Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution test pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Benchmark Modeling of the Near-Field and Far-Field Wave Effects of Wave Energy Arrays

This project is an industry-led partnership between Columbia Power Technologies and Oregon State University that will perform benchmark laboratory experiments and numerical modeling of the near-field and far-field impacts of wave scattering from an array of wave energy devices. These benchmark experimental observations will help to fill a gaping hole in our present knowledge of the near-field effects of multiple, floating wave energy converters and are a critical requirement for estimating the potential far-field environmental effects of wave energy arrays. The experiments will be performed at the Hinsdale Wave Research Laboratory (Oregon State University) and will utilize an array of newly developed Buoys' that are realistic, lab-scale floating power converters. The array of Buoys will be subjected to realistic, directional wave forcing (1:33 scale) that will approximate the expected conditions (waves and water depths) to be found off the Central Oregon Coast. Experimental observations will include comprehensive in-situ wave and current measurements as well as a suite of novel optical measurements. These new optical capabilities will include imaging of the 3D wave scattering using a binocular stereo camera system, as well as 3D device motion tracking using a newly acquired LED system. These observing systems will capture the 3D motion history of individual Buoys as well as resolve the 3D scattered wave field; thus resolving the constructive and destructive wave interference patterns produced by the array at high resolution. These data combined with the device motion tracking will provide necessary information for array design in order to balance array performance with the mitigation of far-field impacts. As a benchmark data set, these data will be an important resource for testing of models for wave/buoy interactions, buoy performance, and far-field effects on wave and current patterns due to the presence of arrays. Under the proposed project we will initiate high-resolution (fine scale, very near-field) fluid/structure interaction simulations of buoy motions, as well as array-scale, phase-resolving wave scattering simulations. These modeling efforts will utilize state-of-the-art research quality models, which have not yet been brought to bear on this complex problem of large array wave/structure interaction problem.

16 TIDAL AND WAVE POWER↗

A simple model for estimating changes in rainfall erosivity caused by variations in rainfall patterns

Highlights: • A simple relationship was developed for predicting daily erosivity in changing climates. • The relationship depends on precipitation amount and maximum 0.5-h intensity I{sub 0.5} . • The relationship was calibrated using measured climate data and had a R{sup 2} of 0.99. • Simulated daily and annual erosivities were predicted with a R{sup 2} of 0.99 using the relationship. • The relationship was tested using I{sub 24}, showing a R{sup 2} of 0.78 for the simulated data. A major challenge when coupling soil loss models with precipitation forecasts from Global Circulation Models (GCMs) is that their time resolutions do not generally agree. Precipitation forecasts from GCM must be scaled down; however, the distribution of the rainfall intensity, which can affect soil loss as much as precipitation amounts, is usually not considered in this process. Therefore, the objective of this study was to develop a statistical equation for computing event-based rainfall erosivity under changing precipitation patterns using the least amount of information possible. For this purpose, an empirical equation for predicting event-based rainfall erosivity was developed using the product of the total precipitation P and the maximum 0.5-h rainfall intensity, I{sub 0.5}. This equation was calibrated using measured precipitation data from 28 sites in Central Chile and then tested with simulated data with different rainfall patterns from the CLIGEN (CLImate GENerator) weather generator. More than 53,000 rainfall events were analyzed, where the equation consistently provided R{sup 2} values of 0.99 for every dataset used, revealing its robustness when used in potential climate change scenarios in the study site. However, because computing I{sub 0.5} requires estimating precipitation at a high time resolution, the relationship was recalibrated and tested using 1 through 24-h maximum rainfall intensities. Using these intensities, the equation provided erosivity estimates with R{sup 2} ranging from 0.78 to 0.99, where better results were obtained as the resolution of the data increased. This study provides the methodology for building and testing the proposed equation and discusses its advantages and limitations.

