Search NASA⌕ Search

SEARCH · Search NASA

Results for “refrigerants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Bubble Point Measurements of Three Binary Mixtures of Refrigerants: R-32/1234yf, R-32/1234ze(E), and R-1132a/1234yf

In this article, bubble point pressures of three binary mixtures at two compositions each have been measured utilizing a static method. The mixtures studied were difluoromethane + 2,3,3,3-tetrafluoroprop-1-ene (R-32/1234yf), difluoromethane + (E)-1,3,3,3-tetrafluoroprop-1-ene (R-32/1234ze(E)), and 1,1-difluoroethene + 2,3,3,3-tetrafluoroprop-1-ene (R-1132a/1234yf). For all of the mixtures, the minimum temperature measured was 270 K. The maximum temperatures measured for the R-32/1234ze(E), R-32/1234yf, and R-1132a/1234yf mixtures were 360, 345, and 325 K, respectively. A total of 100 bubble point pressures are reported and compared to available literature data relative to the REFPROP database. Lemmon, E. W. [ NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, 10.0; National Institute of Standards and Technology, Standard Reference Data Program: Gaithersburg, 2018]. Additionally, the bubble point pressures obtained in this study are modeled using the perturbed-chain statistical associating fluid theory (PC-SAFT) equation of state. The PC-SAFT model parameters, as well as deviations of this work and literature data from the model, are reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Refrigerants for a Sustainable Future

Worldwide use of high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants for space conditioning and food storage results in significant equivalent greenhouse gas (GHG) emissions. This is further exacerbated in developed countries by the current transition from hydrochlorofluorocarbon (HCFC) refrigerants to HFC refrigerants. Under the Kigali amendment to the Montreal Protocol, the proposed phase-out of currently used HFC and HCFC refrigerants has initiated a re-evaluation of some pre-existing refrigerants as well as the development and evaluation of new refrigerants. Making the ideal refrigerant selections for heating, ventilation, air-conditioning, and refrigeration (HVAC&R) applications is thereby difficult in an already overabundant refrigerants market. In this paper, a study of key parameters required of a good refrigerant is conducted, followed by the analysis of refrigerants desired and refrigerants used in two major sectors of the HVAC&R industry, namely commercial refrigeration and residential air-conditioning and heat pumps. Finally, keeping in consideration the global environmental regulations and safety standards, a recommendation of the most suitable refrigerants in both sectors has been made.

54 ENVIRONMENTAL SCIENCES↗

Low-GWP Refrigerants Status and Outlook

Refrigeration - including air conditioning (AC) – contributes substantially to the modern life of the 21st century and its economy. The food cold chain, air conditioning, healthcare and energy are examples of sectors for which refrigeration is indispensable. About 5 billion refrigeration systems – of different types and sizes– operate worldwide in different applications [1]. The dominant share of equipment providing refrigeration operate on the vapor-compression-cycle principle and use fluorocarbon refrigerants. Concerns about the environmental safety have become the driving force for refrigerant changes within the last 35 years. The phased-out schedule of stratospheric-ozone-depleting fluids was first formulated by the Montreal Protocol (MP) in 1987 and was made more stringent during the follow-up international meetings [2]. The affected chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigerants were largely replaced by hydrofluorocarbons (HFCs).The 2016 Kigali Amendment to the MP [3] responses to the concerns about the Earth climate change. The refrigeration and AC sectors are attributed with about 7.8 % of global greenhouse gas emissions [4]. This contribution comes in the form of direct effect, which is related to refrigerant emissions from refrigeration systems (37 %), and in the form of indirect effect, which is related to CO2 emissions from fossil fuel power plants producing electricity to power refrigeration systems (63 %) [4]. The Kigali Amendment aims at reducing the direct effect. The effect a given molecule has on the climate change is quantified in a simplified manner by its Global Warming Potential (GWP), a relative index referencing the effect produced to that of the same mass of carbon dioxide released to the atmosphere. By definition, GWP of carbon dioxide is equal to one.While HFC refrigerants have on average a lower GWP than the CFCs and HCFCs they replaced, they are still potent greenhouse gases (GHGs). The Kigali Amendment phases down the use of HFCs by imposing a schedule for reducing a weighted GWP value to be implemented by a country through the year 2047 (Figure 1). It provides four paths depending on the country location and category assigned in the MP, and also prescribes a method for establishing the baseline consumption used for calculating GWP reductions. For developing countries, it is expected to bring the weighed GWP across all refrigeration applications down to about 300 from the baseline value of about 2000. The implementation of Kigali Amendment aims at reducing the future warming due to HFCs from the range of 0.3 °C to 0.5 °C to less than 0.1 °C [5]. While this reduction may seem to be small, it must be viewed in the context of the 2015 Paris Agreement [6], which calls for holding global warming to well below 2 °C and pursuing to limit global warming to 1.5 °C relative to pre-industrial levels [6]. Considering that average global temperatures reached 1 °C above pre-industrial levels for the first time in 2015 [7], the Earth is already within 1 °C of the “2 °C limit”.The low-GWP requirement narrows the pool of fluids that can be considered for application as a refrigerant [8]. This Informatory Note discusses low-GWP refrigerant options for major applications and presents their selection merits.

