Search NASA⌕ Search

SEARCH · Search NASA

Results for “raytrace”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

CMB weak-lensing beyond the Born approximation: a numerical approach

We perform a complete study of the gravitational lensing effect beyond the Born approximation on the Cosmic Microwave Background (CMB) anisotropies using a multiple-lens raytracing technique through cosmological N-body simulations of the DEMNUni suite. The impact of second-order effects accounting for the non-linear evolution of large-scale structures is evaluated propagating for the first time the full CMB lensing jacobian together with the light rays trajectories. We carefully investigate the robustness of our approach against several numerical effects in the raytracing procedure and in the N-body simulation itself, and find no evidence of large contaminations. We discuss the impact of beyond-Born corrections on lensed CMB observables, and compare our results with recent analytical predictions that appeared in the literature, finding a good agreement, and extend these results to smaller angular scales. We measure the gravitationally-induced CMB polarization rotation that appears in the geodesic equation at second order, and compare this result with the latest analytical predictions. We then present the detection prospect of beyond-Born effects with the future CMB-S4 experiment. We show that corrections to the temperature power spectrum can be measured only if a good control of the extragalactic foregrounds is achieved. Conversely, the beyond-Born corrections on E and B-modes power spectra will be much more difficult to detect.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife

For the small radiation field sizes used in stereotactic radiosurgery, lateral electronic disequilibrium and steep dose gradients exist in a large portion of these fields, requiring the use of high-resolution measurement techniques. These relatively large areas of electronic disequilibrium make accurate dosimetry as well as dose calculation more difficult, and this is exacerbated in regions of tissue heterogeneity. Tissue heterogeneity was considered insignificant in the brain where stereotactic radiosurgery was first used. However, as this technique is expanded to the head and neck and other body sites, dose calculations need to account for dose perturbations in and beyond air cavities, lung, and bone. In a previous study we have evaluated EBT Gafchromic film (International Specialty Products, Wayne, NJ) for dosimetry and characterization of the Cyberknife radiation beams and found that it was comparable to other common detectors used for small photon beams in solid water equivalent phantoms. In the present work EBT film is used to measure dose in heterogeneous slab phantoms containing lung and bone equivalent materials for the 6 MV radiation beams of diameter 7.5 to 40 mm produced by the Cyberknife (Accuray, Sunnyvale, CA). These measurements are compared to calculations done with both the clinically utilized Raytrace algorithm as well as the newly developed Monte Carlo based algorithm available on the Cyberknife treatment planning system. Within the low density material both the measurements and Monte Carlo calculations correctly model the decrease in dose produced by a loss of electronic equilibrium, whereas the Raytrace algorithm incorrectly predicts an enhancement of dose in this region. Beyond the low density material an enhancement of dose is correctly calculated by both algorithms. Within the high density bone heterogeneity the EBT film measurements represent dose to unit density tissue in bone and agree with the Monte Carlo results when corrected to dose to unit density tissue in bone. We conclude that EBT film is an appropriate dosimeter for measuring dose in heterogeneous materials and these measurements agree with Monte Carlo calculations of dose as implemented in the Cyberknife treatment planning system.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Effect of Ionospheric Models on Electromagnetic Pulse Locations

Locations of electromagnetic pulses (EMPs) determined by time-of-arrival (TOA) often have outliers with significantly larger errors than expected. In the past, these errors were thought to arise from high order terms in the Appleton-Hartree equation. We simulated 1000 events randomly spread around the Earth into a constellation of 22 GPS satellites. We used four different ionospheres: “simple” where the time delay goes as the inverse of the frequency-squared, “full Appleton-Hartree”, the “BobRD integrals” and a full raytracing code. The simple and full Appleton-Hartree ionospheres do not show outliers whereas the BobRD and raytracing do. This strongly suggests that the cause of the outliers is not additional terms in the Appleton-Hartree equation, but rather is due to the additional path length due to refraction. A method to fix the outliers is suggested based on fitting a time to the delays calculated at the 5 GPS frequencies with BobRD and simple ionospheres. The difference in time is used as a correction to the TOAs.

58 GEOSCIENCES↗

Speed Optimizations for Physics Ray Trace Algorithms

Ray tracing is a process used commonly in computer graphics and in physics to track light photons and particles, respectively. Much research was found on improving execution times for the computer graphics applications; however, in the short time frame of this literary review, almost no research was found on improving the execution times for the physics applications that were relevant to this problem. Two ray trace algorithms, a STL raytrace and a conebeam raytrace, were optimized using OpenMP and CUDA.

