Search NASA⌕ Search

SEARCH · Search NASA

Results for “regularization by denoising”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Rapid Optimization of Total Variation with Applications in Imaging, Additive Manufacturing, and Qualification

Total Variation optimization penalizes the gradient of a control variable or state. While this work focuses on image processing in particular, it has also found applications in inverse problems and topology optimization. In image processing, the goal is to maintain faithfulness to the original image while denoising and/or deblurring. Additionally, bilevel optimization over the spatially varying regularization weights can illuminate interfaces such as damage regions and other anomalies. We will address two fundamental challenges with TV-optimization: (i) the typical slow convergence of existing TV-optimization methods, and (ii) the selection of spatially varying TV parameters to promote interface detection. Additionally, we will apply such techniques to image data collected in additive manufacturing. In said context, stochasticity in build events induces flaws in the manufactured piece, compromising the integrity of said part. There is a critical need for in-situ monitoring to spot anomalies once they form, and in this setting we apply our total variation and hyperparameter solvers. We will develop a customized algorithm based on for extreme-scale TV-optimization that achieves super-linear or quadratic-convergence, a critical property for real-time, image-by-image analysis. A worst-case outcome is a preprocessing step that enhances image quality in-situ, specifically for out-of-focus and noisy images.

36 MATERIALS SCIENCE↗

Multitaper Spectral Analysis and Wavelet Denoising Applied to Helioseismic Data

Estimates of solar normal mode frequencies from helioseismic observations can be improved by using Multitaper Spectral Analysis (MTSA) to estimate spectra from the time series, then using wavelet denoising of the log spectra. MTSA leads to a power spectrum estimate with reduced variance and better leakage properties than the conventional periodogram. Under the assumption of stationarity and mild regularity conditions, the log multitaper spectrum has a statistical distribution that is approximately Gaussian, so wavelet denoising is asymptotically an optimal method to reduce the noise in the estimated spectra. We find that a single m-upsilon spectrum benefits greatly from MTSA followed by wavelet denoising, and that wavelet denoising by itself can be used to improve m-averaged spectra. We compare estimates using two different 5-taper estimates (Stepian and sine tapers) and the periodogram estimate, for GONG time series at selected angular degrees l. We compare those three spectra with and without wavelet-denoising, both visually, and in terms of the mode parameters estimated from the pre-processed spectra using the GONG peak-fitting algorithm. The two multitaper estimates give equivalent results. The number of modes fitted well by the GONG algorithm is 20% to 60% larger (depending on l and the temporal frequency) when applied to the multitaper estimates than when applied to the periodogram. The estimated mode parameters (frequency, amplitude and width) are comparable for the three power spectrum estimates, except for modes with very small mode widths (a few frequency bins), where the multitaper spectra broadened the modest compared with the periodogram. We tested the influence of the number of tapers used and found that narrow modes at low n values are broadened to the extent that they can no longer be fit if the number of tapers is too large. For helioseismic time series of this length and temporal resolution, the optimal number of tapers is less than 10.

Komm, R. W.↗

A generalized vector-valued total variation algorithm

We propose a simple but flexible method for solving the generalized vector-valued TV (VTV) functional, which includes both the {ell}{sup 2}-VTV and {ell}{sup 1}-VTV regularizations as special cases, to address the problems of deconvolution and denoising of vector-valued (e.g. color) images with Gaussian or salt-andpepper noise. This algorithm is the vectorial extension of the Iteratively Reweighted Norm (IRN) algorithm [I] originally developed for scalar (grayscale) images. This method offers competitive computational performance for denoising and deconvolving vector-valued images corrupted with Gaussian ({ell}{sup 2}-VTV case) and salt-and-pepper noise ({ell}{sup 1}-VTV case).

99 GENERAL AND MISCELLANEOUS↗

On convergent finite difference schemes for variational–PDE-based image processing

We study an adaptive anisotropic Huber functional-based image restoration scheme. Using a combination of L2–L1 regularization functions, an adaptive Huber functional-based energy minimization model provides denoising with edge preservation in noisy digital images. We study a convergent finite difference scheme based on continuous piecewise linear functions and use a variable splitting scheme, namely the Split Bregman (In: Goldstein and Osher, SIAM J Imaging Sci 2(2):323–343, 2009) algorithm, to obtain the discrete minimizer. Experimental results are given in image denoising and comparison with additive operator splitting, dual fixed point, and projected gradient schemes illustrates that the best convergence rates are obtained for our algorithm.

