Preliminary results will be presented below. These results are based on the performance of the Engineering Development Unit (EDU) that was radiometrically tested at the integrated instrument level in 2010 and assembly level measurements made on the flight unit. Signal-to-Noise (SNR) performance: One of the advantages of a pushbroom system is the increased dwell time of the detectors allowing for significantly higher SNR than equivalent aperture whiskbroom systems. OLI performance based on the EDU at the "typical" radiance level as specified in the OLI requirements document are about 10 times better than ETM+ performance and 2-3 times better than the requirements for OLI (Table 1).

Markham, Brian↗

Hardware Implementation of Lossless Adaptive Compression of Data From a Hyperspectral Imager

Efficient onboard data compression can reduce the data volume from hyperspectral imagers on NASA and DoD spacecraft in order to return as much imagery as possible through constrained downlink channels. Lossless compression is important for signature extraction, object recognition, and feature classification capabilities. To provide onboard data compression, a hardware implementation of a lossless hyperspectral compression algorithm was developed using a field programmable gate array (FPGA). The underlying algorithm is the Fast Lossless (FL) compression algorithm reported in Fast Lossless Compression of Multispectral- Image Data (NPO-42517), NASA Tech Briefs, Vol. 30, No. 8 (August 2006), p. 26 with the modification reported in Lossless, Multi-Spectral Data Comressor for Improved Compression for Pushbroom-Type Instruments (NPO-45473), NASA Tech Briefs, Vol. 32, No. 7 (July 2008) p. 63, which provides improved compression performance for data from pushbroom-type imagers. An FPGA implementation of the unmodified FL algorithm was previously developed and reported in Fast and Adaptive Lossless Onboard Hyperspectral Data Compression System (NPO-46867), NASA Tech Briefs, Vol. 36, No. 5 (May 2012) p. 42. The essence of the FL algorithm is adaptive linear predictive compression using the sign algorithm for filter adaption. The FL compressor achieves a combination of low complexity and compression effectiveness that exceeds that of stateof- the-art techniques currently in use. The modification changes the predictor structure to tolerate differences in sensitivity of different detector elements, as occurs in pushbroom-type imagers, which are suitable for spacecraft use. The FPGA implementation offers a low-cost, flexible solution compared to traditional ASIC (application specific integrated circuit) and can be integrated as an intellectual property (IP) for part of, e.g., a design that manages the instrument interface. The FPGA implementation was benchmarked on the Xilinx Virtex IV LX25 device, and ported to a Xilinx prototype board. The current implementation has a critical path of 29.5 ns, which dictated a clock speed of 33 MHz. The critical path delay is end-to-end measurement between the uncompressed input data and the output compression data stream. The implementation compresses one sample every clock cycle, which results in a speed of 33 Msample/s. The implementation has a rather low device use of the Xilinx Virtex IV LX25, making the total power consumption of the implementation about 1.27 W.

Keymeulen, Didlier↗