Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Advanced development of double-injection, deep-impurity semiconductor switches

Deep-impurity, double-injection devices, commonly refered to as (DI) squared devices, represent a class of semiconductor switches possessing a very high degree of tolerance to electron and neutron irradiation and to elevated temperature operation. These properties have caused them to be considered as attractive candidates for space power applications. The design, fabrication, and testing of several varieties of (DI) squared devices intended for power switching are described. All of these designs were based upon gold-doped silicon material. Test results, along with results of computer simulations of device operation, other calculations based upon the assumed mode of operation of (DI) squared devices, and empirical information regarding power semiconductor device operation and limitations, have led to the conculsion that these devices are not well suited to high-power applications. When operated in power circuitry configurations, they exhibit high-power losses in both the off-state and on-state modes. These losses are caused by phenomena inherent to the physics and material of the devices and cannot be much reduced by device design optimizations. The (DI) squared technology may, however, find application in low-power functions such as sensing, logic, and memory, when tolerance to radiation and temperature are desirable (especially is device performance is improved by incorporation of deep-level impurities other than gold.

Hanes, M. H.↗

GaAs Reliability Database

The database consists of two main sections, the data references and the device reliability records. The reference section contains 8 fields: reference number, date of publication, authors, article title, publisher, volume, and page numbers.

GaAs electric performance↗

A simple technique for high resolution time domain phase noise measurement

A new time domain phase comparator is described. The device uses a novel technique to allow time domain phase measurements to be made with period and time interval counters without the use of offset reference oscillators. The device uses a single reference oscillator and allows measurements with a phase resolution greater than the noise floor of the reference. Data is presented showing a phase resolution of 0.02ps at 5 MHz with a crystal reference. The device has application in measuring the phase stability of systems where approximate phase quadrature can be maintained.

Reinhardt, V. S.↗

Gas Sensors Based on Single-Arm Waveguide Interferometers

Various optical technologies can be implemented in chemical sensing. Sensitive, rugged, and compact systems will be more likely built using interferometric waveguide sensors. Currently existing sensors comprise dual-arm systems with external reference arm, dual-arm devices with internal reference arm such as integrated Mach-Zehnder interferometer, and single-arm systems which employ the interference between different waveguide modes. These latter ones are the most compact and rugged but still sensitive enough to monitor volatile pollutants such as NH3 coming out of industrial refrigerators and fertilizer plants and stocks, NO, NO2, SO2, emitted by industrial burning processes. Single-arm devices in planar waveguide configuration most frequently use two orthogonally polarized modes TE (sub i) and TM (sub i) of the same order i. Sensing effect is based on the difference in propagation conditions for the modes caused by the environment. However, dual-mode single-order interferometers still have relatively low sensitivity with respect to the environment related changes in the waveguide core because of small difference between propagation constants of TE (sub i) and TM (sub i) modes of the same order. Substantial sensitivity improvement without significant complication can be achieved for planar waveguide interferometers using modes of different orders with much greater difference between propagation constants.

Sarkisov, Sergey↗

Multiabsorber Transition-Edge Sensors for X-Ray Astronomy

We are developing arrays of position-sensitive microcalorimeters for future x-ray astronomy applications. These position-sensitive devices commonly referred to as hydras consist of multiple x-ray absorbers, each with a different thermal coupling to a single-transition-edge sensor microcalorimeter. Their development is motivated by a desire to achieve very large pixel arrays with some modest compromise in performance. We report on the design, optimization, and first results from devices with small pitch pixels (<75 μm) being developed for a high-angular and energy resolution imaging spectrometer for Lynx. The Lynx x-ray space telescope is a flagship mission concept under study for the National Academy of Science 2020 decadal survey. Broadband full-width-half-maximum (FWHM) resolution measurements on a 9-pixel hydra have demonstrated ΔE(FWHM) = 2.23 ± 0.14 eV at Al-Kα, ΔE(FWHM) = 2.44 ± 0.29 eV at Mn-Kα, and ΔE(FWHM) = 3.39 ± 0.23 eV at Cu-Kα. Position discrimination is demonstrated to energies below <1 keV and the device performance is well-described by a finite-element model. Results from a prototype 20-pixel hydra with absorbers on a 50-μm pitch have shown ΔE(FWHM) = 3.38 ± 0.20 eV at Cr-Kα1. We are now optimizing designs specifically for Lynx and extending the number of absorbers up to 25/hydra. Numerical simulation suggests optimized designs could achieve ∼3 eV while being compatible with the bandwidth requirements of the state-of-the art multiplexed readout schemes, thus making a 100,000 pixel microcalorimeter instrument a realistic goal.

