Search NASA⌕ Search

SEARCH · Search NASA

Results for “ranging tracking data tracking interface”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Markerless tracking of small lung tumors for stereotactic radiotherapy

Purpose: (1) To validate retrospective markerless tracking software for small lung tumors by comparing tracked motion in 4-dimensional planning computed tomography (4DCT) derived kV projection images and known tumor motion in the same 4DCT. (2) To evaluate variability of tumor motion using kV projection images from cone-beam computed tomography (CBCT) scans acquired on different days. Methods: Nonclinical tumor tracking software (TTS) used a normalized cross correlation algorithm to track the tumor on enhanced kV projection images (e.g., from a CBCT scan). The reference dataset consisted of digitally reconstructed radiographs (DRRs) from one phase of a planning 4DCT. TTS matches two in-plane coordinates and obtains the out-of-plane coordinate by triangulating with match results from other projections. (1) To validate TTS, tracking results were compared with known 4DCT tumor motion for two patients (A and B). Projection images (1 image/1°) were digitally reconstructed for each 4DCT phase. From these, kV projection series were composed simulating full breathing cycles every 20° of gantry rotation [breathing period = 20°/(6°/s) = 3.33 s]. Reference templates were 360 “tumor enhanced” DRRs from the 4DCT expiration phase. TTS-derived tumor motion was compared to known tumor motion on 4DCT. (2) For five patients, TTS-assessed motion during clinical CBCT acquisition was compared with motion on the planning 4DCT, and the motion component in the Y (cranio–caudal)-direction was compared with the motion of an external marker box (RPM, real-time position management). Results: (1) Validation results: TTS for case A (tumor 6.2 cm{sup 3}, 32 mm axial diameter) over 360° showed mean motion X (medial–lateral) = 3.4, Y = 11.5, and Z (ventral–dorsal) = 4.9 mm (1 SD < 1.0 mm). Corresponding 4DCT motion was X = 3.1, Y = 11.3, and Z = 5.1 mm. Correlation coefficients between TTS tumor motion and displacement of the tumor’s center of mass (CoM) on 4DCT were 0.64, 0.96, and 0.82 (X, Y, and Z, respectively). For case B (4.1 cm{sup 3}, 20 mm diameter), due to temporarily decreased tumor visibility preventing TTS from resolving the tumor, robust tracking data were only available between angles 300°–40° and 120°–220°. Mean motion according to TTS was X = 2.0, Y = 7.7, and Z = 8.2 mm (1 SD < 0.9 mm). Tumor motion on 4DCT was X = 1.8, Y = 7.6, and Z = 9.5 mm and correlation coefficients between TTS motion and CoM displacement were 0.59, 0.95, and 0.93 (X, Y, and Z, respectively). (2) Clinical results: TTS revealed a mean intrafraction variation in tumor motion in Y-direction of >2.0 mm (1 SD) in four of five patients. In addition, clinical tumor motion amplitude differed from that seen on planning 4DCT. Internal and external structures that create abrupt density change (e.g., table-top edge, interface between lung/mediastinum and lung/heart) were observed to prevent 360° tracking of the tumor. Correlation coefficients between TTS motion in the Y-direction and the RPM signal (22 observations) ranged from 0.78 to 0.96. In 2D, 241 TTS matches at end-inspiration and end-expiration were visually validated: mean difference was 0.8 mm (SD = 0.7) for both. Conclusions: TTS can track small lung tumors if these are visible in kV projections. A 4DCT dataset can be used to validate kV tracking of moving targets. TTS and 4DCT displacement agreed to within 2 mm. TTS and RPM motion were closely associated but tumor motion during CBCT can vary from the planning 4DCT.

60 APPLIED LIFE SCIENCES↗

A multiphysics coupling framework for exascale simulation of fracture evolution in subsurface energy applications

Predicting the evolution of fractured media is challenging due to coupled thermal, hydrological, chemical and mechanical processes that occur over a broad range of spatial scales, from the microscopic pore scale to field scale. We present a software framework and scientific workflow that couples the pore scale flow and reactive transport simulator Chombo-Crunch with the field scale geomechanics solver in GEOS to simulate fracture evolution in subsurface fluid-rock systems. This new multiphysics coupling capability comprises several novel features. An HDF5 data schema for coupling fracture positions between the two codes is employed and leverages the coarse resolution of the GEOS mechanics solver which limits the size of data coupled, and is, thus, not taxed by data resulting from the high resolution pore scale Chombo-Crunch solver. The coupling framework requires tracking of both before and after coarse nodal positions in GEOS as well as the resolved embedded boundary in Chombo-Crunch. We accomplished this by developing an approach to geometry generation that tracks the fracture interface between the two different methodologies. The GEOS quadrilateral mesh is converted to triangles which are organized into bins and an accessible tree structure; the nodes are then mapped to the Chombo representation using a continuous signed distance function that determines locations inside, on and outside of the fracture boundary. The GEOS positions are retained in memory on the Chombo-Crunch side of the coupling. The time stepping cadence for coupled multiphysics processes of flow, transport, reactions and mechanics is stable and demonstrates temporal reach to experimental time scales. The approach is validated by demonstration of 9 days of simulated time of a core flood experiment with fracture aperture evolution due to invasion of carbonated brine in wellbore-cement and sandstone. We also demonstrate usage of exascale computing resources by simulating a high resolution version of the validation problem on OLCF Frontier.

