Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of Solar Reference Cells on a Two-Axis Tracker Using Spectral Measurements

A simple model calculating the performance of an IMT solar reference cell is proposed and tested under clear sky periods. One-minute data from EKO spectroradiometers collocated with an IMT reference cell are used for the analysis. Data are obtained at the NREL Solar Radiation Research Laboratory in Golden, Colorado and the UO Solar Radiation Monitoring Laboratory in Eugene, Oregon. The model is also applied and evaluated under cloudy conditions. A match of better than 1% is found between calculated clear sky values and IMT measurements for July, 2020. One- minute cloudy sky comparisons show a much larger variation, but when averaged over one hour, a standard deviation of 4% between the calculated and measured values is found.

atmospheric radiation↗

Pyranometers and Reference Cells: Part 2: What Makes the Most Sense for PV Power Plants?

As described in Part 1 of this two-part series, thermopile pyranometers and photovoltaic (PV) reference cells can both be used to measure irradiance; however, there are subtle differences between the data that are obtained. This two-part article explores some implications of uncertainty and subtleties of accurately measuring PV efficiency in the field. Part 2 of the series shows how reference cells can be used to more confidently predict PV performance, but how this could best be accomplished if historic irradiance data could be available in PV-technology-specific formats.

14 SOLAR ENERGY↗

Improved Field Evaluation of Reference Cell Using Spectral Measurements: Preprint

Spectral irradiance measurements as opposed to modeled spectral values are used to evaluate the effects of changing spectral distributions on the output of reference solar cells. Comparisons are made on a one-axis tracking surface to a Class A pyranometer. The ratio of the reference cells to reference pyranometers exhibit a bias over the day. Spectral and temperature modeling reproduce most but not all changes in the ratio over the day. Sources for this difference in modeling and performance of the reference cells are examined.

14 SOLAR ENERGY↗

Structural variant analysis of a cancer reference cell line sample using multiple sequencing technologies

The cancer genome is commonly altered with thousands of structural rearrangements including insertions, deletions, translocation, inversions, duplications, and copy number variations. Thus, structural variant (SV) characterization plays a paramount role in cancer target identification, oncology diagnostics, and personalized medicine. As part of the SEQC2 Consortium effort, the present study established and evaluated a consensus SV call set using a breast cancer reference cell line and matched normal control derived from the same donor, which were used in our companion benchmarking studies as reference samples. We systematically investigated somatic SVs in the reference cancer cell line by comparing to a matched normal cell line using multiple NGS platforms including Illumina short-read, 10X Genomics linked reads, PacBio long reads, Oxford Nanopore long reads, and high-throughput chromosome conformation capture (Hi-C). We established a consensus SV call set of a total of 1788 SVs including 717 deletions, 230 duplications, 551 insertions, 133 inversions, 146 translocations, and 11 breakends for the reference cancer cell line. To independently evaluate and cross-validate the accuracy of our consensus SV call set, we used orthogonal methods including PCR-based validation, Affymetrix arrays, Bionano optical mapping, and identification of fusion genes detected from RNA-seq. We evaluated the strengths and weaknesses of each NGS technology for SV determination, and our findings provide an actionable guide to improve cancer genome SV detection sensitivity and accuracy. A high-confidence consensus SV call set was established for the reference cancer cell line. A large subset of the variants identified was validated by multiple orthogonal methods.

59 BASIC BIOLOGICAL SCIENCES↗

Electrical characterization of an inductively coupled gaseous electronics conference reference cell

Plasma parameters and particularly the external electrical operational parameters are examined with respect to mode transition and hysteresis. The external electrical parameters such as antenna current (I{sub c}) and antenna voltage (V{sub c}) amplitudes are measured after the matching network and discussed for an inductively coupled argon discharge. A wide range of discharge conditions by varying applied power (up to 150 W at 13.56 MHz), gas pressure (0.7-7.5 Pa), and electrostatic coupling strength are measured for a gaseous electronics conference radio frequency reference cell. The effect on the power coupling efficiency by varying electrostatic coupling strength is studied via implementing two distinct grounded Faraday shields, in addition to the original nonshielded condition. A brief discussion on the evolution of floating potential, plasma potential, electron density, and electron energy distribution function with power and pressure is also presented mainly in context to mode transitions and hysteresis. Relatively smooth transitions in the plasma parameters and in the external electrical parameters are measured close to H to E mode transition region. Contrary to plasma parameters, however, the reverse transition from E to H mode was found to be abrupt in external parameters. The plasma parameters are measured using a commercial Langmuir probe, whereas the antenna currents and voltages are measured using a homebuilt Rogowski coil and capacitor divider, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pyranometers and Reference Cells, What's the Difference?: Preprint