Smith, Stephen J.↗

Development and Testing of a Friction-Based Post-Installable Fiber-Optic Monitoring System for Subsea Applications

This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system capable of measuring pressure, strain, and temperature that can be deployed on existing subsea structures. A summary is provided of the design concept, prototype development, prototype performance testing, and subsequent design refinements of the device. The results of laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are also included. Limitations of the initial concept were identified during testing and future design improvements were proposed and later implemented. These new features enhance the coupling of the sensor device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on flowlines, risers, and other subsea structures. The work described in this paper investigates the design and test of a friction-based coupling device (herein referred to as a friction clamp) which is suitable for pipelines and structures that are suspended in the water column as well as for those that are resting on the seabed. The monitoring elements consist of fiberoptic sensors that are bonded to a stainless steel clamshell assembly with a high-friction surface coating. The friction clamp incorporates a single hinge design to facilitate installation of the clamp and dual rows of opposing fasteners to distribute the clamping force along the structure. The friction clamp can be modified to be installed by commercial divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance technologies that will benefit the environment, the public, and commercial industries.

Bentley, Nicole L.↗

Simplified phase detector

Tanlick sine-wave phase detector gives dc output voltage nearly proportional to phase difference between oscillator signal and reference signal. Device may be used for systems in which signal-to-noise ratio is high.

Hershey, L. M.↗

An investigation of wing leading-edge vortices at supersonic speeds

Studies at subsonic and transonic speeds of the fundamental vortex behavior on the leeward surface of wings have led to the design of several unique and novel leading-edge devices commonly referred to as 'vortex flaps'. The present investigation has the objective to provide some fundamental vortex-flow results obtained at supersonic speeds. Experimental studies were performed in which pressure data and several types of flow visualization data were obtained on the leeward surface of a series of flat delta-wing models to identify the various flow mechanisms which can occur and to determine the effect of leading-edge sweep, Mach number, and angle of attack on the vortex strength and location. The reported investigation forms part of a study which is to explore the use of wing leading-edge vortex technology as a supersonic wing-design tool. The obtained results indicate that the procedure of distributing the vortex force as a pressure variation about a vortex action line is a promising concept.

Miller, D. S.↗

Shape Memory Alloy Rock Splitters (SMARS) - A Non-Explosive Method for Fracturing Planetary Rocklike Materials and Minerals

A static rock splitter device based on high-force, high-temperature shape memory alloys (HTSMAs) was developed for space related applications requiring controlled geologic excavation in planetary bodies such as the Moon, Mars, and near-Earth asteroids. The device, hereafter referred to as the shape memory alloy rock splitter (SMARS), consisted of active (expanding) elements made of Ni50.3Ti29.7Hf20 (at.%) that generate extremely large forces in response to thermal input. The preshaping (training) of these elements was accomplished using isothermal, isobaric and cyclic training methods, which resulted in active components capable of generating stresses in excess of 1.5 GPa. The corresponding strains (or displacements) were also evaluated and were found to be 2 to 3 percent, essential to rock fracturing and/or splitting when placed in a borehole. SMARS performance was evaluated using a test bed consisting of a temperature controller, custom heaters and heater holders, and an enclosure for rock placement and breakage. The SMARS system was evaluated using various rock types including igneous rocks (e.g., basalt, quartz, granite) and sedimentary rocks (e.g., sandstone, limestone).

NiTiHf↗

Guideline for Single-Event Effect (SEE) Testing of System on a Chip (SOC) Devices

The use of complex single and multicore processors with significant cache memory, on-chip peripherals, memory controllers, and high speed input/output (IO) that integrate many of the parts of a traditional computer system is becoming more common in space applications. Such devices are often referred to as system on a chip devices (SOCs), even though the term is used somewhat inaccurately due to the lack of analog and mixed signal subcircuits. These devices are complex combinations of single- or multi-core processors with memory controllers, high-speed input/output (IO), and other peripheral structures that formerly would have been handled by off-chip resources. In the past the processors were tested for single event effects (SEE) separately, and the peripherals were often put into custom application-specific integrated circuits (ASICs) along with other resources required by the user. Performance and cost pressures have pushed commercial devices to incorporate many of the functional blocks into a single chip, an SOC. The NASA Electronic Parts and Packaging Program (NEPP) has been examining ways to perform SEE radiation hardness assurance (RHA) testing of these processor-centric SOCs to achieve reasonable understanding of their performance in space missions.

