Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometer calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Solar Radiation Research Laboratory (SRRL) Core Project Final Report: Fiscal Years 2022-2024

The Solar Radiation Research Laboratory (SRRL) at the National Laboratory of the Rockies (NLR) is a world-leading solar calibration and measurement facility and maintains and disseminates the World Radiation Reference (essentially the W/m2) for the United States that is essential for traceable and accurate measurements of solar radiation at all solar generation facilities. SRRL operates two calibration facilities that meet International Standards Organization-17025 (ISO-17025) standards and provide unique high-quality calibrations to NREL and other U.S. Department of Energy laboratories. The Baseline Measurement System (BMS) at SRRL provides a high-quality record of solar irradiance and surface meteorological conditions. SRRL capabilities are used to develop (1) improved methods for the calibration of solar radiometers; (2) new standards through the ISO, the International Electrotechnical Commission (IEC), and the American Standards for Testing of Materials (ASTM) International; (c) solar radiation and meteorological models; and (d) advanced instrumentation and methods for operating solar measurement stations. The SRRL datasets are also critical for the validation of new models and datasets, such as the National Solar Radiation Database (NSRDB). The research and development of solar radiation measurement systems and resource modeling techniques are essential for advancing the scientific basis for producing reliable resource data. Specifically, the spatial, temporal, and spectral (wavelength dependency) characteristics of the solar resource are required in several different time frames for various project phases.

14 SOLAR ENERGY↗

Electron cyclotron emission measurements and modeling in optically semi-transparent plasma on the HSX stellarator

On the Helically Symmetric Experiment (HSX), electron cyclotron emission (ECE) at the second harmonic of the electron gyrofrequency is measured with a 16-channel heterodyne receiver. An ECE radiometer diagnostic has been calibrated with a broadband frequency source, allowing independent measurements of the electron temperature. The antenna pattern has a significant impact on the measurements, and modeling its effect is necessary to produce an ECE radiation temperature spectrum. Measurements, calibration results, and modeling of the ECE data are presented in this paper. At a relatively high plasma density, HSX plasmas are thermal, and the radiation temperature measured by the radiometer is in good agreement with the electron temperature measured by a Thomson scattering diagnostic. At a relatively low plasma density, the deviation from a Maxwellian distribution is large, and asymmetry in the radiation temperature profile is measured. These measurements are supported by single-pass and multi-pass ray tracing calculations of the electron cyclotron emission using the TRAVIS ray tracing code. Thermal and nonthermal electron populations exist in HSX, and the effect of these populations on the asymmetry in the measured emission is presented.

Cyclotron radiation↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗

Measured Long-Term Solar Irradiance for Climate Studies

Solar radiation is primarily measured using high-quality radiometers (e.g., pyranometers and pyrheliometers). These instruments need to be calibrated regularly (every two years at a minimum). They are also susceptible to various sources of uncertainties. Therefore, rigorous data quality assessment is required to obtain high-confidence data from these radiometers. This is especially true when the data is used to understand climatic trends and/or extreme weather events. In this study, we attempted to create a continuous and reliable dataset by correcting the underlying data which we believe contains bias due to reference pyranometers swap procedures. These biases can be significant which can be up to two percentage points thereby influencing the interpretation of climate changes and/or extreme events. This study elaborates on the biases and methods to correct those biases.

data integrity↗

New Absolute Cavity Pyrgeometer equation by application of Kirchhoff's law and adding a convection term

An equation for the Absolute Cavity Pyrgeometer (ACP) is derived from application of Kirchhoff's law and the addition of a convection term to account for the thermopile being open to the environment, unlike a domed radiometer. The equation is then used to investigate four methods to characterise key instrumental parameters using laboratory and field measurements. The first uses solar irradiance to estimate the thermopile responsivity, the second uses a minimisation method that solves for the thermopile responsivity and transmission of the cavity, and the third and fourth revisit the Reda et al. (2012) linear least squares calibration technique. Data were collected between January and November 2020, when the ACP96 and two IRIS radiometers monitoring terrestrial irradiances were available. The results indicate good agreement with IRIS irradiances using the new equation. The analysis also indicates that while the thermopile responsivity, concentrator transmission and emissivity of an ACP can be determined independently, as an open instrument, the impact of the convection term is minor in steady-state conditions but significant when the base of the instrument is being subjected to rapid artificial cooling or heating. Using laboratory characterisation of the transmission and emissivity, together with use of an estimated solar calibration of the thermopile, generated mean differences of less than 1.5 Wm -2 to the two IRIS radiometers. A minimisation method using each IRIS radiometer as the reference also provided similar results, and the derived thermopile responsivity was within 0.3 µV W -1 m 2 of the solar-calibration-derived infrared responsivity estimate of 10.5 µV W -1 m 2 estimated using a nominal solar calibration and provide irradiances within ±2 % of the terrestrial irradiance measured by the reference pyrgeometers traceable to the International System of Units (SI). The calibration method using linear least squares regression introduced by Reda et al. (2012) that relies on rapid cooling of the ACP base but utilising the new equation was found to produce consistent results but was dependent on the assumed temperature of the air above the thermopile. This study demonstrates the potential of the ACP as another independent reference radiometer for terrestrial irradiance once the magnitude of the convection coefficient and any potential variations in it have been resolved.

