Search NASA⌕ Search

SEARCH · Search NASA

Results for “requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Estimating the Contributions to Human Error Probability from the Convolution of the Distribution of Time Available and Time Required

As part of their duties, Human Reliability Analysis must often evaluate if crews in nuclear power plants (NPPs) can complete tasks associated with a human-failure event within time limits. For example, the time required in NPP scenarios is determined by systematic and structured walkthroughs, feasibility studies, recorded times from training exercises, and interviews with experienced operators and experts. Typically, a point estimate is derived for the estimate (mean, maximum, or 95th percentile of time required). Using point-estimate values can mask the risk associated with variability among crews, plant conditions and set-up, environmental conditions, and other impact factors under which these actions are executed. While point estimates for time required and time available have served the industry well, without considering the uncertainty they could lead to biased understanding about the risk. The Integrated Human Event Analysis System - General Methodology (IDHEAS-G) model (developed by the US Nuclear Regulatory Commission, NRC) for human error probability calculates human error probability by summing two probabilities: insufficient time and cognitive error. As such, the model takes a more holistic approach by considering the full distributions for time required and time available to calculate the human error probability because the time available to complete the task is insufficient. In this study, we expand on the work of the NRC and discuss methods for estimating these time considerations. For example, for the time required, the impact of Performance Influencing Factors (PIFs) on the distribution was divided into impacts that are aleatory in nature, such as crew-to-crew variability, and those that are epistemic (i.e., the PIFs). Starting with the factors that introduce aleatory uncertainty, a first-order distribution was developed from a large set of time required (i.e., NPP task completion times) data for the range of operator actions that occur in the NPP control room under simulated accident conditions. The first-order distribution can then be adjusted to account for epistemic uncertainty using research associated with the impact of applicable PIFs on the time required. We also develop guidance for analysts to address the probability distributions for the time available. The guidance we developed on how to estimate time required and time available distributions is based on the identification of pertinent research and data, data analyses, and expert knowledge elicitation.

human error probability, human performance, time e↗

Clause-by-Clause Summary of Requirements in IEEE Standard 1547-2018

The revised IEEE 1547 standard (IEEE Std 1547-2018) contains eleven chapters (clauses) and eight annexes that comprise 136 pages. Each clause specifies information or requirements that apply to certain aspects important to the interconnection of distributed energy resources to the electric power system. Implementation of the requirements needs a careful study of the underlying technical concept and also needs the appropriate information that may be required to calculate various settings and configurations. This document aims to provide an introductory text to assist users of IEEE Std 1547-2018 in identifying the following questions: what is the primary audience of the clause/subclause? What knowledge is required to understand the technical subject matter? What information is required to apply/implement the requirements specified? What level of fluency with the subject matter is required to apply/implement the requirements?

24 POWER TRANSMISSION AND DISTRIBUTION↗

Requirements for Cataloging Hanford Geophysical Datasets

Environmental management activities at the Hanford Site produce extensive data about site conditions, contaminants, cleanup, and more. Managing and archiving that data requires a high degree of collaboration among site contractors and a high level of awareness by project managers and staff. Part of that effort is developing a Hanford Environmental Information and Data Index (HEIDI) to organize the data and maximize its value by making it findable and available for reuse. The objective is to catalog the disparate data sets collected to address the evolving needs of planning, executing, and documenting cleanup over several decades up to the present day, including links to active data sources when available. A properly implemented data catalog makes finding environmental datasets related to an area or theme a routine, reliable process, without requiring the searcher to have special knowledge that a data set exists and where it may be stored. In this project, a working group, including the U.S. Department of Energy, the Hanford Site contractors, and Pacific Northwest National Laboratory staff, identified needs and requirements for handling complex site data. Geophysical data was chosen as a test case because it can be large and complex and often involves multiple processing steps to extract the information incorporated into deliverables. The ability to document those steps was one of the requirements identified for the catalog. In addition to developing requirements, other activities included selecting a metadata schema and initial testing with the objective of determining whether the workflow and capabilities of selected data catalog software platforms were sufficient to implement and impose the identified requirements. This initial testing involved running the default catalog instance using the software platform of interest and altering the configuration to achieve each requirement, if possible. Where configuration alone was insufficient, the possibility of modifying the software by changing the code was examined, but not implemented. A follow-on task is planned to reprogram the code as necessary to implement requirements in a prototype catalog.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Designing Energy-Efficient Quantum Computers Through Prediction and Reduction of Cooling Requirements for Cryogenic Electronics