Yana Motta, Samuel↗

Energy Efficiency and Performance Evaluation of Self-Contained, Medium Temperature, Reach-In Refrigerated Display Cases

This project was part of an effort by Commonwealth Edison Company (ComEd) to evaluate the energy and peak demand saving potential of emerging technologies in the Chicago area. This document focuses on the assessment of energy-efficient, medium-temperature, self-contained refrigerated display cases utilizing environmentally friendly refrigerants. The results of this evaluation will be considered by CLEAResult to develop a new energy efficiency rebate measure for ComEd's incentive programs. This rebate measure will become an addition to the Technical Reference Manual (TRM). In 2016, the United Nations passed the Kigali Montreal Protocol Amendment which placed restrictions on certain types of refrigerants. In compliance with this amendment, the US Environmental Protection Agency (EPA) placed a ban on the manufacture of refrigeration systems using hydrofluorocarbons including R134a starting in January 2020. Although the ban has halted manufacture, the EPA continues to allow the use of these refrigerants. Therefore, it is critical to provide incentives for replacing these refrigerants with other environmentally friendly and energy-efficient alternatives. The energy-efficient refrigerator cases evaluated here (referred to as EE Case A and B) contain environmentally-friendly refrigerants in compliance with the EPA hydrofluorocarbon ban. These consist of natural refrigerant propane (R290), and HFC drop-in hydrofluoroolefin R513a, respectively. These cases also contain other energy-efficient components including efficient lighting, more robust evaporator and condenser fans and different-sized heat exchangers. EE Case A is also built with materials that better insulate the case, which improves energy efficiency. To ascertain the energy efficiency contribution of these design components, the consumption of the evaporator and condenser fan motors, compressor, and lighting/controller were evaluated individually. The medium-temperature, self-contained reach-in refrigerated display case was selected due to its widespread use in convenience stores and small supermarkets. Self-contained refrigeration has also seen increased use in restaurants due to curbside pickup during the COVID-19 pandemic. For this study, the refrigerated display cases' performance was evaluated in a controlled environmental chamber at representative indoor dry-bulb and humidity conditions found in supermarkets within ComEd's service territory climate zone. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 method of testing. However, modifications to the ANSI/ASHRAE test methodology were implemented to better represent customer operation of the units. In addition to the indoor supermarket conditions, the cases were also evaluated at the "upper target," or environmental conditions used in ANSI/ASHRAE 72-2018. The case total power and case components were metered to obtain their daily power (kW) and energy consumption(kWh). The cases were filled with thermal filler mass to replicate thermal mass of product loading. Additionally, product simulators were used to provide product temperature information. Door actuators were mounted to each of the cases' three doors to replicate regular door openings and effects of shopper traffic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Completion of initial reduced-order model for flammable refrigerant dispersal in residential spaces