97 MATHEMATICS AND COMPUTING↗

Development of a Comprehensive and Centralized Waste Management System - 19412

Information Systems Laboratories (ISL) has designed a new single, integrated, waste management and control system to administer all aspects of nuclear waste management. The overriding goal of the initiative is to provide federal, state, and local agencies with operational awareness, management, and programmatic support for all functions related to nuclear waste management. Over decades of waste management federal agencies have sponsored or directly paid for the development, operation, and control of multiple systems to track and control its waste - with varied success. Multiple contractors have generated disparate control systems/databases and literally mountains of data. Past approaches have not provided a single, integrated, real time data management system. ISL's analysis of past failed efforts has reveal four common symptoms: - Control/management systems that are not compatible; - Programmatic costs that increase with systems use and re-work; - Systems focused on specific sets of data; - Inaccurate or outdated data sets. An integrated waste management and control system that collects and displays real-time, accurate inventory, waste container certification, transportation certification, emplacement, and shipment related data improve operational awareness and overcomes these limitations. Using its vast knowledge and experience in developing numerous waste tracking and management systems, ISL has leveraged its own in-house knowledge and gathered requests from stakeholders all across the industry to design a system that meets the needs of users at all levels of the nuclear waste management process. Using the highly successful and widely used Waste Data System (WDS) designed for the Waste Isolation Pilot Plant as a core component, ISL has designed a system that greatly expands on the functionality of the WDS to exceed its current focus of management of Transuranic Waste shipments. The new system is designed to provide the ability to track a wide range of waste types from Transuranic, High Level, Low Level, Mixed, and any nuclear related material. The main focus of the system is to provide federal regulators a comprehensive and real-time oversight into the handling of all nuclear waste materials. Oversight activities include, but are not limited to, strategy development, projections, metrics, incentive development, tracking, budget review, government cost estimating, and integrated schedules. The major components of the system are summarized below: - The Centralized Waste Management System (CWMS), which will include assimilating and validating known sources of data into the CWMS. - The programmatic reporting support component, which will handle queries from regulators, track compliance with regulatory requirements, and maintain the dashboard for federal management. - Both the CWMS and the programmatic reporting support component will use a standard set of business rules that govern system operations and allow site and program specific needs and limits for all waste programs and types to be captured and maintained. This presentation will provide details of each component of the system detailing its use, interfaces with other components, and value to stakeholders. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Kinetics of the Carbothermic Reduction of Manganese Oxide from Slag

Experiments were performed using a range of test conditions to elucidate the rate controlling step during the reaction of liquid iron-carbon droplets and slags containing manganese oxide. Four conditions were tested in the system: initial MnO content in the slag (5, 10, and 15 wt pct), initial carbon content of the metal (1, 2.5, 4.3 wt pct), initial droplet mass (0.5, 1.0, and 1.5 g), and reaction temperature (1823 K [1550 °C], 1873 K [1600 °C], and 1923 K [1650 °C]). Data were collected using the Constant Volume Pressure Increase (CVPI) technique which tracked the continuous pressure increase in the sealed furnace over time. Samples were quenched at the end of each experiment and chemistry was checked using LECO Carbon Analysis and ICP (Inductively Coupled Plasma) for manganese. The rate of reaction can be broken into a faster initial period related to internal CO formation, and a slower second reaction controlled by a complex mechanism involving transport of oxygen from slag to metal via CO{sub 2} and decomposition of the CO{sub 2} at the gas–metal interface.

