Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Joint X-ray and neutron refinement with phenix.refine

The implementation of crystallographic structure-refinement procedures that include both X-ray and neutron data (separate or jointly) in the PHENIX system is described. Approximately 85% of the structures deposited in the Protein Data Bank have been solved using X-ray crystallography, making it the leading method for three-dimensional structure determination of macromolecules. One of the limitations of the method is that the typical data quality (resolution) does not allow the direct determination of H-atom positions. Most hydrogen positions can be inferred from the positions of other atoms and therefore can be readily included into the structure model as a priori knowledge. However, this may not be the case in biologically active sites of macromolecules, where the presence and position of hydrogen is crucial to the enzymatic mechanism. This makes the application of neutron crystallography in biology particularly important, as H atoms can be clearly located in experimental neutron scattering density maps. Without exception, when a neutron structure is determined the corresponding X-ray structure is also known, making it possible to derive the complete structure using both data sets. Here, the implementation of crystallographic structure-refinement procedures that include both X-ray and neutron data (separate or jointly) in the PHENIX system is described.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stereolithographic Fabrication of a Flow Cell For Improved Neurochemical Sensor Testing

The human brain remains a mystery to researchers. Scientists at Lawrence Livermore National Laboratory (LLNL) have developed highly sensitive and flexible multimodal multielectrode arrays (MEAs) with the potential to be both powerful diagnostic and therapeutic tools when dealing with neurological ailments such as Alzheimers, Parkinson’s, Post Traumatic Stress Disorder, and Traumatic Brain Injuries. These MEAs include biosensors in addition to electrodes for electrical stimulation and recording. The transition from the traditional rigid neural probes to the flexible MEAs has led LLNL researchers on the search for alternative testing and characterization methods for flexible devices in vitro. The rigid devices have been shown to be more abrasive and damaging to the brain when implanted, but due to their rigidity – are more robust and resilient to noise artifacts in in vitro testing. The flexible MEAs, similar in size and flexibility to a human hair, cause much less damage in the brain but have had a difficult time maintaining their integrity and collecting data without high-levels of noise due to the formation of inertial eddies (due to increased turbulent flow) moving the flexible MEA during in vitro testing. The goal of this project was to design a fluidic cell to allow for a more constant electrochemical testing & characterization of biosensors on these flexible MEAs. Design and fabrication of the fluidic cell was through the use of CAD software and a stereolithography printer using clear photopolymer resin (appropriate for biomedical use and quality resolution). Flow cells facilitate analyte delivery to biosensor surfaces in a more constant and controlled fashion, allowing for –in this case –a better electrodeposition of thin-film Platinum-Iridium (Pt-Ir) on MEAs of 16 Platinum disc electrodes 50µm in diameter. Platinum-Iridium alloy electrodes have been widely used in biomedical and industrial applications. Iridium adds mechanical stiffness to platinum. PtIr is a FDA approved electrode material for human implantable devices.

36 MATERIALS SCIENCE↗

Computer graphics application in the engineering design integration system

The computer graphics aspect of the Engineering Design Integration (EDIN) system and its application to design problems were discussed. Three basic types of computer graphics may be used with the EDIN system for the evaluation of aerospace vehicles preliminary designs: offline graphics systems using vellum-inking or photographic processes, online graphics systems characterized by direct coupled low cost storage tube terminals with limited interactive capabilities, and a minicomputer based refresh terminal offering highly interactive capabilities. The offline line systems are characterized by high quality (resolution better than 0.254 mm) and slow turnaround (one to four days). The online systems are characterized by low cost, instant visualization of the computer results, slow line speed (300 BAUD), poor hard copy, and the early limitations on vector graphic input capabilities. The recent acquisition of the Adage 330 Graphic Display system has greatly enhanced the potential for interactive computer aided design.

Glatt, C. R.↗

An ultrahigh vacuum multipurpose specimen chamber with sample introduction system for in situ transmission electron microscopy investigations

A commercial transmission electron microscope (TEM), with flat-plate upper pole piece configuration of the objective lens, and top-entry specimen introduction was modified by introducing an ultrahigh vacuum (UHV) specimen chamber for in situ TEM experimentation. The pumping and design principles and special features of this UHV chamber, which makes it possible to obtain 5 x 10 to the -10th mbar pressure at the site of the specimen, while maintaining the airlock system that allows operation in the 10 to the -10th mbar range within 15 min after specimen change, are described. Design operating pressures and image quality (resolution of metal particles smaller than 1 nm in size) were achieved. Schematic drawings and design dimensions are included.

