Search NASA⌕ Search

SEARCH · Search NASA

Results for “quartz crystal microbalance sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

26 records · Page 2

Quartz Crystal Microbalance (QCM) monitor of contamination for LES-8/9

A Quartz Crystal Microbalance (QCM) was used to monitor condensable contamination during the launching of two Lincoln Laboratory Experimental Satellites--LES-8 and LES-9. The QCM was installed on the dispenser truss and measured contamination by means of a frequency shift of a quartz crystal oscillator. By using a special crystal cut and a second reference quartz crystal, the sensor had extreme sensitivity and remarkable temperature independence. A 1-Hz frequency shift, which corresponds to 3.5 x 10 to the -9th power g/sq cm was resolved by the flight instrumentation.

Lynch, J. T.↗

New Polymer Coatings for Chemically Selective Mass Sensors

There is a current need to develop sensitive and chemically specific sensors for the detection of nitric acid for in-situ measurements in the atmosphere. Polymer coatings have been synthesized and tested for their sensitivity and selectivity to nitric acid. A primary requirement for these polymers is detectability down to the parts per trillion range. The results of studies using these polymers as coatings for quartz crystal microbalances (QCM) and surface acoustic wave (SAW) devices will be presented.

Sims, S. C.↗

Stability Enhancement of Polymeric Sensing Films Using Fillers

Experiments have shown the stability enhancement of polymeric sensing films on mixing the polymer with colloidal filler particles (submicron-sized) of carbon black, silver, titanium dioxide, and fumed silicon dioxide. The polymer films are candidates for potential use as sensing media in micro/nano chemical sensor devices. The need for stability enhancement of polymer sensing films arises because such films have been found to exhibit unpredictable changes in sensing activity over time, which could result in a possible failure of the sensor device. The changes in the physical properties of a polymer sensing film caused by the sorption of a target molecule can be measured by any of several established transduction techniques: electrochemical, optical, calorimetric, or piezoelectric, for example. The transduction technique used in the current polymer stability experiments is based on piezoelectric principles using a quartz-crystal microbalance (QCM). The surface of the QCM is coated with the polymer, and the mass uptake by the polymer film causes a change in the oscillating frequency of the quartz crystal. The polymer used for the current study is ethyl cellulose. The polymer/ polymer composite solutions were prepared in 1,3 dioxolane solvent. The filler concentration was fixed at 10 weight percent for the composites. The polymer or polymer composite solutions were cast on the quartz crystal having a fundamental frequency of about 6 MHz. The coated crystal was subjected to a multistage drying process to remove all measurable traces of the solvent. In each experiment, the frequency of oscillation was measured while the QCM was exposed to clean, dry, flowing air for about 30 minutes, then to air containing a known concentration of isopropanol for about 30 minutes, then again to clean dry air for about 30 minutes, and so forth. This cycle of measurements for varying isopropanol concentrations was repeated at intervals for several months. The figure depicts some of the sensing film stability results for ethyl cellulose polymer, ethyl cellulose-carbon black, and ethyl cellulose-silicon dioxide composite systems. An ethyl cellulose film exhibited a marked decline in response in the first few months of study and settled to a steady average response after about four months. However, response varied widely around the average response for ethyl cellulose film. In contrast, ethyl cellulose- carbon black and ethyl cellulose-silicon dioxide composites also declined in the early months, but showed more repeatable sensing film activity after the initial decline. Similar trends were observed in experiments for ethyl cellulose-titanium dioxide and ethyl cellulose-silver composites.

