Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Uncertainty Quantification for Quantitative Imaging Holdup Measurements

In nuclear fuel cycle safeguards, special nuclear material "held up" in pipes, ducts, and glove boxes causes significant uncertainty in material-unaccounted-for estimates. Quantitative imaging is a proposed non-destructive assay technique with potential to estimate the holdup mass more accurately and reliably than current techniques. However, uncertainty analysis for quantitative imaging remains a significant challenge. In this work we demonstrate an analysis approach for data acquired with a fast-neutron coded aperture imager. The work includes a calibrated forward model of the imager. Cross-validation indicates that the forward model predicts the imager data typically within 23%; further improvements are forthcoming. A new algorithm based on the chi-squared goodness-of-fit metric then uses the forward model to calculate a holdup confidence interval. The new algorithm removes geometry approximations that previous methods require, making it a more reliable uncertainty estimator.

holdup measurement↗

Multispectral Thin Film Biosensing and Quantitative Imaging Using 3D Plasmonic Crystals

This work provides plasmonic crystal platforms for quantitative imaging mode biosensing and multispectral immunoassays, establishing and validating both the optical and equilibrium bases for their operation. We investigated the distance-dependent refractive index sensitivity of full 3D plasmonic crystals to thin polymeric films formed using layer by layer (LbL) assembly of polyelectrolytes as a model system. LbL was also used to determine the preferred gold thickness and plasmonic crystal design rules (nanowell diameter and periodicity) for improved thin-film sensitivity, and full 3D finite-difference time-domain (FDTD) calculations were used to quantitatively model and confirm the experimentally observed thin film sensitivities. Here, the integrated multispectral response of the crystals increases approximately linearly with film thickness for values <70 nm, which enables the use of molecular rulers with known thicknesses (such as self-assembled monolayers of alkanethiols on gold) to calibrate these optics for quantitative detection and speciation of surface binding events in a multiplexed imaging format. The utility of these sensors and multispectral analysis for applications in quantitative biosensing was further demonstrated by measuring the equilibrium response curve of an antibody/antigen pair (rabbit antigoat IgG/goat IgG) at increasing antigen concentrations. Fitting the integrated response to a Langmuir isotherm yielded a calculated binding constant on the order of ~10 7 M –1 , which is in agreement with the affinity constants reported in the literature for anti-IgG/IgG binding pairs and provides intrinsic detection limits of ~400 pM for such unamplified assays.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MO-C-12A-01: Quantitative Imaging Initiatives: Why, Who, What, and How?

Over the past decade, there has been an increasing focus on quantitative imaging (QI), which, according to one definition, is “the extraction of quantifiable features from medical images for the assessment of normal or the severity, degree of change, or status of a disease, injury, or chronic condition relative to normal” ( www.rsna.org/QIBA ). To achieve the goals of QI requires the development and standardization of data acquisition, data analysis, and data display techniques, as well as appropriate reporting structures. As such, successful implementation of QI relies heavily on expertise from the fields of medical physics, radiology, statistics, and informatics as well as collaboration from vendors of imaging acquisition, analysis, and reporting systems. When successfully implemented, QI techniques will provide image-derived metrics with known bias and variance that can be validated with anatomically and physiologically relevant measures, including treatment response, and the heterogeneity of that response, and outcome. Such non-invasive measures can then be used effectively in clinical and translational research as well as patient care. In addition to modality-specific QI efforts implemented by individual scientific organizations, national and international organizations, including the NCI, RSNA, FDA, and NIST, appreciating the tremendous potential of QI but also understanding the associated challenges, have become increasingly involved. This symposium session will focus on 1) introducing QI and illustrating why it is important, even though challenging, in both research and clinical applications, and 2) providing overviews of QI efforts from national and international organizations, including the RSNA, NCI, FDA, and NIST. Learning Objectives: Understand the importance and potential of QI in research and clinical applications. Understand key challenges of QI and current barriers to implementation. Understand the current QI efforts of several national and international agencies and organizations, including the FDA, NCI, NIST, and RSNA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mammographic quantitative image analysis and biologic image composition for breast lesion characterization and classification