Environmental regulations aimed at reducing global warming impacts of HVAC&R refrigerants have resulted in the phase-out of chlorofluorocarbons (CFCs) in 2010 and hydrochlorofluorocarbons (HCFCs) by 2030 in developed countries with additional restrictions on the use of hydrofluorocarbons (HFCs) set to take effect in 2036. Many of the remaining alternative refrigerants that have lower global warming potential (GWP) and that are suitable for use in HVAC&R systems (e.g., propane, difluoromethane) are flammable to some degree. Flammable refrigerants introduce new challenges and hazards to property and personal safety related to potential deflagration during system maintenance or due to leakage of the refrigerant accumulating in the conditioned space. Standards have been developed to set maximum charge limits for flammable refrigerants in HVAC&R systems; however, existing safety standards and codes still restrict their use. The bodies that maintain and update these codes need publicly available, science-based information to enable credible guidelines for setting safe charge limits for different flammable refrigerants in different HVAC&R applications. In 2016, the Alliance for Responsible Atmospheric Policy, the Air-Conditioning Heating and Refrigeration Institute (AHRI), ASHRAE, the U.S. Department of Energy (DOE), and the State of California began efforts to develop such information. As part of this effort, Oak Ridge National Laboratory (ORNL) began the current, ongoing project to examine imposed charge limits for flammable refrigerants and identify reasonable adjustments to these limits when found appropriate. Past tasks under this project have included development of experimentally vetted, computational fluid dynamics (CFD) simulation approaches to study the results of leakage of flammable refrigerants from various HVAC&R systems into different types of commercial and residential spaces. In this report, we discuss recent efforts to develop a predictive model of the flammable volume fraction and accumulated refrigerant mass in a single-room residential space resulting from the leak of a flammable refrigerant from a small room air conditioning (RAC) unit. The eventual goal is development of a model suitable for public release which could simulate a range of scenarios. In discussions with the AHRTI Flammable Refrigerant Subcommittee (FRS) at the beginning of this effort, a total of 9 input parameters were chosen for consideration including room area, room/door opening area, ventilation fan flow rate, unit/leak height, leak area, leak rate, total refrigerant charge, refrigerant molecular weight, and state of the unit fan.

42 ENGINEERING↗

Understanding airflow pattern and temperature distribution in domestic refrigerators – A review analyzing recent developments and bridging knowledge gaps

Refrigerators have become an essential appliance in every household, and they consume approximately 30% of total electricity among other domestic appliances such as clothes washers, dryers, and air conditioners. With the refrigerator’s comparatively high energy consumption compared with other appliances, existing research has mainly focused on improving the energy efficiency of refrigerators by changing the design of the compressor, heat exchanger, refrigerant, and insulation. However, previous studies have paid very little attention to the research and development of the temperature distribution in the refrigerator, which is a key parameter in determining energy consumption and food safety. Therefore, this review aims to present an overview of recent design developments to improve the temperature distribution and air circulation in domestic refrigerators, including static refrigerators and no-frost refrigerators. Herein, this review article discusses the various operation and design factors that can affect the air circulation and temperature uniformity of the refrigerator, including shelf arrangement, the compressor on/off cycle, thermostat settings, evaporator design, ambient conditions, door opening frequency, and product loading temperatures. Additionally, this review provides a summary of the advanced vapor compression cycle based refrigerators that are expected to provide better energy efficiency and independent temperature control in freezer and refrigerator compartments. This review elaborates on the significance of improving the performance of the domestic refrigerator in terms of temperature distribution and air circulation.

42 ENGINEERING↗

Reduced Order Model to Predict Dispersion of Flammable Refrigerant into a Space

As the HVAC&R industry mobilizes to deploy more low-GWP refrigerants, relevant standards are being continually reviewed and updated. Those include the general safety standards ISO 5149 and ASHRAE 15, and the equipment standards IEC and UL. The standards systematically set the allowable maximum amount of refrigerant that should be used in different equipment types and different applications. To do so, they rely on predictions of how a leaked refrigerant mass will disperse into a space. Dispersion characteristics, such as total flammable volume and its residence time, determine the risk associated with the presence of the flammable refrigerant. The standards have included provisions for the use of flammable refrigerants for approximately two decades. They relied on limited analytical analyses and test cases in their development. Dispersion of a refrigerant into a space is complex. Computational fluid dynamics (CFD) are the most accurate in predicting a given problem. However, CFD is computationally expensive and requires specialized expertise and resources and is not suitable for use by standards development working group as prediction tool. This paper presents the development of a reduced order model (ROM) that predicts the key dispersion characteristics relevant to the dispersion of a leaked refrigerant into a space for any combination of input variables. The inputs are the refrigerant release height, the total released refrigerant mass and its release flow rate, the refrigerant molecular weight, the ventilation flow rate, the floor area and height of the space, recirculation air flow rate, and the tightness of the space. The outputs are histograms of volume fraction of the room in prescribed concentration bins and the total mass of the refrigerant in each bin normalized by the total refrigerant charge at 13 prescribed simulation time stamps between 1 and 900 seconds. The ROM is constructed from a set of CFD simulations with carefully chosen combinations of input parameters. The selection if done using a multidimensional sparse grid which is a generalization of the classical tensor approach but offers additional flexibility and thus can be more carefully tuned towards a specific model. The tuning is done to improve the accuracy, measured in the difference between the output values of the ROM and the CFD model, while minimizing the computational cost, measured in number of CFD simulations which is orders of magnitude more expensive than the processing the training data.