Heinemann, K.↗

Data for Renewable Energy Planning, Policy, and Investment

Reliable, robust, and validated data are critical for informed planning, policy development, and investment in the clean energy sector. The Renewable Energy (RE) Explorer was developed to support data-driven renewable energy analysis that can inform key renewable energy decisions globally. This document presents the types of geospatial and other data at the core of renewable energy analysis and decision making. Individual data sets used to inform decisions vary in relation to spatial and temporal resolution, quality, and overall usefulness. From Data to Decisions, a complementary geospatial data and analysis decision guide, provides an in-depth view of these and other considerations to enable data-driven planning, policymaking, and investment. Data support a wide variety of renewable energy analyses and decisions, including technical and economic potential assessment, renewable energy zone analysis, grid integration, risk and resiliency identification, electrification, and distributed solar photovoltaic potential. This fact sheet provides information on the types of data that are important for renewable energy decision making using the RE Data Explorer or similar types of geospatial analysis tools.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Production of the thermal scattering law and neutron scattering cross sections for ice from first principles - 14503

Water ice can exist in many polymorphic phases as a result of the wide range of geometric ordering possible for the hydrogen bonds between H{sub 2}O molecules. Ice Ih, which can form under normal atmospheric pressure at 273 K, is the most common type. Ab initio density functional theory, incorporating the generalized gradient approximation (GGA) for the exchange-correlation energy, is used to simulate the hexagonal structure of ice Ih and calculate phonon dispersion relations with harmonic lattice dynamics. While the unit cell for ice Ih contains four molecules with particular alignments of the H{sub 2}O molecules possible, the structure has globally disordered proton arrangement. To improve capturing this random distribution, a 12-molecule unit cell is incorporated along with a 2x2x2 supercell. The total phonon density of states is determined by randomly sampling dispersion relations in the first Brillouin zone. The translational, librational, bending, and stretching modes are produced with high-quality resolution and are consistent with the optical peaks and ranges observed in Raman, infrared, and inelastic neutron scattering experiments [1]. The phonon spectrum is used to calculate the S(α,β) thermal scattering law for ENDF [2] publication in the incoherent approximation, which is appropriate due to the relatively small coherent nuclear scattering cross section for H{sub 2}O. These theoretical results are compared to experimental S(α,β) at 268 K [3] and trends are found to be in good agreement. Finally, total scattering cross sections are calculated by integrating over S(α,β) to determine the incoherent inelastic cross sections and then separately adding the absorption and incoherent elastic components. These results are compared to experimental total cross sections for ice Ih at 115 K over a range of incident energies [4] and found to provide excellent agreement. (authors)

42 ENGINEERING↗

The effect of horizontal resolution on simulation quality in the Community Atmospheric Model, CAM5.1

We present an analysis of version 5.1 of the Community Atmospheric Model (CAM5.1) at a high horizontal resolution. Intercomparison of this global model at approximately 0.25°, 1°, and 2° is presented for extreme daily precipitation as well as for a suite of seasonal mean fields. In general, extreme precipitation amounts are larger in high resolution than in lower-resolution configurations. In many but not all locations and/or seasons, extreme daily precipitation rates in the high-resolution configuration are higher and more realistic. The high-resolution configuration produces tropical cyclones up to category 5 on the Saffir-Simpson scale and a comparison to observations reveals both realistic and unrealistic model behavior. In the absence of extensive model tuning at high resolution, simulation of many of the mean fields analyzed in this study is degraded compared to the tuned lower-resolution public released version of the model.