Lin, Brian↗

Structural Analysis of the QCM Aboard the ER-2

As a result of recent supersonic transport (SST) studies on the effect they may have on the atmosphere, several experiments have been proposed to capture and evaluate samples of the stratosphere where SST's travel. One means to achieve this is to utilize the quartz crystal microbalance (QCM) installed aboard the ER-2, formerly the U-2 reconnaissance aircraft. The QCM is a cascade impactor designed to perform in-situ, real-time measurements of aerosols and chemical vapors at an altitude of 60,000 - 70,000 feet. The ER-2 is primarily used by NASA for Earth resources to test new sensor systems before they are placed aboard satellites. One of the main reasons the ER-2 is used for this flight experiment is its capability to fly approximately twelve miles above sea level (can reach an altitude of 78,000 feet). Because the ER-2 operates at such a high altitude, it is of special interest to scientists interested in space exploration or supersonic aircraft. Some of the experiments are designed to extract data from the atmosphere around the ER-2. For the current flight experiment, the QCM is housed in a frame that is connected to an outer pod that is attached to the fuselage of the ER-2. Due to the location of the QCM within the housing frame and the location of the pod on the ER-2, the pod and its contents are subject to structural loads. In addition to structural loads, structural vibrations are also of importance because the QCM is a frequency induced instrument. Therefore, a structural analysis of the instrument within the frame is imperative to determine if resonance and/or undesirable deformations occur.

Jones, Phyllis D.↗

Structural Loading on the QCM/SAW Instrument Aboard the ER-2 Used for Atmospheric Testing

Several experiments have been proposed to capture and evaluate samples of the atmosphere where SST's travel. One means to achieve this is to utilize the quartz crystal microbalance (QCM) / surface acoustical wave (SAW) instrument installed aboard the ER-2, formerly the U-2 reconnaissance aircraft. The QCM is a cascade impactor designed to perform in-situ, real-time measurements of aerosols and chemical vapors at an altitude of 60,000-70,000 feet. The primary use of the ER-2 is by NASA for Earth resources to test new sensor systems before being placed aboard satellites. One of the main reasons the ER-2 is used for this flight experiment is its capability to fly approximately twelve miles above the sea level (can reach an altitude of 78,000 feet). Because the ER-2 operates at such a high altitude, it is of special interest to scientists interested in space exploration or supersonic aircraft. The purpose of some of the experiments is to extinct data from the atmosphere around the ER-2. For the current CSTEA flight experiment, the housing of the QCM is in a frame that connects to an outer pod that attaches to the fuselage of the ER-2. Due to the location of the QCM within the housing frame and the location of the pod on the ER-2, the pod and its contents are subject to structural loads. In addition to structural loads, structural vibrations are also of importance because the QCM output data is based on the determination of beat frequencies between a pair of oscillators (one coated, the second uncoated, according to the chemical reaction being monitored). A structural analysis of this system can indicate whether potential resonances may exist between the (higher) structural modal frequencies and the beat frequencies. In addition undesirable deformations may result due to maximum expected static or dynamic loads during typical flight conditions. If the deformations are excessive they may adversely affect the accuracy the instrumentation output.

Bainum, Peter M.↗

Plume mass flow and optical damage distributions for an MMH/N2O4 RCS thruster

The data obtained from two recent experiments conducted in a continuing series of experiments at the Lewis Research Center into the contamination characteristics of a 5-pound thrust MMH/N2O4 engine are presented. The primary objectives of these experiments were to establish the angular distribution of condensible exhaust products within the plume and the corresponding optical damage angular distribution of transmitting optical elements attributable to this contaminant. The plume mass flow distribution was measured by five quartz crystal microbalances (QCM's) located at the engine axis evaluation. The fifth QCM was located above the engine and 15 deg behind the nozzle exit plane. The optical damage was determined by ex-situ transmittance measurements for the wavelength range from 0.2 to 0.6 microns on 2.54 cm diameter fused silica discs also located at engine centerline elevation. Both the mass deposition and optical damage angular distributions followed the expected trend of decreasing deposition and damage as the angle between sensor or sample and the nozzle axis increased. A simple plume gas flow equation predicted the deposition distribution reasonably well for angles of up to 55 degrees. The optical damage measurements also indicated significant effects at large angles.

