Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗

Multiple Critical Unresolved Region Integral Experiment (MCURIE): A Proposed Integral Critical Experimental Framework for Unresolved Region and Intermediate Energies

The Critical Unresolved Region Integral Experiment (CURIE) critical experiment was performed at the National Criticality Experiments Research Center (NCERC) at the Device Assembly Facility (DAF) at the Nevada Nuclear Security Sites (NNSS) in 2020. The objective of CURIE was to improve the quality of integral nuclear data in the uranium-235 ( 235 U) unresolved resonance region (URR) by performing benchmark integral experiments that were sensitive to the URR energy ranges. The CURIE experiment was evaluated for the International Criticality Safety Benchmark Evaluation Project (ICSBEP) handbook and the benchmark evaluation was accepted in 2022. The URR is a region within the intermediate neutron energy range (the intermediate energy ranges from 0.7 eV to 100 keV). The observed resonance structure in neutron cross sections is due to discrete energy levels in the nucleus and are characterized by resonance parameters. In the URR region, the resonance parameters are only partially resolved as the resolution of the experiment techniques becomes comparable to the average width of the resonances themselves, and the resonances are so close to one another that the structure cannot be determined empirically. The ENDF/B-VIII.0 and JEFF-3.3 nuclear data libraries define the URR as beginning at 2.25 keV and continuing until 25 keV. There are minimal intermediate neutron energy benchmarks available in the ICSBEP benchmark handbook, and aside from CURIE there are none that are highly sensitive in the URR energy region. There is a current need for additional experiments sensitive to the URR energy region. There is a new proposed subgroup for the Organization for Economic Co-operation and Development and Nuclear Energy Agency (OECD NEA) Working Party on International Nuclear Data Evaluation Cooperation (WPEC), so any new models or information will need experimental validation and testing. The NEA Working Party on Nuclear Criticality Safety (WPNCS) recent experimental needs and priority list includes intermediate energy 235 U and 238 U experiments, as does the recent Integral Experiments to Address Nuclear Criticality Safety Needs Meeting (May 2023). A variant on the original CURIE experiment called the Multiple Critical Unresolved Region Integral Experiment (MCURIE) is proposed to provide further investigation of the intermediate and URR energy region for uranium. MCURIE will utilize existing fuels at NCERC but use alternative moderators and reflectors to modify the neutron absorption, scattering, and fission spectra of the experiments, allowing for precise targeting of nuclear data sensitivities. The overall goal of MCURIE is to develop a framework for designing and performing integral benchmark experiments with high sensitivities in the intermediate and URR energy regions for nuclear data validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast-Spectrum Critical Assemblies with a Pb-HEU Core Surrounded by a Copper Reflector

The Department of Energy invests tens of millions of dollars each year to develop the next generation of nuclear engineering modeling & simulation (M&S) tools. These M&S tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers become more powerful, we are able to enhance resolution in our calculations. This improved resolution is taking us to a point where the limitations of simulation capability are in the quality of data, including our ability to quantify the uncertainty and sensitivity of the data. In order to accurately model systems of interest, the industry must improve key nuclear data measurements and our confidence of how well we understand the data. Thus, M&S tools need evaluated and quality-assured experimental data for validation purposes. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles benchmark experiment data in a handbook that can be used by criticality safety engineers to validate computer codes and cross-section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. Figure 1 organizes all the benchmark evaluations that have been performed by the isotope of interest, in this case Pb, and the neutron energy within the system. Compared to other isotopes of interest for nuclear applications, there are few benchmark evaluations for Pb systems. This has caused the latest nuclear cross-section libraries to over/underestimate changes in the neutron population compared to experimental results. Therefore, this evaluation fills an important knowledge gap in benchmark evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