Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An Ultra-Stable Reference Electrode as In-Situ System Diagnostics Tool for Redox Flow Batteries - CRADA 634 (Abstract)

The objective of the proposed project is to develop and demonstrate an ultra-stable reference electrode (RE) technology as an in-situ system diagnostics tool integrated in kW scaled commercial vanadium redox flow battery (VRFB) stacks for long-duration energy storage (LDES) applications and to advance its commercialization, with expected cell reliability enhancement in stack life increase of 6-10 % and levelized cost of storage (LCOS) reduction of 5-8 %. In this project, PNNL will partner with Stryten Energy LLC, with a total budget of $250K and 50% cost share for one year.

25 ENERGY STORAGE↗

High-Temperature Reference Electrode for Chloride Salts

The unique properties of molten salts enable their use in a wide range of applications, including metal electrodeposition, electrorefining, and as electrolytes in high-temperature batteries. Moreover, molten salts will be used as a coolant in molten salt reactors and as working media in pyrorocessing for nuclear energy applications. As a result, predicting the behavior and properties of the elements involved in the technological processes that employ molten salts is important. The activity of chloride ions in chloride molten salts has a large influence on the behavior of the salts in these applications and one of the key components in measuring the chloride activity is a stable reference electrode. This project aims to develop a reliable and convenient method for measuring chloride ion activity over a wide range of temperatures and salt compositions in chloride salt mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Materials of Reference Electrodes for Radioactive Waste Tank Service – A Literature Review

The Hanford site stores approximately 55 million gallons of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground, carbon steel storage tanks, 149 of these are single shell tanks (SSTs) and 28 of these are double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The DSTs have been in service for 38 to 56 years and current plans indicate that WTP operations will be completed in 2075. Thus, the tanks will need to remain in service far beyond the initial 40-year life expectancy. For life extension of the tanks, effective corrosion control practices must remain in force. This effort includes direct measurements of the extent of corrosion (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An In-Depth Exploration of the Electrochemical Oxygen Reduction Reaction (ORR) Phenomenon on Carbon-Based Catalysts in Alkaline and Acidic Mediums

Detailed studies of the electrochemical oxygen reduction reaction (ORR) on catalyst materials are crucial to improving the performance of different electrochemical energy conversion and storage systems (e.g., fuel cells and batteries), as well as numerous chemical synthesis processes. In the effort to reduce the loading of expensive platinum group metal (PGM)-based catalysts for ORR in the electrochemical systems, many carbon-based catalysts have already shown promising results and numerous investigations on those catalysts are in progress. Most of these studies show the catalyst materials’ ORR performance as current density data obtained through the rotating disk electrode (RDE), rotating ring-disk electrode (RRDE) experiments taking cyclic voltammograms (CV) or linear sweep voltammograms (LSV) approaches. However, the provided descriptions or interpretations of those data curves are often ambiguous and recondite which can lead to an erroneous understanding of the ORR phenomenon in those specific systems and inaccurate characterization of the catalyst materials. In this paper, we presented a study of ORR on a newly developed carbon-based catalyst, the nitrogen-doped graphene/metal-organic framework (N-G/MOF), through RDE and RRDE experiments in both alkaline and acidic mediums, taking the LSV approach. The functions and crucial considerations for the different parts of the RDE/RRDE experiment such as the working electrode, reference electrode, counter electrode, electrolyte, and overall RDE/RRDE process are delineated which can serve as guidelines for the new researchers in this field. Experimentally obtained LSV curves’ shapes and their correlations with the possible ORR reaction pathways within the applied potential range are discussed in depth. We also demonstrated how the presence of hydrogen peroxide (H2O2), a possible intermediate of ORR, in the alkaline electrolyte and the concentration of acid in the acidic electrolyte can maneuver the ORR current density output in compliance with the possible ORR pathways.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Printed Potentiometric Nitrate Sensors for Use in Soil

Plant-available nitrogen, often in the form of nitrate, is an essential nutrient for plant growth. However, excessive nitrate in the environment and watershed has harmful impacts on natural ecosystems and consequently human health. A distributed network of nitrate sensors could help to quantify and monitor nitrogen in agriculture and the environment. Here, we have developed fully printed potentiometric nitrate sensors and characterized their sensitivity and selectivity to nitrate. Each sensor comprises an ion-selective electrode and a reference electrode that are functionalized with polymeric membranes. The sensitivity of the printed ion-selective electrodes was characterized by measuring their potential with respect to a commercial silver/silver chloride reference electrode in varying concentrations of nitrate solutions. The sensitivity of the printed reference electrodes to nitrate was minimized with a membrane containing polyvinyl butyral (PVB), sodium chloride, and sodium nitrate. Selectivity studies with sulphate, chloride, phosphate, nitrite, ammonium, calcium, potassium, and magnesium showed that high concentrations of calcium can influence sensor behavior. The printed ion-selective and reference electrodes were combined to form a fully printed sensor with sensitivity of −48.0 ± 3.3 mV/dec between 0.62 and 6200 ppm nitrate in solution and −47 ± 4.1 mV/dec in peat soil.

