Search NASA⌕ Search

SEARCH · Search NASA

Results for “reflectometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Extended Bandwidth Spread Spectrum Time Domain Reflectometry Cable Test for Thermal Aging, Low Resistance Fault, and Water Detection

In 2022, researchers at Pacific Northwest National Laboratory (PNNL) used the Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed to characterize spread spectrum time domain reflectometry (SSTDR) and compare the responses of an SSTDR instrument to those of a frequency domain reflectometry (FDR) instrument. Results showed both techniques could detect and locate cable anomalies such as phase-to-phase low resistance and shorts, thermal insulation damage, mechanical insulation damage, and the presence or absence of water in some conditions. The SSTDR tests used a commercial instrument provided by LiveWire Innovations Inc. This commercial instrument performed tests at 6, 12, 24, and 48 MHz bandwidth. The results of these tests were compared to FDR tests where bandwidths could be extended up to 1.3 GHz, although the best responses for cable tests were from 100 to 500 MHz. Lower bandwidth signals can propagate better along the cable while higher bandwidths have higher resolution for impedance change reflections allowing more precise indication of location and separation of anomalies. The 2022 research found that FDR responses were clearer than SSTDR and speculated that a higher bandwidth SSTDR could more successfully detect and locate cable anomalies. One advantage of the SSTDR system investigated was that it was designed for energized online use up to 1,000 volts, which may be a significant advantage for nuclear power plant use. The LiveWire SSTDR instrument is an established product in the rail and aircraft industry and updating the SSTDR hardware parameters is difficult to justify without more conclusive testing. Therefore, a software adjustable laboratory SSTDR instrument was developed by PNNL and was used to test extended bandwidth SSTDR cable tests. Within the ARENA test bed, 42 cable conditions were tested with the PNNL SSTDR, FDR, and the LiveWire SSTDR—each operating at four different bandwidths. Observations and conclusions regarding the relative performance of the three instruments over different bandwidths are note below. Responses of the PNNL SSTDR (at 50 MHz) and the LiveWire SSTDR (at 48 MHz) were similar. The PNNL SSTDR higher frequency bandwidths behaved as expected showing sharper peaks and higher noise. This validated the PNNL SSTDR as a reasonable implementation of the SSTDR technology. Lower bandwidth SSTDR responses (particularly 6 and 12 MHz) may have increased value for use within longer cables but were not particularly effective at identifying anomalous cable behavior in the 100 ft cables tested here. The higher bandwidths of the PNNL SSTDR (50, 100, 200, and 400 MHz) did not provide substantially clearer cable reflectometry responses, but having the higher frequency responses available did add to the cable test evaluation. Strong responses to shorts and low impedance faults between phases were particularly evident in the higher bandwidth PNNL SSTDR and the FDR data. Measurements were repeatable, with similar responses obtained from a thermally aged cable for tests taken a month apart. Signal noise was affected in the unshielded cable by the local in-tray cable arrangement including proximity to metal edges and rungs of the cable tray. Foam isolation of the cable from the tray metal reduced in both FDR and SSTDR responses. Cable condition monitoring in nuclear power plants will likely benefit from both more informative off-line testing methods and from the development of on-line methods for continuous monitoring of cables in use. The LWRS-funded ARENA test bed was a valuable resource for this development and direct comparison of nuclear electrical cable condition monitoring technologies. Test results are targeted to guide industry advancement of testing and monitoring tools for cable aging management.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radio Frequency Field Programable Gate Array Implementation of Reflectometry Cable Monitoring

This document describes the development of a field programable gate array (FPGA) radio frequency system on a chip (RF SoC) adaptation and evaluation of the single-board device to perform both Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR) for offline and online cable testing. The work builds on and leverages the work of Pacific Northwest National Laboratory (PNNL) in airport millimeter wave technology by using the same development hardware employed in that program. The work is performed under sponsorship from the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program and the task objective is to confirm and demonstrate feasibility to adapt FPGA technology for a cost-effective multiplexed single-board electronic module to perform cable tests that are equivalent to commercial and laboratory test instruments for FDR and SSTDR cable tests. The developed 2-channel (extendable to 7 channels) system was compared to dedicated and proven test instruments and shown to produce equivalent results on a range of cables and with a range of damage types. The FPGA reflectometry test board is one of several technologies that could facilitate implementation of online monitoring of safety critical cable systems.

