Search NASA⌕ Search

SEARCH · Search NASA

Results for “refractive index”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hybrid interferometric diagnostic for the refractive index measurement across nearly discrete shock waves

The measurement of high temperature gas properties is key for characterizing high speed flows. Nearly discrete changes in density across shock waves, in particular, are difficult to resolve through traditional fringe-counting interferometric methods. Existing techniques for estimating large fringe jumps are either resolution limited or require specialized window configurations. In this Letter, we describe a unique hybrid interferometric technique that combines narrowband fringes for high resolution and broadband fringes as an absolute reference to measure changes in refractive index with a resolution of up to 7 × 10 −8 across nearly discrete index changes of up to 1.5 × 10 −4 . By capturing fringes with an ultrahigh-speed camera, the refractive index changes across discrete shock fronts can be estimated inside a shock tube with high accuracy and time resolution. First, a novel hybrid calibration method for tracking finite fringes is discussed. Next, this technique is used to measure the post-initial-shock refractive indices for Mach 2.7 to 4.2 flows (pressures from 90.4 to 228.4 kPa). Results are then compared with theoretical values showing agreement within 2%.

Wang, Gwendolyn T. (ORCID:000000016271893X)↗

High optical transparency polymer aerogels using low refractive index monomers

A method of producing a polymer aerogel includes dissolving precursors into a solvent, wherein the precursors include monomers, crosslinkers, a controlling agent and an initiator to form a precursor solution, wherein at least one of the monomers or at least one of the crosslinkers has a refractive index of 1.5 or lower, polymerizing the precursor solution to form a gel polymer, and removing the solvent from the gel polymer to produce the polymer aerogel. A method of producing a polymer aerogel include dissolving precursors into a solvent, wherein the precursors include monomers, crosslinkers, a controlling agent and an initiator to form a precursor solution, polymerizing the precursor solution to form a gel polymer, removing the solvent from the gel polymer to produce the polymer aerogel, and reducing a refractive index of one of either the gel polymer or the polymer aerogel.

Bulger, Eli↗

Zero-crosstalk silicon photonic refractive index sensor with subwavelength gratings

Abstract Silicon photonic index sensors have received significant attention for label-free bio and gas-sensing applications, offering cost-effective and scalable solutions. Here, we introduce an ultra-compact silicon photonic refractive index sensor that leverages zero-crosstalk singularity responses enabled by subwavelength gratings. The subwavelength gratings are precisely engineered to achieve an anisotropic perturbation-led zero-crosstalk, resulting in a single transmission dip singularity in the spectrum that is independent of device length. The sensor is optimized for the transverse magnetic mode operation, where the subwavelength gratings are arranged perpendicular to the propagation direction to support a leaky-like mode and maximize the evanescent field interaction with the analyte space. Experimental results demonstrate a high wavelength sensitivity of − 410 nm/RIU and an intensity sensitivity of 395 dB/RIU, with a compact device footprint of approximately 82.8 μm 2 . Distinct from other resonant and interferometric sensors, our approach provides an FSR-free single-dip spectral response on a small device footprint, overcoming common challenges faced by traditional sensors, such as signal/phase ambiguity, sensitivity fading, limited detection range, and the necessity for large device footprints. This makes our sensor ideal for simplified intensity interrogation. The proposed sensor holds promise for a range of on-chip refractive index sensing applications, from gas to biochemical detection, representing a significant step towards efficient and miniaturized photonic sensing solutions. Graphical Abstract

Materials Science↗

Modulational instability in oppositely doubled-doped directed couplers with a non-kerr-like nonlinear refractive-index change

We theoretically investigate modulation instability (MI) in a two-core nonlinear oppositely directed coupler with a negative-index material channel in the presence of a non-kerr-like nonlinear refractive-index change. Using linear stability analysis, we obtain an expression for the instability gain. It is found that the MI in the nonlinear two-core oppositely directed coupler is significantly influenced by the ratio of the forward- to backward-propagating wave power, nonlinearity, power and saturation. In the normal dispersion regime, the septic nonlinearity is found to suppress the MI by reducing both the gain and width of the instability nonlinearity. But in anomalous dispersion regime, the situation is different because septic nonlinearity enhances the MI by increasing both the gain and width of MI. The increase of septic nonlinearity both in normal and anomalous dispersion regimes increases the gain of the instability nonlinearity. Thus, we report new ways to generate and manipulate the MI and solitons in two-core oppositely directed couplers with a particular emphasis on a negative-index material (NIM) channel in presence of septic nonlinearity.