36 MATERIALS SCIENCE↗

Automated characterization of perceptual quality of clinical chest radiographs: Validation and calibration to observer preference

Purpose: The authors previously proposed an image-based technique [Y. Lin et al. Med. Phys. 39, 7019–7031 (2012)] to assess the perceptual quality of clinical chest radiographs. In this study, an observer study was designed and conducted to validate the output of the program against rankings by expert radiologists and to establish the ranges of the output values that reflect the acceptable image appearance so the program output can be used for image quality optimization and tracking. Methods: Using an IRB-approved protocol, 2500 clinical chest radiographs (PA/AP) were collected from our clinical operation. The images were processed through our perceptual quality assessment program to measure their appearance in terms of ten metrics of perceptual image quality: lung gray level, lung detail, lung noise, rib–lung contrast, rib sharpness, mediastinum detail, mediastinum noise, mediastinum alignment, subdiaphragm–lung contrast, and subdiaphragm area. From the results, for each targeted appearance attribute/metric, 18 images were selected such that the images presented a relatively constant appearance with respect to all metrics except the targeted one. The images were then incorporated into a graphical user interface, which displayed them into three panels of six in a random order. Using a DICOM calibrated diagnostic display workstation and under low ambient lighting conditions, each of five participating attending chest radiologists was tasked to spatially order the images based only on the targeted appearance attribute regardless of the other qualities. Once ordered, the observer also indicated the range of image appearances that he/she considered clinically acceptable. The observer data were analyzed in terms of the correlations between the observer and algorithmic rankings and interobserver variability. An observer-averaged acceptable image appearance was also statistically derived for each quality attribute based on the collected individual acceptable ranges. Results: The observer study indicated that, for each image quality attribute, the averaged observer ranking strongly correlated with the algorithmic ranking (linear correlation coefficient R > 0.92), with highest correlation (R = 1) for lung gray level and the lowest (R = 0.92) for mediastinum noise. There was a strong concordance between the observers in terms of their rankings (i.e., Kendall’s tau agreement > 0.84). The observers also generally indicated similar tolerance and preference levels in terms of acceptable ranges, as 85% of the values were close to the overall tolerance or preference levels and the differences were smaller than 0.15. Conclusions: The observer study indicates that the previously proposed technique provides a robust reflection of the perceptual image quality in clinical images. The results established the range of algorithmic outputs for each metric that can be used to quantitatively assess and qualify the appearance quality of clinical chest radiographs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the production of charm jets tagged with D 0 mesons in pp collisions at $\sqrt{\mathrm{s}}=7$ TeV

The production of charm jets in proton-proton collisions at a center-of-mass energy of $\sqrt{\mathrm{s}}=7$ TeV was measured with the ALICE detector at the CERN Large Hadron Collider. The measurement is based on a data sample corresponding to a total integrated luminosity of 6.23 nb -1 , collected using a minimum-bias trigger. Charm jets are identified by the presence of a D 0 meson among their constituents. The D 0 mesons are reconstructed from their hadronic decay D 0 → $K^-π^+$. The D 0 -meson tagged jets are reconstructed using tracks of charged particles (track-based jets) with the anti-$k$ T algorithm in the jet transverse momentum range 5 < p T , j e t c h 30 GeV/ c and pseudorapidity |$η$ jet | < 0.5. The fraction of charged jets containing a D 0 -meson increases with p T , j e t c h from 0.042 ± 0.004 (stat) ± 0.006 (syst) to 0.080 ± 0.009 (stat) ± 0.008 (syst). The distribution of D 0 -meson tagged jets as a function of the jet momentum fraction carried by the D 0 meson in the direction of the jet axis ( z &#x2225;<!-- ∥ --> c h ) is reported for two ranges of jet transverse momenta, 5 < p T , j e t c h < 15 GeV/ c and 15 < p T , j e t c h < 30 GeV/ c in the intervals 0.2 < z &#x2016; c h < 1.0 and 0.4 < z &#x2016; c h < 1.0 respectively. The data are compared with results from Monte Carlo event generators (PYTHIA 6, PYTHIA 8 and Herwig 7) and with a Next-to-Leading-Order perturbative Quantum Chromodynamics calculation, obtained with the POWHEG method and interfaced with PYTHIA 6 for the generation of the parton shower, fragmentation, hadronisation and underlying event.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An on-line acoustic fluorocarbon coolant mixture analyzer for the ATLAS silicon tracker