42 ENGINEERING↗

Understanding the Dissolution and Passivation of an Aluminum Electrode during Electrocoagulation of Groundwater Using Neutron and X-ray Reflectometry

An aluminum (Al)-based electrocoagulation (EC) system can effectively remove dissolved silica and hardness in groundwater. The effectiveness of Al-EC in terms of pollutant removal, Faradaic efficiency, and energy consumption depends on the interfacial electrolysis or passivation of the electrode in water. Thus, understanding the electrolysis reaction at the liquid/electrode interface during operation is important for sustainable EC deployment. Here, a continuous flow-through Al-EC system was tested with various groundwater simulants, i.e., chloride (Cl – )-based, sulfate (SO 4 2– )-based, and mixed solutions. High pollutant removal with low energy consumption was observed in Cl – -based groundwater treatment, while low pollutant removal with high energy consumption was observed in SO 4 2– -based groundwater. For example, the required energy per unit mass of Al dosing in SO 4 2– -based groundwater is three times higher than that in Cl – -based groundwater at 10 mA/cm 2 . However, increasing the Cl – concentration significantly reduces this energy demand. In SO 4 2– -based groundwater, the silicate removal efficiency drops from 85.1% to 24.0% compared to that for Cl – -based groundwater, while Mg 2+ and Ca 2+ removal efficiencies decrease to 0.6% from 15.8% and 5.7% from 44.8%, respectively. To better understand this EC performance, we used in situ neutron reflectometry (NR) to examine the interfacial dynamics of Al dissolution and passivation at a 100 nm scale occurring on the surface of the sacrificial Al electrodes during EC. Ex situ X-ray reflectometry (XRR) was also used to support the in situ NR results. Both NR and XRR results revealed that Al dissolution is influenced by the presence of Cl – in the simulants, while a passivating layer forms on the electrode in a SO 4 2– -based solution. In the Cl – -based solution, anodic Al dissolution occurred locally and inhomogeneously across the surface of the Al anode film, resulting in a localized thickness reduction over time. In the SO 4 2– -based solution, no apparent dissolution of the Al anode was identified. Instead, Al underwent oxidation, forming an amorphous Al 2 O 3 surface layer within the Al electrode film that increased in thickness over time. In the mixed solution, both anodic Al dissolution and surface Al 2 O 3 layer formation occurred, indicating that Al dissolution and surface Al 2 O 3 layer formation are attributable to the Cl – and SO 4 2– ions, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Minimization of Measurement Uncertainty in Optical Frequency Domain Reflectometry

Optical frequency domain reflectometry (OFDR) is a technique for interrogating optical fiber sensors to generate relative, quasi-distributed measurements. Although Optical frequency domain reflectometry (OFDR) is increasingly being adopted for aerospace, energy production, and structural monitoring applications, the quantification of uncertainty for OFDR measurements has not been developed beyond sparse empirical relationships. To address this knowledge gap, an uncertainty metric for OFDR measurements was developed. This uncertainty metric was applied to weight the edges between OFDR measurements on directed correlation graphs and analyzed to minimize the cumulative uncertainty. In conclusion, this work is the first to propose an uncertainty metric for OFDR and provides a generalized mathematical framework for optimizing OFDR hardware selection, optical fiber sensor selection, and postprocessing strategy.

42 ENGINEERING↗

Detection and Localization of Disconnections in PV Strings Using Spread-Spectrum Time-Domain Reflectometry

This article describes the novel use of spread-spectrum time-domain reflectometry (SSTDR) for detecting and locating disconnection faults in photovoltaic (PV) power plants. We measure strings of cells and full-sized modules to understand how disconnections affect the reflectometry signature. PV modules correspond to reactive loads and disconnections in a PV string and cause distinguishable and measurable changes in SSTDR responses. Disconnection faults are manually introduced and correctly identified and localized applying the proposed technique. The SSTDR technique can detect and locate disconnects through at least eight 36-cell modules. Using the new technique described in this article, we can both detect and locate the disconnections within a 1-ft resolution, on average.