36 MATERIALS SCIENCE↗

High speed laser-induced refractive index change in ophthalmic HEMA hydrogel using a line focus

Laser-induced refractive index change (LIRIC) techniques typically focus femtosecond laser pulses to a tight spot to achieve the high intensities required to alter ophthalmic materials. A line-focus implementation using 800 nm pulses at 1 kHz repetition rate has been shown to greatly increase the effective writing speed of the process, but the high pulse energies used led to nonlinear propagation effects, presenting challenges for the fabrication of ophthalmic correctors. By taking advantage of the lower effective order of multiphoton absorption for 514 nm pulses, power levels may be reduced, allowing overlapped pulse writing. We demonstrate that this allows high-quality phase bars and devices to be made at high speeds.

Manning, Zachary A. [University of Rochester, NY (↗

High Refractive Index Adhesives for Laser Glass Cladding Applications (ABBREVIATED Report)

To eliminate parasitic light oscillations (amplified spontaneous emission (ASE)), high energy laser systems often utilize polymeric materials to adhere optically absorptive cladding materials to laser gain media (glass or crystal). Most of these polymeric optical adhesives are index matched to lower index gain media, and there was no capability to achieve refractive indices (RI) greater than 1.60 with low color, while also maintaining mechanical compliance to serve as adhesives for cladding applications. The completion of LDRD 23-FS-043 shows we can chemically develop novel suitable adhesive candidates with refractive indices above 1.64 at 532 nm while also exhibiting Shore A hardness between 50-90, with high optical clarity, low color, and minimal haze for films ~1-2 mm thick (84 %Transmission at 532 nm). This will enable us to begin mapping a process space to allow future customizable adhesive formulations for building a variety of laser systems with tunable refractive index matching for various gain and cladding media.

36 MATERIALS SCIENCE↗

Low refractive index surface layers and related methods

The disclosure relates to a method for forming a low refractive index layer on a substrate. The method generally includes (a) applying a block copolymer layer on a substrate, the block copolymer including a polar polymeric block and a non-polar polymeric block; (b) swelling the block copolymer layer with a solvent to increase the block copolymer layer thickness; (c) depositing a metal oxide or metalloid oxide layer on polar polymeric blocks of the block copolymer layer; and (d) removing the block copolymer layer from the substrate, thereby forming a porous metal oxide or metalloid oxide layer on the substrate.

Shevchenko, Elena↗

3D printed transparent ceramic YAG laser rods: Matching the core-clad refractive index

Yttrium Aluminum Garnet (YAG) solid state laser gain media rods with an active Neodymium-doped core and an optically-clear cladding region were additively manufactured via direct-ink-writing (DIW), followed by sintering and hot isostatic pressing to form fully dense optical ceramics. Lutetium and Gadolinium were chosen as optically-inert co-doping ions in the clad to match the increase in refractive index caused by the Neodymium in the core. Additionally, either 11.6% Lutetium or 3.8% Gadolinium can be used to match the index change from 2% neodymium; however, differences in diffusion distances across the core-clad interface lead to large fluctuations in index in that region. These index fluctuations can be minimized either by matching dopants with similar diffusion distances, or by implementing a gradual gradient in the doping profile, possible through DIW, rather than a sharp compositional interface attainable via more standard fabrication methods. This improvement in index homogeneity resulted in a 40% improvement in lasing performance compared with that of a core-clad rod fabricated with a sharp interface between the doped and undoped regions.