47 OTHER INSTRUMENTATION↗

Systems for passive microwave remote sensing and their calibration methods

A system for passive microwave remote sensing using at least one microwave radiometer includes a fixed body portion and a mobile body portion. The mobile body portion is configured for rotatably coupling with the fixed body portion for rotation about a rotation axis. The mobile body portion is configured for supporting the microwave radiometer therein such that the microwave radiometer rotates about the rotation axis when the mobile body portion is rotated about the rotation axis such that a polarization axis of the radiometer is aligned with an earth axis. The fixed body portion includes a motor mechanism for effecting rotation of the mobile body portion. In an embodiment, the mobile body portion includes a plurality of body section, each body section being configured for supporting a microwave radiometer therein. In another embodiment, each one of the plurality of body sections is configured to be interchangeably coupled with each other.

47 OTHER INSTRUMENTATION↗

Systems for passive microwave remote sensing and their calibration methods

A system for passive microwave remote sensing using at least one microwave radiometer includes a fixed body portion, the fixed body portion being configured to attach to a mobile platform, and a mobile body portion, the mobile body portion being configured for rotatably coupling with the fixed body portion for rotation about a rotation axis. The mobile body portion is configured for supporting the at least one microwave radiometer therein such that the at least one microwave radiometer rotates about the rotation axis when the mobile body portion is rotated about the rotation axis such that a polarization axis of the at least one radiometer is aligned with an earth axis. The fixed body portion includes a motor mechanism for effecting rotation of the mobile body portion such that the at least one microwave radiometer provides a vertical scanning below and above the mobile platform.

Klein, Marian↗

Integrating LEO and GEO Observations: Toward Optimal Summertime Satellite Precipitation Retrieval

Abstract Reliable quantitative precipitation estimation with a rich spatiotemporal resolution is vital for understanding the Earth’s hydrological cycle. Precipitation estimation over land and coastal regions is necessary for addressing the high degree of spatial heterogeneity of water availability and demand, and for resolving the extremes that modulate and amplify hazards such as flooding and landslides. Advancements in computation power along with unique high spatiotemporal and spectral resolution data streams from passive meteorological sensors aboard geosynchronous Earth-orbiting (GEO) and low Earth-orbiting (LEO) satellites offer exciting opportunities to retrieve information about surface precipitation phenomena using data-driven machine learning techniques. In this study, the capabilities of U-Net–like architecture are investigated to map instantaneous, summertime surface precipitation intensity at the spatial resolution of 2 km. The calibrated brightness temperature products from the Global Precipitation Measurement (GPM) Microwave Imager (GMI) radiometer are combined with multispectral images (visible, near-infrared, and infrared bands) from the Advanced Baseline Imager (ABI) aboard the GOES-R satellites as main inputs to the U-Net–like precipitation algorithm. Total precipitable water and 2-m temperature from the Global Forecast System (GFS) model are also used as auxiliary inputs to the model. The results show that the U-Net–like algorithm can capture fine-scale patterns and intensity of surface precipitation at high spatial resolution over stratiform and convective precipitation regimes. The evaluations reveal the potential of extracting relevant, high spatial features over complex surface types such as mountainous regions and coastlines. The algorithm allows users to interpret the inputs’ importance and can serve as a starting point for further exploration of precipitation systems within the field of hydrometeorology.

Meteorology & Atmospheric Sciences↗

An On-Sky Atmospheric Calibration of SPT-SLIM

We present the methodology and results of the on-sky responsivity calibration of the South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM). SPT-SLIM is a pathfinder line intensity mapping experiment utilizing the on-chip spectrometer technology, and was first deployed during the 2024-2025 Austral Summer season on the South Pole Telescope. During the two-week on-sky operation of SPT-SLIM, we performed periodic measurements of the detector response as a function of the telescope elevation angle. Combining these data with atmospheric opacity measurements from an on-site atmospheric tipping radiometer, simulated South Pole atmospheric spectra, and measured detector spectral responses, we construct estimates for the responsivity of SPT-SLIM detectors to sky loading. We then use this model to calibrate observations of the moon taken by SPT-SLIM, cross-checking the result against the known brightness temperature of the Moon as a function of its phase.