The ATLAS silicon tracker community foresees an upgrade from the present octafluoro-propane (C{sub 3}F{sub 8}) evaporative cooling fluid - to a composite fluid with a probable 10-20% admixture of hexafluoro-ethane (C{sub 2}F{sub 6}). Such a fluid will allow a lower evaporation temperature and will afford the tracker silicon substrates a better safety margin against leakage current-induced thermal runaway caused by cumulative radiation damage as the luminosity profile at the CERN Large Hadron Collider increases. Central to the use of this new fluid is a new custom-developed speed-of-sound instrument for continuous real-time measurement of the C{sub 3}F{sub 8}/C{sub 2}F{sub 6} mixture ratio and flow. An acoustic vapour mixture analyzer/flow meter with new custom electronics allowing ultrasonic frequency transmission through gas mixtures has been developed for this application. Synchronous with the emission of an ultrasound 'chirp' from an acoustic transmitter, a fast readout clock (40 MHz) is started. The clock is stopped on receipt of an above threshold sound pulse at the receiver. Sound is alternately transmitted parallel and anti-parallel with the vapour flow for volume flow measurement from transducers that can serve as acoustic transmitters or receivers. In the development version, continuous real-time measurement of C{sub 3}F{sub 8}/C{sub 2}F{sub 6} flow and calculation of the mixture ratio is performed within a graphical user interface developed in PVSS-II, the Supervisory, Control and Data Acquisition standard chosen for LHC and its experiments at CERN. The described instrument has numerous potential applications - including refrigerant leak detection, the analysis of hydrocarbons, vapour mixtures for semiconductor manufacture and anesthetic gas mixtures. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Picometer-Precision Atomic Position Tracking through Electron Microscopy

The modern aberration-corrected scanning electron microscopes have successfully achieved direct visualization of atomic columns with sub-angstrom resolution. With this significant progress, advanced image quantification and analysis is still at its early stages. In this work, we present the complete pathway for the metrology of atomic resolution STEM images. This includes: 1) tips for acquiring high-quality STEM images; 2) denoising and drift-correction for enhancing measurement accuracy; 3) obtaining initial atom positions; 4) indexing the atoms based on unit cell vectors; 4) quantifying the atom column positions with either 2D-gaussian single peak fitting or 5) multi-peak fitting routines for slightly overlapping atomic columns; 6) quantification of lattice distortion/strain within the crystal structures or at the defects/interfaces where the lattice periodicity is disrupted, and 7) some common methods to visualize and present the analysis. Furthermore, a simple self-developed free MATLAB app (EASY-STEM) with a graphical user interface (GUI) will be introduced that can help with the analysis of STEM images without the need for writing dedicated analysis code or software. The advanced data analysis methods presented here can be applied for the local quantification of defect relaxations, local structural distortions, local phase transformations, and non-centrosymmetry in a wide range of materials.

47 OTHER INSTRUMENTATION↗

Spatially Resolved Recombination Analysis of CuIn $_\text{x}$ Ga $_\text{1-x}$ Se $_{2}$ Absorbers With Alkali Postdeposition Treatments

In this contribution, we probe spatial variations in charge-carrier recombination in CuIn x Ga 1-x Se 2 (CIGS) absorbers grown on soda-lime glass (SLG) and alkali-free sapphire substrates with NaF and KF postdeposition treatments (PDTs). Temperature-and illumination-dependent device measurements are used to track interface recombination and recombination in the quasi-neutral region. The analysis of these data reveals that the benefit of alkali PDTs depends on the substrate: interface recombination is reduced in devices grown on sapphire substrates, whereas recombination in the quasi-neutral regions is reduced in devices grown on SLG substrates. Cathodoluminescence (CL) spectrum imaging is used to study the spatial distribution of recombination with respect to the grain structure. The grain-boundary CL contrast is similar in films with no PDT, NaF PDT, or KF PDT. A reduced grain-boundary contrast is observed with a NaF + KF PDT; however, suggesting a reduced recombination strength at the grain boundaries (GBs) for combined NaF + KF treatment. CL spectra indicate band tailing, consistent with the fluctuating potential model. Fluctuating potentials are believed to reduce open-circuit voltage, but their spatial distribution has not been studied. Here, CL spectrum imaging data are used to generate maps of the root-mean-square value of the potential energy fluctuations-γ. These maps reveal a bimodal ..gamma.. distribution for all samples: ..gamma.. is generally in the range ~15-50 meV or ~100-180 meV. The higher ..gamma.. range is more significantly affected by the PDTs; after the PDTs, it is strongly correlated with GBs. The lower ..gamma.. range is correlated with higher emission intensity regions, typically grain interiors, and increases in area fraction after the PDTs. These results demonstrate how spatially resolved luminescence and device characterization measurements can be used to monitor changes in recombination in CIGS films and photovoltaic devices. Such measurements can complement empirical device optimization and help improve device performance.