14 SOLAR ENERGY↗

An Overview of Spread Spectrum Time Domain Reflectometry Responses to Photovoltaic Faults

Spread spectrum time domain reflectometry (SSTDR) is a broadband electrical reflectometry technique that has been used to detect and locate faults on live electrical systems, including photovoltaic systems. In this article, we evaluate the detectability and localizability from both existing literature and our own measurements using SSTDR of open-circuit faults, connection faults, short-circuit faults, ground faults, arc faults, shading faults, bypass diode faults, and accelerated degradation faults in PV cells and mini-modules. Additionally, reflection magnitudes for these faults are compared. Herein, preliminary data on buried and grounded PV cable along with arc fault detection are presented.

14 SOLAR ENERGY↗

Postprocessing for Improved Accuracy and Resolution of Spread Spectrum Time-Domain Reflectometry

Reflectometry, which is commonly used for locating faults on electrical wires, produces sampled time domain signatures with peaks that are often missed due to this sampling. Resultant errors in these sampled peaks translate to errors in calculating the impedance and location of the fault. Typical signal processing methods to improve the accuracy of these sampled peaks have complexity on the order of O(N 2 ). For embedded fault location applications, algorithms with lower complexity are desired. In this article, we introduce three algorithms for improving the accuracy of the peak with a complexity of O(N). Finally, we evaluate these algorithms on the practical case of calculating the velocity of propagation and the characteristic impedance of a photovoltaic (PV) cable using spread spectrum time-domain reflectometry.

47 OTHER INSTRUMENTATION↗

Automated design of an additive manufactured compact broadband antenna for plasma reflectometry

Broadband antennas operating in the gigahertz frequency range are regularly used for plasma reflectometry diagnostics. Due to a lack of space and unique diagnostic constraints, these antennas are often custom in design and frequency range. Recent advances in additive manufacturing of high temperature copper alloys allow for expanded freedom in design of these diagnostic antennas. In this work, a heuristic simulated annealing algorithm is used alongside 3-D finite element simulation to automate the design of a double ridged rectangular horn antenna for a reflectometry diagnostic on the DIII-D tokamak. Optimization of antenna performance given the design constraints results in a compact broadband (6-20+ GHz) antenna design. Measured transmission from the additively manufactured antenna matches simulation within reasonable error, and experimental plasma electron density profiles from the DIII-D high-field side scrape-off layer are shown.

Additive manufacturing↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

New methodology for measuring electron density perturbations caused by plasma coherent modes using profile reflectometry: Magnitudes and radial profiles in DIII-D

New capabilities of fast-sweep frequency-modulated profile reflectometry are explored to measure electron density ne perturbation magnitudes and radial profiles due to plasma coherent modes in DIII-D. The first approach is based on the frequency analysis of phase perturbations associated with high frequency (~MHz) Alfvén eigenmodes (AEs). The measurement of ~5.5 MHz fast-ion-driven global Alfvén eigenmodes (GAEs) is demonstrated in a neutral beam-heated DIII-D plasma. The GAE induced a broad radial distribution of phase perturbations in the profile reflectometer data. Analysis of these data determined the effective cutoff location displacement and the estimated ne fluctuation profile. In the second approach, high resolution ne profiles are used directly to determine the radial structure of ne perturbations due to a neo-classical tearing mode. These new measurements broaden the application of profile reflectometry and advance the development of AE spectroscopy as a tool for non-invasive diagnosis of fast-ion-driven modes in DIII-D and burning plasmas such as ITER.

47 OTHER INSTRUMENTATION↗

Evaluation of the Abel inversion integral in O-mode plasma reflectometry using Chebyshev–Gauss quadrature

The Abel transform is often used to reconstruct plasma density profiles from O-Mode polarized reflectometry diagnostics. However, standard numerical trapezoidal evaluation of the Abel inversion integral can be computationally expensive for a large number of evaluation points, and an endpoint singularity exists on the upper-bound of the integral, which can result in an increased error. In this work, Chebyshev–Gauss quadrature is introduced as a new method to evaluate the Abel inversion integral for the problem of O-Mode plasma reflectometry. Here, the method does not require numerical evaluation of an integral singularity and is shown to have similar accuracy compared to existing methods while being computationally efficient.

