Search NASA⌕ Search

SEARCH · Search NASA

Results for “reconditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design, development, performance, and reconditioning of Ni-Cd batteries using polyropylene separators

A performance assessment is made for the Viking Mars Lander Program's sealed, sterilizable, 8-ampere hour Ni-Cd batteries, which use a nonwoven polypropylene separator material. Attention is given to separator wettability, the optimization of electrolyte quantity, and the reduction of plate carbonate, in view of thermal considerations and other environmental design and test requirements generated by mission characteristics. Life data based on mission experience identify, in addition to performance and degradation behavior, a series of shallow discharge reconditioning cycles and an intensive program of deep discharge reconditioning.

Britting, A. O., Jr.↗

The In-Orbit Battery Reconditioning Experience On Board the Orion 1 Spacecraft

The Orion 1 spacecraft is a three-axis stabilized geostationary earth orbiting commercial communications satellite which was launched on November 29, 1994 aboard an Atlas II launch vehicle. The power subsystem is a dual bus, dual battery semi-regulated system with one 78 Ampere-hour nickel-hydrogen battery per bus. The batteries were built and tested by Eagle Picher Industries, Inc., of Joplin, MO and were integrated into the spacecraft by its manufacturer, Matra Marconi Space UK Ltd. This paper presents the results obtained during the first four in-orbit reconditioning cycles and compares the battery performance to ground test data. In addition, the on-station battery management strategy and implementation constraints are described. Battery performance has been nominal throughout each reconditioning cycle and subsequent eclipse season.

Hoover, S. A.↗

NASA Musculoskeletal Space Medicine and Reconditioning Program

The Astronaut Strength, Conditioning, and Rehabilitation (ASCR) group is comprised of certified strength and conditioning coaches and licensed and certified athletic trainers. The ASCR group works within NASA s Space Medicine Division providing direction and supervision to the astronaut corp with regards to physical readiness throughout all phases of space flight. The ASCR group is overseen by flight surgeons with specialized training in sports medicine or physical medicine and rehabilitation. The goals of the ASCR group include 1) designing and administering strength and conditioning programs that maximize the potential for physical performance while minimizing the rate of injury, 2) providing appropriate injury management and rehabilitation services, 3) collaborating with medical, research, engineering, and mission operations groups to develop and implement safe and effective in-flight exercise countermeasures, and 4) providing a structured, individualized post-flight reconditioning program for long duration crew members. This Panel will present the current approach to the management of musculoskeletal injuries commonly seen within the astronaut corp and will present an overview of the pre-flight physical training, in-flight exercise countermeasures, and post-flight reconditioning program for ISS astronauts.

Kerstman, Eric↗

AN Fitting Reconditioning Tool

A tool was developed to repair or replace AN fittings on the shuttle external tank (ET). (The AN thread is a type of fitting used to connect flexible hoses and rigid metal tubing that carry fluid. It is a U.S. military-derived specification agreed upon by the Army and Navy, hence AN.) The tool is used on a drill and is guided by a pilot shaft that follows the inside bore. The cutting edge of the tool is a standard-size replaceable insert. In the typical Post Launch Maintenance/Repair process for the AN fittings, the six fittings are removed from the ET's GUCP (ground umbilical carrier plate) for reconditioning. The fittings are inspected for damage to the sealing surface per standard operations maintenance instructions. When damage is found on the sealing surface, the condition is documented. A new AN reconditioning tool is set up to cut and remove the surface damage. It is then inspected to verify the fitting still meets drawing requirements. The tool features a cone-shaped interior at 36.5 , and may be adjusted at a precise angle with go-no-go gauges to insure that the cutting edge could be adjusted as it wore down. One tool, one setting block, and one go-no-go gauge were fabricated. At the time of this reporting, the tool has reconditioned/returned to spec 36 AN fittings with 100-percent success of no leakage. This tool provides a quick solution to repair a leaky AN fitting. The tool could easily be modified with different-sized pilot shafts to different-sized fittings.

Lopez, Jason↗

Performance of battery reconditioning on the communications technology satellite

Some real life data on the flight performance and reconditioning on the Communications Technology Satellite are presented. There are two 24-cell nominal 5 amp-hour nickel cadmium batteries on board. The two batteries are operated in parallel with isolating diodes in between and permanently connected to the housekeeping buses. The recharge can be at C over 10 or C over 20 to a 1.4 charge/discharge ratio; and recharge is terminated either when a computed 1.4 charge/discharge ratio is reached, or a charge voltage peak is reached.

