At least 37 records · Page 2

Experiments on the ground vortex formed by an impinging jet in cross flow

An inclined jet impinging on the ground creates a wall flow that spreads radially from the point of impingement. If a cross-flow is introduced, the upstream component of the wall flow will separate from the ground and create what has been termed the 'ground vortex.' The ground vortex has been shown to have a significant impact on aircraft aerodynamics and is one of the major contributors to hot gas ingestion. The paper discusses a recent study which included a generic wing-body configuration for assessing the impact of the ground vortex on configuration aerodynamics. Wind tunnel tests using fixed ground boards, moving ground belts, and moving model tests are discussed. The emphasis of the data is macroscopic, i.e. forward location of the vortex, effects of ground height, etc.

Blake, William B.↗

Dilution Jet Behavior in the Turn Section of a Reverse Flow Combuster

Measurements of the temperature field produced by a single jet and a row of dilution jets issued into a reverse flow combustor are presented. The temperature measurements are presented in the form of consecutive normalized temperature profiles, and jet trajectories. Single jet trajectories were swept toward the inner wall of the turn, whether injection was from the inner or outer wall. This behavior is explained by the radially inward velocity component necessary to support irrotational flow through the turn. Comparison between experimental results and model calculations showed poor agreement due to the model's not including the radial velocity component. A widely spaced row of jets produced trajectories similar to single jets at similar test conditions, but as spacing ratio was reduced, penetration was reduced to the point where the dilution jet flow attached to the wall.

Riddlebaugh, S. M.↗

Dilution jet behavior in the turn section of a reverse flow combustor

Measurements of the temperature field produced by a single jet and a row of dilution jets issued into a reverse flow combustor are presented. The temperature measurements are presented in the form of consecutive normalized temperature profiles, and jet trajectories. Single jet trajectories were swept toward the inner wall of the turn, whether injection was from the inner or outer wall. This behavior is explained by the radially inward velocity component necessary to support irrotational flow through the turn. Comparison between experimental results and model calculations showed poor agreement due to the model's not including the radial velocity component. A widely spaced row of jets produced trajectories similar to single jets at similar test conditions, but as spacing ratio was reduced, penetration was reduced to the point where the dilution jet flow attached to the wall.

Riddlebaugh, S. M.↗

The aerodynamics of circulation control

Two dimensional subsonic wind tunnel tests were conducted on a 20% thickness: chord ratio circulation controlled elliptic aerofoil section equipped with forward and reverse blowing slots. Overall performance measurements were made over a range of trailing edge blowing momentum coefficients from 0 to 0.04; some included the effect of leading edge blowing. A detailed investigation of the trailing edge wall jet, using split film probes, hot wire probes and total head tubes, provided measurements of mean velocity components, Reynolds normal and shear stresses, and radial static pressure. The closure of the two dimensional angular momentum and continuity equations was examined using the measured data, with and without correction, and the difficulty of obtaining a satisfactory solution illustrated. Suggestions regarding the nature of the flow field which should aid the understanding of Coanda effect and the theoretical solution of highly curved wall jet flows are presented.

Wood, N. J.↗

Mixing of multiple jets with a confined subsonic crossflow. Summary of NASA-supported experiments and modeling

Experimental and computational results on the mixing of single, double, and opposed rows of jets with an isothermal or variable temperature mainstream in a confined subsonic crossflow are summarized. The studies were performed to investigate flow and geometric variations typical of the complex 3-D flowfield in the dilution zone of combustion chambers in gas turbine engines. The principal observations from the experiments were that the momentum-flux ratio was the most significant flow variable, and that temperature distributions were similar (independent of orifice diameter) when the orifice spacing and the square-root of the momentum-flux ratio were inversely proportional. The experiments and empirical model for the mixing of a single row of jets from round holes were extended to include several variations typical of gas turbine combustors. Combinations of flow and geometry that gave optimum mixing were identified from the experimental results. Based on results of calculations made with a 3-D numerical model, the empirical model was further extended to model the effects of curvature and convergence. The principle conclusions from this study were that the orifice spacing and momentum-flux relationships were the same as observed previously in a straight duct, but the jet structure was significantly different for jets injected from the inner wall wall of a turn than for those injected from the outer wall. Also, curvature in the axial direction caused a drift of the jet trajectories toward the inner wall, but the mixing in a turning and converging channel did not seem to be inhibited by the convergence, independent of whether the convergence was radial or circumferential. The calculated jet penetration and mixing in an annulus were similar to those in a rectangular duct when the orifice spacing was specified at the radius dividing the annulus into equal areas.

