Comparison of Pyranometers and Reference Cells on Fixed and One-axis Tracking Surfaces

Photovoltaic (PV) system perfomance is monitored by a wide variety of sensors. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile-based pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface, a fixed-tilt surface, and a one-axis tracking surface. This analysis focuses on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles-of-incidence even though both instruments are based on measuring the short circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded- base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer that has a response nearly independent of the wavelength of light used by PV modules.

14 SOLAR ENERGY↗

Comparison of Pyranometers and Reference Cells on Fixed and One-Axis Tracking Surfaces: Preprint

A wide variety of sensors are used to monitor the irradiance incident on solar modules to evaluate the performance of photovoltaic (PV) systems. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules, a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface, a fixed-tilt surface, and a one-axis tracking surface. This analysis focuses on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles of incidence, even though both instruments are based on measuring the short-circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded-base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer, which has a response nearly independent of the wavelength of light used by PV modules.

14 SOLAR ENERGY↗

Evaluation of Solar Reference Cells on a Two-Axis Tracker Using Spectral Measurements

A simple model calculating the performance of an IMT solar reference cell is proposed and tested under clear sky periods. One-minute data from EKO spectroradiometers collocated with an IMT reference cell are used for the analysis. Data are obtained at the NREL Solar Radiation Research Laboratory in Golden, Colorado and the UO Solar Radiation Monitoring Laboratory in Eugene, Oregon. The model is also applied and evaluated under cloudy conditions. A match of better than 1% is found between calculated clear sky values and IMT measurements for July, 2020. One- minute cloudy sky comparisons show a much larger variation, but when averaged over one hour, a standard deviation of 4% between the calculated and measured values is found.

atmospheric radiation↗

Compact and Robust Refilling and Connectorization of Hollow Core Photonic Crystal Fiber Gas Reference Cells

This slide presentation reviews a method for refilling and connectorization of hollow core photonic crystal fiber gas reference cells. Thees hollow-core photonic crystal fiber allow optical propagation in air or vacuum and are for use as gas reference cell is proposed and demonstrated. It relies on torch-sealing a quartz filling tube connected to a mechanical splice between regular and hollow-core fibers.

hollow core fiber↗

Pyranometers and Reference Cells: Part 2: What Makes the Most Sense for PV Power Plants?

As described in Part 1 of this two-part series, thermopile pyranometers and photovoltaic (PV) reference cells can both be used to measure irradiance; however, there are subtle differences between the data that are obtained. This two-part article explores some implications of uncertainty and subtleties of accurately measuring PV efficiency in the field. Part 2 of the series shows how reference cells can be used to more confidently predict PV performance, but how this could best be accomplished if historic irradiance data could be available in PV-technology-specific formats.

14 SOLAR ENERGY↗

Improved Field Evaluation of Reference Cell Using Spectral Measurements: Preprint

Spectral irradiance measurements as opposed to modeled spectral values are used to evaluate the effects of changing spectral distributions on the output of reference solar cells. Comparisons are made on a one-axis tracking surface to a Class A pyranometer. The ratio of the reference cells to reference pyranometers exhibit a bias over the day. Spectral and temperature modeling reproduce most but not all changes in the ratio over the day. Sources for this difference in modeling and performance of the reference cells are examined.

14 SOLAR ENERGY↗

Structural variant analysis of a cancer reference cell line sample using multiple sequencing technologies

The cancer genome is commonly altered with thousands of structural rearrangements including insertions, deletions, translocation, inversions, duplications, and copy number variations. Thus, structural variant (SV) characterization plays a paramount role in cancer target identification, oncology diagnostics, and personalized medicine. As part of the SEQC2 Consortium effort, the present study established and evaluated a consensus SV call set using a breast cancer reference cell line and matched normal control derived from the same donor, which were used in our companion benchmarking studies as reference samples. We systematically investigated somatic SVs in the reference cancer cell line by comparing to a matched normal cell line using multiple NGS platforms including Illumina short-read, 10X Genomics linked reads, PacBio long reads, Oxford Nanopore long reads, and high-throughput chromosome conformation capture (Hi-C). We established a consensus SV call set of a total of 1788 SVs including 717 deletions, 230 duplications, 551 insertions, 133 inversions, 146 translocations, and 11 breakends for the reference cancer cell line. To independently evaluate and cross-validate the accuracy of our consensus SV call set, we used orthogonal methods including PCR-based validation, Affymetrix arrays, Bionano optical mapping, and identification of fusion genes detected from RNA-seq. We evaluated the strengths and weaknesses of each NGS technology for SV determination, and our findings provide an actionable guide to improve cancer genome SV detection sensitivity and accuracy. A high-confidence consensus SV call set was established for the reference cancer cell line. A large subset of the variants identified was validated by multiple orthogonal methods.

