Radiative transfer based retrieval of reflectance from calibrated radiance imagery measured by an imaging spectrometer for lithological mapping of the Clark Mountains, California

Spectral radiance imagery measured by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are reduced to reflectance through compensation for atmospheric scattering, water vapor absorption, absorption of the well mixed gases, solar irradiance and the solar zenith angle. The LOWTRAN 7 (Kneizys et al., 1989) radiative transfer code form the basis for this retrieal. LOWTRAN 7 is constrained with water vapor determinations from the AVIRIS radiance data through an algorithm operating on the 940 nm atmospheric water band for every spatial element. In situ measurements of atmospheric optical depths are used to constrain the LOWTRAN 7 aerosol models. Accuracy of the retrieved reflectance spectra is evaluated with respect to surface spectra measured at the time of the overflight. The mineral bastnaesite is identified in the analysis of the retrieved reflectance imagery. These reflectance data provide a means to map the subtle mineral gradients in the PreCambrian block of the Clark Mountain range in southeastern California for geological analysis.

Green, Robert O.↗

Field calibration of reference reflectance panels

A procedure for calibrating reference reflectance panels using the sun as the radiation source and a pressed-polytetrafluoroethylene powder standard is described. The directional/directional reflectance factor and the directional/hemispheric reflectance factor are examined. Directional/directional voltage responses for pressed-halon are analyzed. Three painted BaSO4 and one painted halon were calibrated using the proposed procedure. The effects of diffuse irradiance on reflectance-factor measurements are investigated. It is determined that the method has an accuracy on the order of 1 percent. The advantages and disadvantages of this method are discussed.

Jackson, Ray D.↗

Calibration to surface reflectance of terrestrial imaging spectrometry data: Comparison of methods

Many algorithms for spectral analysis of imaging spectroscopy data of the Earth's surface require that the data be calibrated to surface reflectance. Calibration requires removing instrumental response, solar irradiance, atmospheric transmittance, and atmospheric scattering from the radiance detected at the sensor. Depending on the amount of support data, this can be a formidable task. This paper examines four methods of calibration: (1) a radiative transfer model from the University of Colorado (ATREM: Gao and Goetz, 1990; Gao et al., 1992), (2) a MODTRAN-based method developed at the Jet Propulsion Lab by Green et al., (1191), (3) a ground calibration using known sites as standards, and (4) a combined approach using radiative transfer methods and ground calibration. Data from the Airborne Visual and Infra-Red Imaging Spectrometer (AVIRIS) instrument were evaluated from data sets obtained over multiple years and multiple sites.

Clark, Roger N.↗

Laboratory calibration of field reflectance panels

A method used for calibrating field reflectance panels in the visible and shortwave infrared wavelength range is described. The directional reflectance factor of painted barium sulfate (BaSO4) panels is determined. The reference for this method is the hemispherical reflectance of pressed polytetrafluoroethylene (halon) powder prepared according to National Bureau of Standards (NBS) directions. The panels and a radiometer are mounted on rotation stages to measure the reflectance factor at different incidence and view angles. The sensor can be any laboratory or field filter radiometer small enough to mount on the apparatus. The method is used to measure the reflectance factors of halon and BaSO4 panels between 0.45 and 0.85 micrometers. These reflectance factors are compared to those measured by a field apparatus. The results agree to within 0.013 in reflectance at incidence angles between 15 and 75 degrees.

Biggar, S. F.↗

MODIS Aqua Reflective Solar Bands Calibration for NASA's R2018 Ocean Color Products