Purpose: To investigate whether biologic image composition of mammographic lesions can improve upon existing mammographic quantitative image analysis (QIA) in estimating the probability of malignancy. Methods: The study population consisted of 45 breast lesions imaged with dual-energy mammography prior to breast biopsy with final diagnosis resulting in 10 invasive ductal carcinomas, 5 ductal carcinomain situ, 11 fibroadenomas, and 19 other benign diagnoses. Analysis was threefold: (1) The raw low-energy mammographic images were analyzed with an established in-house QIA method, “QIA alone,” (2) the three-compartment breast (3CB) composition measure—derived from the dual-energy mammography—of water, lipid, and protein thickness were assessed, “3CB alone”, and (3) information from QIA and 3CB was combined, “QIA + 3CB.” Analysis was initiated from radiologist-indicated lesion centers and was otherwise fully automated. Steps of the QIA and 3CB methods were lesion segmentation, characterization, and subsequent classification for malignancy in leave-one-case-out cross-validation. Performance assessment included box plots, Bland–Altman plots, and Receiver Operating Characteristic (ROC) analysis. Results: The area under the ROC curve (AUC) for distinguishing between benign and malignant lesions (invasive and DCIS) was 0.81 (standard error 0.07) for the “QIA alone” method, 0.72 (0.07) for “3CB alone” method, and 0.86 (0.04) for “QIA+3CB” combined. The difference in AUC was 0.043 between “QIA + 3CB” and “QIA alone” but failed to reach statistical significance (95% confidence interval [–0.17 to + 0.26]). Conclusions: In this pilot study analyzing the new 3CB imaging modality, knowledge of the composition of breast lesions and their periphery appeared additive in combination with existing mammographic QIA methods for the distinction between different benign and malignant lesion types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative imaging of anion exchange kinetics in halide perovskites

Significance Fundamental understanding of chemical transformation mechanism in solid-state semiconductors can offer guidelines for engineering these materials with various functionalities. Microscopically resolving such transformation process on the single-particle level can provide a direct picture of the dynamics, but has always been challenging due to the deficiencies of characterization techniques and material dimensions. This work presents a unique design on realizing the quantitative imaging of anion exchange reaction kinetics in halide perovskites by taking advantage of their high and tunable photoluminescence and characteristic lattice dynamics, coupled with controllable chemical treatments and optical microscopic techniques. Our study on kinetically visualizing ion exchange behavior in solid-state materials could also inspire mechanistic insights into other phenomena in a broad context of physical science.

2D heterostructures↗

MO-D-213-06: Quantitative Image Quality Metrics Are for Physicists, Not Radiologists: How to Communicate to Your Radiologists Using Their Language

Purpose: A framework for explaining differences in image quality to non-technical audiences in medial imaging is needed. Currently, this task is something that is learned “on the job.” The lack of a formal methodology for communicating optimal acquisition parameters into the clinic effectively mitigates many technological advances. As a community, medical physicists need to be held responsible for not only advancing image science, but also for ensuring its proper use in the clinic. This work outlines a framework that bridges the gap between the results from quantitative image quality metrics like detectability, MTF, and NPS and their effect on specific anatomical structures present in diagnostic imaging tasks. Methods: Specific structures of clinical importance were identified for a body, an extremity, a chest, and a temporal bone protocol. Using these structures, quantitative metrics were used to identify the parameter space that should yield optimal image quality constrained within the confines of clinical logistics and dose considerations. The reading room workflow for presenting the proposed changes for imaging each of these structures is presented. The workflow consists of displaying images for physician review consisting of different combinations of acquisition parameters guided by quantitative metrics. Examples of using detectability index, MTF, NPS, noise and noise non-uniformity are provided. During review, the physician was forced to judge the image quality solely on those features they need for diagnosis, not on the overall “look” of the image. Results: We found that in many cases, use of this framework settled mis-agreements between physicians. Once forced to judge images on the ability to detect specific structures inter reader agreement was obtained. Conclusion: This framework will provide consulting, research/industrial, or in-house physicists with clinically relevant imaging tasks to guide reading room image review. This framework avoids use of the overall “look” or “feel” to dictate acquisition parameter selection. Equipment grants GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Potential Use of {sup 18}F-fluorodeoxyglucose Positron Emission Tomography–Based Quantitative Imaging Features for Guiding Dose Escalation in Stage III Non-Small Cell Lung Cancer