59 BASIC BIOLOGICAL SCIENCES↗

Laser Frequency Stabilization for Coherent Lidar Applications using Novel All-Fiber Gas Reference Cell Fabrication Technique

Compact hollow-core photonic crystal fiber (HC-PCF)gas frequency reference cell was constructed using a novel packaging technique that relies on torch-sealing a quartz filling tube connected to a mechanical splice between regular and hollow-core fibers. The use of this gas cell for laser frequency stabilization was demonstrated by locking a tunable diode laser to the center of the P9 line from the (nu)1+(nu)3 band of acetylene with RMS frequency error of 2.06 MHz over 2 hours. This effort was performed in support of a task to miniaturize the laser frequency stabilization subsystem of JPL/LMCT Laser Absorption Spectrometer (LAS) instrument.

Laser Absorption Spectrometer (LAS)↗

Fourier Transform Infrared Spectroscopy of CF4 on the GEC Reference Cell

Fourier Transform Infrared Spectroscopy (FTIR) has been used to characterize inductively coupled CF4 plasmas in a GEC Reference Cell in-situ In examining these FTIR spectra, several assumptions and approximations of FTIR analysis are addressed. This includes the density dependence of cross-sections, non-linear effects in the addition of overlapping bands and the effect of spatial variations in density and temperature, This analysis demonstrates that temperatures extracted from MR spectra may provide a poor estimate of the true neutral plasma temperature. The FTIR spectra are dominated by unreacted CF, accounting for 40-60% of the gas products. The amount of CF4 consumption is found to have a marked dependence on power, and is nearly independent of pressure in the range of 10-50 mtorr. Small amounts of C2F6 are observed at low power. Also observed are etching products from the quartz window SiF4 COF2 and CO which occur in approximately equal ratios and together account for less than 10% of the gas. The concentrations of these species are nearly independent of pressure. CFx radicals are below the detection limit of this apparatus (approx. 1012/cc).

Rao, M. V. V. S.↗

Primary reference cell calibrations at SERI - History and methods

The tabular calibration method used at the Solar Energy Research Institute (SERI) for primary reference cells is derived and described in detail. An uncertainty analysis shows that the tabular method should have a total uncertainty of + or - 1.0 percent; data from five years of calibrations are then shown to support this analysis. Results from SERI's tabular method are compared with terrestrial calibrations performed by the NASA Lewis Research Center in the late 1970s.

Osterwald, C. R.↗

Langmuir Probe Measurements in an Inductively Coupled GEC Reference Cell Plasma

Measurements of electron number density, electron temperature, and electron energy distribution function (EEDF) using a compensated Langmuir probe have been performed on an inductively (transformer ) coupled Gaseous Electronics Conference (GEC) reference cell plasma. The plasma source is operated with CH4, CF4, or their mixtures with argon. The effect of independently driving the electrode supporting the wafer on the probe data is studied. In particular, we find that the plasma structure depends on the phase in addition to the magnitude of the power coupled to the electrode relative to that of the transformer coil. The Langmuir probe is translated in a plane parallel to the electrode to investigate the spatial structure of the plasma. The probe data is also compared with fluid model predictions.

Ji, J. S.↗

Reference-cell calibration activities

The use of secondary calibration in large area pulsed solar simulators (LAPSS) is discussed. It is argued that primary calibration in sunlight is time consuming, that only a limited sun calibration of a set of primary reference cells is required, that the LAPSS light source is filtered to closely match the am 1.5 direct spectrum, and that the temperal stability of the filtered LAPSS is excellent. There is the possibility of a lower error rate. Lower costs are anticipated.