Holdeman, James D.↗

Validation of the ERO2.0 code using W7-X and JET experiments and predictions for ITER operation

Abstract The paper provides an overview of recent modelling of global material erosion and deposition in the fusion devices Wendelstein 7-X (W7-X), JET and ITER using the Monte-Carlo code ERO2.0. For validating the modelling tool in a three-dimensional environment, W7-X simulations are performed to describe carbon erosion from the graphite test divertor units, which were equipped in operational phase OP 1.2 and analysed post-mortem. Synthetic spectroscopy of carbon line emission is compared with experimental results from the divertor spectrometer measurement system, showing a good agreement in the e-folding lengths in the radial intensity profiles of carbon. In the case of metallic wall materials, earlier modelling of the Be/W environment in JET and ITER is revisited and extended with an updated set of sputtering and reflection data, as well as including the mixing model for describing the Be/W dynamics in the divertor. Motivated by recent H/D/T isotope experiments in JET, limited and diverted configuration pulses are modelled, showing the expected trend of both Be and W erosion increasing with isotope mass. For the JET diverted configuration pulses, it is shown that Be migrates predominantly to the upper part of the inner divertor where it initially leads to strong W erosion. With longer exposure time, the growth of a Be deposited layer leads to a reduction of W erosion in that region. A similar trend is observed in simulations of the ITER baseline Q = 10 scenario, however with a more symmetric Be migration pattern leading to deposition also on the outer divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical analysis of base flowfield at high altitude for a four-engine clustered nozzle configuration

The objective of this study is to benchmark a four-engine clustered nozzle base flowfield with a computational fluid dynamics (CFD) model. The CFD model is a pressure based, viscous flow formulation. An adaptive upwind scheme is employed for the spatial discretization. The upwind scheme is based on second and fourth order central differencing with adaptive artificial dissipation. Qualitative base flow features such as the reverse jet, wall jet, recompression shock, and plume-plume impingement have been captured. The computed quantitative flow properties such as the radial base pressure distribution, model centerline Mach number and static pressure variation, and base pressure characteristic curve agreed reasonably well with those of the measurement. Parametric study on the effect of grid resolution, turbulence model, inlet boundary condition and difference scheme on convective terms has been performed. The results showed that grid resolution and turbulence model are two primary factors that influence the accuracy of the base flowfield prediction.

Wang, Ten-See↗

Numerical study of base pressure characteristic curve for a four-engine clustered nozzle configuration

The objective of this study is to benchmark a four-engine clustered nozzle base flowfield with a computational fluid dynamics (CFD) model. The CFD model is a three-dimensional pressure-based, viscous flow formulation. An adaptive upwind scheme is employed for the spatial discretization. The upwind scheme is based on second and fourth order central differencing with adaptive artificial dissipation. Qualitative base flow features such as the reverse jet, wall jet, recompression shock, and plume-plume impingement have been captured. The computed quantitative flow properties such as the radial base pressure distribution, model centerline Mach number and static pressure variation, and base pressure characteristic curve agreed reasonably well with those of the measurement. Parametric study on the effect of grid resolution, turbulence model, inlet boundary condition and difference scheme on convective terms has been performed. The results showed that grid resolution had a strong influence on the accuracy of the base flowfield prediction.