54 ENVIRONMENTAL SCIENCES↗

X-ray Microdiffraction Characterization of Deformation Heterogeneities in BCC Crystals

The deformation behavior of BCC metals is being investigated by x-ray microdiffraction measurements ({mu}XRD) for the purpose of characterizing the dislocation structure that results from uniaxial compression experiments. The high brilliance synchrotron source at the Advanced Light Source (Lawrence Berkeley National Lab) and the micron resolution of the focusing optics allow for the mapping of Laue diffraction patterns across a sample. These measurements are then analyzed in order to map the distribution of residual stresses in the crystal. An important finding is the observation of Laue spot 'streaking', which indicates localized rotations in the lattice. These may represent an accumulation of same-sign dislocations. Theoretical modeling of the diffraction response for various slip systems is presented, and compared to experimental data. Preliminary results include orientation maps from a highly strained Ta bicrystal and a less highly strained Mo single crystal. The orientation maps of the bicrystal indicate a cell-like structure of dense dislocation walls. This deformation structure is consistent with previous OIM studies of the same crystal. The results suggest that {mu}XRD may be a particularly useful tool for microscale studies of deformation patterns in a multi-scale investigation of the mechanisms of deformation that ranges from macroscopic deformation tests to high resolution TEM studies of dislocation structures.

43 PARTICLE ACCELERATORS↗

Measurement method for roll angular displacement with a high resolution by using diffraction gratings and a heterodyne interferometer

The roll angle measurement is difficult to be achieved directly using a typical commercial interferometer due to its low sensitivity in axial direction, where the axial direction is orthogonal to the plane of the roll angular displacement. A roll angle measurement method combined diffraction gratings with a laser heterodyne interferometer is discussed in this paper. The diffraction grating placed in the plane of a roll angular displacement and the interferometer arranged in the plane's orthogonal direction, constitute the measurement pattern for the roll angle with high resolution. The roll angular displacement, considered as the linear, can be tested precisely when the corresponding angle is very small. Using the proposed method, the angle roll measurement obtains the high resolution of 0.002{sup ″}. Experiment has proved its feasibility and practicability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation tests of an improved kernel density estimation method for identifying disease clusters

The spatial filter method, which belongs to the class of kernel density estimation methods, has been used to make morbidity and mortality maps in several recent studies. We propose improvements in the method that include a spatial basis of support designed to give a constant standard error for the standardized mortality/morbidity rate; a stair-case weight method for weighting observations to reduce estimation bias; and a method for selecting parameters to control three measures of performance of the method: sensitivity, specificity and false discovery rate. We test the performance of the method using Monte Carlo simulations of hypothetical disease clusters over a test area of four counties in Iowa. The simulations include different types of spatial disease patterns and high resolution population distribution data. Results confirm that the new features of the spatial filter method do substantially improve its performance in realistic situations comparable to those where the method is likely to be used.

59 BASIC BIOLOGICAL SCIENCES↗

A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography

Purpose: Thousands of cone-beam computed tomography (CBCT) scanners for vascular, maxillofacial, neurological, and body imaging are in clinical use today, but there is no consensus on uniform acceptance and constancy testing for image quality (IQ) and dose yet. The authors developed a quality assurance (QA) framework for fully automated and time-efficient performance evaluation of these systems. In addition, the dependence of objective Fourier-based IQ metrics on direction and position in 3D volumes was investigated for CBCT. Methods: The authors designed a dedicated QA phantom 10 cm in length consisting of five compartments, each with a diameter of 10 cm, and an optional extension ring 16 cm in diameter. A homogeneous section of water-equivalent material allows measuring CT value accuracy, image noise and uniformity, and multidimensional global and local noise power spectra (NPS). For the quantitative determination of 3D high-contrast spatial resolution, the modulation transfer function (MTF) of centrally and peripherally positioned aluminum spheres was computed from edge profiles. Additional in-plane and axial resolution patterns were used to assess resolution qualitatively. The characterization of low-contrast detectability as well as CT value linearity and artifact behavior was tested by utilizing sections with soft-tissue-equivalent and metallic inserts. For an automated QA procedure, a phantom detection algorithm was implemented. All tests used in the dedicated QA program were initially verified in simulation studies and experimentally confirmed on a clinical dental CBCT system. Results: The automated IQ evaluation of volume data sets of the dental CBCT system was achieved with the proposed phantom requiring only one scan for the determination of all desired parameters. Typically, less than 5 min were needed for phantom set-up, scanning, and data analysis. Quantitative evaluation of system performance over time by comparison to previous examinations was also verified. The maximum percentage interscan variation of repeated measurements was less than 4% and 1.7% on average for all investigated quality criteria. The NPS-based image noise differed by less than 5% from the conventional standard deviation approach and spatially selective 10% MTF values were well comparable to subjective results obtained with 3D resolution pattern. Determining only transverse spatial resolution and global noise behavior in the central field of measurement turned out to be insufficient. Conclusions: The proposed framework transfers QA routines employed in conventional CT in an advanced version to CBCT for fully automated and time-efficient evaluation of technical equipment. With the modular phantom design, a routine as well as an expert version for assessing IQ is provided. The QA program can be used for arbitrary CT units to evaluate 3D imaging characteristics automatically.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precise measurement of the resolution in light microscopy using Fourier transform