14 SOLAR ENERGY↗

The interaction of climate change and methane hydrates

Gas hydrate, a frozen, naturally-occurring, and highly-concentrated form of methane, sequesters significant carbon in the global system and is stable only over a range of low-temperature and moderate-pressure conditions. Gas hydrate is widespread in the sediments of marine continental margins and permafrost areas, locations where ocean and atmospheric warming may perturb the hydrate stability field and lead to release of the sequestered methane into the overlying sediments and soils. Methane and methane-derived carbon that escape from sediments and soils and reach the atmosphere could exacerbate greenhouse warming. The synergy between warming climate and gas hydrate dissociation feeds a popular perception that global warming could drive catastrophic methane releases from the contemporary gas hydrate reservoir. Appropriate evaluation of the two sides of the climate-methane hydrate synergy requires assessing direct and indirect observational data related to gas hydrate dissociation phenomena and numerical models that track the interaction of gas hydrates/methane with the ocean and/or atmosphere. Methane hydrate is likely undergoing dissociation now on global upper continental slopes and on continental shelves that ring the Arctic Ocean. Many factors—the depth of the gas hydrates in sediments, strong sediment and water column sinks, and the inability of bubbles emitted at the seafloor to deliver methane to the sea-air interface in most cases—mitigate the impact of gas hydrate dissociation on atmospheric greenhouse gas concentrations though. There is no conclusive proof that hydrate-derived methane is reaching the atmosphere now, but more observational data and improved numerical models will better characterize the climate-hydrate synergy in the future.

54 ENVIRONMENTAL SCIENCES↗

Deliver Signal Phase and Timing (SPAT) for Energy Optimization of Vehicle Cohort Via Cloud-Computing and LTE Communications

Predictive Signal Phase and Timing (SPAT) message set is one fundamental building block for vehicle-to-infrastructure (V2I) applications such as Eco-Approach and Departure (EAD) at traffic signal controlled urban intersections. Among the two complementary communication methods namely short-range sidelink (PC5) and long-range cellular radio link (Uu), this paper documents the work with long-range link: the complete data chain includes connecting to the traffic signals via existing backhaul communication network, collecting the raw signal phase state data, predicting the signal state changes and delivering the SPAT data via a geofenced service to requests over HTTP protocols. An Application Programming Interface (API) library is developed to support various cellular data transmission reduction and latency improvement techniques. An emulation-based algorithm is applied to predict the traffic signal state changes to provide adequate prediction horizon (e.g., at minimum 2 minutes) for the cohort energy optimization. In fact, the same connectivity and SPAT delivery methodology has been applied to traffic signalized intersections nationwide in the United States upon public agency approvals for access to their firewalled traffic control network and signal control systems or directly to individual controllers. This methodology proves its effectiveness and potential for rapid growth of such SPAT deliveries at mass production scale without needing infrastructure hardware retrofit or excessive communication means. To support the energy optimization of light and heavy-duty vehicle cohorts of mixed automation and propulsion systems (EV, ICE and hybrid), the connection and SPAT deliveries at two sites were completed, including public roads in Washtenaw County, Michigan and closed track test sites at American Center for Mobility (ACM) in Ypsilanti, Michigan. However, only closed test track results at ACM will be presented in this paper. A neuroevolution based optimizer is developed and implemented to control the speed of a vehicle cohort with different propulsion systems and automation levels. Closed track tests showed significant energy savings of the cohort operation.

99 GENERAL AND MISCELLANEOUS↗

Interactive Exploration and Analysis of Large-Scale Simulations Using Topology-Based Data Segmentation

Large-scale simulations are increasingly being used to study complex scientific and engineering phenomena. As a result, advanced visualization and data analysis are also becoming an integral part of the scientific process. Often, a key step in extracting insight from these large simulations involves the definition, extraction, and evaluation of features in the space and time coordinates of the solution. However, in many applications, these features involve a range of parameters and decisions that will affect the quality and direction of the analysis. Examples include particular level sets of a specific scalar field, or local inequalities between derived quantities. A critical step in the analysis is to understand how these arbitrary parameters/decisions impact the statistical properties of the features, since such a characterization will help to evaluate the conclusions of the analysis as a whole. We present a new topological framework that in a single-pass extracts and encodes entire families of possible features definitions as well as their statistical properties. For each time step we construct a hierarchical merge tree a highly compact, yet flexible feature representation. While this data structure is more than two orders of magnitude smaller than the raw simulation data it allows us to extract a set of features for any given parameter selection in a postprocessing step. Furthermore, we augment the trees with additional attributes making it possible to gather a large number of useful global, local, as well as conditional statistic that would otherwise be extremely difficult to compile. We also use this representation to create tracking graphs that describe the temporal evolution of the features over time. Our system provides a linked-view interface to explore the time-evolution of the graph interactively alongside the segmentation, thus making it possible to perform extensive data analysis in a very efficient manner. We demonstrate our framework by extracting and analyzing burning cells from a large-scale turbulent combustion simulation. In particular, we show how the statistical analysis enabled by our techniques provides new insight into the combustion process.