As the photovoltaic industry has grown exponentially in the past decade, large photovoltaic (PV) fields have become more common. The investors for these projects calculate the expected return on investment based on expected electricity generation and adjust the interest rates and other financial terms according to the perceived risk. These calculations usually assume worst case according to thelisted warranty and any uncertainty in the measurement is translated directly into a reduced predicted performance. Because a 1% difference in predicted output could represent a large fraction of the expected return on investment, a small reduction in uncertainty translates into a much larger value to the entity making investment decisions. To reduce perceived risk in large-scale solarinvestments power plant performance (or production) guarantees have become increasingly common. This two part article explores some subtleties of accurately measuring PV efficiency in the field.

14 SOLAR ENERGY↗

Influence of Diffuse and Ground-Reflected Irradiance on the Spectral Modeling of Solar Reference Cells

Thermal Energy Storage (TES) is a key component for solar thermal applications to bridge the gap between the demand for thermal energy and the supply of solar energy, whose availability depends on the time of day and season. Thus, cost-effective packed-bed thermal containers filled with a solid storage medium have been proposed for high-temperature sensible heat storage as materials are abundant and relatively cheap. Thus, it is necessary to investigate their performance and temperature profiles during the charge-discharge cycle. Several models are available for this purpose. Typically, the more detailed a model, the greater the computational effort required to solve it, and hence a time-efficient model is needed to prevent excessively long computation times for long-term analysis. At the more basic level, the common Hughes E-NTU model and the less realistic simplified Infinite-NTU model are very important for their less time and computational effort. In this paper, the appropriateness of employing the Infinite-NTU model was evaluated to investigate the performance of a typical and scalable rock-bed TES as a case study. The results presented provide a methodology to quickly test the validity of the model and predict the temperature profile for the case under study. Accordingly, such simple charge-discharge cycle thermal performance predictions are important to plan, design, and rapidly deploy a reliable and economical solar thermal system for the supply of valuable heat to high-temperature demanding applications of power generation and industrial processes as part of a rapid shift towards non-polluting renewable energy. Keywords: Solar Thermal, TES, Packed-bed, NTU model, Temperature profile

PV modeling↗

Evaluation of Photodiode-Based Pyranometers and Reference Solar Cells on a Two-Axis Tracking System

The performance of photodiode-based pyranometers and reference solar cells are examined on a two-axis tracker surface. This is the third in a series of papers examining the performance of photodiode-based pyranometers and reference solar cells on fixed and tracking surfaces. Because the instruments are oriented normally to the incident radiation, angle-of-incidence effects are minimized. By removing the angle-of-incidence effects inherent in earlier studies, the change in the sensor's clear sky responsivity can be more clearly identified. It was found that the photodiode-based pyranometers demonstrate a larger change in responsivity than the reference solar cells. Spectral measurements are recommended to verify the cause of this difference.

14 SOLAR ENERGY↗

Evaluation of Photodiode-Based Pyranometers and Reference Solar Cells on a Two-Axis Tracking System: Preprint

The performance of photodiode-based pyranometers and reference solar cells are examined on a two-axis tracker surface. This is the third in a series of papers examining the performance of photodiode-based pyranometers and reference solar cells on fixed and tracking surfaces. Because the instruments are oriented normally to the incident radiation, angle-of-incidence effects are minimized. By removing the angle-of-incidence effects found in earlier studies, the change in the sensor's responsivity during the day can be more clearly identified. It was found that the photodiode-based pyranometers demonstrate a larger change in responsivity than the reference solar cells. Spectral measurements are recommended to verify the cause of this difference.

14 SOLAR ENERGY↗

Numerical and experimental calibration of calorimetric sample cell dedicated to nuclear heating measurements

Online nuclear measurements inside experimental channels of MTRs are needed for experimental works (to design set-ups) and for numerical works (input data) in order to better understanding complex phenomena occurring during the accelerated ageing of materials and the irradiation of nuclear fuel. In this paper we focus only on one kind of measurements: nuclear heating performed by means of a radiometric calorimeter. The aims of numerical and experimental works are firstly to optimize the sensor response for new energy deposit ranges and then to miniaturize this sensor for JHR irradiation conditions A first calorimeter, developed previously by the CEA, is studied. It corresponds to a graphite differential calorimeter divided into two twin cells (a reference cell, and a sample one). It is used with a non adiabatic mode or heat flow mode. Experimental calibration of the sample cell is presented. In that case, energy deposit is simulated by Joule effect and the sample cell is inserted into a bath at a regulated temperature and controlled flow. The response of the sensor is shown versus electrical power imposed for two flow regimes (intensive or moderated forced convection). These experimental results are compared to numerical works and improvements are discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spectroscopic methods and systems for isotopic analysis