The resolution power of light microscope has been accurately measured ({+-}5%) by Fourier transform of various object images and further evaluation of the highest spatial frequency in Fourier spectrum. Any unknown shape plane object with a shape feature's size smaller than the resolution to be measured was shown to provide a reliable resolution test. This simple method gives a direct measurement of the resolution power as defined by Abbe [Archiv. F. Mikroskopische Anat. 9, 413 (1873)]. The results have been justified by comparison to a standard resolution measurement by using calibrated periodic line patterns. Notably, the approach is applicable in super-resolution light microscopy (transmission, reflection, and fluorescence), where calibrated resolution targets do not occur. It was conveniently implemented by using a compact disk as a test object and free IMAGEJ imaging software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The study of stress application and corrosion cracking on Ni-16 Cr-9 Fe (Alloy 600) C-ring samples by polychromatic X-ray microdiffraction

Microscopic strains associated with stress corrosion cracks have been investigated in stressed C-rings of Ni-16 Cr-9 Fe (Alloy 600) boiler tubing. Polychromatic X-ray microdiffraction was used to measure deviatoric strain tensors and the distribution of dislocations near cracks that had been propagated in electrochemically accelerated corrosion tests. An associated investigation of the C-ring-induced strains prior to corrosion showed significant tensile strain in the stress axis direction by the torsional closure of the alloy tube section in the C-ring test. Significant grain lattice rotation and pronounced plastic strain at some grain boundaries were noted. Stress-corrosion-cracking-generated intergranular cracks were produced in two Alloy 600 specimens after 6 h and 18 h tests. The diffraction patterns and resultant strain tensors were mapped around the cracked area to a 1 μm spatial resolution. The strain tensor transverse to the crack growth direction showed tensile strain at the intergranular region just ahead of the crack tip for both specimens. Both cracks were found to follow grain boundary pathways that had the lowest angle of misorientation. Dislocation distributions within each grain were qualitatively obtained from the shapes of the diffraction spots and the effect of 'hard' and 'soft' grains on the crack pathway was explored for both 6 h and 18 h specimens. The Schmid factor of one of the grains adjacent to the crack at the 6 h and 18 h initiation sites was found to be the lowest, compared to Schmid factors calculated for surface grains away from the initiation site, and also along the crack path into the bulk.

36 MATERIALS SCIENCE↗

Deep residual networks for crystallography trained on synthetic data

The use of artificial intelligence to process diffraction images is challenged by the need to assemble large and precisely designed training data sets. To address this, a codebase called Resonet was developed for synthesizing diffraction data and training residual neural networks on these data. Here, two per-pattern capabilities of Resonet are demonstrated: (i) interpretation of crystal resolution and (ii) identification of overlapping lattices. Resonet was tested across a compilation of diffraction images from synchrotron experiments and X-ray free-electron laser experiments. Crucially, these models readily execute on graphics processing units and can thus significantly outperform conventional algorithms. While Resonet is currently utilized to provide real-time feedback for macromolecular crystallography users at the Stanford Synchrotron Radiation Lightsource, its simple Python-based interface makes it easy to embed in other processing frameworks. This work highlights the utility of physics-based simulation for training deep neural networks and lays the groundwork for the development of additional models to enhance diffraction collection and analysis.