Purpose: To determine whether previously identified quantitative image features (QIFs) based on {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET) (co-occurrence matrix energy and solidity) are able to isolate subgroups of patients who would receive a benefit or detriment from dose escalation in terms of overall survival (OS) or progression-free survival (PFS). Methods and Materials: Subgroups of a previously analyzed 225 patient cohort were generated with the use of 5-percentile increment cutoff values of disease solidity and primary tumor co-occurrence matrix energy. The subgroups were analyzed with a log-rank test to determine whether there was a difference in OS and PFS between patients treated with 60 to 70 Gy and those receiving 74 Gy. Results: In the entire patient cohort, there was no statistical difference in terms of OS or PFS between patients receiving 74 Gy and those receiving 60 to 70 Gy. It was qualitatively observed that as disease solidity and primary co-occurrence matrix energy increased, patients receiving 74 Gy had an improved OS and PFS compared with those receiving 60 to 70 Gy. The opposite trend (detriment of receiving 74 Gy) was also observed regarding low values of disease solidity and primary co-occurrence matrix energy. Conclusions: FDG-PET–based QIFs were found to be capable of isolating subgroups of patients who received a benefit or detriment from dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-G-303-00: Radiomics: Advances in the Use of Quantitative Imaging Used for Predictive Modeling

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

In vivo, label-free, three-dimensional quantitative imaging of liver surface using multi-photon microscopy

Various structural features on the liver surface reflect functional changes in the liver. The visualization of these surface features with molecular specificity is of particular relevance to understanding the physiology and diseases of the liver. Using multi-photon microscopy (MPM), we have developed a label-free, three-dimensional quantitative and sensitive method to visualize various structural features of liver surface in living rat. MPM could quantitatively image the microstructural features of liver surface with respect to the sinuosity of collagen fiber, the elastic fiber structure, the ratio between elastin and collagen, collagen content, and the metabolic state of the hepatocytes that are correlative with the pathophysiologically induced changes in the regions of interest. This study highlights the potential of this technique as a useful tool for pathophysiological studies and possible diagnosis of the liver diseases with further development.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TU-G-303-01: Radiomics: Quantitative Imaging in the Service of Improved Treatment Decision Making

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

Quantitative Imaging with a Mobile Phone Microscope

Use of optical imaging for medical and scientific applications requires accurate quantification of features such as object size, color, and brightness. High pixel density cameras available on modern mobile phones have made photography simple and convenient for consumer applications; however, the camera hardware and software that enables this simplicity can present a barrier to accurate quantification of image data. This issue is exacerbated by automated settings, proprietary image processing algorithms, rapid phone evolution, and the diversity of manufacturers. If mobile phone cameras are to live up to their potential to increase access to healthcare in low-resource settings, limitations of mobile phone–based imaging must be fully understood and addressed with procedures that minimize their effects on image quantification. Here we focus on microscopic optical imaging using a custom mobile phone microscope that is compatible with phones from multiple manufacturers. We demonstrate that quantitative microscopy with micron-scale spatial resolution can be carried out with multiple phones and that image linearity, distortion, and color can be corrected as needed. Using all versions of the iPhone and a selection of Android phones released between 2007 and 2012, we show that phones with greater than 5 MP are capable of nearly diffraction-limited resolution over a broad range of magnifications, including those relevant for single cell imaging. We find that automatic focus, exposure, and color gain standard on mobile phones can degrade image resolution and reduce accuracy of color capture if uncorrected, and we devise procedures to avoid these barriers to quantitative imaging. By accommodating the differences between mobile phone cameras and the scientific cameras, mobile phone microscopes can be reliably used to increase access to quantitative imaging for a variety of medical and scientific applications.