97 MATHEMATICS AND COMPUTING↗

A proximal trust-region method for nonsmooth optimization with inexact function and gradient evaluations

Many applications require minimizing the sum of smooth and nonsmooth functions. For example, basis pursuit denoising problems in data science require minimizing a measure of data misfit plus an $\ell^1$-regularizer. Similar problems arise in the optimal control of partial differential equations (PDEs) when sparsity of the control is desired. Here, we develop a novel trust-region method to minimize the sum of a smooth nonconvex function and a nonsmooth convex function. Our method is unique in that it permits and systematically controls the use of inexact objective function and derivative evaluations. When using a quadratic Taylor model for the trust-region subproblem, our algorithm is an inexact, matrix-free proximal Newton-type method that permits indefinite Hessians. We prove global convergence of our method in Hilbert space and demonstrate its efficacy on three examples from data science and PDE-constrained optimization.

97 MATHEMATICS AND COMPUTING↗

Cerebral perfusion computed tomography deconvolution via structure tensor total variation regularization

Purpose: Cerebral perfusion computed tomography (PCT) imaging as an accurate and fast acute ischemic stroke examination has been widely used in clinic. Meanwhile, a major drawback of PCT imaging is the high radiation dose due to its dynamic scan protocol. The purpose of this work is to develop a robust perfusion deconvolution approach via structure tensor total variation (STV) regularization (PD-STV) for estimating an accurate residue function in PCT imaging with the low-milliampere-seconds (low-mAs) data acquisition. Methods: Besides modeling the spatio-temporal structure information of PCT data, the STV regularization of the present PD-STV approach can utilize the higher order derivatives of the residue function to enhance denoising performance. To minimize the objective function, the authors propose an effective iterative algorithm with a shrinkage/thresholding scheme. A simulation study on a digital brain perfusion phantom and a clinical study on an old infarction patient were conducted to validate and evaluate the performance of the present PD-STV approach. Results: In the digital phantom study, visual inspection and quantitative metrics (i.e., the normalized mean square error, the peak signal-to-noise ratio, and the universal quality index) assessments demonstrated that the PD-STV approach outperformed other existing approaches in terms of the performance of noise-induced artifacts reduction and accurate perfusion hemodynamic maps (PHM) estimation. In the patient data study, the present PD-STV approach could yield accurate PHM estimation with several noticeable gains over other existing approaches in terms of visual inspection and correlation analysis. Conclusions: This study demonstrated the feasibility and efficacy of the present PD-STV approach in utilizing STV regularization to improve the accuracy of residue function estimation of cerebral PCT imaging in the case of low-mAs.

60 APPLIED LIFE SCIENCES↗

RapidEELS: machine learning for denoising and classification in rapid acquisition electron energy loss spectroscopy

Recent advances in detectors for imaging and spectroscopy have afforded in situ, rapid acquisition of hyperspectral data. While electron energy loss spectroscopy (EELS) data acquisition speeds with electron counting are regularly reaching 400 frames per second with near-zero read noise, signal to noise ratio (SNR) remains a challenge owing to fundamental counting statistics. In order to advance understanding of transient materials phenomena during rapid acquisition EELS, trustworthy analysis of noisy spectra must be demonstrated. In this study, we applied machine learning techniques to denoise high frame rate spectra, benchmarking with slower frame rate “ground truths”. The results provide a foundation for reliable use of low SNR data acquired in rapid, in-situ spectroscopy experiments. Such a tool-set is a first step toward both automation in microscopy as well as use of these methods to interrogate otherwise poorly understood transformations.

36 MATERIALS SCIENCE↗

MO-DE-207A-02: A Feature-Preserving Image Reconstruction Method for Improved Pancreaticlesion Classification in Diagnostic CT Imaging

Purpose: To develop a feature-preserving model based image reconstruction (MBIR) method that improves performance in pancreatic lesion classification at equal or reduced radiation dose. Methods: A set of pancreatic lesion models was created with both benign and premalignant lesion types. These two classes of lesions are distinguished by their fine internal structures; their delineation is therefore crucial to the task of pancreatic lesion classification. To reduce image noise while preserving the features of the lesions, we developed a MBIR method with curvature-based regularization. The novel regularization encourages formation of smooth surfaces that model both the exterior shape and the internal features of pancreatic lesions. Given that the curvature depends on the unknown image, image reconstruction or denoising becomes a non-convex optimization problem; to address this issue an iterative-reweighting scheme was used to calculate and update the curvature using the image from the previous iteration. Evaluation was carried out with insertion of the lesion models into the pancreas of a patient CT image. Results: Visual inspection was used to compare conventional TV regularization with our curvature-based regularization. Several penalty-strengths were considered for TV regularization, all of which resulted in erasing portions of the septation (thin partition) in a premalignant lesion. At matched noise variance (50% noise reduction in the patient stomach region), the connectivity of the septation was well preserved using the proposed curvature-based method. Conclusion: The curvature-based regularization is able to reduce image noise while simultaneously preserving the lesion features. This method could potentially improve task performance for pancreatic lesion classification at equal or reduced radiation dose. The result is of high significance for longitudinal surveillance studies of patients with pancreatic cysts, which may develop into pancreatic cancer. The Senior Author receives financial support from Siemens GmbH Healthcare.