Disclosed are spectroscopy systems and methods. A spectroscopy system can include a reference cell and a multi-pass sample cell. The reference arm can include an etalon and a reference cavity containing a reference gas. A system can include a fractional sublimation cold trap. Detectors of the reference and sample arms can detect both intensity and absorption spectra of impinging beams. A frequency calibration based on a reference absorption spectra can be used to analyze a sample absorption spectrum. The analysis can provide information regarding an absorption band shift of the sample absorption spectrum, said shift being related to the isotope concentration of the sample.

O'Rourke, Patrick E.↗

Introducing the Baseline Performance Reference (BPR) for Irradiance in PV System Applications

Photovoltaic (PV) reference cells, modules, and arrays respond in a complex manner to the many variables that define their operating environment. PV reference cells for irradiance measurement have similarities but also differences to operational PV modules. For this reason, a more neutral and a well-defined generic PV reference cell is needed, whose characteristics are close enough to most operational PV devices to make stable performance indicators possible but whose characteristics are not necessarily identical to any of them. This poster describes a new well-defined reference quantity for outdoor PV measurements, called the baseline performance reference (BPR).

baseline performance reference↗

Advanced SOFC quality control and the role of manufacturing defects on stack reliability

Atrex Energy rolled out first commercial SOFC generator products in 2013. Following that we embarked on implementation of mass production in order to ramp up productivity and lower the costs in the meantime. To ensure the goal of mass production, an accurate, cost effective and consistent quality control methodology needs to be in place. The aim of this DOE funded project is to devise a machine and methodology for cell quality control using modern non-destructive testing methods and cell rejection criterion based on the empirical determination of the role of manufacturing flaws on stack degradation and reliability. The work scope encompasses two goals aimed at 1) developing automatable techniques for objective flaw detection and 2) developing an understanding of the ramifications of flaws on stack and cell reliability. By accomplishing these two goals it is likely that an advanced stage Quality Control (QC) device can be developed. This project scope encompasses: 1) Invention of a high speed automated instrument for spatial mapping of surface and sub-surface imperfections in production cells (ex situ) using modern imaging techniques. 2) Identification of rejection criteria upon which to screen cells from production by: a. Magnification of the effect of production defects on cell degradation through fabrication and testing of micro-cells which encompass these imperfections. b. The long term testing of full size production cells both as single cells and in small stacks, in order to correlate the (in situ) performance and degradation with the imperfection type (identified ex-situ) and hence be able to classify imperfections as actual defects. We first built a defect library with the cells containing imperfections classified and documented. The cells with various imperfections were tested to evaluate the imperfection potential impact on cell electrochemical performance. Evaluations were conducted on minicell, single cell and stack levels. On minicell level, pinhole, scratch, crack, contamination, and pop-out were investigated. We found: (1) none of the imperfections causes calamity type failure, (2) pinholes do not show measurable effect on minicell performance, (3) imperfection such as electrolyte abrasion, scratch, and pop out cause minicell potential to fluctuate by different degrees; the cells with such imperfections exhibit sensitivity of potential to high fuel utilization and “self healing” behavior. On single cell level we evaluated the effect of long crack and high population pinholes. The cell with a long crack does not show performance compromise at start. There is no potential fluctuation or sensitivity to high fuel utilization or catastrophic failure. The voltage degradation due to thermal cycle is slightly higher than normal cells. The cells with high population pinholes perform surprisingly as well as normal cells over a period of 3,500h. Even when subjected to cyclic load condition, the cells 4 show negligible degradation. Our cells appear to have “self immunization” feature which fends off the adversary effects of certain imperfections. Defects were also evaluated on stack level. Two stacks were made each with ten defect cells. The first stack was tested for 13,2000h under steady load condition while the second was tested for 9,000h under transient load conditions. We found: (1) voltage fluctuation and sensitivity to thermal cycle were not observed in contrast to minicell test, (2) of the various cracks examined, including longitudinal cracks, circumferential crack, crack near closed and open ends, none exhibited distinguishable impact on performance, (3) defect cells exhibited higher degradation rates on average under steady load condition; Individually some defect cells performed similarly or better than reference cells, (4) under steady load condition all the cells degrade monotonically with degradation rate increasing with time, (5) under cyclic (transient) load condition, both defect and reference cells exhibit complex dynamic behaviors, (6) fuel loss (leak) was measured occasionally for stack 1, the cells with crack showed the highest fuel loss increase, nevertheless, no correlation with performance degradation could be established with certainty, and (7) no catastrophic failure ever happened other than incremental degradation. Posttest inspection and microanalysis were carried out; the observations are summarized in what follows: (1) Electrolyte pinholes, some scratches and IC porosity became undetectable after testing. (2) The cathode covering the popout defects is intact without any cracking or delamination. (3) The scratch was covered by cathode in pristine state; Ni oxide or NiO-YSZ filled the space where electrolyte was missing. After >10,000h operation, the cathode that used to cover the scratch was missing but the size of the scratch remains unchanged; there is a fairly dense Ni oxide layer on top of the scratch. (4) All of the cracks remain their original dimensions. Current collector kept longitudinal cracks closed which mitigated the adversary effect of crack on cell performance/durability. (5) The crack at open end showed some deterioration manifested by a small oxidation zone in the vicinity of the crack. Wide spectrum of imaging techniques were surveyed and evaluated to detect tubular SOFC defects. Optical methods, with and without assistance of expression technique, were applied to detect all kinds of defects. Thermograph method in combination of CO2 leak, ultra-sound and electric potential was also extensively evaluated to detect surface and under-surface defects such as short circuit. Based on these works, laser camera has been selected to build the final QC machine vision inspection system. The Gocator laser profile sensor was setup to generate 2D surface intensity images of tubular SOFC surface which were analyzed with Sherlock machine vision software supplied by Teledyne Dalsa. The Gocator output was integrated with the Sherlock software and enabled live images to be imported by a Common Vision Blox driver. The Sherlock software was programmed to detect various surface defects from the surface intensity images generated by the Gocator. These measurements are subsequently used to make pass or fail decisions.