59 BASIC BIOLOGICAL SCIENCES↗

Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs

Purpose: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). Methods: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. Results: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two calibration methods. With wavelet analysis, defective pixels and inter-subpanel flat-fielding artifacts were clearly identified as spikes after thresholding the inversely transformed images. Conclusions: The proposed local NPS (r-square values) showed superior sensitivity to the noise level variations of individual subpanels compared with global quantitative metrics such as MTF, NPS, and DQE. Wavelet analysis was effective in detecting isolated defective pixels and inter-subpanel flat-fielding artifacts. The proposed methods are promising for the early detection of imaging artifacts of EPIDs.

60 APPLIED LIFE SCIENCES↗

Quantitative Imaging of Turbulent Mixing Dynamics in High-Pressure Fuel Injection to Enable Predictive Simulations of Engine Combustion

In this LDRD project, we developed a capability for quantitative high - speed imaging measurements of high - pressure fuel injection dynamics to advance understanding of turbulent mixing in transcritical flows, ignition, and flame stabilization mechanisms, and to provide e ssential validation data for developing predictive tools for engine combustion simulations. Advanced, fuel - efficient engine technologies rely on fuel injection into a high - pressure, high - temperature environment for mixture preparation and com bustion. Howe ver, the dynamics of fuel injection are not well understood and pose significant experimental and modeling challenges. To address the need for quantitative high - speed measurements, we developed a Nd:YAG laser that provides a 5ms burst of pulses at 100 kHz o n a robust mobile platform . Using this laser, we demonstrated s patially and temporally resolved Rayleigh scattering imaging and particle image velocimetry measurements of turbulent mixing in high - pressure gas - phase flows and vaporizing sprays . Quantitativ e interpretation of high - pressure measurements was advanced by reducing and correcting interferences and imaging artifacts.

33 ADVANCED PROPULSION SYSTEMS↗

A quantitative imaging framework for lithium morphology: Linking deposition uniformity to cycle stability in lithium metal batteries

Characterizing the morphology of lithium (Li) is crucial for developing long-lasting lithium metal batteries. It is well established that more uniform Li deposition correlates with better cell performance. Li morphology is often characterized through qualitative analysis of scanning electron microscopy (SEM) images; however, there are no widely accepted metrics to quantitatively describe deposition uniformity. Here, we propose a framework to quantify uniformity through SEM image analysis via the index of dispersion (ID) metric, which is defined and presented in the context of Li metal batteries. We also explore experimental impacts of sampling protocols onIDmeasurements. Our results demonstrate that theIDmetric is highly sensitive to variations in deposition uniformity, including the coexistence and uniformity of multiple morphologies, uniformity within a single morphology, and particle size distribution uniformity. Furthermore, it is demonstrated that uniformity, as measured by theID, can be related to the average potential of Li||Li symmetric cells over cycling. Higher capacity cycling leads to more pronounced changes in bothIDand average cell potential. Local minima/maxima are found consistently in bothIDand average cell potential immediately before cells short-circuit, which we suggest may indicate a collapse of the microstructure prior to failure. We put forward this framework as a more robust approach to quantify Li deposition uniformity, advancing the development of Li metal batteries that are safer and longer lasting.