Edwards, Dean↗

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy performance augmentation of domestic refrigerators with microchannel condensers

Refrigerators are one of the most extensively used household appliances, accounting for approximately 4% of total household electricity consumption. Enhancing their energy performance can significantly reduce residential energy demand. As a result, this study focuses on reducing the energy consumption of a French-door, bottom-mount refrigerator using isobutane (R600a) as the working fluid. Here, the performance improvement of the refrigerators has been obtained mainly through improving the vapor compression refrigeration cycle, with a particular emphasis on condenser design. This study explores the impact of three-pass serpentine microchannel condenser on energy performance, along with the effects of two distinct fan combinations. Charge optimization experiments were conducted to identify the optimal refrigerant mass for the refrigerator unit with microchannel condenser. Additionally, a comprehensive numerical model was developed to analyze the behavior of vapor compression cycle under various refrigerant charges. The experimental findings revealed that the refrigerator unit with the three-pass microchannel condenser reduces the energy consumption of isobutane-based domestic refrigerators up to 16% while reducing the refrigerant charge by 11% in comparison to the refrigerator unit with conventional wire-and-tube condenser.

Charge optimization↗

Critical Literature Review of Low Global Warming Potential (GWP) Refrigerants and their Environmental Impact

Refrigeration and air conditioning currently account for ~20% of the total electricity consumption in buildings around the world. Over the next three decades as global temperatures are projected to increase, urbanization and economic growth will lead to an increased demand for refrigeration and cooling. Most commonly used refrigerants belong to the five following classes: (i) chlorofluorocarbons, (ii) hydrochlorofluorocarbons, (iii) hydrofluorocarbons (HFCs), (iv) hydrofluoroolefins (HFOs), and (v) natural refrigerants. Over the past century, there have been shifts in which compounds were used for refrigeration to improve safety and durability, allow for ozone protection, and, most recently, to reduce global warming potential (GWP). Although technological advances have led to increased cooling capacity and safer refrigerants, emissions from refrigeration systems can affect the environment by contributing to greenhouse gas emissions or by depleting the ozone layer, depending on the gas emitted. The focus is increasingly on adopting compounds that are both efficient at cooling and effective for reducing emissions and other adverse environmental impacts. Because of policy and regulatory changes to avert ozone depletion and global climate change, much discussion has centered on the environmental impacts of next-generation refrigerants. Of particular interest are the fluorinated refrigerants, HFCs and HFOs, most of which are defined as per- and polyfluoroalkyl substances (PFAS) and their breakdown products (especially trifluoroacetic acid). The US Environmental Protection Agency in 2021 drafted a Strategic Roadmap for PFAS, which has already resulted in an increase in investment in research on these compounds and has restricted the release of PFAS into the environment through the implementation of monitoring and reporting requirements. A critical evaluation of fluorinated refrigerants and their breakdown products with respect to persistence, biodegradation and toxicity, and global warming potential is needed to guide environmental regulations. This document aims to perform a critical review of the relevant scientific data on the most common refrigerants currently used, their degradation products, and their alternatives. Where available, estimates of precursor production quantities and existing environmental regulatory information are reviewed. Key data of interest for the evaluation include physicochemical properties, environmental fate parameters, ecological or human health toxicity/risk information, and GWP for compounds of interest.