97 MATHEMATICS AND COMPUTING↗

First evaluation of the feasibility of MLC tracking using ultrasound motion estimation

Purpose: To quantify the performance of the Clarity ultrasound (US) imaging system (Elekta AB, Stockholm, Sweden) for real-time dynamic multileaf collimator (MLC) tracking. Methods: The Clarity calibration and quality assurance phantom was mounted on a motion platform moving with a periodic sine wave trajectory. The detected position of a 30 mm hypoechogenic sphere within the phantom was continuously reported via Clarity’s real-time streaming interface to an in-house tracking and delivery software and subsequently used to adapt the MLC aperture. A portal imager measured MV treatment field/MLC apertures and motion platform positions throughout each experiment to independently quantify system latency and geometric error. Based on the measured range of latency values, a prostate stereotactic body radiation therapy (SBRT) delivery was performed with three realistic motion trajectories. The dosimetric impact of system latency on MLC tracking was directly measured using a 3D dosimeter mounted on the motion platform. Results: For 2D US imaging, the overall system latency, including all delay times from the imaging and delivery chain, ranged from 392 to 424 ms depending on the lateral sector size. For 3D US imaging, the latency ranged from 566 to 1031 ms depending on the elevational sweep. The latency-corrected geometric root-mean squared error was below 0.75 mm (2D US) and below 1.75 mm (3D US). For the prostate SBRT delivery, the impact of a range of system latencies (400–1000 ms) on the MLC tracking performance was minimal in terms of gamma failure rate. Conclusions: Real-time MLC tracking based on a noninvasive US input is technologically feasible. Current system latencies are higher than those for x-ray imaging systems, but US can provide full volumetric image data and the impact of system latency was measured to be small for a prostate SBRT case when using a US-like motion input.

60 APPLIED LIFE SCIENCES↗

Scale-Dependent Fracture-Matrix Interactions and Their Impact on Radionuclide Transport: Development of efficient particle-tracking methods

Matrix Diffusion and Adsorption within a rock matrix are important mechanisms for retarding transport of radionuclides in fractured rock. Due to computational limitations and difficulties in characterizing complex subsurface systems, diffusive exchange between a fracture network and surrounding rock matrix is often modeled using simplified conceptual representations. There is significant uncertainty in “effective” parameters used in these models, such as the “effective matrix diffusivity”. Often, these parameters are estimated by fitting sparse breakthrough data, and estimated values fall outside meaningful ranges, because simplified interpretive models do not consider complex three-dimensional flow. There is limited understanding of the relationship between the effective parameters and rock mass characteristics including network structure and matrix properties. There is also evidence for an apparent scale-dependence in “effective matrix diffusion” coefficients. These observations raise questions on whether fracture-matrix interaction parameters estimated from small-scale tracer tests can be used for predicting radionuclide fate and transport at the scale of DOE field sites. High-resolution three-dimensional Discrete-Fracture-Network-Matrix (DFNM) models based on well-defined local scale transport equations can help to address some of these questions. Due to tremendous advances in computational technology over the last 10 years, DFNM modeling in relatively large domains is now feasible. The overarching objective of our research is to use DFNM modeling to improve fundamental understanding of how effective parameters in conceptual models are related to fracture network structure and matrix properties. An advanced three-dimensional DFNM model is being developed, which combines upscaled particle-tracking algorithms for fracture-matrix interaction and a parallel fracture-network flow simulator. The particle-tracking algorithms allow complexity in flow fields at different scales, and track transport across fracture-matrix interfaces based on rigorous local approximations to the transport equations. This modeling approach can incorporate aperture variability, multi-scale preferential flow and matrix heterogeneity. We developed efficient particle-tracking methods for handling matrix diffusion and adsorption on fracture walls and demonstrated their efficiency for use within the context of large-scale complex fracture network models with variability in apertures across a network of fractures and within individual fractures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-Time Drilling Optimization System for Improved Overall Rate of Penetration and Reduced Cost Per Foot in Geothermal Drilling

