Study of aluminum particle combustion in solid propellant plumes using digital in-line holography and imaging pyrometry

The combustion of molten metals is an important area of study with applications ranging from solid aluminized rocket propellants to fireworks displays. Our work uses digital in-line holography (DIH) to experimentally quantify the three-dimensional position, size, and velocity of aluminum particles during combustion of ammonium perchlorate (AP) based solid-rocket propellants. Additionally, spatially resolved particle temperatures are simultaneously measured using two-color imaging pyrometry. To allow for fast characterization of the properties of tens of thousands of particles, automated data processing routines are proposed. In using these methods, statistics from aluminum particles with diameters ranging from 15 to 900 µm are collected at an ambient pressure of 83 kPa. In the first set of DIH experiments, increasing initial propellant temperature is shown to enhance the agglomeration of nascent aluminum at the burning surface, resulting in ejection of large molten aluminum particles into the exhaust plume. The resulting particle number and volume distributions are quantified. In the second set of simultaneous DIH and pyrometry experiments, particle size and velocity relationships as well as temperature statistics are explored. The average measured temperatures are found to be 2640 ± 282 K, which compares well with previous estimates of the range of particle and gas-phase temperatures. The novel methods proposed here represent new capabilities for simultaneous quantification of the joint size, velocity, and temperature statistics during the combustion of molten metal particles. The proposed techniques are expected to be useful for detailed performance assessment of metalized solid-rocket propellants.

36 MATERIALS SCIENCE↗

Predicting melt pool depth and grain length using multiple signatures from in-situ single camera two-wavelength imaging pyrometry for laser powder bed fusion

In laser powder bed fusion (LPBF), the in-situ process signatures are known to have a direct correlation with the microstructural properties of the solidified melt pool (MP). It is known that the MP cooling and heating rates, and laser processing parameters can critically determine the grain structure and thereby affect the part properties. The objective of this work is to study the feasibility of using in-process, high-speed imaging pyrometry for evaluating the solidified MP properties “below” the surface, such as depth and microstructural properties. To accomplish this, we employ an in-house single camera-based two-wavelength imaging pyrometry (STWIP) system for monitoring the printing of single-scan tracks with Inconel 718 on a commercial LPBF printer (EOS M290). Further, the lab designed STWIP system is a coaxial high-speed (>10,000 fps) imaging system capable of monitoring MP temperature, morphology, and intensity profiles. The temperature measurements from STWIP are emissivity independent. The STWIP measured MP signatures of the printed tracks are correlated with the ex-situ microscopy characterized MP depth and the average grain lengths. From the data analysis, using support vector machine (SVM)-based regression models, we found that the MP temperature signatures are crucial for an accurate prediction of MP depth and the grain length, thus validating the novelty and necessity of the developed in-situ monitoring methods and analysis.

36 MATERIALS SCIENCE↗

2D surface temperature measurement of plasma facing components with modulated active pyrometry

In nuclear fusion devices, such as Tore Supra, the plasma facing components (PFC) are in carbon. Such components are exposed to very high heat flux and the surface temperature measurement is mandatory for the safety of the device and also for efficient plasma scenario development. Besides this measurement is essential to evaluate these heat fluxes for a better knowledge of the physics of plasma-wall interaction, it is also required to monitor the fatigue of PFCs. Infrared system (IR) is used to manage to measure surface temperature in real time. For carbon PFCs, the emissivity is high and known (ε ~ 0.8), therefore the contribution of the reflected flux from environment and collected by the IR cameras can be neglected. However, the future tokamaks such as WEST and ITER will be equipped with PFCs in metal (W and Be/W, respectively) with low and variable emissivities (ε ~ 0.1–0.4). Consequently, the reflected flux will contribute significantly in the collected flux by IR camera. The modulated active pyrometry, using a bicolor camera, proposed in this paper allows a 2D surface temperature measurement independently of the reflected fluxes and the emissivity. Experimental results with Tungsten sample are reported and compared with simultaneous measurement performed with classical pyrometry (monochromatic and bichromatic) with and without reflective flux demonstrating the efficiency of this method for surface temperature measurement independently of the reflected flux and the emissivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pyrometry simulator (pyrosim) for diagnostic design