Guertin, Steven M.↗

Wind-tunnel research comparing lateral control devices, particularly at high angles of attack III : ordinary ailerons rigged up 10 degrees when neutral

This report presents the results of wind-tunnel tests made on three model wings having different sizes of ordinary ailerons rigged up 10 degrees when neutral, the same models having previously been tested with the ailerons rigged even with the wings in the usual manner. One of the wings had ailerons of medium size, 25 per cent of the wing chord by 40 per cent of the semispan, one had long, narrow ailerons, and one had short, wide ones. These tests are part of a general investigation on lateral control devices, with particular reference to the control at high angles of attack, in which all the devices are being subjected to the same series of tests in the 7 by 10 foot wind tunnel of the National Advisory Committee for Aeronautics. Force tests of the usual type, free-autorotation tests, and forced-rotation tests were made showing the effect of the ailerons on the general performance of the wing, on the lateral controllability, and on the lateral stability.

Weick, Fred E↗

Electrochemical detection device

A standard pH reference electrode and a platinum cathodic electrode are positioned in a container with suitable nutrient medium for microbial growth plus the sample to be tested. The two electrodes are connected to electronic circuitry including an up/down counter whicn counts up for the first 80 minutes after a test has initiated. Then the potential between the two electrodes is tracked by the electronic circuitry and after there is a change of 10 mv a signal is sent to the up/down counter to cause it to reverse its count. When there is a additional 20 mv change in the potential between the two electrodes another signal is sent to the up/down counter, signalling it to stop. The resulting count on the counter is equal to the length of time for the inoculum to begin the production of measurable amounts of H2 after inoculation.

Young, R. N.↗

High-Density, High-Bandwidth, Multilevel Holographic Memory

A proposed holographic memory system would be capable of storing data at unprecedentedly high density, and its data transfer performance in both reading and writing would be characterized by exceptionally high bandwidth. The capabilities of the proposed system would greatly exceed even those of a state-of-the art memory system, based on binary holograms (in which each pixel value represents 0 or 1), that can hold .1 terabyte of data and can support a reading or writing rate as high as 1 Gb/s. The storage capacity of the state-of-theart system cannot be increased without also increasing the volume and mass of the system. However, in principle, the storage capacity could be increased greatly, without significantly increasing the volume and mass, if multilevel holograms were used instead of binary holograms. For example, a 3-bit (8-level) hologram could store 8 terabytes, or an 8-bit (256-level) hologram could store 256 terabytes, in a system having little or no more size and mass than does the state-of-the-art 1-terabyte binary holographic memory. The proposed system would utilize multilevel holograms. The system would include lasers, imaging lenses and other beam-forming optics, a block photorefractive crystal wherein the holograms would be formed, and two multilevel spatial light modulators in the form of commercially available deformable-mirror-device spatial light modulators (DMDSLMs) made for use in high speed input conversion of data up to 12 bits. For readout, the system would also include two arrays of complementary metal oxide/semiconductor (CMOS) photodetectors matching the spatial light modulators. The system would further include a reference-beam sterring device (equivalent of a scanning mirror), containing no sliding parts, that could be either a liquid-crystal phased-array device or a microscopic mirror actuated by a high-speed microelectromechanical system. Time-multiplexing and the multilevel nature of the DMDSLM would be exploited to enable writing and reading of multilevel holograms. The DMDSLM would also enable transfer of data at a rate of 7.6 Gb/s or perhaps somewhat higher.