36 MATERIALS SCIENCE↗

Feasibility study of a dual detector configuration concept for simultaneous megavoltage imaging and dose verification in radiotherapy

Purpose: To test the feasibility of a dual detector concept for comprehensive verification of external beam radiotherapy. Specifically, the authors test the hypothesis that a portal imaging device coupled to a 2D dosimeter provides a system capable of simultaneous imaging and dose verification, and that the presence of each device does not significantly detract from the performance of the other. Methods: The dual detector configuration comprised of a standard radiotherapy electronic portal imaging device (EPID) positioned directly on top of an ionization-chamber array (ICA) with 2 cm solid water buildup material (between EPID and ICA) and 5 cm solid backscatter material. The dose response characteristics of the ICA and the imaging performance of the EPID in the dual detector configuration were compared to the performance in their respective reference clinical configurations. The reference clinical configurations were 6 cm solid water buildup material, an ICA, and 5 cm solid water backscatter material as the reference dosimetry configuration, and an EPID with no additional buildup or solid backscatter material as the reference imaging configuration. The dose response of the ICA was evaluated by measuring the detector’s response with respect to off-axis position, field size, and transit object thickness. Clinical dosimetry performance was evaluated by measuring a range of clinical intensity-modulated radiation therapy (IMRT) beams in transit and nontransit geometries. The imaging performance of the EPID was evaluated quantitatively by measuring the contrast-to-noise ratio (CNR) and spatial resolution. Images of an anthropomorphic phantom were also used for qualitative assessment. Results: The measured off-axis and field size response with the ICA in both transit and nontransit geometries for both dual detector configuration and reference dosimetry configuration agreed to within 1%. Transit dose response as a function of object thickness agreed to within 0.5%. All IMRT test patterns and clinical IMRT beams had gamma pass rates of ≥98% at 2%/2 mm criteria. In terms of imaging performance, the measured CNR and spatial resolution (f{sub 50}) were 263.23 ± 24.85 and 0.4025 ± 1.25 × 10{sup −3} for dual detector configuration and 324 ± 26.65 and 0.4141 ± 1.14 × 10{sup −3} for reference imaging configuration, respectively. The CNR and spatial resolution were quantitatively worse in the dual detector configuration due to the additional backscatter. The difference in imaging performance was not visible in qualitative assessment of phantom images. Conclusions: Combining a commercially available ICA dosimetry device with a conventional EPID did not significantly detract from the performance of either device. Further improvements in imaging performance may be achieved with an optimized design. This study demonstrates the feasibility of a dual detector concept for simultaneous imaging and dosimetry in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Patterning approach for detecting defect in device manufacturing

Compact handheld devices which were a dream in the past are now a reality; this has been enabled by miniaturization of circuit architectures including power devices. Scaling down of the design feature sizes does come with a price with an increase in systematic defects during chip manufacturing. There are generally two methods of inline defect detection adopted to monitor the semiconductor device fabrication—optical inspection and electron beam inspection. The optical inspection uses ultra-violet and deep ultra-violet (UV/DUV) light to find patterning defects on the wafer. While the electron-beam inspection uses electron charge and discharge measurement to find electrical connection defects, both are a costly procedure in terms of resources and time. The physical limit of feature resolution of the optical source is now making the defect inspection job difficult in miniaturized application specific integrated circuit (ASIC). This study is designed to test the patterning optimization approach on both inspection platforms. Using hotspot analysis weak locations are identified in the full chip design, and then they are verified in the inline wafer inspection. The criterion for hot-spot determination is also discussed in this paper.