60 APPLIED LIFE SCIENCES↗

Plug-and-Play Priors for Bright Field Electron Tomography and Sparse Interpolation

Many material and biological samples in scientific imaging are characterized by nonlocal repeating structures. These are studied using scanning electron microscopy and electron tomography. Sparse sampling of individual pixels in a two-dimensional image acquisition geometry, or sparse sampling of projection images with large tilt increments in a tomography experiment, can enable high speed data acquisition and minimize sample damage caused by the electron beam. In this paper, we present an algorithm for electron tomographic reconstruction and sparse image interpolation that exploits the nonlocal redundancy in images. We adapt a framework, termed plug-and-play priors, to solve these imaging problems in a regularized inversion setting. The power of the plug-and-play approach is that it allows a wide array of modern denoising algorithms to be used as a “prior model” for tomography and image interpolation. We also present sufficient mathematical conditions that ensure convergence of the plug-and-play approach, and we use these insights to design a new nonlocal means denoising algorithm. Finally, we demonstrate that the algorithm produces higher quality reconstructions on both simulated and real electron microscope data, along with improved convergence properties compared to other methods.

47 OTHER INSTRUMENTATION↗

A mixed $\ell_1$ regularization approach for sparse simultaneous approximation of parameterized PDEs

We introduce and assess a novel sparse polynomial technique for the simultaneous approximation of parameterized partial differential equations (PDEs) with deterministic and stochastic inputs. Our approach treats the numerical solution as a jointly sparse reconstruction problem through the reformulation of the standard basis pursuit denoising, where the set of jointly sparse vectors is infinite. To achieve global reconstruction of sparse solutions to parameterized elliptic PDEs over both physical and parametric domains, we combine the standard measurement scheme developed for compressed sensing in the context of bounded orthonormal systems with a novel mixed-norm based $\ell_1$ regularization method that exploits both energy and sparsity. Moreover, we are able to prove that, with minimal sample complexity, error estimates comparable to the best $s$-term and quasi-optimal approximations are achievable, while requiring only {\em a priori} bounds on polynomial truncation error with respect to the energy norm.Finally, we perform extensive numerical experiments on several high-dimensional parameterized elliptic PDE models to demonstrate the superior recovery properties of the proposed approach.

97 MATHEMATICS AND COMPUTING↗

Deep learning-based noise filtering toward millisecond order imaging by using scanning transmission electron microscopy

Application of scanning transmission electron microscopy (STEM) to in situ observation will be essential in the current and emerging data-driven materials science by taking STEM’s high affinity with various analytical options into account. As is well known, STEM’s image acquisition time needs to be further shortened to capture a targeted phenomenon in real-time as STEM’s current temporal resolution is far below the conventional TEM’s. However, rapid image acquisition in the millisecond per frame or faster generally causes image distortion, poor electron signals, and unidirectional blurring, which are obstacles for realizing video-rate STEM observation. Here we show an image correction framework integrating deep learning (DL)-based denoising and image distortion correction schemes optimized for STEM rapid image acquisition. By comparing a series of distortion corrected rapid scan images with corresponding regular scan speed images, the trained DL network is shown to remove not only the statistical noise but also the unidirectional blurring. This result demonstrates that rapid as well as high-quality image acquisition by STEM without hardware modification can be established by the DL. The DL-based noise filter could be applied to in-situ observation, such as dislocation activities under external stimuli, with high spatio-temporal resolution.

47 OTHER INSTRUMENTATION↗

Denoised Wigner distribution deconvolution via low-rank matrix completion

Wigner distribution deconvolution (WDD) is a decades-old method for recovering phase from intensity measurements. Although the technique offers an elegant linear solution to the quadratic phase retrieval problem, it has seen limited adoption due to its high computational/memory requirements and the fact that the technique often exhibits high noise sensitivity. Here, we propose a method for noise suppression in WDD via low-rank noisy matrix completion. Our technique exploits the redundancy of an object’s phase space to denoise its WDD reconstruction. We show in model calculations that our technique outperforms other WDD algorithms as well as modern iterative methods for phase retrieval such as ptychography. Here, our results suggest that a class of phase retrieval techniques relying on regularized direct inversion of ptychographic datasets (instead of iterative reconstruction techniques) can provide accurate quantitative phase information in the presence of high levels of noise.