Remote sensing ocean color products have stringent requirements on radiometric calibration stability. To address a calibration deficiency in MODIS Aqua in recent years, the NASA Ocean Biological Processing Group (OBPG) developed a new calibration for the reflective solar bands. Prior to the reprocessing of NASA's ocean color products for 2018 (R2018), the OBPG MODIS products had been based on calibration provided by the MODIS Calibration Support Team (MCST). Several modifications were made to the MCST calibration approach to improve the calibration accuracy for ocean color products. These include: 1) apply 936nm detector normalization to solar diffuser stability monitor (SDSM) data to reduce coherent noise; 2) modeling solar diffuser (SD) degradation wavelength dependency to determine SD degradation in near-infrared and shortwave infrared wavelength; 3) detector gains are computed using SD screen-closed data to better match ocean radiance levels in all bands; 4) a simple atmospheric correction is performed to reduce bidirectional reflectance distribution function (BRDF) effects in desert trends; 5) modulated relative spectral response (RSR) impact on ocean data is estimated and used to adjust the calibration coefficients. 6) smoothing is used to characterize the temporal change in calibration, and response versus scan angle (RVS) changes are characterized using 2nd order polynomials to improve spatial/temporal calibration stability. Relative to the previous R2014 ocean color products, the R2018 calibration removed the suspect late-mission global trends in blue-band water-leaving reflectance, and some anomalously large short-term variability (spikes) in the temporal trend of chlorophyll concentration. This paper will describe the OBPG calibration with a focus on the differences between the MCST and OBPG approaches.

calibration↗

Landsat Data Continuity Mission Calibration and Validation

The primary payload for the Landsat Data Continuity Mission (LDCM) is the Operational Land Imager (OLI), being built by Ball Aerospace and Technologies, under contract to NASA. The OLI has spectral bands similar to the Landsat-7 ETM+, minus the thermal band and with two new bands, a 443 nm band and 1375 nm cirrus detection band. On-board calibration systems include two solar diffusers (routine and pristine), a shutter and three sets of internal lamps (routine, backup and pristine). Being a pushbroom opposed to a whiskbroom design of ETM+, the system poses new challenges for characterization and calibration, chief among them being the large focal plane with 75000+ detectors. A comprehensive characterization and calibration plan is in place for the instrument and the data throughout the mission including Ball, NASA and the United States Geological Survey, which will take over operations of LDCM after on-orbit commissioning. Driving radiometric calibration requirements for OLI data include radiance calibration to 5% uncertainty (1 q); reflectance calibration to 3% uncertainty (1 q) and relative (detector-to-detector) calibration to 0.5% (J (r). Driving geometric calibration requirements for OLI include bandto- band registration of 4.5 meters (90% confidence), absolute geodetic accuracy of 65 meters (90% CE) and relative geodetic accuracy of 25 meters (90% CE). Key spectral, spatial and radiometric characterization of the OLI will occur in thermal vacuum at Ball Aerospace. During commissioning the OLI will be characterized and calibrated using celestial (sun, moon, stars) sources and terrestrial sources. The USGS EROS ground processing system will incorporate an image assessment system similar to Landsat-7 for characterization and calibration. This system will have the added benefit that characterization data will be extracted as part of the normal image data processing, so that the characterization data available will be significantly larger than for Landsat-7 ETM+.

Markham, Brian L.↗

Using the Moon to Track MODIS Reflective Solar Bands Calibration Stability

MODIS has 20 reflective solar bands (RSB) in the visible (VIS), near infrared (NIR), and short-wave infrared (SWIR) spectral regions. In addition to instrument on-board calibrators (OBC), lunar observations have been used by both Terra and Aqua MODIS to track their reflective solar bands (RSB) on-orbit calibration stability. On a near monthly basis, lunar observations are scheduled and implemented for each instrument at nearly the same lunar phase angles. A time series of normalized detector responses to the Moon is used to monitor its on-orbit calibration stability. The normalization is applied to correct the differences of lunar viewing geometries and the Sun-Moon-Sensor distances among different lunar observations. Initially, the lunar calibration stability monitoring was only applied to MODIS bands (1-4 and 8-12) that do not saturate while viewing the Moon. As the mission continued, we extended the lunar calibration stability monitoring to other RSB bands (bands 13-16) that contain saturated pixels. For these bands, the calibration stability is monitored by referencing their non-saturated pixels to the matched pixels in a non-saturation band. In this paper, we describe this relative approach and apply it to MODIS regularly scheduled lunar observations. We present lunar trending results for both Terra and Aqua MODIS over their entire missions. Also discussed in the paper are the advantages and limitations of this approach and its potential applications to other earth-observing sensors. Keywords: Terra, Aqua, MODIS, sensor, Moon, calibration, stability