Quantum computing has been identified as a “wild card” by the International Energy Agency in predicting future global data center energy usage. This is primarily because both uncertainty in the extent to which quantum computing will be adopted, and uncertainty in the power consumption of individual quantum data centers. Unlike the classical counterparts, quantum computers need to be maintained at near absolute zero, requiring energy-intensive cryogenic cooling systems. Therefore, as quantum computers scale up from existing 50 qubit technology demonstrations to the 10,000 to 100,000 qubit systems that will be able to solve complex problems, the energy consumption of both the electronics and the required cooling systems will also increase. To predict this scaling, this work analyzes the energy requirements for both computation and cooling of quantum hardware. We show that the energy requirements for cooling of quantum computers is determined by several computing system parameters, including the number and type of physical qubits, the operating temperature, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. The energy requirements can then be found based on thermal system parameters such as cooling efficiency and cryostat heat transfer. Analysis of these parameters shows that the energy required for cooling is significantly larger than that required for computation, a reversal from energy usage patterns seen in conventional computing. The results and discussions provide a road-map for creating energy efficient quantum computers through the selection of computer architectures and cryogenic system configurations that minimize cooling requirements.

energy efficiency↗

Enabling Marine Energy Integration for Ocean Observing: Functional Requirements

Marine renewable energy (i.e., wave, tidal or ocean current, thermal gradient, and salinity gradient) or MRE can revolutionize ocean observing capabilities. Five use cases representing a range of ocean observing platforms were developed based on end-user feedback. Drawing from these use cases, common needs or functional requirements were developed to help guide the integration of MRE power delivery for ocean observation structures and functions. The functional requirements were determined from descriptions of the use cases, specifications of hardware that are used or closely associated with existing ocean observation platforms, and direct feedback from ocean observation sensor/platform developers and users. Twenty types of functional requirements were identified, including those associated with power and energy use; physical system requirements; temperature and depth; electrical, acoustic, and motion interference; and reliability. Each set of functional requirements is illustrated as features of the use cases. By defining functional requirements for MRE technology integration in ocean observing platforms, and focusing on end-user requirements, barriers to developing MRE-driven ocean observation missions can be reduced.

50 EE - Wind and Water Power Program - Water (EE-4↗

Hydropower flexibility valuation tool for flow requirement evaluation

Timing of generation is becoming more and more valuable. This creates greater potential tension between environmental and power system objectives since both systems require their own flow patterns. Identifying win–win outcomes in this context requires being able to discuss the value of flexibility across stakeholder groups. This research proposes a two-stage optimization method to understand hydropower flexibility to meet both environmental and power system requirements. The tool simulates the two-settlement market process in the U.S. by maximizing revenues from both the day-ahead and real-time markets, subject to plant operational limits, regulatory flow and ramping requirements, and uncertainties associated with water availability and market prices. The model is formulated as linear programming problems and solved using IBM ILOG CPLEX optimizer. By examining a range of flow requirements, ramping constraints, and storage capacities, the proposed tool shows how to make more informed decisions to weigh the cost of specific flow requirements in the context of the overall license requirements. Results from the case study show that revenue is more sensitive to the ramping constraints than the minimum flow constraints. We also demonstrate that removing flow constraints in a dry month increases monthly revenue by up to 118%, as opposed to only 1% in a wet month. In addition, our results suggest that using a learning-based water flow forecast results in an increase of monthly revenue up to 6.4% compared with persistence forecast.