01 COAL, LIGNITE, AND PEAT↗

Photovoltaic Mini-Module Soiling Stations: Cooperative Research and Development (Final Report)

Photovoltaic (PV) panels can become soiled due to a variety of environmental factors. This soiling reduces the amount of light reaching the cells and thus their energy output. The ratio of actual output of the soiled device that of a clean device is known as the soiling ratio. The daily change in soiling ratio is known as the soiling rate. To study soiling for different glass coatings. Two soiling stations were fabricated. The stations were designed to monitor the short-circuit current of PV cells encapsulated with glass featuring different coatings and measure the daily soiling ratio with a pair of reference cells, one of which is automatically brushed daily. This work meets the need to understand how the glass coatings perform in additional environments. The stations are designed to quantify both the soiling ratio (the ratio between actual/expected photovoltaic panel power output) as well as differences in anti-soiling performance of different glass coatings. The design of the dirty/clean reference cell system is described by Toth et al. The soiling ratio is calculated by calculating the average irradiance measured within one hour of solar noon by each of the reference cells and then taking the ratio of these daily near-noon averages. The soiling ratio time series for the station deployed in Georgia is shown in Figure 1. This figure shows that the soiling ratio at the site has not yet fallen below 0.99, indicating that peak daily soiling losses have been below 1%. The site was chosen because it is thought to be affected by pollen soiling. With continued monitoring over the course of at least a full year, we expect to be able to observe and quantify pollen soiling events.

14 SOLAR ENERGY↗

CEM MARS 6 Microwave Incident

A fire occurred in a CEM MARS 6 analytical microwave during microwave-assisted, acid digestion of a soil sample in a Research and Development (R&D) laboratory. The soil sample had been pretreated at 550°C for approximately 4 hours in a furnace prior to digesting in the microwave. Less than 1-gram aliquots of the pretreated soil sample were placed into separate microwave reaction vessels along with an acid mixture used for digestion. The microwave was used to facilitate digestion of the samples. Microwave reaction vessels were loaded with acid and soil samples, sealed in cassettes, and the cassettes placed onto a microwave carousel. A temperature probe that senses the reaction temperature during the run was inserted into the Reference Cell thermowell. The contents of the Reference Cell were identical to the contents of the other reaction cells. The researcher initiated the run and then left the laboratory to perform other work. Upon returning to check the digestion run, flames and smoke were observed originating from the microwave. The researcher exited the lab, immediate emergency actions were taken, and the local fire department responded and extinguished the fire. No personnel were injured, and no facility structural damage occurred. The affected microwave is a total loss. The fire investigation revealed the most credible cause of the fire is an incompatible temperature probe that did not accurately measure temperature of the liquid phase of the Reference sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