Search NASA⌕ Search

SEARCH · Search NASA

Results for “rapid detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Rapid detection and quantification of impact damage in composite structures

It is shown that a multidisciplinary nondestructive evaluation approach for impact damage detection in composite structures can be used to produce a more efficient inspection. The multidisciplinary NDE approach relies on fast large area thermographic inspections along with detailed ultrasonic volumetric imaging. The thermal inspection technique rapidly identifies the impact damage. The ultrasonic volumetric imaging quantifies the impact generated delaminations through the volume of the structure.

Smith, Barry T.↗

PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores

The most common approach for assessing the abundance of viable bacterial endospores is the culture-based plating method. However, culture-based approaches are heavily biased and oftentimes incompatible with upstream sample processing strategies, which make viable cells/spores uncultivable. This shortcoming highlights the need for rapid molecular diagnostic tools to assess more accurately the abundance of viable spacecraft-associated microbiota, perhaps most importantly bacterial endospores. Propidium monoazide (PMA) has received a great deal of attention due to its ability to differentiate live, viable bacterial cells from dead ones. PMA gains access to the DNA of dead cells through compromised membranes. Once inside the cell, it intercalates and eventually covalently bonds with the double-helix structures upon photoactivation with visible light. The covalently bound DNA is significantly altered, and unavailable to downstream molecular-based manipulations and analyses. Microbiological samples can be treated with appropriate concentrations of PMA and exposed to visible light prior to undergoing total genomic DNA extraction, resulting in an extract comprised solely of DNA arising from viable cells. This ability to extract DNA selectively from living cells is extremely powerful, and bears great relevance to many microbiological arenas.

LaDuc, Myron T.↗

Rapid Detection of the Varicella Zoster Virus in Saliva

Varicella zoster virus (VZV) causes chicken pox on first exposure (usually in children), and reactivates from latency causing shingles (usually in adults). Shingles can be extremely painful, causing nerve damage, organ damage, and blindness in some cases. The virus can be life-threatening in immune-compromised individuals. The virus is very difficult to culture for diagnosis, requiring a week or longer. This invention is a rapid test for VZV from a saliva sample and can be performed in a doctor s office. The kit is small, compact, and lightweight. Detec tion is sensitive, specific, and noninvasive (no needles); only a saliva sample is required. The test provides results in minutes. The entire test is performed in a closed system, with no exposure to infectious materials. The components are made mostly of inexpensive plastic injection molded parts, many of which can be purchased off the shelf and merely assembled. All biological waste is contained for fast, efficient disposal. This innovation was made possible because of discovery of a NASA scientists flight experiment showing the presence of VZV in saliva during high stress periods and disease. This finding enables clinicians to quickly screen patients for VZV and treat the ones that show positive results with antiviral medicines. This promotes a rapid recovery, easing of pain and symptoms, and reduces chances of complications from zoster. Screening of high-risk patients could be incorporated as part of a regular physical exam. These patients include the elderly, pregnant women, and immune-compromised individuals. In these patients, VZV can be a life-threatening disease. In both high- and low-risk patients, early detection and treatment with antiviral drugs can dramatically decrease or even eliminate the clinical manifestation of disease.

Pierson, Duane L.↗

Rapid detection and quantification of impact damage in composite structures

NDE results from thermographic and volumetric ultrasonic techniques are presented to illustrate the multidisciplinary NDE approach to impact-damage detection in such composite structures as are increasingly prevalent in helicopters. Attention is given to both flat-panel and 'y-stiffened' panel specimens; these were fabricated either with kevlar or carbon fiber through-the-thickness reinforcements. While thermal inspection identifies impact damage, volumetric imaging quantifies the impact-generated delaminations through the volume of the structure.

Zalameda, Joseph N.↗

PURE mRNA display and cDNA display provide rapid detection of core epitope motif via high‐throughput sequencing

The reconstructed in vitro translation system known as the PURE system has been used in a variety of cell‐free experiments such as the expression of native and de novo proteins as well as various display methods to select for functional polypeptides. We developed a refined PURE‐based display method for the preparation of stable messenger RNA (mRNA) and complementary DNA (cDNA)‐peptide conjugates and validated its utility for in vitro selection. Our conjugate formation efficiency exceeded 40%, followed by gel purification to allow minimum carry‐over of components from the translation system to the downstream assay enabling clean and efficient random peptide sequence screening. We chose the commercially available anti‐FLAG M2 antibody as a target molecule for validation. Starting from approximately 1.7 × 10(exp 12) random sequences, a round‐by‐round high‐throughput sequencing showed clear enrichment of the FLAG epitope DYKDDD as well as revealing consensus FLAG epitope motif DYK(D/L/N)(L/Y/D/N/F)D. Enrichment of core FLAG motifs lacking one of the four key residues (DYKxxD) indicates that Tyr(Y) and Lys (K) appear as the two key residues essential for binding. Furthermore, the comparison between mRNA display and cDNA display method resulted in overall similar performance with slightly higher enrichment for mRNA display. We also show that gel purification steps in the refined PURE‐based display method improve conjugate formation efficiency and enhance the enrichment rate of FLAG epitope motifs in later rounds of selection especially for mRNA display. Overall, the generalized procedure and consistent performance of two different display methods achieved by the commercially available PURE system will be useful for future studies to explore the sequence and functional space of diverse polypeptides.

cDNA display, FLAG epitope, mRNA display, peptide ↗

Using Orbiting Carbon Observatory-2 (OCO-2) column CO2 retrievals to rapidly detect and estimate biospheric surface carbon flux anomalies