Spisz, E. W.↗

SAGE III ISS Contamination Monitoring Package: Observations in Orbit

The Stratospheric Aerosol and Gas Experiment III (SAGE III) telescope and instrument assembly employ the methods of solar occultation and lunar occultation to retrieve near-global vertical profiles of atmospheric ozone, water vapor, nitrogen dioxide, aerosol extinctions, and other gaseous species and atmospheric state parameters. The SAGE III grating spectrometer measures light within the spectral range of 280 nm to 1037 nm at approximately 1 nm resolution, but retrievals in the Ultraviolet (UV) are particularly sensitive to contamination of the optical train. Therefore, a contamination door that contains a quartz optical window can be closed over the telescope aperture during periods of enhanced external contaminant flux. This optically transparent window permits continued science event acquisition at an acceptably diminished signal-to-noise ratio, which is expected to decline with ongoing accretion of contaminant material. To date, this impact has been short term, and science quality through the window returns to baseline performance after a contamination source is removed and spontaneous desorption removes material from the low-affinity quartz surface. Two Contamination Monitoring Packages (CMPs) consisting of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) from QCM Research provide characterization and redundant monitoring of contaminant deposition from the 2π steradian solid angle on the payload side of the Expedite the Processing of Experiments to the Space Station (ExPRESS) Payload Adapter. CMP data are closely examined by the SAGE III team to determine when the contamination door should remain closed during science events and in what direction the instrument assembly scan head should stow when not acquiring science measurements. Additionally, should the CMPs indicate an unacceptable accretion rate, the ight computer will close the contamination door as part of the automatic fault detection system. Along with spectrometer measurements of the quartz window's transmission, the payload CMPs enable auditing of the mission contamination budget. The process of Thermogravimetric Analysis (TGA) can be used to help identify chemical constituents accreted on the CMP sensors. To be presented here along with an explanation of the CMP systems are the first two and a half years of observations of the contaminant deposition environment around the payload in quiescence and during special events like docking vehicles.

Tyler T Dawson↗

SAGE III/ISS Contamination Monitoring Package: Observations in Orbit

The Stratospheric Aerosol and Gas Experiment III (SAGE III) telescope and instrument assembly employ the methods of solar occultation and lunar occultation to retrieve near-global vertical profiles of atmospheric ozone, water vapor, nitrogen dioxide, aerosol extinctions, and other gaseous species and atmospheric state parameters. The SAGE III grating spectrometer measures light within the spectral range of 280 nm to 1037 nm at approximately 1 nm resolution, but retrievals in the Ultraviolet (UV) are particularly sensitive to contamination of the optical train. Therefore, a contamination door that contains a quartz optical window can be closed over the telescope aperture during periods of enhanced external contaminant flux. This optically transparent window permits continued science event acquisition at an acceptably diminished signal-to-noise ratio, which is expected to decline with ongoing accretion of contaminant material. To date, this impact has been short term, and science quality through the window returns to baseline performance after a contamination source is removed and spontaneous desorption removes material from the low-affinity quartz surface. Two Contamination Monitoring Packages (CMPs) consisting of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) from QCM Research provide characterization and redundant monitoring of contaminant deposition from the 2pi steradian solid angle on the payload side of the Expedite the Processing of Experiments to the Space Station (ExPRESS) Payload Adapter. CMP data are closely examined by the SAGE III team to determine when the contamination door should remain closed during science events and in what direction the instrument assembly scan head should stow when not acquiring science measurements. Additionally, should the CMPs indicate an unacceptable accretion rate, the flight computer will close the contamination door as part of the automatic fault detection system. Along with spectrometer measurements of the quartz window's transmission, the payload CMPs enable auditing of the mission contamination budget. The process of Thermogravimetric Analysis (TGA) can be used to help identify chemical constituents accreted on the CMP sensors. To be presented here along with an explanation of the CMP systems are the first two and a half years of observations of the contaminant deposition environment around the payload in quiescence and during special events like docking vehicles.

Tyler T Dawson↗