Dibert, K. R. [Chicago U., Astron. Astrophys. Ctr.↗

The Shortwave Spectral Radiometer for Atmospheric Science: Capabilities and Applications from the ARM User Facility

Industry advances have greatly reduced the cost and size of ground-based shortwave (SW) sensors for the ultraviolet, visible, and near-infrared spectral ranges that make up the solar spectrum, while simultaneously increasing their ruggedness, reliability, and calibration accuracy needed for outdoor operation. These sensors and collocated meteorological equipment are an important part of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility, which has supported parallel integrated measurements of atmospheric and surface properties for more than two decades at fixed and mobile sites around the world. The versatile capability of these ground-based measurements includes 1) rich spectral information required for retrieving cloud and aerosol microphysical properties, such as cloud phase, cloud particle size, and aerosol size distributions, and 2) high temporal resolution needed for capturing fast evolution of cloud microphysical properties in response to rapid changes in meteorological conditions. Here we describe examples of how ARM's spectral radiation measurements are being used to improve understanding of the complex processes governing microphysical, optical, and radiative properties of clouds and aerosol.

54 ENVIRONMENTAL SCIENCES↗

Monitoring water quality in the lower Kansas River using remote sensing

Abstract We demonstrate how to combine remote sensing data from satellite imagery (Sentinel‐2) with in situ water quality gauging (USGS Super Gages and the Gybe hyperspectral radiometer) to create spatially dense maps of water quality parameters (chlorophyll‐a concentration, turbidity, and nitrate plus nitrite concentration) along the lower Kansas River. The water quality maps are created using locally tuned models of the target water quality parameters, and this study describes the steps used to design, calibrate, and validate the empirical correlations. Water quality parameters such as chlorophyll‐a concentration are correlated with well‐studied absorption and scattering features in the visible spectrum (roughly 400–700 nm). Nutrients (such as nitrate plus nitrite concentration) lack strong absorption features in the visible spectrum, and in those cases we describe a novel surrogate data modeling approach that identifies overlapping water parcels between the in situ gauging and the remote sensing imagery. Measurements from the overlapping water parcels yield excellent correlations () for the target water quality parameters for limited windows of time (or limited sections of river reaches). Examples are provided illustrating how the water quality maps can be used to track river inputs from ungauged sources (such as creeks), or reveal the mixing patterns at the confluences.

Tufillaro, Nicholas↗

SPATIOTEMPORAL TRACKING OF WIDE AREA POWER OUTAGE FROM NIGHT-TIME LIGHT IMAGERY

Monitoring progress of power restoration following extreme events is essential for situational awareness about spatio-temporal distribution of populations without power and to help with response efforts. Because of the proprietary nature of restoration data, and the difficulty in obtaining power outage data from utility companies in near real-time (e.g., during hurricane Maria (2017)), this project used satellite derived nighttime lights data from Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band (DNB) to (i) monitor wide area power outage and (ii) estimate impacted customers over time to assist with restoration. A discussion of the methodology and its implementation during hurricanes Maria (2017) and Eta (2020) is presented in this paper. Future work will focus on calibrating estimated customers based on light intensity and density distribution, and generation of restoration profiles for emergency response.

Kar, Bandana↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 25-October 6, 2023

The comparison of the absolute cavity pyrgeometers (ACPs) with the InfraRed Integrating Sphere (IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 25 to October 6, 2023. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. During the comparison, the average (av) irradiance difference measured by ACPs and IRIS9 varied from -0.75 W/m 2 to 0.76 W/m 2 , standard deviation (sd) from 0.78 W/m 2 to 1.04 W/m 2 , and uncertainty U95 from 1.96 W/m 2 to 2.07 W/m 2 . The average irradiance difference measured by ACP95F3 minus the irradiance measured by all pyrgeometers varied from 1.64 to 3.96 W/m 2 , sd from 1.70 W/m 2 to 1.86 W/m 2 , and uncertainty U 95 from 3.78 W/m 2 to 5.42W/m 2 . Note that from September 25th at 18:31 to September 29 th at 5:30 ACP96F3 irradiance is calculated using Bruce, et al 2023 method.