The key to success in geothermal drilling is economic feasibility, and a major cost in the development of geothermal resources is the actual drilling of the wells. In this project, a real-time drilling optimization system for geothermal drilling was developed. The system couples three individual components while drilling. The first component is a drill stem vibration analysis model, the second is Mechanical Specific Energy (MSE) analyses, and the third is a detailed PDC Rate of Penetration (ROP) drill bit model for optimum RPM and WOB combinations. The benefit of the coupled system is that the range of WOB and RPM could be selected to avoid drill stem vibrations. Secondly, MSE is used as an efficiency measure and the detailed PDC drill bit model ensures the drill bit does not endure temperatures that exceed the temperature at which the PDC cutters experience accelerated wear. The new detailed PDC bit model is based on rock/bit interaction that physically tracks the PDC cutter wear flats as the bit drills ahead giving the capability to calculate the temperature being generated underneath the worn cutters to better advise on operational parameters to avoid accelerated cutter wear and failure and to ensure that operational parameters are applied so that overall ROP is maximized. By combining the drill stem vibrations and the detailed PDC bit cutter wear and “safe” non-accelerated cutter wear temperature and optimum ranges of operating parameters, it results in higher ROP and lower cost drilling. Single cutter PDC testing performed in different lithologies at Sandia was utilized to verify the PDC cutter forces and depth of cut for new and worn cutters. Based on single cutter PDC temperature modeling, verification using single cutter data from the testing done by National Oilwell Varco (NOV) was performed. Sandia’s Hard-Rock Drilling Facility (HRDF) was utilized to test different drill bit configurations with different cutter designs and wear status with different induced modes of vibration to obtain the critical bit RPM/WOB ranges resulting in ineffective drilling and low ROP. The collected test data were further used to verify and calibrate the full hole PDC ROP model that was developed based on single cutter interaction data. A full coupled drill stem vibration model was formulated and verified with geothermal field data from the Chocolate Mountain Aerial Gunnery Range (CMAGR). A graphical user interface (GUI) was developed using Tkinter library in the computer programming language Python, which integrates all the developed models in one system. The developed system consists mainly of the PDC ROP model, PDC bit wear model, PDC cutter temperature model, Mechanical Specific Energy (MSE) model, and drillstring vibration model integrated into one system. The developed system can be used for both, post well analysis and real-time optimization using different criteria such as ROP maximization or MSE minimization. The software uses Differential Evolution Algorithm (DEA) to find optimum values for operational parameters based on last foot drilled while avoiding the drillstring vibration and cutter temperature critical operating parameters.

15 GEOTHERMAL ENERGY↗

WE-H-BRA-04: Biological Geometries for the Monte Carlo Simulation Toolkit TOPASNBio

Purpose: New advances in radiation therapy are most likely to come from the complex interface of physics, chemistry and biology. Computational simulations offer a powerful tool for quantitatively investigating radiation interactions with biological tissue and can thus help bridge the gap between physics and biology. The aim of TOPAS-nBio is to provide a comprehensive tool to generate advanced radiobiology simulations. Methods: TOPAS wraps and extends the Geant4 Monte Carlo (MC) simulation toolkit. TOPAS-nBio is an extension to TOPAS which utilizes the physics processes in Geant4-DNA to model biological damage from very low energy secondary electrons. Specialized cell, organelle and molecular geometries were designed for the toolkit. Results: TOPAS-nBio gives the user the capability of simulating biological geometries, ranging from the micron-scale (e.g. cells and organelles) to complex nano-scale geometries (e.g. DNA and proteins). The user interacts with TOPAS-nBio through easy-to-use input parameter files. For example, in a simple cell simulation the user can specify the cell type and size as well as the type, number and size of included organelles. For more detailed nuclear simulations, the user can specify chromosome territories containing chromatin fiber loops, the later comprised of nucleosomes on a double helix. The chromatin fibers can be arranged in simple rigid geometries or within factual globules, mimicking realistic chromosome territories. TOPAS-nBio also provides users with the capability of reading protein data bank 3D structural files to simulate radiation damage to proteins or nucleic acids e.g. histones or RNA. TOPAS-nBio has been validated by comparing results to other track structure simulation software and published experimental measurements. Conclusion: TOPAS-nBio provides users with a comprehensive MC simulation tool for radiobiological simulations, giving users without advanced programming skills the ability to design and run complex simulations.

60 APPLIED LIFE SCIENCES↗

Automated metadata, provenance cataloging and navigable interfaces: ensuring the usefulness of extreme-scale data