58 GEOSCIENCES↗

Evaluation of Matrix9 silicon photomultiplier array for small-animal PET

Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm{sup 2} and the total size of the detector head is 47.8 × 46.3 mm{sup 2}. Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can resolve high-resolution scintillator arrays common in small-animal PET with adequate energy resolution and timing resolution over a large detector area. The modular design of the Matrix9 detector allows it to be used as a building block for simple, low channel-count, yet high performance, small animal PET or PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA's Next Generation of Atmospheric Data Science

The Multi-Angle Imager for Aerosols (MAIA) and the Tropospheric Emission: Monitoring of Pollution(TEMPO) are NASA’s next-generation satellite missions for air quality monitoring. These missions will produce high-quality, high-resolution air quality data to support cross-displinary research. The MAIA mission is collaborating with health science researchers and epidemiologists to study the impacts of air quality on health outcomes. TEMPO aims to improve our understanding of tropospheric air pollution chemistry and our ability to make predictions about air quality and climate forcing. TEMPO will offer hourly measurements of tropospheric ozone, aerosols, and clouds focused on North America at high-spatial resolution, while MAIA will produce high-resolution measurements of speciated particulate matter targeting densely populated cities around the globe. Data from these missions will help improve our understanding of the sources, types, and interactions among the aerosols and trace gases that are polluting Earth’s atmosphere, as well as our understanding of the impact of air pollution on pollution on a wide range of important areas including human health, agriculture, weather, and climate change. The challenges of cross-disciplinary research, computationally expensive multi-variate analyses, and high-resolution data at both local and global scales are driving substantial changes across all of NASA’s Distributed Active Archive Centers (DAACs). High resolution data at scales such these requires a new approach to data ingest, archive, and publication. Like other NASA DAACs, the Atmospheric Science Data Center (ASDC), the DAAC that will be responsible for publishing MAIA and TEMPO data products has historically archived and distributed data on premise. DAACs of the future will archive and distribute data in the cloud, enabling them to remake themselves as research-focused data centers that will support on-demand, data-intensive computations for highly accurate retrospective analyses and predictions. Under the new paradigm, data formats and metadata must support on-demand spatial and temporal sub-setting, as well as other data transformation services such as re-gridding and re-sampling. This presentation will discuss work being done to address data formatting and metadata requirements in this dynamic new environment. In addition to the changes in data stewardship practices at the ASDC, the increased focus on supporting scientific research is driving changes in the relationship between DAACs and researchers. While the ASDC will continue to provide first rate data management and stewardship, it is increasingly focused on serving as a partner not only to the science teams that gather and produce the data it publishes, but to the researchers that use that data.

Beth Huffer↗

In situ correlative measurements for the ultraviolet differential absorption lidar and the high spectral resolution lidar air quality remote sensors: 1980 PEPE/NEROS program

In situ correlative measurements were obtained with a NASA aircraft in support of two NASA airborne remote sensors participating in the Environmental Protection Agency's 1980persistent elevated pollution episode (PEPE) and Northeast regional oxidant study (NEROS) field program in order to provide data for evaluating the capability of two remote sensors for measuring mixing layer height, and ozone and aerosol concentrations in the troposphere during the 1980 PEPE/NEROS program. The in situ aircraft was instrumented to measure temperature, dewpoint temperature, ozone concentrations, and light scattering coefficient. In situ measurements for ten correlative missions are given and discussed. Each data set is presented in graphical and tabular format aircraft flight plans are included.

Gregory, G. L.↗

MPAS - Ocean Simulation Quality for Variable-Resolution North American Coastal Meshes

Climate model components utilizing unstructured meshes enable variableresolution, regionally enhanced simulations within global domains. Here we investigate the relationship between mesh quality and simulation statistics using the JIGSAW unstructured meshing library and the Model for Prediction Across ScalesOcean (MPASOcean) with a focus on Gulf Stream dynamics. In the base configuration, the refined region employs 8 km cells that extend 400 km from the coast of North America. This coastal refined region is embedded within a lowresolution global domain, with cell size varying latitudinally between 30 and 60 km. The resolution transition region between the refined region and background mesh is 600 km wide. Three sensitivity tests are conducted: 1) the quality of meshes is intentionally degraded so that horizontal cells are progressively more distorted; 2) the transition region from high to low resolution is steepened; and 3) resolution of the coastal refinement region is varied from 30 km to 8 km. Overall, the ocean simulations are shown to be robust to mesh resolution and quality alterations. Meshes that are substantially degraded still produce realistic currents, with Southern Ocean transports within 0.4% and Gulf Stream transports within 12% of highquality mesh results. The narrowest transition case of 100 km did not produce any spurious effects. Refined regions with high resolution produce eddy kinetic energy and sea surface height variability that are similar to the highresolution reference simulation. These results provide heuristics for the design criteria of variableresolution climate model domains.

Hoch, Kristin E.↗