13 HYDRO ENERGY↗

Requirements on the gain calibration for LiteBIRD polarisation data with blind component separation

The detection of primordial B modes of the cosmic microwave background (CMB) could provide information about the early stages of the Universe's evolution. The faintness of this signal requires exquisite calibration accuracy and control of instrumental systematic effects which otherwise could bias the measurements. In this work, we study the impact of an imperfect relative polarisation gain calibration on the recovered value of the tensor-to-scalar ratio r for the LiteBIRD experiment, through the application of the blind Needlet Internal Linear Combination (NILC) foreground-cleaning method. We derive requirements on the relative calibration accuracy of the overall polarisation gain (Δg ν ) for each LiteBIRD frequency channel. Our results show that minimum variance techniques, as NILC, are less sensitive to systematic gain calibration uncertainties compared to a parametric approach, if the latter is not equipped with a proper modelling of these instrumental effects. In this study, the most stringent requirements are found in the channels where the CMB signal is relatively brighter, with the tightest constraints at 166 GHz (Δg ν ≈ 0.16%). This differs from the outcome of an analogous analysis performed with a parametric method, where the tightest requirements are obtained for the foreground-dominated channels. Gain calibration uncertainties, corresponding to the derived requirements, are then simultaneously propagated into all frequency channels. By doing so, we find that the overall impact on estimated r is lower than the total gain systematic budget for LiteBIRD approximately by a factor 5, due to the correlations of the impacts of gain calibration uncertainties in different frequency channels. In order to decouple the systematic effect from the specific choice of the model, we derive the requirements assuming constant spectral parameters for the foreground emission. To assess the robustness of the obtained results against more realistic scenarios, we repeat the analysis assuming sky models of intermediate and high complexity. In these further cases, we adopt an optimised NILC pipeline, called the Multi-Clustering NILC (MC-NILC). We find that the impact of gain calibration uncertainties on r is lower than the LiteBIRD gain systematics budget for the intermediate-complexity sky model. For the high-complexity case, instead, it would be necessary to tighten the requirements by a factor 1.8.

79 ASTRONOMY AND ASTROPHYSICS↗

Requirements and Conceptual Design of Off-gas Systems for the Reprocessing of Metallic Fuels

An assessment has been conducted to determine how key regulations regarding volatile radionuclide emissions to the atmosphere may apply to the off-gas streams associated with electrochemical reprocessing. The scope of this assessment was based upon a generic electrochemical reprocessing scheme with a throughput rate of 200 MTIHM/y applied to metallic fuel discharged from a sodium fast reactor (SFR), but the findings are able to be translated to other advanced nuclear scenarios as merited. Air dispersion modeling was performed using the EPA CAP-88 model and evaluated the uncontrolled decontamination factors (DFs) that would be required to achieve regulatory compliance with the dose-based limits set forth by EPA regulation 40 CFR 190.10(a). These DFs were compared to those required by fuel cycle–based limits set forth by EPA regulation 40 CFR 190.10(b). Two theoretical sites with disparate climatological conditions were selected for air dispersion modeling (Idaho and Tennessee). The radionuclides modeled included 3 H, 85 Kr, 129 I, and selected alpha-emitting transuranic isotopes (referred to here as 239 Pu-TRU <1y ). It was found that the fuel cycle-based limits in 40 CFR 190.10(b) are most restrictive for 85 Kr and 239 Pu-TRU <1y , with DFs of 3 and 6.1E+09, respectively. The dose-based limit as derived from 40 CFR 190.10(a) could require mitigation of tritium in some scenarios, with an estimated DF of about 3 for the reference scenarios. The fuel cycle-based limit for 129 I resulted in a DF of about 240 for the reference scenario. The need for iodine mitigation based on dose to the public depended upon the physical form of iodine as either particulate or vapor-phase species. Emission of iodine from the facility as a vapor necessitated DFs of about 2 but emission as a particulate would require DFs >6,000 to meet thyroid dose-based limits. Effects of physical form on needed iodine mitigation are significant, but the understanding of speciation of iodine both during electrochemical reprocessing and after release to the atmosphere is limited. The electrochemical processing unit operations were evaluated to identify potential release points for the volatile radionuclides and to assess the potential for retention of the radionuclides within the process (thus decreasing the need for mitigation). Mitigation strategies for 3 H, 85 Kr, 129 I, and 239 Pu-TRU <1y were identified. In all cases, there are reasonably achievable pathways to regulatory compliance, although in some cases additional R&D is merited to verify the chemical speciation of these isotopes and to develop and demonstrate potential treatment technologies for this application. Whether or not additional off-gas controls (beyond common operations such as HEPA filtration and oxygen and moisture control) are needed for any of these regulated or volatile radionuclides depends on the (a) type of facility (NRC-regulated or DOE), (b) used fuel process rate, (c) used fuel burnup and composition, (d) speciation and retention of volatile radionuclides in the process and in the cell gas cleanup system, (e) site-specific parameters such as location, meteorology, stack height, and site boundaries, and (f) levels of conservatism and safety factors used in assessing compliance to air emissions regulations. Performance of this assessment revealed several areas where information is lacking or additional research is required in order to better determine if or what kinds of off-gas control might be needed. First, and most significantly, the understanding of the chemical speciation and physical form and partitioning of iodine during electrochemical processing operations is lacking and prevents the ability to accurately assess the potential iodine mitigation requirements. Future research in this area should be multifaceted and include thermodynamic modeling of iodine speciation in different process steps, experiments to quantify the kinetics of vapor-phase and melt-phase transitions, bench-scale experiments to determine the potential chemical and physical form of iodine emissions from the electrorefining process, and verification of iodine behavior with experiments utilizing operational facilities. Similarly, an improved understanding of iodine behavior in the environment after release from the facility stack will be required to refine dose estimations, as particulate and vapor-phase emissions result in significantly different doses to the MEI.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Overview of Issues Related to IEEE Std 1547-2018 Requirements Regarding Voltage and Reactive Power Control

