DrEVL Radiometer Calibration

This report details the calibration procedures that were used for the spectral and radiometric part of the DrEVL radiometers. Our goal was to develop a highly repeatable and low cost spectral radiometer that could be deployed at numerous sites to collect a catalog of lightning data. Maximizing the re-usability of that data requires a well-calibrated instrument.

47 OTHER INSTRUMENTATION↗

Snow ALbedo eVOlution (SALVO) Campaign Spectral Albedo and Related Measurements from April - June, 2024 in Utqiagivk, AK

A field-portable spectroradiometer, referred to herein as an ‘ASD’, was used to make spatially-distributed spectral albedo (350 – 2500 nm) measurements on tundra and sea ice surfaces. The ASD detector is carried in a backpack and controlled via a computer mounted on the front of the operator (see Figure 1). The ASD measures the spectral irradiance from a fiber optic cable that is routed from the backpack to a custom, gooseneck cosine collector mounted on the end of a 1-m long boom (Grenfell and Perovich, 2008). The boom was held at hip height (approximately 1 m) and had an integrated bubble level for levelling. To make an albedo measurement, first the operator collect an incident (down-welling) irradiance, followed by a reflected (up-welling) measurement. The time between incident and reflected measurements was typically between 11 and 26 seconds (interquartile range). For each measurement, 10 spectra are averaged together. Albedo is calculated as the ratio of the reflected to incident measurement, which obviates the need for absolute radiometric calibration. Albedo measurements were taken parallel to the 200-m albedo lines at 5-m increments (41 measurements) ~1 m south of the line. While the ASD operator was making measurements, an assistant kept notes on the scan number associated with each measurement, the surface type (see below), and collected photos of each measurement (see companion oblique photos data archive). Measurements were made within 3 hours of solar noon.

ASD Spectroradiometer↗

NWB Sensors Infrared Cloud Imager Data Products from SGP

NWB Sensors is a company which has developed a commercially available Infrared Cloud Imager (ICI). For more information, consult the company's webpage, https://www.nwbsensors.com/infrared-cloud-imager. To validate the radiometric accuracy of the ICI, NWB Sensors deployed it to the ARM SGP User Facility in 2023. The primary motivation of this deployment was to perform an intercomparison between the ICI and the Atmospheric Emitted Radiance Interferometer (AERI). The AERI spectral radiance data product can be integrated across the response function of the ICI and directly compared to the zenith radiance observed by the ICI. In addition, the ICI uses proprietary models of the downwelling clear-sky radiance in its cloud processing algorithms. They are based on surface meteorology and precipitable water vapor (PWV). These models were validated by comparing their predicted radiances to those derived from radiative transfer models of the ARM radiosondes. Finally, PWV observations derived from the ICI's onboard GNSS-based PWV retrieval system were compared against those from the microwave radiometer. This dataset contains the ICI radiance and cloud data products.

Atmosphere↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

Kryptonate Hydrogen Detection System (Final Report)

A prototype model of a multipurpose instrument which demonstrates the applicability of the Kryptonate® technique for detecting hydrogen gas was developed. This report describes the construction of the instrument and presents a laboratory evaluation of its performance. Performance was excellent. The instrument was designed to detect hydrogen in air at concentrations of 0-3% by volume, and to detect hydrogen in nitrogen or other inert gas at concentrations of 0-10% by volume. Other detection levels (both higher and lower) could be set if required. Ultimate response times can be made of the order of 0.5 seconds. The instrument is an all solid state device operating from 120V 60 Hz power source. The instrument has been designed to enable modifications to be made with a minimum amount of difficulty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