Analysis of an existing spent fuel pool storage rack using current practices and updated depletion bias and uncertainty values - 14458

In accordance with NRC Information Notice 2011-03: Nonconservative Criticality Safety Analysis for Fuel Storage, a US nuclear power plant reviewed their analysis of record (AOR) for possible nonconservative technical specifications related to the criticality safety of fuel storage. During this review, it was determined that some legacy fuel assemblies did not meet all the assumptions of the AOR, but did meet the plant Technical Specifications. The plant entered into an Operability Evaluation in order to evaluate the moderator temperature and boron concentration assumptions used in the AOR, as well as evaluate the impact of including additional biases and depletion uncertainties for the non-borated case. As this study was part of a response to the NRC Information Notice, a full assessment was not conducted. A re-analysis of the spent fuel rack in accordance with current practices was performed. This analysis used the bounding core conditions, and included all biases and depletion uncertainties. The results challenged the 10CFR50.68(b) requirement that 'the k-effective must remain below 1.0 (subcritical), at a 95 percent probability, 95 percent confidence level, if flooded with un-borated water'. Credits for additional reactivity offsets were then analyzed. Previous assumptions for the measurement uncertainty were evaluated and subsequently reduced. New values for the depletion bias and uncertainty were applied. More detailed, realistic modeling was used to remove conservatisms. The results showed that the storage racks met the 10CFR50.68(b) criteria for the un-borated case. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AN INTERNET RACK MONITOR-CONTROLLER FOR APS LINAC RF ELECTRONICS UPGRADE

To support the research and development in APS LINAC area, the existing LINAC rf control performance needs to be much improved, and thus an upgrade of the legacy LINAC rf electronics becomes necessary. The proposed upgrade plan centers on the concept of using a modern, network-attached, rackmount digital electronics platform –Internet Rack Monitor-Controller (or IRMC) to achieve the goal of modernizing the rf electronics at a lower cost. The system model of the envisioned IRMC is basically a 3-tier stack with a high-performance DSP in the mid-layer to perform the core tasks of real-time rf data processing and controls. The Digital Front-End (DFE) attachment layer at bottom bridges the applicationspecific rf front-ends to the DSP. A network communication gateway, together with an embedded event receiver (EVR) in the top layer merges the Internet Rack MonitorController node into the networks of the accelerator controls infrastructure. Although the concept is very much in trend with today’s Internet-of-Things (IoT), this implementation has actually been used in the accelerators for over two decades.

Ma, Hengjie↗

Toughening mechanism of inter-critical heat-affected zone in a 690 MPa grade rack plate steel

Highlights: • Relationship between toughness and microstructure was confirmed. • The toughness of ICHAZ is higher than that of FGHAZ. • Fine bainitic microstructure in ICHAZ plays an important role on improving toughness. • The homogeneous distribution of dislocation and local strain facilitate the plastic deformation prior fracture. - Abstract: The inter-critical heat-affected zone (ICHAZ) and fine grain heat-affected zone (FGHAZ) of a 690 MPa grade rack plate steel were simulated by Gleeble3500 simulator. The toughening mechanism of ICHAZ was clarified by analyzing microstructural characteristics and instrumental Charpy impact tests. The study showed that the ICHAZ had higher toughness than FGHAZ. And the microstructure in FGHAZ was martensite, while bainitic microstructure was obtained in ICHAZ. Both the prior austenite grain size and effective grain size of ICHAZ were smaller than that of FGHAZ, which played an important role in improving the toughness of ICHAZ. It was found that the extensive plastic deformation prior fracture in ICHAZ could consume large energy during crack initiation and propagation. The large plastic deformation capacity of ICHAZ was related to the large fraction of large-angle boundaries and low dislocation density, as well as the homogeneous distribution of local strain and geometrically necessary dislocations.

36 MATERIALS SCIENCE↗

NREL Energy Performance Testing of Asetek's RackCDU System on a Single Rack of Twin Blade Servers: Cooperative Research and Development Final Report, CRADA Number CRD-13-518

The project will entail Asetek retrofitting 1 - 2 compute racks of servers at the National Renewable Energy Laboratory (NREL) to test and validate RackCDU's cooling performance and long-term reliability. The project will also entail measuring and reporting energy savings under a real workload by comparing total power input to the system vs. total heat removed by liquid and air. Direct measurements will be made to compare and contrast energy consumption and performance both before and after RackCDU installation. The scope of this project is strictly demonstration and feedback on the system. No development work will be performed under this CRADA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Transformational Natural Gas Fueled Dynamic SOFC for Data Center in-Rack Power (Final Technical Report)