The global carbon cycle is experiencing continued perturbations via increases in atmospheric carbon concentrations, which are partly reduced by terrestrial biosphere and ocean carbon uptake. Greenhouse gas satellites have been shown to be useful in retrieving atmospheric carbon concentrations and observing surface and atmospheric CO2 seasonal-to-interannual variations. However, limited attention has been placed on using satellite column CO2 retrievals to evaluate surface CO2 fluxes from the terrestrial biosphere without advanced inversion models at low latency. Such applications could be useful to monitor, in near real time, biosphere carbon fluxes during climatic anomalies like drought, heatwaves, and floods, before more complex terrestrial biosphere model outputs and/or advanced inversion modelling estimates become available. Here, we explore the ability of Orbiting Carbon Observatory-2 (OCO-2) column-averaged dry air CO2 (XCO2) retrievals to directly detect and estimate terrestrial biosphere CO2 flux anomalies using a simple mass-balance approach. An initial global analysis of surface–atmospheric CO2 coupling and transport conditions reveals that the western US, among a handful of other regions, is a feasible candidate for using XCO2 for detecting terrestrial biosphere CO2 flux anomalies. Using the CarbonTracker model reanalysis as a test bed, we first demonstrate that a well-established mass-balance approach can estimate monthly surface CO2 flux anomalies from XCO2 enhancements in the western United States. The method is optimal when the study domain is spatially extensive enough to account for atmospheric mixing and has favorable advection conditions with contributions primarily from one background region. We find that errors in individual soundings reduce the ability of OCO-2 XCO2 to estimate more frequent, smaller surface CO2 flux anomalies. However, we find that OCO-2 XCO2 can often detect and estimate large surface flux anomalies that leave an imprint on the atmospheric CO2 concentration anomalies beyond the retrieval error/uncertainty associated with the observations. OCO-2 can thus be useful for low-latency monitoring of the monthly timing and magnitude of extreme regional terrestrial biosphere carbon anomalies.

Andrew F. Feldman↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗

Optical spectroscopic tools for standoff uranium detection

Rapid and standoff analysis of uranium is important for many applications. We present the recent advances in standoff detection of uranium using emission and laser-induced fluorescence spectroscopy in conjunction with ultrafast laser filament ablation-based solid sampling.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Rapid Event Detection via Synchro-Waveform Based Temporal Attention Network in Distributed Grid

Compared with the information collected from phasor measurement units, synchro-waveforms contain high-fidelity disturbances of the grid, which can be a granular and authentic representation of measurements in the modern power system. However, the dynamic changing morphology makes it challenging to effectively capture various disturbance information from the synchro-waveforms. To tackle this issue, this paper proposes a Synchro-waveform based Temporal Attention (STA) network to achieve rapid event detection. First, a multi-scenario distributed model with renewable integration is established to generate synchro-waveforms under various uncertainties. Then, three typical temporal features are extracted directly from the synchro-waveform measurements. Additionally, the lightweight STA network is deployed to identify the most common event types in renewable energy systems via the self-attention based vision transformer module. The results from simulated experiments demonstrate that the proposed approach can achieve rapid and real-time detection within 0.81 ms and over 96.27 % accuracy.

Dong, Yuqing [University of Tennessee (UT)]↗

RAPID STRUCTURE DETECTION IN SUPPORT OF DISASTER RESPONSE : A CASE STUDY OF THE 2018 KILAUEA VOLCANO ERUPTION

Disaster response requires timely damage assessment to prioritize rescue and restoration resources. However, providing critical and actionable knowledge after a natural disaster can be challenging due to the scale and the type of damages. This paper describes how remote sensing and machine learning techniques can be used to support rapid structure detection in the wake of a disaster. We use high resolution satellite imagery to identify structures on Hawaii’s Big Island to support the Federal Emergency Management Agency’s response efforts during the 2018 K¯ilauea lava flow incident. This framework specifically showcases the generalizability of CNN models with no need to collect additional training samples to quickly map structures in pre- and post-event imagery and provide timely information to assist government agencies evaluating the extent and potential loss of disaster. With this case study, we further point out future directions to benefit similar larger scale efforts based on the lessons learned.

Laverdiere, Melanie↗

Rapid Electrochemical Detection and Identification of Microbiological and Chemical Contaminants for Manned Spaceflight Project

Microbial control in the spacecraft environment is a daunting task, especially in the presence of human crew members. Currently, assessing the potential crew health risk associated with a microbial contamination event requires return of representative environmental samples that are analyzed in a ground-based laboratory. It is therefore not currently possible to quickly identify microbes during spaceflight. This project addresses the unmet need for spaceflight-compatible microbial identification technology. The electrochemical detection and identification platform is expected to provide a sensitive, specific, and rapid sample-to-answer capability for in-flight microbial monitoring that can distinguish between related microorganisms (pathogens and non-pathogens) as well as chemical contaminants. This will dramatically enhance our ability to monitor the spacecraft environment and the health risk to the crew. Further, the project is expected to eliminate the need for sample return while significantly reducing crew time required for detection of multiple targets. Initial work will focus on the optimization of bacterial detection and identification. The platform is designed to release nucleic acids (DNA and RNA) from microorganisms without the use of harmful chemicals. Bacterial DNA or RNA is captured by bacteria-specific probe molecules that are bound to a microelectrode, and that capture event can generate a small change in the electrical current (Lam, et al. 2012. Anal. Chem. 84(1): 21-5.). This current is measured, and a determination is made whether a given microbe is present in the sample analyzed. Chemical detection can be accomplished by directly applying a sample to the microelectrode and measuring the resulting current change. This rapid microbial and chemical detection device is designed to be a low-cost, low-power platform anticipated to be operated independently of an external power source, characteristics optimal for manned spaceflight and areas where power and computing resources are scarce.

Pierson, Duane↗