47 OTHER INSTRUMENTATION↗

Three-dimensional hard X-ray ptychographic reflectometry imaging on extended mesoscopic surface structures

Many nanodevices and quantum devices, with their sizes often spanning from millimeters down to sub-nanometer, have intricate low-dimensional, non-uniform, or hierarchical structures on surfaces and interfaces. Since their functionalities are dependent on these structures, high-resolution surface-sensitive characterization becomes imperative to gain a comprehensive understanding of the function–structure relationship. We thus developed hard x-ray ptychographic reflectometry imaging, a new technique that merges the high-resolution two-dimensional imaging capabilities of hard x-ray ptychography for extended objects, with the high-resolution depth profiling capabilities of x-ray reflectivity for layered structures. The synergy of these two methods fully leverages both amplitude and phase information from ptychography reconstruction to not only reveal surface topography and localized structures, such as shapes and electron densities, but also yields statistical details, such as interfacial roughness that is not readily accessible through coherent imaging solely. The hard x-ray ptychographic reflectometry imaging is well-suited for three-dimensional imaging of mesoscopic samples, particularly those comprising planar or layered nanostructures on opaque supports, and could also offer a high-resolution surface metrology and defect analysis on semiconductor devices, such as integrated nanocircuits and lithographic photomasks for microchip fabrications.

47 OTHER INSTRUMENTATION↗

Deposition and characterization of α-Fe 2 O 3 /Pd thin films for neutron reflectometry studies

Here, we report deposition of hematite/Pd thin films on silicon wafers via radio frequency (RF) magnetron sputtering and subsequent characterization for future in situ neutron reflectometry studies. Following deposition, the hematite/Pd thin films were characterized as prepared and after annealing in air for 2h at 400, 500, and 600 °C, respectively. Raman spectroscopy, grazing incidence x-ray diffraction, and neutron reflectometry (NR) were used to characterize the structure and chemical compositions of the thin films. The results indicate that pure α-Fe 2 O 3 (hematite) films were produced, free from other iron oxide phases and impurities. NR data reveal that one intermediate layer between the Pd layer and the hematite layer was formed during sputtering deposition processes. The fitted scattering length density (SLD) of the as-deposited hematite layer is 70% of the theoretical SLD value, indicating that the grains are loosely packed in the RF-deposited hematite films. After annealing at elevated temperatures, the hematite films show increased SLD values but remain comparable to that of preannealed.

36 MATERIALS SCIENCE↗

Neutron detector development for high-rate neutron reflectometry at the Second Target Station of Oak Ridge National Laboratory

The Second Target Station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) is expected to produce a neutron source that is the brightest in the world, having a significantly higher peak brightness compared to the First Target Station (FTS), where the reflectometry instruments already fall short of being able to handle the highest available flux by a factor of ~100. The neutron reflectometers at the SNS FTS are not suitable for the reflectometers planned for the SNS STS because of its unprecedentedly high peak brightness and the already limited capabilities of these instruments at high count rates. Furthermore, the high rate instruments that are now under development are expected to underperform with regard to gamma sensitivity, meaning that signal-to-noise will be reduced and they will be unable to measure weaker reflectance phenomena in the presence of the significant prompt gamma flash at SNS. To address these challenges, we conducted research to advances associated instruments, techniques, and capabilities for the SNS STS reflectometers. More specifically, we investigated the development of a scalable, 2-D positive-sensitive, pixelated, scintillator-based neutron detector module based on a newly developed scintillator. The work has potential for impact on future neutron reflectometry instruments and neutron science performed at the SNS STS. In particular, the improved background rejection capability of the developed detector could extend the available experimental dynamic Q range, allowing it to measure weak reflectance phenomena.

reflectometry, radiation instrumentation, neutron ↗

Frequency Domain Reflectometry (FDR) Simulation Techniques for Digital Twin Representation of an Electrical Cable