47 OTHER INSTRUMENTATION↗

SU-F-18C-13: Low-Dose X-Ray CT Reconstruction Using a Hybrid First-Order Method

Purpose: To develop a novel reconstruction method for X-ray CT that can lead to accurate reconstruction at significantly reduced dose levels combining low X-ray incident intensity and few views of projection data. Methods: The noise nature of the projection data at low X-ray incident intensity was modeled and accounted by the weighted least-squares (WLS) criterion. The total variation (TV) penalty was used to mitigate artifacts caused by few views of data. The first order primal-dual (FOPD) algorithm was used to minimize TV in image domain, which avoided the difficulty of the non-smooth objective function. The TV penalized WLS reconstruction was achieved by alternated FOPD TV minimization and projection onto convex sets (POCS) for data fidelity constraints. The proposed FOPD-POCS method was evaluated using the FORBILD jaw phantom and the real cadaver head CT data. Results: The quantitative measures, root mean square error (RMSE) and contrast-to-noise ratio (CNR), demonstrate the superior denoising capability of WLS over LS-based TV iterative reconstruction. The improvement of RMSE (WLS vs. LS) is 15%∼21% and that of CNR is 17%∼72% when the incident counts per ray are ranged from 1×10{sup 5} to 1×10{sup 3}. In addition, the TV regularization can accurately reconstruct images from about 50 views of the jaw phantom. The FOPD-POCS reconstruction reveals more structural details and suffers fewer artifacts in both the phantom and real head images. The FOPD-POCS method also shows fast convergence at low X-ray incident intensity. Conclusion: The new hybrid FOPD-POCS method, based on TV penalized WLS, yields excellent image quality when the incident X-ray intensity is low and the projection views are limited. The reconstruction is computationally efficient since the FOPD minimization of TV is applied only in the image domain. The characteristics of FOPD-POCS can be exploited to significantly reduce radiation dose of X-ray CT without compromising accuracy for diagnosis or treatment planning.

60 APPLIED LIFE SCIENCES↗

Denoising diffusion models with geometry adaptation for high fidelity calorimeter simulation

Simulation is crucial for all aspects of collider data analysis, but the available computing budget in the High Luminosity LHC era will be severely constrained. Generative machine learning models may act as surrogates to replace physics-based full simulation of particle detectors, and diffusion models have recently emerged as the state of the art for other generative tasks. Here, we introduce CaloDiffusion, a denoising diffusion model trained on the public CaloChallenge datasets to generate calorimeter showers. Our algorithm employs 3D cylindrical convolutions, which take advantage of symmetries of the underlying data representation. To handle irregular detector geometries, we augment the diffusion model with a new geometry latent mapping (GLaM) layer to learn forward and reverse transformations to a regular geometry that is suitable for cylindrical convolutions. The showers generated by our approach are nearly indistinguishable from the full simulation, as measured by several different metrics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total Variation Majorization Minimization (TV-MM) Approach to Radiometer Brightness Temperature Gridding and Reconstruction

This paper presents the implementation of an algorithm to enhance the image resolution of the Earth's surface brightness temperature (T B ) data measured by radiometers such as the one onboard of the Soil Moisture Active Passive (SMAP) mission. A key step in radiometer T B processing is the conversion of the swath-based calibrated antenna temperature (T A ) measurements to the Level 3 Earth-centered grid. The simplest algorithm to transform this data from swath to gridded format is called drop-in-the-bucket which simply averages surrounding noisy T A samples to form a T B value at the gridded location. This method reduces noise, however produces low resolution products. To obtain a higher resolution product, SMAP uses other techniques such the Backus-Gilbert (BG) algorithm, which is the conventional method used in microwave radiometry. Although this method performs the required interpolation, it is not effective in denoising and removing blurring effects due to antenna filtering of the radiometer image data. Our motivation for this development is to further improve the resolution through post-processing of the radiometer T B image, a highly cost-effective method of image enhancement. The approach adapted in this work is based on the minimization of the Total Variation (TV) regularized objective function that is used extensively in solving general ill-posed linear inverse problems in image processing. Since the TV-based objective function is convex but not everywhere differentiable, there exists many numerical algorithms that can estimate the solution and the one selected for this work is called Majorization- Minimization (MM). By applying this algorithm, simulation experiments were performed based on synthetic data from the Geophysical model as well as real SMAP data to demonstrate the effectiveness of the technique. Results were then compared against the BG method.