Signal estimates are crucial to the design of time-resolved pyrometry measurements. These estimates affect fundamental design decisions, including the optical relay (fiber versus open beam), spectral range (visible or infrared), and amplification needs (possibly at the expense of time resolution). The pyrosim program makes such estimates, allowing the collected power, photon flux, and measured signal to be determined in a broad range of pyrometry measurements. Geometrical collection limits can be applied; sample emissivity, transfer efficiency, and detector sensitivity may also be specified, either as constants or functions of wavelength.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of A Multi-Spectral Pyrometry Sensor for High-Speed Transient Surface-Temperature Measurements in Combustion-Relevant Harsh Environments

Accurate and high-speed transient surface-temperature measurements of combustion devices including internal combustion (IC) engines, gas turbines, etc., provide validation targets and boundary conditions for computational fluid dynamics models, and are broadly relevant to technology advancements such as performance improvement and emissions reduction. Development and demonstration of a multi-infrared-channel pyrometry-based optical instrument for high-speed surface-temperature measurement is described. The measurement principle is based on multi-spectral radiation thermometry (MRT) and uses surface thermal radiation at four discrete spectral regions and a corresponding emissivity model to obtain surface temperature via non-linear least squares (NLLS) optimization. Rules of thumb for specifying the spectral regions and considerations to avoid interference with common combustion products are developed; the impact of these along with linear and non-linear MRT analysis are assessed as a function of temperature and signal-to-noise ratio. A multi-start method to determine the MRT-solution global optimum is described and demonstrated. The resulting multi-channel transient pyrometry instrument is described along with practical considerations including optical-alignment drift, matching intra-channel transient response, and solution-confidence indicators. The instrument demonstrated excellent >97% accuracy and >99% 2-sigma precision over the 400–800 °C range, with ~20 µs (50 kHz, equivalent to 0.2 cad at 2000 RPM IC-engine operation) transient response in the bench validation.

47 OTHER INSTRUMENTATION↗

Surface pyrometry in presence of radiation from other sources with application to turbine blade temperature measurement

Surface pyrometry is feasible even when the amount of surface radiation is exceeded by radiation from surrounding sources. To measure and correct for this interfering radiation, several methods that use multiple wavelength pyrometry were compared by an error analysis. For a specific application to turbine blade temperature measurement in a turbofan engine, a two wavelength method was best. Auxiliary measurements at the same wavelengths substantially improve the accuracy of the method.

Buchele, D. R.↗

Report on the multicolor pyrometry session at the Second NASA Non-Contact Temperature-Measurement Workshop

The session met jointly with the other special sessions. Due to time constraints, the concerns of multicolor pyrometry were not addressed in depth. Multicolor pyrometry attempts to determine an object's temperature and emittance as a function of wavelength from simultaneous measurement of the spectral radiance of the object at multiple wavelengths. The main issues are those of the most appropriate model for the wavelength dependence of the emittance, the number of undetermined parameters, and the error in the measured temperature. It has long been known that it is inappropriate to attempt to model the emittance with a functional form that contains as many unknowns as wavelengths. Such attempts will lead to gross errors in the measured temperature. However, more recent work by Hunter and Khan has indicated that emittance can be modeled by a function with many fewer degrees of freedom than sampled wavelengths (e.g., it may be appropriate to use a second order polynomial to fit data from a forty-color pyrometer). In a platform lecture, Khan described algorithms for determination of the parameters by minimization of the errors between the model and the data in a least-squares sense. The first was a linear method and the second was a non-linear method where the emittance could assume any functional form. Both methods were shown to be very sensitive to random noise and non-linearity in the measurement system.

Spjut, R. Erik↗

Multiwavelength pyrometry to correct for reflected radiation

Computer curve fitting is used in multiwavelength pyrometry to measure the temperature of a surface in the presence of reflected radiation by decomposing its radiation spectrum. Computer-simulated spectra (at a surface temperature of 1000 K; in the wavelength region 0.3 to 20 microns; with a reflected radiation-source temperature of 700 to 2500 K; and reflector emissivity from 0.1 to 0.9) were generated and decomposed. This method of pyrometry determined the surface temperatures under these conditions to within 5 percent. The practicability of the method was further demonstrated by the successful analysis of a related problem--decomposition of the real spectrum of an infrared source containing two emitters to determine their temperatures.