Lackner, J.↗

Reconditioning on SATCOM

A brief history of the SATCOM satellites is given. Cell design and battery operating characteristics are outlined and discussed. Graphs are presented comparing reconditioning parameters such as voltage, temperature, time and discharge.

Napoli, J.↗

Battery reconditioning, summary of TRW experience

The data collected from the results of battery reconditioning accumulated from three different spacecraft programs are summarized. The basic design characteristics of the programs are also presented.

Scott, W. R.↗

NiCd cell reversals during reconditioning

An accelerated battery test with 15 periods of cell reversals during reconditioning was performed. The nature and extent of hydrogen generation was examined, and the effects of reversals on battery performance were determined.

Hwang, W.↗

Deconditioning and Reconditioning: Humans in Stressful Environments

Deconditioning is an integrated physiological response of the body to a reduction in metabolic rate; that is, to a reduction in energy use or in exercise level. While it may involve assumption of a horizontal body position, it certainly perturbs bodily homeostasis - at least temporarily. The reduction in physical activity that causes deconditioning is often associated with an increase in the time spent, for whatever reason, in a sitting or horizontal position. As a result, orthostatic factors may also contribute to the deconditioning mechanism. The word decondition may be defined as "1: to cause extinction of (a conditioned response) 2: to cause to lose physical fitness". This definition implies that psychological/emotional factors may accompany physical deconditioning, and it is this interpretation of the word that is used throughout this volume. It is apparent that deconditioning plays a major role in the mechanism of the general adaptive (homeostatic) response that is initiated by exposure to prolonged bed rest (BR). And the total homeostatic response to BR involves more than deconditioning per se. For example, it has been shown that the restoration of plasma volume and maximal work capacity after 4 weeks of BR deconditioning left other bodily functions (submaximal exercise oxygen uptake and cardiac output, leg proprioception and posterior leg muscle thickness and volume, head-up tilt tolerance, and sleep quality) functioning at decreased levels. The precise effect of deconditioning on BR homeostasis is difficult to determine, because the fundamental interactive neuro-endocrine-immune control networks that facilitate conditioning and deconditioning also act to maintain basic wholebody homeostasis. For example, is the mechanism of BR-induced deconditioning independent of the mechanism that provokes concomitant orthostatic intolerance; that is, fainting? Assumption of the recumbent body position for prolonged periods of time, results in a new adaptive-homeostatic state. This state occurs in response to the mutually interactive effects of the change in bodily position (hydrostatic pressure), to the virtual elimination of longitudinal pressure on the bones, to the increased confinement with possible reduction in total daily energy (exercise) expenditure, to the reorientation of stimuli within the vestibular organs, and (often) to altered socio-psychological conditions. The exercise-training (reconditioning) syndrome affects total body homeostasis by facilitating increases in work capacity and endurance, whereas deconditioning decreases physical performance. There are many interrelated factors that influence the control parameters that seek to maintain the adaptive conditioning-deconditioning syndrome. These control parameters can be better elucidated by subjecting otherwise healthy ambulatory people to various stresses, such as exercise training and prolonged spaceflight, bed rest, water immersion, hyperbaria, and isolation and confinement. Changes in control parameters will be manifested in muscle function, orthostatic tolerance, cardiorespiratory responses, musculo-skeletal systems, free-radical processes, and body thermoregulation with overarching effects on the subjects' psycho-sociological states. A discussion of these factors and the control parameters constitutes the substance of this volume. Special emphasis is placed on delineating practical applications of the findings that will be of special interest to physicians, nurses, and other health-care workers.

Greenleaf, John E.↗

Musculoskeletal Injuries in US Astronauts: Injury Prevention Strategies, Including Pre-Flight EVA Fitness Training, Return to Flight Following Injuries, and Post-Flight Reconditioning

Outline: Background; Terrestrial experience -Initial investigation into MSK (MusculoSKeletal) injuries -MSK Medicine Program -Training injuries -NBL (Neutral Buoyancy Laboratory) EMU (Extravehicular activity Mobility Unit) Work Hardening Program -Return to duty -Post-flight reconditioning program; Inflight musculoskeletal conditions; Lunar Surface Operations; Post-flight injuries.