36 MATERIALS SCIENCE↗

Refractive Index and Abbe Number Tuning via 3D Printable Optical Quality Silica–Titania–Germania Glasses

The development of optical quality GeO 2 –TiO 2 –SiO 2 glasses compatible with direct ink writing (DIW) 3D printing is reported in this study. Colloidal GeO 2 and TiO 2 –SiO 2 core–shell feedstocks are prepared by a sol–gel method and converted to printable inks for DIW. Printed inks are subsequently densified to glass using heat treatment at temperatures up to 1100 °C in air. A series of print‐compatible glass compositions are prepared, yielding transparent glass with the highest refractive index n = 1.576. Herein, it is shown that more TiO 2 can be incorporated into the glass without haziness or scattering through the addition of GeO 2 . The mechanisms for this are discussed, and it is shown that crystallization persists in these glasses despite the lack of visible light scattering. Finally, the combination of both TiO 2 and GeO 2 into a ternary glass also is used to independently tune the dispersion properties of the glass, as demonstrated by measured refractive indices and Abbe numbers, which has potential implications for 3D‐printed optics.

36 MATERIALS SCIENCE↗

Interferometric measurements of refractive index and dispersion at high pressure

Abstract We describe a high precision interferometer system to measure the pressure dependence of the refractive index and its dispersion in the diamond anvil cell (DAC). The reflective Fabry–Perot fringe patterns created by both a white light and a monochromatic beam are recorded to determine both the sample thickness and its index at the laser wavelength and to characterize the dispersion in the visible range. Advances in sample preparation, optical setup, and data analysis enable us to achieve $$10^{-4}$$ 10 - 4 random uncertainty, demonstrated with an air sample, a factor of five improvement over the best previous DAC measurement. New data on $${\text{H}}_{2}\text{O}$$ H 2 O liquid water and ice VI up to 2.21 GPa at room temperature illustrate how higher precision measurements of the index and its optical dispersion open up new opportunities to reveal subtle changes in the electronic structure of water at high pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mutual Diffusion Coefficients and Refractive Index Increments of K 2 SO 4 (aq) at 298.15 K from Rayleigh Interferometry

Here, isothermal mutual diffusion coefficients (interdiffusion coefficients) were measured for K 2 SO 4 (aq) at 298.15 ± 0.005 K, at numerous concentrations ranging from dilute solutions to near saturation (0.59648 mol∙dm -3 ; 0.61349 mol∙kg -1 ) under free diffusion boundary conditions, using high precision Rayleigh interferometry. Under the experimental conditions these diffusion coefficients are on the volume-fixed reference frame D v . Two series of experiments were performed, the first using the traditional experimental approach with a mercury lamp source and with the interference patterns being recorded on glass photographic plates, and the second with a He-Ne laser light source and computerized data acquisition using a photodiode array. The results from both series of experiments are in excellent agreement, and generally yield diffusion coefficients precise to at least 0.002 x 10 -9 m 2 ∙s 1 (0.15% to 0.19%) and in most cases to 0.001 x 10 -9 m 2 ∙s -1 (0.07% to 0.1%). These experiments also yield accurate values of the refractive index differences for the solution pairs used in the diffusion experiments. The new diffusion coefficients are compared to two sets of published values of diffusion coefficients for K 2 SO 4 (aq) which are somewhat discrepant from each other. This study extends and complements our earlier work on the diffusion coefficients of the most common brine salts: NaCl(aq), KCl(aq), MgCl 2 (aq), CaCl 2 (aq), Na 2 SO 4 (aq), ] MgSO 4 (aq), NaHCO 3 (aq), and KHCO 3 (aq) at 298.15 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time measurement of parametric influences on the refractive index and length changes in silica optical fibers