Simulation of cable system response to frequency domain reflectometry (FDR) tests can be instrumental to understanding these tests and the nature and influence of various cable anomalies on test signatures. Reflectometry simulations are based upon a finite element representation of cable conductors and insulation to produce an S-parameter at each evaluated frequency. The aggregate collection of cable model S-parameters can simulate the influence on a test signal injected into a physical cable. Such an approach was undertaken in this work to produce a digital twin simulation of a low-voltage electrical cable. The electrical cable digital twin examined the influence of test simulation parameters and the relative influence of cable anomalies, including thermal aging, water or moisture exposure, water or moisture ingress, and other anomalies. The digital twin in this work included modeling of the conductors, insulation, jacket, and surrounding environment (air, water, etc.). The digital twin could be expanded to include cable bends, junctions and splices, branch or T systems, and termination impedances of motors or instruments. Observations and conclusions of this work include: 1. Fully 3D digital twin simulation of an electrical cable using an FDR approach is possible. However, there are tradeoffs between simulation fidelity and solution time, which must be balanced to ensure the simulation solves in an adequate amount of time (e.g., less than 20 minutes). Simulation parameters to balance include frequency bandwidth, number of frequencies, mesh density, connection impedance, and permittivity tolerance. 2. The digital twin simulation can explain FDR sensitivity to various cable anomalies, including entry and exit from an oven or water bath. 3. The digital twin simulation FDR response attenuates with distance along the cable and is further affected by the frequency bandwidth, which is similar to that observed with physical measurements. 4. The resolution of the digital twin FDR peaks increased with increasing bandwidth and with increasing number of frequencies, again similar to physical measurements. 5. The presence of multiple anomalies in the digital twin does not substantially attenuate the FDR response to anomalies located beyond the first encountered anomaly and impedance mismatch. 6. Spectral variation of the permittivity did not have a significant effect on the FDR response compared to a fixed nominal value. 7. Extension of the digital twin to 1000 ft still allowed for detection of distal anomalies near the far end of the electrical cable from the instrument connection point. 8. The ARENA test bed facilitates efficient NDE evaluations of well understood cable anomalies with various NDE methods without risking actual plant damage.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗

Electron density profile and associated fluctuation measurements using a microwave reflectometry diagnostic on Helically Symmetric eXperiment (HSX)

Abstract A dual-band frequency-modulated reflectometry is employed on the Helically Symmetric eXperiment (HSX) stellarator. This system equips a fast PIN switch to alternate the frequency source between two voltage-controlled oscillators, providing an operational frequency range from 14.5 GHz to 25.5 GHz. A monostatic antenna geometry and an ellipsoidal mirror are implemented in the vessel of HSX, where the polarization of the transmitted microwave can be switched between O- and X-mode to accommodate the magnetic field and plasma density. Although the original system was designed for density fluctuation measurement, significant efforts have been undertaken to improve the system performance and to realize the density profile inversion. Recent improvements of the system reported here include calibration of the dispersion in the transmission line, optimization of the waveform, and implementation of the Choi-Williams time–frequency distribution for spectral analysis. In this paper, we present the optimization of the reflectometry system along with first experimental measurements of the density profile and observations of fluctuations during gas puffing experiments.

Han, X. (ORCID:0000000184986433)↗

Effect of Measurement Temperature on Electrical Cable Frequency Domain Reflectometry Response

In nuclear power plants, electrical cables are exposed to stressors, such as elevated temperature and radiation. Evaluation of the effect of stressors on the lifetime of electrical cables can be conducted using offline electrical reflectometry techniques, such as frequency domain reflectometry (FDR). However, recent work has raised the concern that FDR measurements at temperatures higher than ambient may diminish or reduce the response due to stressors, potentially leading to incorrect predictions of electrical cable damage and lifetime. In this work, we explore the FDR response of an electrical cable exposed to an oven-based thermal stressor up to 140°C, including both ramping up and ramping down temperature. It was observed that, for both the oven entrance and exit, an increase in the FDR measurement temperature led to a decrease in the FDR reflection coefficient. In particular, it was found that the reflection coefficient at the oven entrance decreased from the ambient measurement by approximately 7%, 22%, and 36% at a temperature of 60°C, 100°C, and 140°C, respectively.

Spencer, Mychal P.↗