47 OTHER INSTRUMENTATION↗

Improved Primary Reference Cell Calibrations for Higher Accuracy Photovoltaic Cell and Module Performance Measurements

The adoption of photovoltaic (PV) modules for clean electricity relies on accurate measurements of their performance, which are essential for estimating their energy production potential. Herein, the calibration chain of PV cells and modules, with particular emphasis on primary reference cell calibrations, is discussed. Also, herein, the direct sunlight method the group has developed for these calibrations is presented and critical improvements and upgrades that lead to calibration uncertainty as low as 0.45% are discussed. The ultimate motivation behind this work is to provide low‐uncertainty performance measurements of PV modules, and lowering the calibration uncertainty of primary reference cells is a key first step toward achieving this goal. As the use of solar electricity continues to grow, the demand for primary reference cell calibrations inevitably increases beyond what the small handful of primary calibration laboratories can provide today. Therefore, this work can serve as a useful guide for implementing primary PV reference cell calibrations using the outdoor method, as well as outlining the critical elements required to make these calibrations highly accurate.

Osterwald, Carl R.↗

Progress in ITER ECE diagnostic design and integration

The ITER electron cyclotron emission (ECE) diagnostic system has primary roles in providing measurements of the core electron temperature profile and the electron temperature fluctuation associated with the neoclassical tearing modes. The ITER ECE system includes a radial and oblique line-of-sight. Four 43-meter long low-loss transmission lines (TLs) are designed to transmit millimeter wave power in the frequency range of 70–1000 GHz in both X- and O-mode polarization from the port plug to the ECE instrumentation room in the diagnostic building. The measurement instrumentation includes two Fourier transform spectrometer (FTS) systems and two radiometer systems. The Indian Domestic Agency (IN-DA) and United States Domestic Agency share the responsibility. The IN-DA scope excluding instrumentation and control has passed its preliminary design review and is progressing towards the final design review (FDR). In parallel, the diagnostic integration in different areas is ongoing. Furthermore, several captive components for the TLs have passed FDR and will be manufactured for installation in the tokamak building soon. A peer review meeting has been held on the prototype hot calibration source, and its integration and new thermal analysis in the diagnostic shield module are continuing. A prototype TL is being tested. A prototype polarizing Martin-Puplett type FTS, operating in the frequency range 70–1000 GHz, features an in-vacuo fast scanning mechanism and a cryo-cooled dual-channel THz detector system. Its performance has been assessed in detail against ITER requirements.

47 OTHER INSTRUMENTATION↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 26-October 7, 2022

The comparison of the absolute cavity pyrgeometers (ACPs) with the InfraRed Integrating Sphere (IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 26 to October 7, 2022. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. During the comparison, the average (av) irradiance difference measured by ACPs and IRIS varied from -0.80 W/m2 to 0.29 W/m2 and standard deviation (sd) from 0.98 W/m2 to 1.78 W/m2. The average irradiance difference measured by ACP95F3 minus the irradiance measured by all pyrgeometers varied from 2.07 to 5.03 W/m2 with sd from 2.64 W/m2 to 2.67 W/m2.

14 SOLAR ENERGY↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 23-October 4, 2024

The comparison of the absolute cavity pyrgeometers (ACPs) with the CG4 FT005 pyrgeometer traceable to the InfraRed Integrating Sphere (IRIS) referred to by FT005(IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 23 to October 4, 2024. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. Two methods described in and were used for the comparison based on original Reda et. al and proposed Forgan et. al.

47 OTHER INSTRUMENTATION↗

Persistent global greening over the last four decades using novel long-term vegetation index data with enhanced temporal consistency

Advanced Very High-Resolution Radiometer (AVHRR) satellite observations have provided the longest global daily records from 1980s, but the remaining temporal inconsistency in vegetation index datasets has hindered reliable assessment of vegetation greenness trends. To tackle this, we generated novel global long-term Normalized Difference Vegetation Index (NDVI) and Near-Infrared Reflectance of vegetation (NIRv) datasets derived from AVHRR and Moderate Resolution Imaging Spectroradiometer (MODIS). We addressed residual temporal inconsistency through three-step post processing including cross-sensor calibration among AVHRR sensors, orbital drifting correction for AVHRR sensors, and machine learning-based harmonization between AVHRR and MODIS. After applying each processing step, we confirmed the enhanced temporal consistency in terms of detrended anomaly, trend and interannual variability of NDVI and NIRv at calibration sites. Our refined NDVI and NIRv datasets showed a persistent global greening trend over the last four decades (NDVI: 0.0008 yr -1 ; NIRv: 0.0003 yr -1 ), contrasting with those without the three processing steps that showed rapid greening trends before 2000 (NDVI: 0.0017 yr -1 ; NIRv: 0.0008 yr -1 ) and weakened greening trends after 2000 (NDVI: 0.0004 yr -1 ; NIRv: 0.0001 yr -1 ). These findings highlight the importance of minimizing temporal inconsistency in long-term vegetation index datasets, which can support more reliable trend analysis in global vegetation response to climate changes.

54 ENVIRONMENTAL SCIENCES↗