Data centers consume 250TWh or 1% of global electricity use in 2019. This electricity demand is expected to grow exponentially in the future. The current data center power supply relies on electric grids with diesel engines and batteries as backup; the latter is critically important because a sudden loss of power could erase crucial data, causing catastrophic economic loss. However, such a double protection architecture is costly, inefficient and polluting. In search for better in-rack power system, fuel-cell based generators have recently emerged as a promising alternative to diesel engines and batteries because of its potential to be more cost-effective, more efficient and less polluting. Among many types of fuel cells, solid oxide fuel cells stand out to be a front runner because of their ability to directly operate on natural gas that has an existing infrastructure. However, there are several critical challenges facing SOFC generators to meet the rigorous power requirements of data centers: high cost, poor reliability and more importantly, slow response to the datacenters’ dynamic load change. The unexpected overload conditions in data centers can cause fuel starvation; the latter can initiate microcracks in the anode structure, thus jeopardizing the lifetime of the SOFC generator. The current efforts to increase transient power capabilities of traditional SOFCs and therefore protect SOFC stacks from internal damage during transient loading, rely primarily upon mathematical algorithms. One of the challenges to these control methodologies is the physical limitations of the fuel delivery system such as slow response of mass flow controllers to fast power demand.

30 DIRECT ENERGY CONVERSION↗

Equipment Qualification Report Environmental Qualification of GNB Absolyte Valve Regulated Lead Acid (VRLA) 1600 Ah100G33 Battery Rack Assembly (24590-QL-POA-EDB0-00001-11-00002_00A)

Greenberry Environmental Qualification Report 550001.001-35.0.5 provides basis for assignment of qualified life for: GNB Absolyte Valve Regulated Lead Acid (VRLA) 1600 Ah 100G33 Battery Rack Assembly in accordance with the requirements specified 24590-WTP-3PS-G000-T0015 (Rev 2) and Environmental Qualification Plan 550001.001-35.0.1 (Rev. 3). The equipment qualification basis represents the most conservative capability of the equipment. The analysis performed for the qualification is not less conservative than the bounding environmental conditions detailed in contract documents issued to Greenberry in contract 24509-QL-POA-EDB0-00001 Rev.0. The qualified life of 10 years has been established based upon an end-condition objective of the equipment condition indicators that correlate to the ability of equipment to perform its safety function. The VRLA Battery Cell Assembly was aged by 10 years (minimum) in accordance with conditions specified by Bechtel Equipment Qualification Datasheet 24590-LAW-EUQ-UPE 00003 Rev. 3 and the process conditions specified by the Instrument Data Sheet 24590-LAW EUD-UPE-00009 Rev. 2. Greenberry Industrial has contracted with GNB Industrial Battery Co located at 4115 S Zero St, Fort Smith, AR 72908 to perform age conditioning, monitoring, and capacity testing in accordance with Environmental Qualification Plan 550001.001-35.0.1 Rev. 1. The required process at the stated conditions set by the parameters established by the plan were completed satisfactorily. The details of the of the test process observed by Greenberry is detailed in the attached Seismic Test Log 550001.001-7.0.3, including examples of the objective evidence collected during the qualification process.

54 ENVIRONMENTAL SCIENCES↗

Challenges for Megawatt-Scale Artificial Intelligence Rack Infrastructure

As artificial intelligence (AI) computing densities continue to increase, industry is pursuing megawatt-scale rack architectures that require tightly coordinated advances in electrical power delivery, thermal management, operations, and infrastructure integration. This document summarizes the primary technical challenges for achieving this target.

Nawaz, Kashif [ORNL] (ORCID:0000000251612491)↗

Examination of an Electrified Bar Rack Fish Guidance Device for Hydropower Turbines

The potential of hydropower turbines to cause injury or mortality to fish is a concern. To reduce this risk, engineers have begun to develop a conically arranged, cantilevered electrified bar rack (Center Sender). This device is proposed to be mounted within the intake of a turbine, guiding downstream-passing fish towards the center of the turbine where blade velocities are lower and blades are thicker, likely reducing the potential for fish to be injured. A simplified version was installed in a flume for testing with Rainbow trout (Oncorhynchus mykiss) while examining several parameters such as electrification, bar spacing, bar angle, and water velocity. The most effective settings were observed to be a water velocity of 1.0 m s -1 with all bars installed at an angle of 40° with electrification on. Other combinations were still effective but had varying results. A minimal proportion (2.3%) of fish passed at lower velocities with bars electrified and mounted at 20°, suggesting that while it functions well as a guidance device in high-velocity conditions, it performs better as a barrier at lower velocities. The study suggests that the Center Sender has promising potential for reducing the harmful effects of hydropower turbines on fish populations by guiding them away from stressors. Further research is needed, but current results encourage its potential use in hydropower operations.