36 MATERIALS SCIENCE↗

Microstructural strain mapping during in-situ cyclic testing of ductile iron

Highlights: • A method for quantitative study of crack formation and propagation during cyclic loading was developed. • Focused Ion Beam Milling was shown to be an effective method to generate a high quality speckle pattern for Digital Image Correlation measurements • The method enabled a high-resolution measurement of localized strain in the microstructure of ductile iron • The peak strain and the strain distribution ahead of the growing crack under load were quantified - Abstract: This paper focuses on local strain distribution in the microstructure of high silicon ductile iron during cyclic loading. In-situ cyclic test was performed on compact-tension (CT) samples inside the scanning electron microscope (SEM) to record the whole deformation and obtain micrographs for microstructural strain measurement by means of digital image correlation (DIC) technique. Focused ion beam (FIB) milling was used to generate speckle patterns necessary for DIC measurement. The equivalent Von Mises strain distribution was measured in the microstructure at the maximum applied load. The results revealed a heterogeneous strain distribution at the microstructural level with higher strain gradients close to the notch of the CT sample and accumulated strain bands between graphite particles. Local strain ahead of the early initiated micro-cracks was quantitatively measured, showing high strain localization, which decreased by moving away from the micro-crack tip. It could be observed that the peak of strain in the field of view was not necessarily located ahead of the micro-cracks tip which could be because of the (i) strain relaxation due to the presence of other micro-cracks and/or (ii) presence of subsurface microstructural features such as graphite particles that influenced the strain concentration on the surface.

36 MATERIALS SCIENCE↗

Note: An X-ray powder diffractometer with a wide scattering-angle range of 72° using asymmetrically positioned one-dimensional detectors

An X-ray powder diffractometer has been developed for a time-resolved measurement without the requirement of a scattering angle (2θ) scan. Six one-dimensional detector modules are asymmetrically arranged in a vertical line at a designed distance of 286.5 mm. A detector module actually covers a diffraction angle of about 12° with an angular resolution of 0.01°. A diffracted intensity pattern is simultaneously recorded in a 2θ angular range from 1.63° to 74.37° in a “one shot” measurement. We tested the performance of the diffractometer with reference CeO{sub 2} powders and demonstrated diffraction measurements from an operating lithium-air battery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstructing an icosahedral virus from single-particle diffraction experiments

The first experimental data from single-particle scattering experiments from free electron lasers (FELs) are now becoming available. The first such experiments are being performed on relatively large objects such as viruses, which produce relatively low-resolution, low-noise diffraction patterns in so-called diffract-and-destroy experiments. We describe a very simple test on the angular correlations of measured diffraction data to determine if the scattering is from an icosahedral particle. If this is confirmed, the efficient algorithm proposed can then combine diffraction data from multiple shots of particles in random unknown orientations to generate a full 3D image of the icosahedral particle. We demonstrate this with a simulation for the satellite tobacco necrosis virus (STNV), the atomic coordinates of whose asymmetric unit is given in Protein Data Bank entry 2BUK.

59 BASIC BIOLOGICAL SCIENCES↗

Synthesis of new 1-benzyl tetrahydropyridin-4-ylidene piperidinium salts and their antiplasmodial and antitrypanosomal activities

Our last study revealed the distinct antiplasmodial and antitrypanosomal activities of 1-benzyl tetrahydropyridin-4-ylidene pyrrolidinium salts. Therefore, we prepared a series of new 1-benzyl tetrahydropyridin-4-ylidene ammonium salts with an alternative amino residue and varying substitution patterns at the benzyl group to investigate the influence of these modifications on the biological activities. All new compounds were characterized by spectroscopic methods like ultraviolet, infrared, nuclear magnetic resonance, as well as high- resolution mass spectra. They were tested for their activities against Plasmodium falciparum and Trypanosoma brucei rhodesiense as well as for their cytotoxicity against L6 cells using microplate assays. The results show that the structure of the amino residue as well as the substitution pattern of the benzyl group influences the biological activities distinctly. Physicochemical parameters are calculated and structure–activity relationships are discussed.