Ng, Daniel L. P.↗

High-Speed Imaging Optical Pyrometry for Study of Boron Nitride Nanotube Generation

A high-speed imaging optical pyrometry system is designed for making in-situ measurements of boron temperature during the boron nitride nanotube synthesis process. Spectrometer measurements show molten boron emission to be essentially graybody in nature, lacking spectral emission fine structure over the visible range of the electromagnetic spectrum. Camera calibration experiments are performed and compared with theoretical calculations to quantitatively establish the relationship between observed signal intensity and temperature. The one-color pyrometry technique described herein involves measuring temperature based upon the absolute signal intensity observed through a narrowband spectral filter, while the two-color technique uses the ratio of the signals through two spectrally separated filters. The present study calibrated both the one- and two-color techniques at temperatures between 1,173 K and 1,591 K using a pco.dimax HD CMOS-based camera along with three such filters having transmission peaks near 550 nm, 632.8 nm, and 800 nm.

Inman, Jennifer A.↗

Using pyrometry to identify porosity in additively manufactured structures

A method and apparatus for identifying porosity in a structure made by an additive manufacturing process in which a laser is scanned across layers of material to form the structure. Pyrometry data comprising images of the layers acquired during additive manufacturing of the structure is received. The pyrometry data is used to generate temperature data comprising estimated temperatures of points in the layers in the images of the layers. The temperature data is used to identify shapes fit to high temperature areas in the images of the layers. Conditions of the shapes fit to the high temperature areas in the images of the layers are identified. Outlier shapes are identified in the shapes fit to the high temperature areas in the images of the layers using the conditions of the shapes.

Mitchell, John A.↗

Fourier Transform and Reflective Imaging Pyrometry

A stationary Fourier transform pyrometer was used to record mid-wavelength IR spectra in dynamic shock experiments. The gated-IR camera used with this system was also used to record images of light produced and light reflected from shocked metals in order to constrain the dynamic emissivity and provide temperature estimates. This technique will be referred to as reflective imaging pyrometry.

47 OTHER INSTRUMENTATION↗

Robust two-colour pyrometry uncertainty analysis to acquire spatially-resolved measurements

Two-colour pyrometry (2CP) has been used over several decades to study engine-relevant combustion processes, but results are generally regarded as qualitative or semi-quantitative. In many current 2CP systems, large measurement errors are introduced by parallax because the two measured wavelengths are not from the same line of sight. Here this work presents a spatially-resolved 2CP system with the objective of quantifying and reducing measurement uncertainty. An optical setup that eliminates parallax in 2CP is used together with pixel-by-pixel calibration of the camera sensor to increase measurement accuracy. Primary uncertainty terms are identified, and an error propagation analysis is performed to compute uncertainties in the final results of soot temperature, soot concentration parameter, KL, and soot mass. These methodologies are applied to investigate an auto-igniting fuel spray in a constant pressure flow rig at diesel-like conditions of high ambient pressure and temperature. Results show bias uncertainty of around 200 K (≈10%) for temperature and about 40%–60% for KL. High uncertainty was found to occur on the diffusion flame front where both optical thickness and soot concentrations are small. However, these uncertain measurement zones with relatively low soot concentrations contribute minimally to the total soot mass present in the reacting jet during the temporal evolution of the flame.

42 ENGINEERING↗

Determining Flame Temperature By Broadband Two Color Pyrometry in A Flame Spreading Over A Thin Solid in Microgravity

Fire spread inside a spacecraft is a constant concern in space travel. Understanding how the fire grows and spreads, and how it can potentially be extinguished is critical for planning future missions. The conditions inside a spacecraft can greatly vary from those encountered on earth, including microgravity, low velocity flows, reduced ambient pressure and high oxygen, and thus affecting the combustion processes. In microgravity, the contributions of thermal radiation from gaseous species and soot can play a critical role in the spread of a flame and the problem has not been fully understood yet. The overall objective of this work is to address this by studying the soot temperature of microgravity flames spreading over a thin solid in microgravity. The experiments presented here were performed as part of the NASA project Saffire IV, conducted in orbit on board the Cygnus resupply vehicle before it re-entered the Earth’s atmosphere. The fuel considered is a thin fabric made of cotton and fiberglass (Sibal) exposed to a forced flow of 20 cm/s in a concurrent flow configuration. Reconstruction of the flame temperature fields is extracted from two color broadband emission pyrometry (B2CP) as the flame propagates over the solid fuel. A methodology, relevant assumptions and its applicability to other microgravity experiments are discussed here. The data obtained shows that the technique provides an acceptable average temperature around ~1300 K, which remains relatively constant during the spread with an error value smaller than 117 K. The data presented in this work provides a methodology that could be applied to other microgravity experiments to be performed by NASA. It is expected that the results will provide insight for what is to be expected in different conditions relevant for fire safety in future space facilities.