97 MATHEMATICS AND COMPUTING↗

xicsrt

XICSRT is a general purpose, photon based, raytracing code intended for both optical and x-ray raytracing.

Pablant, NovimirAntoniuk [Princeton Plasma Physics↗

A linked-scale coupled model of mass erosion and redistribution in plasma-exposed micro-foam surfaces

Surface evolution due to exposure to harsh environments is of importance in many scientific and technological applications. In plasma-exposed materials, the surface receives charged particles from the plasma, leading to a series of processes that drive the system far from equilibrium and may lead to the severe deterioration of the surface properties. Although surface morphological changes are driven by atomic collisions taking place over picoseconds and nanometers, these processes result in mass loss and redistribution of matter over much larger length and time scales. This necessitates a multi-scale approach capable of capturing the range of processes linking primary atomic collision events with engineering-level surface geometry changes. In this paper, we develop a computational model to simulate the morphological evolution and effective erosion rate of micro-architected tungsten foams during low-energy plasma ion bombardment. Furthermore, the model acts on several length scales, with the energy and angular dependence of the sputtering yield of flat tungsten surfaces determined using the SRIM code based on the binary collision approximation. This information is introduced into a low-fluence, short-term Monte Carlo raytracing model, and further into a high-fluence, long-term particle transport model. In the latter, material particles representing billions of atoms are described in a digitized 3-D representation of the foam structure from X-ray tomography data, and are sputtered off and redeposited using the atomistic information. We show that the redeposition of sputtered atoms leads to partial self-healing in the bottom layers with a sharp reduction in the sputtering coefficient of low density foams, roughly 25% of the solid W value. This is in qualitative agreement with recent experiments on low porosity W structures. At high fluence, the foam structure degrades considerably as there are fewer ligaments available to recapture sputtered atoms and, consequently, the sputtering rate increases again.

36 MATERIALS SCIENCE↗

Light-scattering properties of a Venetian blind slat used for daylighting applications

The low cost, simplicity, and aesthetic appearance of external and internal shading devices, make them commonly used for daylighting and glare-control applications. Shading devices, such as Venetian blinds, screens, and roller shades, generally exhibit light scattering and/or light redirecting properties. This requires the bi-directional scattering distribution function (BSDF) of the material to be known in order to accurately predict the daylight distribution and energy flow through the fenestration system. Acquiring the complete BSDF is not a straightforward task, and to complete the process it is often required that a model is used to complement the measured data. In this project, a Venetian blind slat with a white top surface and a brushed aluminum bottom surface was optically characterized. A goniophotometer and an integrating sphere spectrophotometer were used to determine the angle resolved and hemispherical reflectance of the sample, respectively. The acquired data were fitted to a scattering model providing one Lambertian and one angle dependent description of the surface properties. These were used in combination with raytracing to obtain the complete BSDFs of the Venetian blind system. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field validation of data-driven BSDF and peak extraction models for light-scattering fabric shades

Shading and daylighting systems affect cooling, heating, and lighting energy use by modulating solar radiation through the building façade. Characterizing shading systems holistically and accurately helps designers and engineers evaluate shading systems to achieve energy and non-energy performance goals. These complex fenestration systems can be modeled using Bidirectional Scattering Distribution Functions (BSDF), which map incident radiation to hemispherical distributions of outgoing radiation. Data-driven, tabulated BSDFs are derived from interpolated goniophotometer measured data, then sampled during the raytracing calculation. A peak extraction (PE) algorithm was developed to circumvent limits in BSDF angular resolution, where the specular peak is extracted during simulation by evaluating the BSDF in the through direction and surrounding region. The objective of this study was to validate this measurement and modeling workflow using field monitored data from a full scale testbed with eleven installed fabrics of different weaves, openness factors, and colors and assess the accuracy of the workflow under different adaptation and contrast conditions. Test conditions were limited to clear sky conditions with the sun in the field of view. Results showed that, for tensor tree datasets, vertical illuminance, solar luminance (2.5° apex), and daylight glare probability (DGP) were predicted to within a mean bias error (MBE) error of -456 lx (-12.3%), -3.46e5 (-38.4%), and -0.042 (-7.8%) when full PE occurred. With a binary classification of glare/ no glare, DGP was predicted accurately with a true positive rate of 0.98 and true negative rate of 1.0 using tensor tree data and less accurately with Klems BSDF data, particularly for cases of no glare. The workflow may be of insufficient accuracy to distinguish borderline performance between fabrics using the four-point glare scale, particularly under low adaptation, high contrast daylit conditions. Errors were due to reductions in peak shape and intensity across the BSDF interpolation and data reduction workflow. Future work is needed to better preserve measurement fidelity during interpolation and sampling, which in turn will improve PE performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computation of magnetic fields from field components on a plane grid