Chao, Tien-Hsin↗

Nanostructures Exploit Hybrid-Polariton Resonances

Nanostructured devices that exploit the hybrid-polariton resonances arising from coupling among photons, phonons, and plasmons are subjects of research directed toward the development of infrared-spectroscopic sensors for measuring extremely small quantities of molecules of interest. The spectroscopic techniques in question are surface enhanced Raman scattering (SERS) and surface enhanced infrared absorption (SEIRA). An important intermediate goal of this research is to increase the sensitivity achievable by these techniques. The basic idea of the approach being followed in this research is to engineer nanostructured devices and thereby engineer their hybrid-polariton resonances to concentrate infrared radiation incident upon their surfaces in such a manner as to increase the absorption of the radiation for SEIRA and measure the frequency shifts of surface vibrational modes. The underlying hybrid-polariton-resonance concept is best described by reference to experimental devices that have been built and tested to demonstrate the concept. The nanostructure of each such device includes a matrix of silicon carbide particles of approximately 1 micron in diameter that are supported on a potassium bromide (KBr) or poly(tetrafluoroethylene) [PTFE] window. These grains are sputter-coated with gold grains of 40-nm size (see figure). From the perspective of classical electrodynamics, in this nanostructure, that includes a particulate or otherwise rough surface, the electric-field portion of an incident electromagnetic field becomes concentrated on the particles when optical resonance conditions are met. Going beyond the perspective of classical electrodynamics, it can be seen that when the resonance frequencies of surface phonons and surface plasmons overlap, the coupling of the resonances gives rise to an enhanced radiation-absorption or -scattering mechanism. The sizes, shapes, and aggregation of the particles determine the frequencies of the resonances. Hence, the task of designing a nanostructure to exhibit the desired radiation-absorption properties translates, in large part, to selecting particle sizes and shapes to obtain the desired enhanced coupling of energy from photons to plasmons and phonons. To broaden the spectral region(s) of enhanced absorption, one would select a distribution of particle sizes and shapes.

Anderson, Mark↗

Wind tunnel research comparing lateral control devices, particularly at high angles of attack X : various control devices on a wing with a fixed auxiliary airfoil

Results are given of a series of systemic tests comparing lateral control devices with particular reference to their effectiveness at high angles of attack. These tests were made with two sizes of ordinary ailerons and different sizes of spoilers on a Clark Y wing model having a narrow auxiliary airfoil fixed ahead and above the leading edge, the chords of the main and auxiliary airfoils being parallel. In addition, the auxiliary airfoil itself was given angular deflection. The purpose was to provide rolling moments for lateral control. The tests were made in a 7 by 10 foot wind tunnel. They included both force and rotation tests to show the effect of the devices on the lift and drag characteristics of the wing and on the lateral stability characteristics, as well as lateral control. They showed that none of the aileron arrangements tried would give rolling control of an assumed satisfactory value at all angles of attack up to the stall. However, they would give satisfactory values, but at the expense of abnormally high deflections and very heavy hinge moments. The most effective combination of ailerons and spoilers gave satisfactory values of rolling moment at angles of attack below the stall, and the values did not fall off as rapidly above the stall as with ailerons alone. With an arrangement of this type having the proper relative proportions and linkage, it should be possible to obtain reasonably satisfactory yawing moments and control forces. Deflecting one-half of the auxiliary airfoil downward for the purpose of control gave strong favorable yawing moments at all angles of attack, but gave very small rolling moments at the low angles of attack.

Weick, Fred E↗

Minus 55 to plus 200 deg C 12 bit analog-to-digital converter

A 12 bit successive approximation analog to digital converter that offers moderately high speed precision data conversion at a reasonable level of cost and complexity is studied. The ADCH10HT extends this capability over a temperature range of -55 to +200 C. No missing-code performance is maintained over the entire temperature range. The converter is completely self-contained with internal clock and +10 volt reference. The CMOS devices offer low power dissipation, so that the internal temperature of the hybrid circuit does not rise as much from self heating. In CMOS circuits, pn junction leakage currents are returned to the supplies so that the logic keeps working at temperatures up to 250 C.

Smith, L. R.↗

Monitoring of Reactive Atmospheric Species

Reactive atmospheric species produced and detected to provide reference spectra. Compact device insensitive to scattered light and has low power consumption.

Webster, C. R.↗

Observations of a monotectic solidification interface morphology

For detailed studies of the region around a solidification interface on a microscopic scale, a very thin (essentially two-dimensional) test cell may be translated across two temperature-controlled heating/cooling blocks and viewed with a microscope. Such a device is sometimes referred to as a temperature gradient microscope stage (TGS). Of particular interest in this study is the behavior of a monotectic type solution during solidification. Succinonitrile based model systems for metallic monotectic alloys, when solidified on a TGS, form an unusual 'worm-like' micromorphology. These interfaces are observable in situ under high optical magnification during growth.

Kaukler, W. F.↗