The MPO (Metadata, Provenance, Ontology) Project successfully addressed the goal of improving the usefulness and traceability of scientific data by building a system that could capture and display all steps in the process of creating, analyzing and disseminating that data. Throughout history, scientists have generated handwritten logbooks to keep track of data, their hypotheses, assumptions, experimental setup, and computational processes as well as reflections on observations and issues encountered. Over the last several decades, with the growth of personal computers, handheld devices, and the World Wide Web, the handwritten logbook has begun to be replaced by electronic logbooks. This transition has brought increased capability such as supporting multi-media, hypertext, and fast searching. However, content creation and metadata (a set of data that describes and gives information about other data) capturing has for the most part remained a manual activity just as it was with handwritten logbooks. This has led to a fragmentation of data, processing, and annotation that has only accelerated as scientific workflows continue to increase in complexity. From a scientific perspective, it is very important to be able to understand the lineage of any piece of data: who, what, when, how, and why. This is typically referred to as data provenance. The fragmentation discussed previously often means that data provenance is lost. As scientific workflows move to powerful computers and become more complex, the ability to track all of the steps involved in creating a piece of data become even more difficult. It was the goal of the MPO (Metadata, Provenance, Ontology) Project to create a system (the MPO System) that allows for automatic provenance and metadata capturing in such a way to allow easy searching and browsing. This goal needed to be accomplished in a general way so that it may be used across a broad range of scientific domains, yet allow the addition of vocabulary (Ontology) that is domain specific as is required for intelligent searching and browsing in the scientific context. Through the creation and deployment of the MPO system, the goals of the project were achieved. An enhanced metadata, provenance, and ontology storage system was created. This was combined with innovative methodologies for navigating and exploring these data using a web browser for both experimental and simulation-based scientific research. In addition, a system to allow scientists to instrument their existing workflows for automatic metadata and provenance is part of the MPO system. In that way, a scientist can continue to use their existing methodology yet easily document their work. Workflows and data provenance can be displayed either graphically or in an electronic notebook format and support advanced search features including via ontology. The MPO system was successfully used in both Climate and Magnetic Fusion Energy Research. The software for the MPO system is located at https://github.com/MPO-Group/MPO and is open source distributed under the Revised BSD License. A demonstration site of the MPO system is open to the public and is available at https://mpo.psfc.mit.edu/. A Docker container release of the command line client is available for public download using the command docker pull jcwright/mpo-cli at https://hub.docker.com/r/jcwright/mpo-cli.

97 MATHEMATICS AND COMPUTING↗

Integration of Online Cross-Section Generation Capability with Depletion and Transient Solvers in Griffin

Griffin is a Multiphysics Object-Oriented Simulation Environment (MOOSE)-based reactor multiphysics analysis application jointly developed by Argonne and Idaho National Laboratories under the DOENE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In FY25, an online crosssection generation capability based on the Self-Shielding Application Programming Interface (SSAPI) was demonstrated for TRISO-fueled reactor problems under steady-state conditions. This fiscal year, that capability was extended to support depletion and transient multiphysics calculations, enabling high-fidelity analyses that generate self-shielded cross sections on the fly from the actual evolving composition and temperature states rather than from pre-tabulated libraries. For depletion, a two-way coupling was established in which SSAPI computes compact-averaged self-shielded cross sections that the depletion solver then uses to advance the Bateman equations, with the updated compositions returned to SSAPI at each step; the depletion module was refactored to support both library-based and SSAPI-based cross sections, and additional logic was added to track daughter isotopes and to exclude minor isotopes for efficiency. For transient analysis, the SSAPI multigroup library was extended with the kinetics data required for time-dependent calculations, the Improved Quasi-Static (IQS) scheme was coupled with SSAPI, and several supporting capabilities were implemented, including a self-shielding treatment that lets control rods and drums move within a self-shielded model, which had previously been impossible and had ruled out rod- and drum-movement transients with on-the-fly cross sections altogether, a new mixing scheme for delayed-neutron precursor decay constants, a checkpoint-based restart workflow, and performance improvements such as pointwise cross-section interpolation and the bypassing of unnecessary Dancoff factor calculations. The implemented capabilities were verified against Serpent Monte Carlo solutions. For depletion, a prismatic pin-cell problem based on a Next Generation Nuclear Plant (NGNP) Very High Temperature Reactor benchmark showed excellent agreement, with eigenvalue differences within 200 pcm over the entire burnup range (up to 140 MWD/kgU) and fission-product and actinide inventories agreeing to within 0.8% and 2.5%, respectively; a heat-pipe microreactor assembly problem with a much higher fuel loading confirmed the same behavior and quantified the bias introduced when the multigroup equivalence effect is neglected. For transient analysis, a pin-cell problem with a step reactivity insertion and temperature feedback reproduced the analytically expected asymptotic power and showed close agreement between the direct and IQS solutions, and a two-dimensional microreactor core problem with control-drum rotation exercised the new moving-drum self-shielding treatment and demonstrated successful coupling of the online crosssection generation with both the direct and IQS transient methods. The capability was further exercised on a full-core pebble-bed problem, in which Griffin was coupled with the System Analysis Module (SAM) to simulate load-following operation of the gPBR with the Doppler feedback resolved at the TRISO fuel kernel temperature. These developments in Griffin provide a convenient, high-fidelity approach to cross-section generation for advanced thermal reactors with geometrically complex and highly heterogeneous configurations, including TRISO-fueled prismatic and pebble-bed systems, and support steady-state, depletion, and transient multiphysics calculations. They also enable self-shielded cross sections to be evaluated directly at the actual coupled state of the system, thereby establishing a foundation for high-fidelity, fully coupled multiphysics analysis of advanced reactors

Park, H.↗