An algorithm is presented to calculate the field components of the magnetic field [B x (x, y, z), B y (x, y, z), B z (x, y, z)] at a point (x, y, z) in space, from the knowledge of the components [B x (x, y) = 0, z), B y (x, y = 0, z), B z (x, y = 0,z)] on a “reference plane”, which is normal to the y-axis at . The algorithm, which is a general one and is not restricted to fields with mid-plane symmetry is based on the Maclaurin series expansion of the magnetic field components at any point in space in terms of the distance (y) of the point from the reference plane. The coefficients of the Maclaurin series expansion are expressed in terms of the on-plane field components and their partial derivatives with respect to spatial coordinates (). The field components are usually generated from magnetic field measurements on a rectangular grid on the plane. This algorithm was employed in 1986 in the RAYTRACE computer code to help calculate the optical properties of magnets and of the Alternating Gradient Synchrotron (AGS) at the Brookhaven National Laboratory (BNL). Here, a general mathematical formulation of this algorithm based on the differential algebraic method was presented by Makino in 2011. This paper presents the step by step derivation of the algorithm and provides the necessary formulas to be introduced by the reader in any computer code which requires the field components generated by magnetic devices. In addition provides an example of the use of the algorithm and its limitations as applied to a Halbach type magnet with or without median plane symmetry.

43 PARTICLE ACCELERATORS↗

Predicting image blur in proton radiography: comparisons between measurements and Monte Carlo simulations

Given the cost and lead-times involved in high-energy proton radiography, it is prudent to model proposed radiographic experiments to see if the images predicted would return useful information. We recently modified our raytracing transmission radiography modeling code HADES to perform simplified Monte Carlo simulations of the transport of protons in a proton radiography beamline. Beamline objects include the initial diffuser, vacuum magnetic fields, windows, angle-selecting collimators, and objects described as distorted 2D (planar or cylindrical) meshes or as distorted 3D hexahedral meshes. We present an overview of the algorithms used for the modeling and code timings for simulations through typical 2D and 3D meshes. We next calculate expected changes in image blur as scattering materials are placed upstream and downstream of a resolution test object (a 3 mm thick sheet of tantalum, into which 0.4 mm wide slits have been cut), and as the current supplied to the focusing magnets is varied. We compare and contrast the resulting simulations with the results of measurements obtained at the 800 MeV Los Alamos LANSCE Line-C proton radiography facility.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Aberration-Free Imaging for Light and Electrons

The equations for refraction of either the extraordinary wave of light or the wavefunction of an electron at a planar boundary between two misoriented uniaxially anisotropic materials are shown via raytracing to yield a transverse displacement of the object point. The displacement is independent of ray incidence angle and is thus free from spherical aberration, yielding a perfect virtual image which can have applications in birefringent optics. The general conditions for this aberration-free imaging are found to be identical to those required for amphoteric total refraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Refraction-enhanced x-ray radiography for inertial confinement fusion and laser-produced plasma applications

We explore various laser-produced plasma and inertial confinement fusion applications of phase-contrast x-ray radiography, and we show how the main features of these enhancements can be considered from a geometrical optics perspective as refraction enhancements. This perspective simplifies the analysis and often permits simple analytical formulas to be derived that predict the enhancements. We explore a raytrace approach to various material interface applications, and we explore a more general example of refractive bending of x rays by an implosion plasma. We find that refraction-enhanced x-ray radiography of implosions may provide a means to quantify density differences across shock fronts as well as density variations caused by local heating due to high-Z dopants. We also point out that refractive bending by implosions plasmas can blur fine radiograph features and can also provide misleading contrast information on area-backlit pinhole imaging experiments unless its effects are taken into consideration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution spectroscopy for Doppler-broadening ion temperature measurements of implosions at the National Ignition Facility

Future implosion experiments at the national ignition facility (NIF) will endeavor to simultaneously measure electron and ion temperatures with temporal and spatial resolution in order to explore non-equilibrium temperature distributions and their relaxation toward equilibrium. In anticipation of these experiments, and with understanding of the constraints of the NIF facility environment, we have explored the use of Doppler broadening of mid-Z dopant emission lines, such as krypton He-{alpha} at 13 keV, as a diagnostic of time- and potentially space-resolved ion temperature. We have investigated a number of options analytically and with numerical raytracing, and we have identified several promising candidate spectrometer designs that meet the expected requirements of spectral and temporal resolution and data signal-to-noise ratio for gas-filled exploding pusher implosions, while providing maximum flexibility for use on a variety of experiments that potentially include burning plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance and data analysis aspects of the new DIII-D monostatic profile reflectometer system