Xiong, Xiaoxiong↗

The First SIMBIOS Radiometric Intercomparison (SIMRIC-1), April-September 2001

This report describes the first SIMBIOS (Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies) Radiometric Intercomparison (SIMRIC-1). The purpose of the SIMRIC-1 is to ensure a common radiometric scale of the calibration facilities that are engaged in calibrating in situ radiometers used for ocean color related research and to document the calibration procedures and protocols. SIMBIOS staff visited the seven participating laboratories for at least two days each. The SeaWiFS Transfer Radiometer SXR-II measured the calibration radiances produced in the laboratories. The measured radiances were compared with the radiances expected by the laboratories. Typically, the measured radiances were higher than the expected radiances by 0 to 2%. This level of agreement is satisfactory. Several issues were identified, where the calibration protocols need to be improved, especially the reflectance calibration of the reference plaques and the distance correction when using the irradiance standards at distances greater than the 50 cm. The responsivity of the SXR-II changed between 0.3% (channel 6) and 1.6% (channel 2) from December 2000 to December 2001. Monitoring the SXR-II with a portable light source showed a linear drift of the calibration, except for channel 1, where a 2% drop occurred in summer.

Meister, Gerhard↗

Ka-Band ARM Zenith Radar (KAZR) Active Remote Sensing of Clouds (ARSCL) CloudSat Calibration (KAZRARSCL-CLOUDSAT) (Value-Added Product Report)

The Ka-band ARM Zenith Radar Active Remote Sensing of CLouds CloudSat-aligned (KAZRARSCL-CLOUDSAT) Value-Added Product (VAP) applies satellite-based reflectivity calibrations to KAZRARSCL data sets. The Atmospheric Radiation Measurement (ARM) user facility has primarily used radar subsystem calibration monitoring to track cloud radar reflectivity drift over time, since reliable external calibration sources or other absolute references (such as corner reflectors) have historically been unavailable or impracticable. A study by Kollias et al. (2019) examined cloud reflectivity profiles observed with a well-characterized spaceborne downward-pointing millimeter cloud radar, operating as part of NASA’s CloudSat satellite mission (Tanelli et al. 2008). The Kollias team derived monthly statistical reflectivity offsets between CloudSat and the various generations of ARM cloud radars (millimeter wavelength cloud radar [MMCR], W-Band ARM Cloud Radar [WACR[, and Ka-band ARM Zenith Radar [KAZR]) for many, but not all, months at most fixed and mobile ARM sites over the period 2007-2017. These offsets, when available, are applied to the existing KAZRARSCL VAP products using the KAZRARSCL-CLOUDSAT VAP.

54 ENVIRONMENTAL SCIENCES↗

Performance Report: A timeline for the synchrotron calibration of AXAF

Presented herein are the known elements of the timeline for synchrotron reflectance calibrations of HRMA witness samples (Section 2). In Section 3, lists of measurements to be done on each witness flat are developed. The elements are then arranged into timelines for the three beamlines we expect to employ in covering the full 50-12,000 eV energy range (Section 4). Although the required AXAF operational range is only 0.1-10 keV, we must calibrate the extent to which radiation just outside this band may contaminate our in-band response. In Section 5, we describe the working relationships which exist with each of the beamlines, and estimate the time available for AXAF measurements on each. From the timelines and the available time, we calculate the number of flats which could be measured in full detail over the duration of the program for each beamline. A suggestion is made regarding a minimum required baselines of witness flats from each element coating run or qualification run to be used in the calibration. We intend that this suggestion open discussion of the issue of witness flat deployment.

Tananbaum, H. D.↗

Laboratory Measurement of Bidirectional Reflectance of Radiometric Tarps

This experiment measured the reflectance of tarps with ground instruments in order to check radiometric calibration, validate atmospheric correction, and predict at-sensor radiance for satellite instruments. The procedure of this experiment is as follows: 1) Assemble laboratory apparatus to duplicate ground reference measurement geometry and satellite measurement geometry; 2) Measure spectral radiance with Optronics OL 750 double monochromator/spectroradiometer; 3) Measure radiance of NIST-calibrated Spectralon panel irradiated by collimated light at incidence angle of calibrated reflectance (20 deg, 30 deg, 40 deg, or 50 deg), viewing normal to panel surface; 4) Measure radiance of Spectralon panel irradiated at incidence angle equal to solar zenith angle at time of overpass; 5) Calculate reflectance of Spectralon panel irradiated at solar zenith angle, viewing normal to panel surface (ground geometry).