Scheuring, Richard A.↗

Standing Without Gravity: the Use of Lower Body Negative Pressure for Research and Reconditioning in Spaceflight

Weightlessness during spaceflight causes cephalad redistribution of intravascular and extravascular fluid, provoking cardiovascular and autonomic nervous system adaptations. The resulting functional state is appropriate for weightlessness but can result in orthostatic hypotension and intolerance during and after return to a persistent acceleration or gravitational environment. Lower body negative pressure (LBNP) applies subambient air pressure to the legs and lower abdomen inside a volume sealed at the waist, and decompression by 40‐50 mmHg reverses the spaceflight‐induced cephalad shift. LBNP has been used both to test the state of cardiovascular system during spaceflight and as a countermeasure by all space‐faring nations. Two configurations have thus far been used in spaceflight since the first LBNP flew on the first Soviet Salyut station in 1971. The Soviet and Russian configuration, used in four Salyut stations, the Mir space station and the Russian segment of the International Space Station, has no saddle to support the body so during decompression the feet press against the bottom of the collapsible chamber which shortens and applies force against the feet proportional to the decompression level. Thus, activation of the skeletal musculature partially counteracts vascular and venous pooling in the enclosed body segments, stimulating the orthostatic compensatory mechanisms as they would be standing on Earth. In the American configuration, used aboard Skylab and the Space Shuttle, a saddle supported the astronaut so the feet did not contact the bottom of the chamber, and vascular engorgement was not countered by muscular contraction. This minimized skeletal muscle involvement, unmasked vascular compensatory mechanisms for research purposes, and allowed measurements of changes in leg volume and muscle sympathetic nerve activity. Both variants have demonstrated research and therapeutic value in appropriately designed protocols. LBNP continues to be used for research and countermeasures on ISS, and future versions may explore the value of exercise during LBNP as an integrated countermeasure. This paperwill review the history and development of LBNP for spaceflight research and therapeutic purposes.

Charles, John B.↗

The characteristics of sealed nickel-cadmium cells during voltage reversal

A mechanism which allows a cell voltage reversal in a nickel cadmium battery are discussed. The effects of reconditioning and the characteristics of Ni-Cd cells during voltage reversal at low overdischarge rates are outlined. Graphs are presented for: (1) hydrogen pressure decay-effect of state of charge (open circuit stand); (2) hydrogen pressure increase during overdischarge; (3) hydrogen pressure decay-effect of temperature (cells terminals connected through resistors); (4) cell, positive and negative electrode voltage during reversal when reconditioning a 13 cell-24-Ah battery pack through a 40 Omega resistor; (5) pressure discharge current and recombination current during voltage reversal when reconditioning a 13 cell-24-Ah battery pack through a 40 Omega resistor; (6) theoretical hydrogen gas pressure if there were no recombination; and (7) effect of hydrogen pressure on recombination rate during overcharge.

Ritterman, P. F.↗

GPS on-orbit battery performance

Three batteries designed for the GPS system were evaluated. The batteries were wired together, and during the eclipse period were discharged through parallel diodes into a boost converter which then boosted the battery voltage up to the totally regulated bus voltage. Each battery, with a system life of approximately five years, had its own charger. During testing the battery was maintained or used on trickle charge. Data are presented for the battery capacity during the reconditioning. Raw data for each eclipse period and calculations for the average discharge voltage for each battery are given. Thermal cycling for one of the batteries and reconditioning cycles and regimes for all of the batteries are discussed. A reconditioning discharge curve is also given. The problem of temperature cycling in one of the batteries was resolved by redesigning the battery radiator system.

Kasten, J. L.↗

Cognitive Functioning in Long Duration Head-down Bed Rest

The Space Flight Cognitive Assessment Tool for Windows (WinSCAT) is a self-administered battery of tests used on the International Space Station for evaluating cognitive functioning. Here, WinSCAT was used to assess cognitive functioning during extended head-down bed rest. Thirteen subjects who participated in 60 or 90 days of 6 deg head-down bed rest took WinSCAT during the pre-bed rest phase, the in-bed rest phase, and the post-bed rest (reconditioning) phase of study participation. After adjusting for individual baseline performance, 12 off-nominal scores were observed out of 351 total observations during bed rest and 7 of 180 during reconditioning. No evidence was found for systematic changes in off-nominal incidence as time in bed rest progressed, or during the reconditioning period. Cognitive functioning does not appear to be adversely affected by long duration head-down bed rest. Individual differences in underlying cognitive ability and motivation level are likely explanations for the current findings.

Seaton, Kimberly A.↗