Baumbauer, Carol L. (ORCID:0000000246747551)↗

Microbial sensor system for the assessment of subsurface environments

A microbial sensor, system, and method that can be used to determine a chemical environment and/or substrate concentrations in anaerobic or aerobic environments, such as soils, sediments and ground waters, are disclosed. An exemplary system uses one or more (e.g., inert) measurement electrodes and a reference electrode. The reference electrode can include an electrode exposed to atmospheric oxygen (e.g., a cathode) or an electrode exposed to stable anaerobic or aerobic conditions. The exemplary microbial sensor system measures open-circuit voltage to characterize the chemical (oxidizing or reducing) environment and/or recovery voltage to measure substrate concentrations in the subsurface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microbial sensor system for the assessment of subsurface environments

A microbial sensor, system, and method that can be used to determine a chemical environment and/or substrate concentrations in anaerobic or aerobic environments, such as soils, sediments and ground waters, are disclosed. An exemplary system uses one or more (e.g., inert) measurement electrodes and a reference electrode. The reference electrode can include an electrode exposed to atmospheric oxygen (e.g., a cathode) or an electrode exposed to stable anaerobic or aerobic conditions. The exemplary microbial sensor system measures open-circuit voltage to characterize the chemical (oxidizing or reducing) environment and/or recovery voltage to measure substrate concentrations in the subsurface.

Burge, Scott R.↗

Precautions of Using Three-Electrode Configuration to Measure Electrode Overpotential in Solid Oxide Electrochemical Cells: Insights from Finite Element Modeling

Accurate determination of electrode overpotentials is essential to assess the performance of the electrode and understand the rate-limiting steps involved. Three-electrode configuration with the use of a reference electrode at a fixed potential is a standard way to measure overpotential of a specific electrode in liquid electrochemical systems. However, application of such three-electrode configuration to solid electrochemical cells for overpotential determination is not straightforward and requires extra caution. Here we report a theoretical Finite Element Analysis on the geometrical requirements for which the reference electrode can be applied to anode- or electrolyte-supported solid oxide button cells. The modeling results suggest that the symmetry of the working and counter electrodes is the key factor determining if a reference electrode is suitable to use. For anode-supported fuel cells with asymmetrical working and counter electrodes, reference electrode cannot be used under all circumstances. To use reference electrode for overpotential measurements, electrolyte-supported cells with symmetrical semicircular-shaped electrodes are preferred. A data processing procedure has also been presented to obtain the electrode overpotential from the measured potential using the three-electrode scheme in solid oxide electrochemical cells.

25 ENERGY STORAGE↗

Electrochemical measurement and analysis of YCl 3 , ScCl 3 , GdCl 3 and MgCl 2 in molten eutectic LiCl-KCl

For this work, electrochemical measurements of YCl 3 , ScCl 3 , GdCl 3 and MgCl 2 were obtained in molten LiCl-KCl eutectic at 773 K using a three-electrode configuration. Tungsten rods were used as the working and counter electrodes. Two quasi- and one reference electrode(s) (glassy carbon, nickel wire, and Ni/NiO) were used to collect electrochemical measurements of the analyte salts. Cyclic voltammetry data were analyzed to calculate values of diffusion coefficient, exchange current density, and charge transfer resistance and were determined to be on the order of 10 –5 cm 2 s –1 , 10 –2 A cm –2 , and 10 0 Ω; respectively. In general, the values of diffusion coefficients were found to be consistent with those reported of high-temperature molten salts. Relatively large values of exchange current density corresponded with smaller values of charge transfer resistance. These values were found to be reasonable in comparison to results available in the literature. The measured cyclic voltammograms were normalized with respect to both lithium reduction and chloride ion oxidation potentials. Such a normalization technique is effective for comparing experimentally obtained cyclic voltammetry data to those that have been published. An analysis of experimentally obtained results indicates the relation of electrode reactions (e.g., differences of reduction potentials) are independent of the choice of reference electrode. Additionally, the choice of reference electrode did not affect the electrochemical window, exchange current density, or diffusion coefficient values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microbial sensor system for monitoring the environment and surfaces

A microbial sensor, system and method that can be used to determine the biochemical conditions of waters, saturated sediments, unsaturated soils, rhizosphere and other environments is disclosed. The flexibility of the microbial sensor design allows for the monitoring of surfaces (skin, ventilation conduits, etc.). An electrochemical microbial sensor system is composed of an indicator electrode(s) and a reference electrode. The reference electrode employs a hydrogen permeable membrane. The electrochemical system is interfaced into a signal/communication module allowing the manual or automated collection of data from field deployments and laboratory investigations. The data is transmitted using various communication technologies including Bluetooth™, cellular, satellite and radio telemetry to cloud-based data management systems. The stored data may be downloaded by users using open-source dashboard and visualization software to image the various environments and/or surfaces investigated.

Burge, Scott R.↗