60 APPLIED LIFE SCIENCES↗

A Range and Performance Optimized Version of the Computer-Aided Speckle Interferometry Algorithm for Real-Time Displacement-Strain Field Monitoring

Abstract This work presents an optimized implementation of the Computer-Aided Speckle Interferometry algorithm which enables full-field determination of displacements and strains on commodity Graphics Processing Units at high resolution and frame rates. By combining careful control of the average speckle size in a laser speckle pattern with a simple sampling rate conversion scheme, a compact representation of the optical speckle is achieved. This allows for optimal use of Graphics Processing Unit architecture with robust range extension. The optimal mapping of the Computer-Aided Speckle Interferometry algorithm to Graphics Processing Unit architecture is shown in detail, and a straightforward method for disambiguating large displacements is illustrated. Lastly, this paper demonstrates a two-step subimage-tapering modification to the original algorithm that enables robust range enhancement while maintaining resolution. Results from numerical simulations on synthetic speckle patterns are shown, and runtime performance metrics are provided, with performance ranging up to 60 frames per second in some cases. The method is suitable for interactive experimental mechanics research, process and testing or any application where real-time high-resolution displacement-strain monitoring is needed. A .NET Framework class library enabling the incorporation of the algorithm into 3rd -party applications is available for download.

42 ENGINEERING↗

SU-F-T-549: Validation of a Method for in Vivo 3D Dose Reconstruction for SBRT Using a New Transmission Detector

Purpose: Recently, there has been increased clinical use of stereotactic body radiation therapy (SBRT). SBRT treatments will strongly benefit from in vivo patient dose verification, as any errors in delivery can be more detrimental to the radiobiology of the patient as compared to conventional therapy. In vivo dose measurements, a commercially available quality assurance platform which is able to correlate the delivered dose to the patient’s anatomy and take into account tissue inhomogeneity, is the COMPASS system (IBA Dosimetry, Germany) using a new transmission detector (Dolphin, IBA Dosimetry). In this work, we evaluate a method for in vivo 3D dose reconstruction for SBRT using a new transmission detector, which was developed for in vivo dose verification for intensity-modulated radiation therapy (IMRT). Methods: We evaluated the accuracy of measurement for SBRT using simple small fields (2×2−10×10 cm2), a multileaf collimator (MLC) test pattern, and clinical cases. The dose distributions from the COMPASS were compared with those of EDR2 films (Kodak, USA) and the Monte Carlo simulations (MC). For clinical cases, we compared MC using dose-volume-histograms (DVHs) and dose profiles. Results: The dose profiles from the COMPASS for small fields and the complicated MLC test pattern agreed with those of EDR2 films, and MC within 3%. This showed the COMPASS with Dolphin system showed good spatial resolution and can measure small fields which are required for SBRT. Those results also suggest that COMPASS with Dolphin is able to detect MLC leaf position errors for SBRT. In clinical cases, the COMPASS with Dolphin agreed well with MC. The Dolphin detector, which consists of ionization chambers, provided stable measurement. Conclusion: COMPASS with Dolphin detector showed a useful in vivo 3D dose reconstruction for SBRT. The accuracy of the results indicates that this approach is suitable for clinical implementation.

60 APPLIED LIFE SCIENCES↗

Species richness and endemism in the native flora of California

California’s vascular flora is the most diverse and threatened in temperate North America. Previous studies of spatial patterns of Californian plant diversity have been limited by traditional metrics, non-uniform geographic units, and distributional data derived from floristic descriptions for only a subset of species. We revisited patterns of sampling intensity, species richness, and relative endemism in California based on equal-area spatial units, the full vascular flora, and specimen-based distributional data. We estimated richness, weighted endemism (inverse range-weighting of species), and corrected weighted endemism (weighted endemism corrected for richness), and performed a randomization test for significantly high endemism. Possible biases in herbarium data do not obscure patterns of high richness and endemism at the spatial resolution studied. High species richness was sometimes associated with significantly high endemism (e.g., Klamath Ranges) but often not. In Stebbins and Major’s (1965) main endemism hotspot, Southwestern California, species richness is high across much of the Peninsular and Transverse ranges but significantly high endemism is mostly localized to the Santa Rosa and San Bernardino mountains. In contrast, species richness is low in the Channel Islands, where endemism is significantly high, as also found for much of the Death Valley region. Measures of taxonomic richness, even with greater weighting of range-restricted taxa, are insufficient for identifying areas of significantly high endemism that warrant conservation attention. Differences between our findings and those in previous studies appear to mostly reflect the source and scale of distributional data, and recent analytical refinements.

59 BASIC BIOLOGICAL SCIENCES↗