Science & Technology - Other Topics↗

AI-enabled Lorentz microscopy for quantitative imaging of nanoscale magnetic spin textures

The manipulation and control of nanoscale magnetic spin textures are of rising interest as they are potential foundational units in next-generation computing paradigms. Achieving this requires a quantitative understanding of the spin texture behavior under external stimuli using in situ experiments. Lorentz transmission electron microscopy (LTEM) enables real-space imaging of spin textures at the nanoscale, but quantitative characterization of in situ data is extremely challenging. Here, we present an AI-enabled phase-retrieval method based on integrating a generative deep image prior with an image formation forward model for LTEM. Our approach uses a single out-of-focus image for phase retrieval and achieves significantly higher accuracy and robustness to noise compared to existing methods. Furthermore, our method is capable of isolating sample heterogeneities from magnetic contrast, as shown by application to simulated and experimental data. This approach allows quantitative phase reconstruction of in situ data and can also enable near real-time quantitative magnetic imaging.

36 MATERIALS SCIENCE↗

Quantitative Imaging of Single, Unstained Viruses with Coherent X Rays

We report the recording and reconstruction of x-ray diffraction patterns from single, unstained viruses, for the first time. By separating the diffraction pattern of the virus particles from that of their surroundings, we performed quantitative and high-contrast imaging of a single virion. The structure of the viral capsid inside a virion was visualized. This work opens the door for quantitative x-ray imaging of a broad range of specimens from protein machineries and viruses to cellular organelles. Moreover, our experiment is directly transferable to the use of x-ray free electron lasers, and represents an experimental milestone towards the x-ray imaging of large protein complexes.

60 APPLIED LIFE SCIENCES↗

Automated segmentation of soft X-ray tomography: Native cellular structure with submicron resolution at high-throughput for whole-cell quantitative imaging in yeast

Soft X-ray tomography (SXT) is an invaluable tool for quantitatively analyzing cellular structures at suboptical isotropic resolution. However, it has traditionally depended on manual segmentation, limiting its scalability for large datasets. Here, we leverage a deep learning-based autosegmentation pipeline to segment and label cellular structures in hundreds of cells across three Saccharomyces cerevisiae strains. This task-based pipeline uses manual iterative refinement to improve segmentation accuracy for key structures, including the cell body, nucleus, vacuole, and lipid droplets, enabling high-throughput and precise phenotypic analysis. Using this approach, we quantitatively compared the three-dimensional (3D) whole-cell morphometric characteristics of wild-type, VPH1-GFP, and vac14 strains, uncovering detailed strain-specific cell and organelle size and shape variations. We show the utility of SXT data for precise 3D curvature analysis of entire organelles and cells and detection of fine morphological features using surface meshes. Our approach facilitates comparative analyses with high spatial precision and statistical throughput, uncovering subtle morphological features at the single-cell and population level. This workflow significantly enhances our ability to characterize cell anatomy and supports scalable studies on the mesoscale, with applications in investigating cellular architecture, organelle biology, and genetic research across diverse biological contexts.

Chen, Jianhua [Lawrence Berkeley National Laborato↗

Shotgun Approach for Quantitative Imaging of Phospholipids Using Nanospray Desorption Electrospray Ionization Mass Spectrometry

Mass spectrometry imaging (MSI) has been extensively used for determining spatial distributions of molecules in biological samples, and there is increasing interest in using MSI for quantification. Nanospray desorption electrospray ionization, or nano-DESI, is an ambient MSI technique where a solvent is used for localized extraction of molecules followed by nanoelectrospray ionization. Doping the nano-DESI solvent with carefully selected standards enables online quantification during MSI experiments. In this proof-of-principle study, we demonstrate this quantification approach can be extended to provide shotgun-like quantification of phospholipids in thin brain tissue sections. Specifically, two phosphatidylcholine (PC) standards were added to the nano-DESI solvent for simultaneous imaging and quantification of 22 PC species observed in nano-DESI MSI. Furthermore, by combining the quantitative data obtained in the individual pixels, we demonstrate quantification of these PC species in seven different regions of a rat brain tissue section.

Environmental Molecular Sciences Laboratory↗