Wing Lee↗

TH-A-18C-07: Noise Suppression in Material Decomposition for Dual-Energy CT

Purpose: A general problem of dual-energy CT (DECT) is that the decomposition is sensitive to noise in the two sets of dual-energy projection data, resulting in severely degraded qualities of decomposed images. We have previously proposed an iterative denoising method for DECT. Using a linear decomposition function, the method does not gain the full benefits of DECT on beam-hardening correction. In this work, we expand the framework of our iterative method to include non-linear decomposition models for noise suppression in DECT. Methods: We first obtain decomposed projections, which are free of beam-hardening artifacts, using a lookup table pre-measured on a calibration phantom. First-pass material images with high noise are reconstructed from the decomposed projections using standard filter-backprojection reconstruction. Noise on the decomposed images is then suppressed by an iterative method, which is formulated in the form of least-square estimation with smoothness regularization. Based on the design principles of a best linear unbiased estimator, we include the inverse of the estimated variance-covariance matrix of the decomposed images as the penalty weight in the least-square term. Analytical formulae are derived to compute the variance-covariance matrix from the measured decomposition lookup table. Results: We have evaluated the proposed method via phantom studies. Using non-linear decomposition, our method effectively suppresses the streaking artifacts of beam-hardening and obtains more uniform images than our previous approach based on a linear model. The proposed method reduces the average noise standard deviation of two basis materials by one order of magnitude without sacrificing the spatial resolution. Conclusion: We propose a general framework of iterative denoising for material decomposition of DECT. Preliminary phantom studies have shown the proposed method improves the image uniformity and reduces noise level without resolution loss. In the future, we will perform more phantom studies to further validate the performance of the purposed method. This work is supported by a Varian MRA grant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One-dimensional phase retrieval: Regularization, box relaxation and uniqueness

Recovering a signal from its Fourier magnitude is referred to as phase retrieval, which occurs in different fields of engineering and applied physics. This paper gives a new characterization of the phase retrieval problem. Particularly useful is the analysis revealing that the common gradient-based regularization does not restrict the set of solutions to a smaller set. Specifically focusing on binary signals, we show that a box relaxation is equivalent to the binary constraint for Fourier-types of phase retrieval. Here, we further prove that binary signals can be recovered uniquely up to trivial ambiguities under certain conditions. Finally, we use the characterization theorem to develop an efficient denoising algorithm.

97 MATHEMATICS AND COMPUTING↗

Enhanced detection of paramagnetic fluorine-19 magnetic resonance imaging agents using zero echo time sequence and compressed sensing

Fluorine-19 ( 19 F) magnetic resonance imaging (MRI) is an emerging technique offering specific detection of labeled cells in vivo. Lengthy acquisition times and modest signal-to-noise ratio (SNR) makes three-dimensional spin-density–weighted 19 F imaging challenging. Recent advances in tracer paramagnetic metallo-perfluorocarbon (MPFC) nanoemulsion probes have shown multifold SNR improvements due to an accelerated 19 F T 1 relaxation rate and a commensurate gain in imaging speed and averages. However, 19 F T 2 -reduction and increased linewidth limit the amount of metal additive in MPFC probes, thus constraining the ultimate SNR. To overcome these barriers, we describe a compressed sampling (CS) scheme, implemented using a “zero” echo time (ZTE) sequence, with data reconstructed via a sparsity-promoting algorithm. Our CS-ZTE scheme acquires k-space data using an undersampled spherical radial pattern and signal averaging. Image reconstruction employs off-the-shelf sparse solvers to solve a joint total variation and -norm regularized least square problem. To evaluate CS-ZTE, we performed simulations and acquired 19 F MRI data at 11.7 T in phantoms and mice receiving MPFC-labeled dendritic cells. For MPFC-labeled cells in vivo, we show SNR gains of ~6.3 × with 8-fold undersampling. We show that this enhancement is due to three mechanisms including undersampling and commensurate increase in signal averaging in a fixed scan time, denoising attributes from the CS algorithm, and paramagnetic reduction of T 1 . Importantly, 19 F image intensity analyses yield accurate estimates of absolute quantification of 19 F spins. Overall, the CS-ZTE method using MPFC probes achieves ultrafast imaging, a substantial boost in detection sensitivity, accurate 19 F spin quantification, and minimal image artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