Wang, Ten-See↗

Numerical computation of transient coaxial entry tube flows

A numerical program was developed to compute transient laminar flows in two dimensions including multicomponent mixing and chemical reaction. The program can compute both incompressible flows and compressible flows at all speeds, and it is applied to describe transient and steady state solutions for low subsonic, coaxial entry, tue flows. Single component, nonreacting flows comprise most of the solutions, but one steady state solution is presented for trace concentration constituents engaging in a second order reaction. Numerical stability was obtained by adding at each calculation point a correction for numerical diffusion errors caused by truncation of the Taylor series used to finite difference the conservation equations. Transient computations were made for fluids initially at rest, then subjected to step velocity inputs that were uniform across each region of the entry plane and were held constant throughout the computation period. For center tube to annulus velocity ratios of 0.5 and 2.0, the bulk fluid in the tube initially moved in plug flow, but strong radial flows developed near the injection plane which moved the fluid into the high shear region between the jets and away from the tube wall.

Wieber, P. R.↗

Fluctuating surface pressure and acoustic radiation for subsonic normal jet impingement

Results are presented from an experimental study of fluctuating surface pressures and far-field noise produced by a subsonic circular jet impinging normally to a large, rigid, flat surface. The tests were performed in an anechoic room for jet Mach numbers from 0.54 to 0.85 and for jet-to-surface heights from 5 to 10 jet diameters. Space and time correlations of surface pressure indicated a radially spreading, decaying pressure field having correlation lengths on the order of one-half the jet diameter with convection speeds between 0.5 and 0.6 of the peak wall-jet velocity. Overall sound pressure level varied as the eighth power of the jet velocity. Large-scale orderly structures in the flow were suggested by the noise spectra which peaked at a Strouhal number of about 0.3. In addition, an analytical formulation was given to approximate the apparent noise-producing regions of the flow in terms of cross-correlations and cross-spectra between the surface and far-field measurements. Results pointed to the impingement region of the flow field as the major contribution to the far-field impingement noise.

Preisser, J. S.↗

The role of edge plasma parameters in H-mode density limit on the JET-ILW

A study of a dataset of JET H-mode plasma with the Be/W ITER-like wall (JET-ILW) shows that reaching the edge MHD ballooning limit leads to confinement degradation. However, unlike JET plasmas with a carbon wall (JET-C), the JET-ILW plasmas stay in a marginal dithering phase for a relatively long period, associated with a higher (≈20%) H-mode density limit (HDL) than JET-C equivalents. This suggests that ITER could be operated in H-mode with higher density than the scaling based on carbon wall devices, but likely with a dithering phase plasma with lower confinement. A new, reliable estimator for JET E r, min has been derived by combining HRTS measurements of pedestal gradient and edge-SOL decay lengths. JET radial E r ETB wells are observed in the range of -15 to -60 kV m -1 in high performance H-modes, consistent with previous CXRS results in ASDEX Upgrade. The results imply that a higher positive E × B shear in the near SOL plays a role in sustaining a marginal phase in JET-ILW which leads to a higher HDL than that in JET-C. The results of the JET-ILW dataset show agreement with the Goldston finite collisionality HD model for SOL broadening at high collisionality. A hypothesis for the dithering H-mode phase is proposed: as n e,SOL increases, ν *,SOL increases, SOL broadens, E r shear decreases, triggers L-mode; n e drops, ν *,SOL decreases, SOL becomes narrower, and E r shear increases, triggering H-mode, resulting in a cycle of H–L–H- oscillations. For burning plasma devices, such as ITER, operating just below the MHD limit for the dithering phase could be a promising regime for maximising core density, and fusion performance while minimising plasma-material interaction. The oscillatory signal during the dithering phase could be used as a precursor of undesirable plasma performance for control purposes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of Acoustically Lined Cylindrical Ducts on Instability Waves in Confined Supersonic Jets

The pressure disturbances generated by an instability wave in the shear layer of a supersonic jet are studied for an axisymmetric jet inside a lined cylindrical duct. For the supersonic jet, locally linear stability analysis with duct wall boundary conditions is used to calculate the eigenvalues and the eigenfunctions. These values are used to determine the growth rates and phase velocities of the instability waves and the radial pressure disturbance patterns. The study is confined to the dominant Kelvin-Helmholtz instability mode and to the region just downstream of the nozzle exit where the shear layer is growing but is still small in size compared to the radius of the duct. Numerical results are used to study the effects of changes in the outer flow, growth in the shear layer thickness, wall distance, wall impedance, and frequency. Results indicate that the effects of the duct wall on shear layer growth rates diminish as the outer flow increases. Also, wall reflections cause variations in growth rates depending on wall height and Strouhal number. These variations are due to the phase relationship between the outgoing and the reflected incoming pressure disturbances at the shear layer. The growth rate variations can be reduced and the maximum growth rate minimized by keeping the imaginary part of the impedance negative.