Mueller, R.↗

Electrical characterization of an inductively coupled gaseous electronics conference reference cell

Plasma parameters and particularly the external electrical operational parameters are examined with respect to mode transition and hysteresis. The external electrical parameters such as antenna current (I{sub c}) and antenna voltage (V{sub c}) amplitudes are measured after the matching network and discussed for an inductively coupled argon discharge. A wide range of discharge conditions by varying applied power (up to 150 W at 13.56 MHz), gas pressure (0.7-7.5 Pa), and electrostatic coupling strength are measured for a gaseous electronics conference radio frequency reference cell. The effect on the power coupling efficiency by varying electrostatic coupling strength is studied via implementing two distinct grounded Faraday shields, in addition to the original nonshielded condition. A brief discussion on the evolution of floating potential, plasma potential, electron density, and electron energy distribution function with power and pressure is also presented mainly in context to mode transitions and hysteresis. Relatively smooth transitions in the plasma parameters and in the external electrical parameters are measured close to H to E mode transition region. Contrary to plasma parameters, however, the reverse transition from E to H mode was found to be abrupt in external parameters. The plasma parameters are measured using a commercial Langmuir probe, whereas the antenna currents and voltages are measured using a homebuilt Rogowski coil and capacitor divider, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Air mass 1.5 global and direct solar simulation and secondary reference cell calibration using a filtered large area pulsed solar simulator

Spectral mismatch between a solar simulator and a desired spectrum can result in nearly 20 percent measurement error in the output of photovoltaic devices. This occurs when a crystalline silicon cell monitors the intensity of an unfiltered large area pulsed solar simulator (LAPSS) simulating the ASTM air mass 1.5 direct spectrum and the test device is amorphous silicon. The LAPSS spectral irradiance is modified with readily available glass UV filters to closely match either the ASTM air mass 1.5 direct or global spectrum. Measurement error is reduced to about 1 percent when using either filter if the reference cell and test device are the same general type.

Mueller, Robert L.↗

Pyranometers and Reference Cells, What's the Difference?: Preprint

As the photovoltaic industry has grown exponentially in the past decade, large photovoltaic (PV) fields have become more common. The investors for these projects calculate the expected return on investment based on expected electricity generation and adjust the interest rates and other financial terms according to the perceived risk. These calculations usually assume worst case according to thelisted warranty and any uncertainty in the measurement is translated directly into a reduced predicted performance. Because a 1% difference in predicted output could represent a large fraction of the expected return on investment, a small reduction in uncertainty translates into a much larger value to the entity making investment decisions. To reduce perceived risk in large-scale solarinvestments power plant performance (or production) guarantees have become increasingly common. This two part article explores some subtleties of accurately measuring PV efficiency in the field.

14 SOLAR ENERGY↗

Influence of Diffuse and Ground-Reflected Irradiance on the Spectral Modeling of Solar Reference Cells

Thermal Energy Storage (TES) is a key component for solar thermal applications to bridge the gap between the demand for thermal energy and the supply of solar energy, whose availability depends on the time of day and season. Thus, cost-effective packed-bed thermal containers filled with a solid storage medium have been proposed for high-temperature sensible heat storage as materials are abundant and relatively cheap. Thus, it is necessary to investigate their performance and temperature profiles during the charge-discharge cycle. Several models are available for this purpose. Typically, the more detailed a model, the greater the computational effort required to solve it, and hence a time-efficient model is needed to prevent excessively long computation times for long-term analysis. At the more basic level, the common Hughes E-NTU model and the less realistic simplified Infinite-NTU model are very important for their less time and computational effort. In this paper, the appropriateness of employing the Infinite-NTU model was evaluated to investigate the performance of a typical and scalable rock-bed TES as a case study. The results presented provide a methodology to quickly test the validity of the model and predict the temperature profile for the case under study. Accordingly, such simple charge-discharge cycle thermal performance predictions are important to plan, design, and rapidly deploy a reliable and economical solar thermal system for the supply of valuable heat to high-temperature demanding applications of power generation and industrial processes as part of a rapid shift towards non-polluting renewable energy. Keywords: Solar Thermal, TES, Packed-bed, NTU model, Temperature profile

PV modeling↗