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547 Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces (IEEE Std 1547-2018) was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concept and requires the appropriate information required to calculate relevant settings and configurations. Various stakeholders have different roles in implementing the standard, and portions of the standard are directed toward a specific audience who must possess specialized information and technical training to use and apply the requirements. This document aims to (1) summarize a specific portion of the standard as concisely as possible and (2) provide the reader with introductory knowledge and information to support the utilization of the requirements.

14 SOLAR ENERGY↗

Community Requirements Meta-Analysis: Characterizing Needs and Opportunities for HPDF

This High Performance Data Facility (HPDF) Project is creating a new scientific user facility to provide advanced infrastructure for data-intensive science, supporting the DOE’s Office of Science (SC) community. HPDF’s mission is to enable and accelerate scientific discovery by delivering state-of-the-art data management infrastructure, capabilities, and tools. This meta-analysis examines the needs of the breadth of the SC community, captured in publicly available community reports or mission documents. The meta-analysis identifies and provides initial characterization of fifteen core requirements for the HPDF Project team to consider during the conceptual design phase. The fifteen requirements illustrate how scientific work among SC communities requires modern, seamless user experiences across the ASCR Ecosystem to advance the use of large volumes of heterogeneous data. The scientific community requires support for the missing middle of compute between local and HPC to interactively and collaboratively use growing datasets. Data producers and end users will benefit from enhanced data catalogs and portals that improve data access through advanced search of well curated data. The fifteen requirements are examined here organized across five themes for discussion. Examples in each theme illustrate the array of scientific needs that convey the important role that the fully realized and operational High Performance Data Facility will be able to play as an integral part of the evolving ASCR Ecosystem. Our amalgamated data tables from ESnet reports demonstrate ranges to the volumes of data HPDF must be concerned with, but limitations are inherent to this meta-analysis (see Key Challenges & Limitations). Feedback and validation of these requirements along with additional details and emergent community requirements will be gathered through user research and design activities.