In this paper, we present a simple cascaded Fabry-Perot interferometer (FPI) that can be used to measure in real-time the refractive index (RI) and length variation in silica optical fibers caused due to external physical parameters, such as temperature, strain, and radiation. As a proof-of-concept, we experimentally demonstrate real-time monitoring of temperature effects on the RI and length and measure the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) by using the cascaded FPI within a temperature range of 21–486°C. The experimental results provide a TEC of 5.53 × 10 −7 /°C and TOC of 4.28 × 10 −6 /°C within the specified temperature range. Such a simple cascaded FPI structure will enable the design of optical sensors to correct for measurement errors by understanding the change in RI and length of optical fiber caused by environment parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational Determination of the Refractive Index of TATB, LLM-105, β-HMX, & α-RDX

In this study, we use Materials Studio CASTEP, an ab initio quantum mechanical (QM) program employing density functional theory (DFT), to compute the refractive index (RI) of solid energetic materials, specifically, PETN (tetragonal phase), TATB, LLM-105, β-HMX, and α-RDX. The use of quantum mechanical DFT methods affords the investigation of the optical mate rial properties of a system without the need for any experimental input. The RI values of PETN and TATB have been experimentally determined previously and are compared here to the QM derived RI values as validation of the theoretical approach in determining material optical proper ties. To date, experimental measurements to determine the RI values for LLM-105 have yet to be determined. This fact obviates the need to determine LLM-105 RI values using quantum mechanical means.

36 MATERIALS SCIENCE↗

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Engineering cellular metabolism for targeted biosynthesis can require extensive design-build-test-learn (DBTL) cycles as the engineer works around the cell's survival requirements. Alternatively, carrying out DBTL cycles in cell-free environments can accelerate this process and alleviate concerns with host compatibility. A promising approach to cell-free metabolic engineering (CFME) leverages metabolically active crude cell extracts as platforms for biomanufacturing and for rapidly discovering and prototyping modified proteins and pathways. Realizing these capabilities and optimizing CFME performance requires methods to characterize the metabolome of lysate-based cell-free platforms. That is, analytical tools are necessary for monitoring improvements in targeted metabolite conversions and in elucidating alterations to metabolite flux when manipulating lysate metabolism. In this work, metabolite analyses using high-performance liquid chromatography (HPLC) coupled with either optical or mass spectrometric detection were applied to characterize metabolite production and flux in E. coli S30 lysates. Specifically, this report describes the preparation of samples from CFME lysates for HPLC analyses using refractive index detection (RID) to quantify the generation of central metabolic intermediates and by-products in the conversion of low-cost substrates (i.e., glucose) to various high-value products. The analysis of metabolite conversion in CFME reactions fed with 13 C-labeled glucose through reversed-phase liquid chromatography coupled to tandem mass spectrometry (MS/MS), a powerful tool for characterizing specific metabolite yields and lysate metabolic flux from starting materials, is also presented. Altogether, applying these analytical methods to CFME lysate metabolism enables the advancement of these systems as alternative platforms for executing faster or novel metabolic engineering tasks.

59 BASIC BIOLOGICAL SCIENCES↗

Ray-tracing image simulations of transparent objects with complex shape and inhomogeneous refractive index

Optical images of transparent three-dimensional objects can be different from a replica of the object’s cross section in the image plane, due to refraction at the surface or in the body of the object. Simulations of the object’s image are thus needed for the visualization and validation of physical models. We report ray tracing image simulations that achieved high physical fidelity, reproducing optical behaviors and image features not rendered in previous studies. We replicated brightfield microscopy images of drops with complex shapes, and images of pressure and shock waves traveling inside them. For high physical fidelity, the simulations must replicate the spatial and angular distribution of illumination rays, and both the experiment and the simulation must be designed for accurate optical modeling. The simulations are highly sensitive to the properties of the drops and can be used to diagnose and refine fluid dynamics models. The simulated images can also be optimized to extract multiple 3D properties from experimental images. Compared to specialized single-shot 3D imaging methods, this approach has the advantage that it preserves the experimental simplicity, the high resolution, and the visual interpretability characteristic to basic optical imaging. The techniques introduced here are directly applicable to optical microscopy, so they can be used in other fields, such as microfluidics and biology, to expand the type and the accuracy of three-dimensional information that can be extracted from basic optical images.

Cavitation↗