Dahl, Milo D.↗

Interpretation of Lyman opacity measurements in JET with the ITER-like wall using a particle balance approach

Recent measurements of the Ly β /D α ratio in the JET ITER-like wall (ILW) divertor show comparatively more pronounced Ly β reabsorption relative to previous results in JET with the carbon wall (JET-C). At the outer horizontal target ion current rollover point a Ly β reabsorption rate of 60% is measured, increasing to 80% in more pronounced detachment, implying a Ly α reabsorption rate of 90%–98%. The radially resolved Ly β /D α measurements are used to constrain Lyman opacity corrections to atomic rate coefficients using the population escape factor technique in order to capture the local changes to the excited state population structure in the high Lyman opacity regions at and outboard of the outer strike point. To check the self-consistency of the Lyman opacity measurements, a detailed spectroscopic interpretation of the outer divertor particle balance is presented, in which the impact of opacity corrections to the Ly α inverse photon efficiency coefficients is assessed. A five-fold deficit in the estimated D + source rate obtained with optically thin plasma assumptions is reconciled once the opacity corrections are factored into the Ly α photon rate to ionization rate conversion. The experiment results are reproduced in EDGE2D-EIRENE density scan simulations in which an imposed ad hoc Lyman reabsorption rate is recovered spectroscopically using synthetic measurements, and a similar shortfall in the D + source rate estimates is reconciled using Lyman opacity corrected atomic data. The model limitations prevent a more detailed self-consistent analysis of the Lyman opacity impact on divertor parameters and detachment evolution, and hence motivate renewed efforts to re-establish routine exploitation of the photon transport modelling capabilities in the EIRENE code package. Lyman opacity corrections to atomic data coefficients are necessary for spectroscopic interpretation of the JET-ILW divertor plasma, with significant influence on the divertor plasma also a likely consequence of the presence of strong Ly α reabsorption. Finally, a scan of auxiliary heating powers spanning L-mode and H-mode conditions reveals a strong correlation of the measured Ly β opacity with the outer target temperature, suggesting new possibilities for using Lyman opacity measurements in establishing detachment scalings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements to Understand the Flow Mechanisms Contributing to Tandem-Rotor Outwash

Downwash and outwash characteristics of a model-scale tandem-rotor system in the presence of the ground were analyzed by identifying and understanding the physical mechanisms contributing to the observed flow field behavior. A building block approach was followed in simplifying the problem, separating the effects of the fuselage, effects of one rotor on the other, etc. Flow field velocities were acquired in a vertical plane at four aircraft azimuths of a small-scale tandem rotor system using the particle image velocimetry (PIV) technique for radial distances up to 4 times the rotor diameter. Results were compared against full-scale CH-47D measurements. Excellent correlation was found between the small- and full-scale mean flow fields (after appropriate normalization using rotor and wall jet parameters). Following the scalability analysis, the effect of rotor height on the outwash was also studied. Close to the aircraft, an increase in rotor height above ground decreased the outwash velocity at all aircraft azimuths. However, farther away, the longitudinal and lateral axes of the aircraft showed increasing and decreasing outwash velocities, respectively, with increasing rotor height. Measurements also indicated the presence of large-scale (of the size of the rotor height) shear-layer vortical structures along the ground that could be the source of low-frequency (approximately 1 Hz) flow variation observed in the full-scale measurements. Flow visualization studies and PIV measurements were also made on jets of different sizes to complement the observations made on rotors wherever possible. Baseline rotor measurements were made out-of-ground effect to understand the nature of inflow distribution for realistic rotor configurations and their modified characteristics in the presence of ground. Lastly, a feasibility study on applying high-fidelity CFD simulations for outwash study was conducted using Helios to model an isolated rotor configuration IGE at full scale Reynolds number. The results were encouraging and demonstrated the practical challenges associated with predicting rotor outwash.