13 HYDRO ENERGY↗

Whisper Sensitivity Study of the NMIS ATR Fuel Storage Racks

A sensitivity study was performed on the NMIS ATR fuel storage racks as part of the CSE to implement the boron-carbide aluminum composite shelves. Whisper was used as part of this study to find applicable benchmarks for validation purposes. It was found that Whisper is very useful in finding benchmarks for the most sensitive isotopes in a problem but can be used to search for sensitivities related to specific isotopes. Whisper gave confidence in the NMIS validation and helped the author learn details about the physics of the problem as well.

99 GENERAL AND MISCELLANEOUS↗

Spent fuel storage rack

A system for storing nuclear fuel assemblies includes a plurality of cells housed within a support structure. A first cell may house a first fuel assembly and a second cell may house a second fuel assembly. A plurality of compartments separate the plurality of cells and provide passageways for coolant entering a bottom end of the support structure to remove heat from the nuclear fuel assemblies. A first perforation transfers coolant between the first cell and one or more of the compartments, and a second perforation transfers coolant between the second cell and the one or more compartments. At least a portion of the coolant entering the bottom end of the support structure is transferred between the plurality of cells and the plurality of compartments. Two or more fuel storage racks may be stacked together in alternating fuel patterns to facilitate cooling the fuel assemblies with liquid or air.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Blue Rock CropSpanPV - Low Cost Racking for Agricultural Solar Photovoltaics

In this work, a total of four solar panel layouts, applied to Agrivoltaics, are investigated. This study presents two hypotheses: 1. Prefabrication - Lower total cost can be achieved by constructing a pre-assembled, pre-wired solar array in a factory, with automation, then rapidly deploying it in the field. 2. Tension Structures - Using tension structures in a way to suspend an overhead solar array also reduces costs when compared to conventional support methods. Designs are presented for frames to hold the panels. Configurations are advanced to connect the frames into arrays. Supports and foundations to hold the arrays in the desired layout are calculated, selected and presented. Cost models are prepared for the four layouts, which include definition of the business enterprise, the manufacturing operation, and the required facility for production at scale. Cost models include, detail material and task/labor take-offs for both manufacturing and installation. Comparisons with conventional system adapted to Agrivoltaics reveal that the two hypotheses do not hold true. A prefabricated array requires additional material that is not needed in the base system and the cost of this additional material is not outweighed by the cost savings of reduced field installation. The cost of wire rope for a tension structure does result in an economy of material, however, the cost of end connections and tensioning devices adds significantly to the cost of the overall tension structure. Foundation loads with tension structures, especially the large wind uplift seen with a fixed tilt solar array, impose significant constraints and high costs. The following conclusions are recommended for further consideration: 1. Best Case Agrivoltaic Configuration - The best value/lowest cost configuration for agrivoltaics is the installation of solar panels mounted on a single axis tracker in either a 2-in-portrait or 2-in landscape arrangement. This is useful for grazing lands and for staple crops which require high light levels. These applications represent the vast majority of the potential agrivoltaic market. Important elements in this configuration are the specific geometric layout coordinated with the various field operations and a control system linked between the farm equipment and single axis tracker. The control system is to monitor location and orientation, then actively tilt the solar panels or brake the field equipment to provide clearance and avoid collisions. 2. Long Span Applications - The use of tension structures for an overhead fixed tilt array is beneficial where long spans are a necessity, especially where the base support in the project location has consolidated rock near the surface or some other solid structure. One application is spanning wide irrigation canals. Another may be as an installation at the top deck of parking structures. 3. Direct Ground Mount Configuration – Having skids at the base of a pre-fabricated array that extend when the array is deployed, could be a successful design. This could be a useful strategy for dense, flat, ground-mount configurations like that employed by a couple of successful commercial operations (5G Maverick and Erthos). Arrays would be orientated north and south, deployed very low on prepared grade. Arrays would be aligned closely next to each other and anchored with small ground screws or simply with ballast. This same product arrangement could be very useful for rapid deployment and set-up of solar arrays for temporary deployments, disaster response and the military operations

14 SOLAR ENERGY↗

AMPP Division Rack Cards [Posters/Cards]

The Actinide Material Processing and Power (AMPP) Division supports plutonium 238 science and manufacturing for NASA exploration, Defense Programs, Advanced Recovery and Integrated Extraction System (ARIES) for nuclear non-proliferation, Materials Recovery & Recycle to enable the future of our operations, and americium production to support well logging for the United States.

99 GENERAL AND MISCELLANEOUS↗