A new frequency-modulated profile reflectometer system, featuring a monostatic antenna geometry (using one microwave antenna for both launch and receive), has been installed on the DIII-D tokamak, providing a first experimental test of this measurement approach for profile reflectometry. Significant features of the new system are briefly described in this paper, including the new monostatic arrangement, use of overmoded, broadband transmission waveguide, and dual-polarization combination/demultiplexing. Updated data processing and analysis, and in-service performance aspects of the new monostatic profile reflectometer system are also presented. By using a raytracing code (GENRAY) to determine the approximate trajectory of the probe beam, the electron density (n{sub e}) profile can be successfully reconstructed with L-mode plasmas vertically shifted by more than 10 cm off the vessel midplane. Specifically, it is demonstrated that the new system has a capability to measure n{sub e} profiles with plasma vertical offsets of up to ±17 cm. Examples are also presented of accurate, high time and spatial resolution density profile measurements made over a wide range of DIII-D conditions, e.g., the measured temporal evolution of the density profile across a L-H transition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light propagation in a neutron detector based on 6 Li glass scintillator particles in an organic matrix

Composite materials consisting of 6 Li scintillator particles in an organic matrix can enable thermal neutron detectors with excellent rejection of gamma-ray backgrounds. The efficiency of transporting scintillation light through such a composite is critical to the detector performance. This optical raytracing study of a composite thermal neutron detector quantifies the various sources of scintillation light loss and identifies favorable photomultiplier tube (PMT) readout schemes. The composite material consisted of scintillator cubes within an organic matrix shaped as a right cylinder. The cylinder surface was surrounded by an optical reflector, and the light was detected by PMTs attached to the cylinder end faces. A reflector in direct contact with the composite caused 53% loss of scintillation light. This loss was reduced 8-fold by creating an air gap between the composite and the reflector to allow a fraction of the scintillation light to propagate by total internal reflection. Replacing a liquid mineral oil matrix with a solid acrylic matrix decreased the light transport efficiency by only ~10% for the benefit of creating an all-solid-state device. The light propagation loss was found to scale exponentially with the distance between the scintillation event and the PMT along the cylinder main axis. This enabled a PMT readout scheme that corrects for light propagation loss on an event-by-event basis and achieved a 4.0% energy resolution that approached Poisson-limited performance. These results demonstrate that composite materials can enable practical thermal neutron detectors for a wide range of nuclear non-proliferation and safeguard applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid particle-in-cell simulations of laser-driven plasma interpenetration, heating, and entrainment

Kinetic-ion, quasineutral, fluid-electron particle-in-cell simulations of interpenetrating carbon–carbon plasma flows in 2D RZ cylindrical geometry are presented. The simulations are initialized with solid density targets that are subsequently irradiated by 10 14 W/cm 2 intensity lasers using a raytracing package. The ablation, interpenetration, heating, slowing, entrainment, and stagnation of the plasma flows evolve self-consistently within the code. The particle density, velocity phase space, and fits to the velocity distribution functions are used, along with analytical collisional stopping rates, to interpret the dynamics of the flow evolution. Comparisons to multifluid simulations are described and used to highlight ion-kinetic effects in the setup. Synthetic Thomson scattering diagnostic signals are generated using detailed knowledge of the plasma distribution functions. The large scale of the system, 1 × 1 mm for 2 ns, and the detailed dynamics extracted demonstrate that such hybrid codes are powerful tools for the design and evaluation of laboratory-scale high-energy-density plasma physics experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MPRAD: A Monte Carlo and ray-tracing code for the proton radiography in high-energy-density plasma experiments

Proton radiography is used in various high-energy-density (HED) plasma experiments. In this paper, we describe a Monte Carlo and raytracing simulation tool called multimegaelectronvolt proton radiography (MPRAD) that can be used for modeling the deflection of proton beams in arbitrary three dimensional electromagnetic fields as well as the diffusion of the proton beams by Coulomb scattering and stopping power. Specifically, the Coulomb scattering and stopping power models in cold matter and fully ionized plasma are combined using interpolation. We discuss the application of MPRAD in a few setups relevant to HED plasma experiments where the plasma density can play a role in diffusing the proton beams and affecting the prediction and interpretation of the proton images. It is shown how the diffusion due to plasma density can affect the resolution and dynamical range of the proton radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition Facility

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L 3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

47 OTHER INSTRUMENTATION↗