Measurements↗

Measurements to Understand the Flow Mechanisms Contributing to Tandem-Rotor Outwash

Downwash and outwash characteristics of a model-scale tandem-rotor system in the presence of the ground were analyzed by identifying and understanding the physical mechanisms contributing to the observed flow field behavior. A building block approach was followed in simplifying the problem, separating the effects of the fuselage, effects of one rotor on the other, etc. Flow field velocities were acquired in a vertical plane at four aircraft azimuths of a small-scale tandem rotor system using the particle image velocimetry (PIV) technique for radial distances up to 4 times the rotor diameter. Results were compared against full-scale CH-47D measurements. Excellent correlation was found between the small- and full-scale mean flow fields (after appropriate normalization using rotor and wall jet parameters). Following the scalability analysis, the effect of rotor height on the outwash was also studied. Close to the aircraft, an increase in rotor height above ground decreased the outwash velocity at all aircraft azimuths. However, farther away, the longitudinal and lateral axes of the aircraft showed increasing and decreasing outwash velocities, respectively, with increasing rotor height. Measurements also indicated the presence of large-scale (of the size of the rotor height) shear-layer vortical structures along the ground that could be the source of low-frequency (approximately 1 Hz) flow variation observed in the full-scale measurements. Flow visualization studies and PIV measurements were also made on jets of different sizes to complement the observations made on rotors wherever possible. Baseline rotor measurements were made out-of-ground effect to understand the nature of inflow distribution for realistic rotor configurations and their modified characteristics in the presence of ground. Lastly, a feasibility study on applying high-fidelity CFD simulations for outwash study was conducted using Helios to model an isolated rotor configuration IGE at full-scale Reynolds number. The results were encouraging and demonstrated the practical challenges associated with predicting rotor outwash.

Ramasamy, Manikandan↗

Impingement panel for a turbomachine

An integrated combustor nozzle includes a combustion liner that extends radially between an inner liner segment and an outer liner segment. The combustion liner includes a forward end portion, an aft end portion, a first side wall, and a second side wall. The aft end portion of the combustion liner defines a turbine nozzle. The integrated combustor nozzle further includes an impingement panel having an impingement plate disposed along an exterior surface of one of the inner liner segment or the outer liner segment. The impingement plate defines a plurality of impingement holes that direct coolant in discrete jets towards the exterior surface of the inner liner segment or the outer liner segment. The impingement panel is radially spaced from the exterior surface to form a cooling flow gap therebetween. The impingement panel includes a collection duct that extends from the impingement panel and defines a collection passage.

Berry, Jonathan Dwight↗

Experimental investigation of reactive turbulent recirculating jet mixing in a dump

A ducted, subsonic, hydrogen air turbulent jet mixing flowfield was investigated, both with and without combustion. The geometric configuration was representative of a sudden expansion or dump combustor, with a central air jet surrounded by a low velocity hydrogen stream at an overall equivalence ratio of 0.12. The ratio of the duct to inner nozzle diameter was 2.5. Radial distributions of mean axial and radial velocity, axial and radial turbulent intensity, velocity cross correlation, gas composition, static temperature and total pressure, as well as axial distributions of wall static pressure, were obtained for axial stations from zero to six duct diameters from the combustor entrance. The data indicate that mixing is slower in the chemically reactive flow field than in the nonreactive flow field, and that the presence of combustion has a significant effect on the size and location of the recirculation zone within the mixing duct.

Smith, G. D.↗

Impingement panel support structure and method of manufacture

An integrated combustor nozzle includes a combustion liner that extends between an inner liner segment and an outer liner segment along a radial direction. The combustion liner including a forward end portion, an aft end portion, a first side wall, and a second side wall. An impingement panel having an impingement plate disposed along an exterior surface of one of the inner liner segment or the outer liner segment. The impingement plate defines a plurality of impingement apertures that direct coolant in discrete jets towards the exterior surface of the inner liner segment or the outer liner segment. The impingement panel includes an inlet portion that extends from the impingement plate to a collection duct. The impingement panel further includes a plurality of supports spaced apart from one another. The plurality of supports extend between, and are coupled to, the inlet portion, the collection duct, and the impingement plate.