97 MATHEMATICS AND COMPUTING↗

Enabling Marine Energy Integration for Ocean Observing: Functional Requirements

Marine renewable energy (i.e., wave, tidal or ocean current, thermal gradient, and salinity gradient) or MRE can revolutionize ocean observing capabilities. Five use cases representing a range of ocean observing platforms were developed based on end-user feedback. Drawing from these use cases, common needs or functional requirements were developed to help guide the integration of MRE power delivery for ocean observation structures and functions. The functional requirements were determined from descriptions of the use cases, specifications of hardware that are used or closely associated with existing ocean observation platforms, and direct feedback from ocean observation sensor/platform developers and users. Twenty types of functional requirements were identified, including those associated with power and energy use; physical system requirements; temperature and depth; electrical, acoustic, and motion interference; and reliability. Each set of functional requirements is illustrated as features of the use cases. By defining functional requirements for MRE technology integration in ocean observing platforms, and focusing on end-user requirements, barriers to developing MRE-driven ocean observation missions can be reduced.

Cavagnaro, Robert J.↗

Background Information on the Power Quality Requirements in IEEE Std 1547-2018

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547-2018, Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces, was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, and energy storage systems with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects that are important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concepts and requires appropriate information to calculate relevant settings and configurations. This document provides informative material on the requirements related to electrical power quality in IEEE Std 1547-2018, with the intent to equip the reader with basic knowledge and background information to improve understanding and use of the requirements specified.

14 SOLAR ENERGY↗

Cyber-Informed Engineering Requirements Framework Use Cases

The requirement analysis use case effort leverages the Cyber-Informed Engineering (CIE) requirements framework to examine two real-world scenarios: Battery Energy Storage System (BESS) installation at the Flatirons Campus, NLR; SCADA improvement program. This work evaluates the existing requirements for each use case, applies the CIE requirements framework, and assesses the benefits and enhancements gained compared to the current requirements. The results will advance CIE from concept to practical application by identifying key opportunities for integrating CIE principles into established engineering workflows during the requirements phase.

97 MATHEMATICS AND COMPUTING↗

Design Requirements and Software Specification for the Autonomous Energy Management Software System for Small Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems. Many of these buildings are small (<50,000 square feet), underserved, and use rooftop units for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the rooftop units heating and cooling set points, schedules, setbacks, and optimal start can result in 20 to 25 percent reduction in electricity consumption in small commercial buildings. In addition, improving demand flexibility of these buildings will result additional cost savings for the building owner. Therefore, the Department of Energy’s Building Technologies Office approved a project to address the needs for small commercial buildings. The project is led by Pacific Northwest National Laboratory (PNNL) with Intellimation LLC as the cooperative research and development agreement partner. The primary goal of the project is to develop and validate an autonomous energy management software (AEMS) system that will continuously optimize small commercial building operations by minimizing energy consumption and cost, while providing a solution for maximizing decarbonization benefits from electrification of buildings. The work will leverage the vast experience of PNNL research and development staff who have over two decades of experience in developing and successfully transferring software technologies to the private sector. This solution will be jointly developed with Intellimation, a company that plans to use it to scale their building energy efficiency (EE) and grid services offering. Widespread deployment of the AEMS system will improve the EE and demand flexibility of the building commercial building stock. It should also support cities and states in meeting their climate change mitigation goals. This document describes the various EE and grid service features of the AEMS system, infrastructure and data required to implement those features, and how the features should be automated. It also details how the various features will be tested and validated, including field validation. The document also details what flexibility the users have and how they will be able to leverage those capabilities exercise those. The intent is to create an AEMS system that would support scalable deployment, requires minimal configuration, and is easy to maintain over its expected lifespan. The initial alpha release of AEMS system is planned for March 2023, and the beta release is planned for the summer of 2023. The final release is planned for March 2024. Section 2 of the report documents the relevant building types that AEMS is suitable for. Section 3 documents EE features that will be supported. It will also include the data requirements, hardware requirements, implementation details, and how EE features will be tested and validated. Grid service features will be documented in section 4, including data requirements, hardware requirements, implementation details, and how the services will be tested and validated. Planned next steps are described in section 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LAMP Project Facility and Space Requirements

The project will require significant space over the lifetime of the project to successfully execute design, technology maturation, component testing and verification, and final removal and installation. The types of space required falls into three general categories: office, storage, and laboratory. Figure 1 below summarizes the project space requirements by project lifecycle. The specific color coding indicates the availability (and potential risk to the project) of the particular type of space: green indicates space that is already allocated and in use by the LAMP project; yellow indicates space that is expected to be easily transitioned from its current use to the project; red indicates a space that is use by multiple users or other projects, and will most likely require high-level negotiations and planning to become available to the project. Figure 2 summarizes the LAMP Space Requirements by calendar year and type throughout the duration of the project. As can be seen in Fig. 2, the maximum space needed by the project exceeds 40,000 square feet, with an average space requirement over the lifetime of the project equal to approximately 25,000 square feet.