Knowlton, Kelly↗

Terra and Aqua MODIS Collection 7 Level 1B Algorithm

MODIS continues to be an important instrument for NASA’s Earth Observing System (EOS). Terra and Aqua MODIS have produced more than 22 and 20 years of global datasets that have significantly helped scientists better understand the Earth’s systems respectively. The MODIS Level-1B (L1B) algorithms use the uncalibrated, geolocated Earth scene observations as input and convert the instrument response into calibrated reflectance and radiance, which are used to generate the downstream science products. The sustained calibration and characterization activities undertaken by the MODIS Characterization Support Team have resulted in several upgrades to the L1B algorithms in order to maintain accurate calibration in the data products. In this paper, we present an overview of the L1B algorithm designated as Collection 7. Various algorithm enhancements both in the reflective bands and thermal bands characterization, are currently under science testing and evaluation. Once applied in data processing (projected in early 2023), they are expected to manifest in improved science products, both in terms of radiometric accuracy and long-term stability.

MODIS↗

Target Calibration: Retro-Reflection Mechanisms at 2 Micron

With the growing use of 2-micrometer eye-safe solid-state laser transmitters in coherent Doppler lidar applications, there is increased interest in the reflectance properties of hard target calibration materials at this wavelength. One of the factors to be considered is the polarization characteristic of the transmitter/receiver. The two fundamental lidar systems are either based upon the backscattering of linearly polarized or circularly polarized light. Consequently, the response of calibration materials to the particular state of polarization of the incident radiation is an important consideration. Ideally the calibration materials should have a similar reflectance response to that of the remote scattering medium that is being observed. Also the material should be most efficiently adapted to the polarization characteristics of the lidar system. There are two measurement parameters that are useful in presenting the characteristics of polarization of reflecting materials. The first is the linear polarization ratio: mu (sub l) =I (sub ol)/I (sub sl), where ol denotes opposite linear and sl denotes same linear. The second is circular polarization ratio: mu (sub c) = I (sub sc)/I (sub oc) where ol denotes opposite circular and sc denotes same circular. Notice that the ratios are inverted with respect to same polarization. It is the relative values of these polarization ratios that are used to characterize the retro-reflectance mechanism. Measurement of these parameters is conveniently obtained by using the Stokes vectors corresponding to the polarized backscatter at and near the retro-angle.

Haner, David A.↗

MODIS Reflective Solar Bands Calibration Improvements for Collection 7

Calibration of Terra and Aqua MODIS reflective solar bands (RSB) has evolved significantly since the launch of the first MODIS instrument on the Terra satellite more than 21 years ago. In NASA’s current Collection 6 and 6.1 Level 1B products (C6/C6.1 L1B), the RSB calibration algorithm continues to rely primarily on the onboard solar diffuser to calibrate the instrument gain. Lunar observations are used to track on-orbit changes in the response versus scan angle (RVS), and data from pseudo-invariant desert sites are used to apply adjustments to the gain and RVS calibration for select bands. The resulting reflectance products have in general shown a very stable performance. In recent years, some performance degradation has been noted for a few bands and algorithm changes have been tested to further improve the calibration accuracy for the upcoming Collection 7 (C7) L1B reprocess. In this paper, we present the MODIS RSB calibration improvements that will be included in C7. Major improvements include: applying polarization correction to the desert data before using it to generateRVS for Terra bands 8, 9, 3, and 10; using ocean scene data and an interband calibration approach to correct for long-term drift of Terra bands 11 and 12; applying an updated crosstalk correction to Terra SWIR bands over the entire mission; and using data from deep convective clouds in Terra SWIR band calibration, including the addition of time-dependent RVS for bands 5 and 26. All other minor calibration changes are also covered. Overall, the reflectance differences at nadir between C6.1 and C7 are within a few percent, though the differences increase in some cases at large scan angles. The Terra visible (3, 8-12) and SWIR bands (5-7, 26) have the most significant improvements. For all other Terra bands and all Aqua bands, the C7-C6.1 differences are mostly within 1%

MODIS↗

In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis

X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. Finally, a Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.

47 OTHER INSTRUMENTATION↗