54 ENVIRONMENTAL SCIENCES↗

Critical Literature Review of Low Global Warming Potential (GWP) Refrigerants and their Environmental Impact

Refrigeration and air conditioning currently account for ~20% of the total electricity consumption in buildings around the world. Over the next three decades as global temperatures are projected to increase, urbanization and economic growth will lead to an increased demand for refrigeration and cooling. Most commonly used refrigerants belong to the five following classes: (i) chlorofluorocarbons, (ii) hydrochlorofluorocarbons, (iii) hydrofluorocarbons (HFCs), (iv) hydrofluoroolefins (HFOs), and (v) natural refrigerants. Over the past century, there have been shifts in which compounds were used for refrigeration to improve safety and durability, allow for ozone protection, and, most recently, to reduce global warming potential (GWP). Although technological advances have led to increased cooling capacity and safer refrigerants, emissions from refrigeration systems can affect the environment by contributing to greenhouse gas emissions or by depleting the ozone layer, depending on the gas emitted. The focus is increasingly on adopting compounds that are both efficient at cooling and effective for reducing emissions and other adverse environmental impacts. Because of policy and regulatory changes to avert ozone depletion and global climate change, much discussion has centered on the environmental impacts of next-generation refrigerants. Of particular interest are the fluorinated refrigerants, HFCs and HFOs, most of which are defined as per- and polyfluoroalkyl substances (PFAS) and their breakdown products (especially trifluoroacetic acid). The US Environmental Protection Agency in 2021 drafted a Strategic Roadmap for PFAS, which has already resulted in an increase in investment in research on these compounds and has restricted the release of PFAS into the environment through the implementation of monitoring and reporting requirements. A critical evaluation of fluorinated refrigerants and their breakdown products with respect to persistence, biodegradation and toxicity, and global warming potential is needed to guide environmental regulations. This document aims to perform a critical review of the relevant scientific data on the most common refrigerants currently used, their degradation products, and their alternatives. Where available, estimates of precursor production quantities and existing environmental regulatory information are reviewed. Key data of interest for the evaluation include physicochemical properties, environmental fate parameters, ecological or human health toxicity/risk information, and GWP for compounds of interest.

54 ENVIRONMENTAL SCIENCES↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Mitigation of safety and environmental challenges posed by refrigerants

The abatement of safety and environmental burden associated with low and ultra-low Global Warming Potential (GWP) refrigerants is a critical undertaking. As the industry shifts towards more environmentally friendly alternatives, mitigating the potential risks and ensuring safety standards becomes paramount. The adoption of mildly and highly flammable refrigerants contributes significantly to minimizing the greenhouse gas impact on the environment, aligning with global climate and sustainability goals. However, it is essential to address safety concerns and potential environmental implications associated with the end use of these refrigerants. A method to mitigate the safety risk in a flammable refrigerant based heating, ventilation, air-conditioning, and refrigeration (HVACR) system is the primary focus of this paper. Advent of A2L and A3 refrigerants as replacements to high GWP refrigerants requires careful handling of leak episodes to lower or eliminate the risk associated with creating flammable mixtures capable of fire/explosion hazard. Solid materials tailored to target the molecule of interest (i.e., refrigerant.) by engineering the microporous structure as well as chemically functionalizing the surface to attract and hold on to the chemical compound being removed from the gas stream was realized. Quantitative analysis reveals the adsorbent's effectiveness in reducing leak potential in the range of 40 %–100 % for various refrigerants. Strategic placement and active leak management with negative pressure offer promising avenues for capturing leaked refrigerants, enhancing overall safety.

42 ENGINEERING↗

Connected Loads – Grid Connected Appliances: Commercial Refrigeration System Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 (or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetic refrigeration for maser amplifier cooling

The development of a multifrequency upconverter-maser system for the DSN has created the need to develop a closed-cycle refrigerator (CCR) capable of providing more than 3 watts of refrigeration capability at 4.5 K. In addition, operating concerns such as the high cost of electrical power consumption and the loss of maser operation due to CCR failures require that improvements be made to increase the efficiency and reliability of the CCR. One refrigeration method considered is the replacement of the Joule-Thomson expansion circuit with a magnetic refrigeration. Magnetic refrigerators can provide potentially reliable and highly efficient refrigeration at a variety of temperature ranges and cooling power. The concept of magnetic refrigeration is summarized and a literature review of existing magnetic refrigerator designs which have been built and tested and that may also be considered as possibilities as a 4 K to 15 K magnetic refrigeration stage for the DSN closed-cycle refrigerator is provided.

Johnson, D. L.↗