43 PARTICLE ACCELERATORS↗

Recommendations for Minimum Required Diagnostics Information

The rapid growth of electrified transportation, including light- and medium-duty electric vehicles (EVs) as a mobility solution requires a reliable EV-charging infrastructure. To advance charging reliability, the ChargeX Consortium reports “Recommendations for Minimum Required Error Codes for Electric Vehicle Charging Infrastructure” and “Implementation Guide for Minimum Required Error Codes in Electric Vehicle Charging Infrastructure” provided recommendations for a set of minimum required error codes (MRECs), their functional and responsibility classifications, and a guide for their implementation, using Open Charge Point Protocol (OCPP) versions 1.6J4 and 2.0.1.5 These reports outline a recommended practice for consistent error reporting and interpretation, which is essential for communicating issues uniformly across the complex and diverse EV-charging ecosystem. However, MRECs are just one part of diagnosing issues; another critical part is obtaining enough information about the current state and performance of the various charging components to identify root causes for each of the error codes. This additional diagnostics data can be used by technicians or automated systems to understand the context around an issue, allowing for timely resolution, decreased maintenance costs, and increased charging reliability. During everyday operations, data are regularly collected and analyzed across the ecosystem. Although sharing of all that available data would be great for diagnostics, concerns on data ownership, privacy, and original equipment manufacturer (OEM) intellectual property pose a challenge. To overcome this obstacle, this report proposes a set of minimum required diagnostic information (MRDI) and recommends that the industry implement these uniformly across the North American EV charging ecosystem. MRDI provides a means to exchange only data deemed necessary for root cause determination.

33 ADVANCED PROPULSION SYSTEMS↗

Recommendations for Minimum Required Diagnostics Information for Electric Vehicle Charging Infrastructure

The rapid growth of electrified transportation, including light- and medium-duty electric vehicles (EVs) as a mobility solution requires a reliable EV charging infrastructure. To advance charging reliability, the ChargeX Consortium reports “Recommendations for Minimum Required Error Codes for Electric Vehicle Charging Infrastructure” and “Implementation Guide for Minimum Required Error Codes in Electric Vehicle Charging Infrastructure” have provided recommendations for a set of minimum required error codes (MRECs), their functional and responsibility classifications, and a guide for their implementation using OCPP versions 1.6J and 2.0.1. These reports outline a recommended practice for consistent error reporting and interpretation, which is essential for communicating issues uniformly across the complex and diverse EV charging ecosystem. However, MRECs are just one part of diagnosing issues, another critical part is obtaining enough information about the current state and performance of the various charging components to identify root causes for each of the error codes. This additional diagnostics data can be used by technicians or automated systems to understand the context around an issue, allowing for timely resolution, decreased maintenance costs, and increased charging reliability. During everyday operations, data is regularly collected and analyzed across the ecosystem. Although sharing of all that available data would be great for diagnostics, concerns on data ownership, privacy, and OEM intellectual property pose a challenge. To overcome this obstacle, this report proposes a set of Minimum Required Diagnostic Information (MRDI) and recommends that the industry implement these uniformly across the North American EV charging ecosystem. MRDI provides a means to exchange only data deemed necessary for root cause determination.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

TEV-3349 "ATF-2 2A Loop Pin Cladding Requirements"

Industry partners, including Westinghouse, Framatome, General Electric, General Atomics, Toshiba, etc. require requirements for fuel pins they insert in the reactor for testing. This document contains those requirements. These requirements represent an agreement between ATR and NS&T, and include the requirements for pins fabricated at the INL. These include inspections such as radiography, helium leak check, etc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