fire↗

Numerical assessment of uncertainty and dynamic range expansion of multispectral image-based pyrometry

Temperature measurements based on spectral radiation are often limited by prior knowledge of target surface properties and detector sensitivity. Here the present work describes a multispectral pyrometry method for temperature estimation that does not require information on surface emissivity or calibration. Digital camera simulations considering a silicon-based sensor and five bandpass filters are used to create synthetic images of targets. The detector sensitivity is compensated via high dynamic range imaging technique. The effect of natural and detector noise on temperature estimates is assessed via Monte Carlo simulations. Results from a wavelength-independent model (Gray) are compared with those from the Band model (with emissivity varying between constant spectral bands). The effect of detector dynamic range and spectral position of bandpass filters is discussed. Temperatures as low as 520 K are obtained, with an overall uncertainty of the order of 10 K. The proposed method is applicable to temperature measurements using commercial-grade CMOS/CCD cameras.

42 ENGINEERING↗

A novel nuclear pyrometry for the characterization of high-energy bremsstrahlung and electrons produced in relativistic laser-plasma interactions

We present a novel nuclear activation-based method for the investigation of high-energy bremsstrahlung produced by electrons above 7 MeV generated by a high-power laser. The main component is a novel high-density activation target that is a pseudo alloy of several selected isotopes with different photo-disintegration reaction thresholds. The gamma spectrum emitted by the activated targets is used for the reconstruction of the bremsstrahlung spectrum using an analysis method based on Penfold and Leiss. This nuclear activation-based technique allows for the determination of the number of bremsstrahlung photons per energy bin in a wide range energy without any anticipated fit procedures. Furthermore, the analysis method also allows for the determination of the absolute yield, the energy distribution, and the temperature of high-energy electrons at the relativistic laser-plasma interaction region. The pyrometry is sensitive to energies above 7 MeV only, i.e., this diagnostic is insensitive to any low-energy processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature measurements using multicolor pyrometry in thermal radiation heating environments

Temperature measurements are important for thermal-structural experiments in the thermal radiation heating environments such as used for thermal-structural stress analyses. This paper describes the use of multicolor pyrometry for the measurements of diffuse surfaces in thermal radiation environments that eliminates the effects of background radiation reflections and unknown emissivities based on a least-squares algorithm. The near-infrared multicolor pyrometer had a spectral range of 1100–2400 nm, spectrum resolution of 6 nm, maximum sampling frequency of 2 kHz, working distance of 0.6 m to infinity, temperature range of 700–1700 K. The pyrometer wavelength response, nonlinear intensity response, and spectral response were all calibrated. The temperature of a graphite sample irradiated by quartz lamps was then measured during heating and cooling using the least-squares algorithm based on the calibrated irradiation data. The experiments show that higher temperatures and longer wavelengths are more suitable for the thermal measurements in the quartz lamp radiation heating system. This analysis provides a valuable method for temperature measurements of diffuse surfaces in thermal radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hot-spot generation and growth in shocked plastic-bonded explosives studied by optical pyrometry

The aggregate behavior of hot spots in shocked plastic-bonded explosives (PBX) was studied by nanosecond optical pyrometry. The averaged thermal emission spectra from at least 25 tiny (50 μg) explosive charges of a pentaerythritol tetranitrate PBX, at several impact velocities from 1.5 to 4.5 km/s, was used to determine average temperatures and emissivities. Individual spectra were analyzed to determine the distribution of hot spot temperatures in individual charges with unique microstructures. Understanding shocks in tiny charges with different microstructures is needed to understand shocks in large PBX charges which sample many microstructures as they propagate. The initial hot spot density was several percent, and the average initial hot spot temperature of 4000 K was, surprisingly, independent of impact velocity. With underdriven shocks, the initial hot spot temperatures clustered around 4000 K, but with overdriven shocks, there were both hotter and colder hot spots. The initial hot spot density increased quadratically with impact velocity. The generation of hot spots was described by a model with a threshold energy to trigger hot spot formation and a distribution of energetic barriers to hot spot formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.