Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Enhancing the mass resolving power of FRIB’s proposed high-voltage MR-ToF mass separator and spectrometer: Addressing non-ideal conditions

Multi-reflection time-of-flight mass separators and spectrometers (MR-ToF MSs) are indispensable tools at radioactive ion beam (RIB) facilities. These electrostatic ion beam traps act as highly selective mass separators and high-precision mass spectrometers for rare and exotic nuclei. When well-tuned and designed to minimize higher-order flight-time aberrations, state-of-the-art MR-ToF MSs approach, and slightly exceed, mass resolving powers of m/Δm = 10 6 . Achieving m/Δm ≥ 3 ⋅ 10 6 would provide the ability to resolve > 90 % of all known isomeric states with half-lives above 10 ms. However, the ability to mass separate in all practical setups is limited by non-ideal conditions which place such resolving powers out of reach. Here, to this end, we present a simulated analysis of these conditions in the newly proposed high-voltage MR-ToF MS for the Facility for Rare Isotope Beams (FRIB). It is expected to store ions at 30 keV beam energy and increase ion throughput by two orders of magnitude compared to current devices. Existing efforts to mitigate the effects of non-ideal conditions employed for current MR-ToF devices storing ions at < 3 keV beam energy will already enable mass resolving powers approaching 10 6 for FRIB’s high-voltage MR-ToF device. Simulations of newly proposed mitigation strategies show that even mass resolving powers approaching 10 7 might become feasible.

Electrostatic ion beam traps↗

Coupling of horizontal, vertical, and temporal resolving power of a satellite temperature sounder

This paper examines the interconnection between the vertical, horizontal, and temporal resolving power of satellite temperature-sounding system. Using a temperature cross section produced by interpolating a set of RAOBs taken at three locations in Texas; Shreveport, Louisiana; Jackson, Mississippi; and Montgomery, Alabama, and an artificially constructed temperature cross section, it was found that the horizontal and temporal resolving power are subject to strong controls imposed by the vertical resolving power of the sounder. Thus, to improve the horizontal or temporal resolving power it is necessary to improve the vertical resolving power' of the satellite instrument itself, or to extend the a priori external information to include correct horizontal and temporal structure.

Thompson, Owen E.↗

Tachometer Derived From Brushless Shaft-Angle Resolver

Tachometer circuit operates in conjunction with brushless shaft-angle resolver. By performing sequence of straightforward mathematical operations on resolver signals and utilizing simple trigonometric identity, generates voltage proportional to rate of rotation of shaft. One advantage is use of brushless shaft-angle resolver as main source of rate signal: no brushes to wear out, no brush noise, and brushless resolvers have proven robustness. No switching of signals to generate noise. Another advantage, shaft-angle resolver used as shaft-angle sensor, tachometer input obtained without adding another sensor. Present circuit reduces overall size, weight, and cost of tachometer.

Howard, David E.↗

Towards time-resolved MicroED grid preparation using mix-and-inject gas dynamic virtual nozzles

Recent progress in gas dynamic virtual nozzle (GDVN) technologies in combination with high-brilliance synchrotron and X-ray free-electron lasers (XFELs) has allowed the visualization of protein dynamics in crystallo by mixing macromolecular protein crystals with a substrate using tunable mixing times on the order of milliseconds to seconds prior to serial X-ray diffraction data collection. This has become the method of choice for high-resolution structure determination of intermediate states. However, such experiments require large counts of crystals of proper sizes for high-resolution data collection, and premium beam times for screening efforts. Cryogenic microcrystal electron diffraction (MicroED) represents a complementary technique that may be a more accessible avenue for time-resolved nanocrystallography compared with serial X-ray diffraction experiments. MicroED can produce full diffraction datasets from just a few submicrometre-thick crystals, and the approach is more readily accessible, requiring standard cryogenic transmission electron microscopy (TEM) equipment available at many universities and institutes. Cryogenic MicroED, like other forms of cryo-EM, begins with rapidly freezing biological material on electron microscopy grids. In the case of MicroED, micro- to nano-crystals (<500 nm thick) are deposited onto electron microscopy grids and plunge-frozen for subsequent electron diffraction data collection. Here, we have incorporated GDVN technology developed originally for XFEL experiments into the freezing process as a first step towards time-resolved studies. We describe the limited deposition efficiency of the model MicroED protein proteinase K on TEM grids using GDVNs, preceding sample vitrification and successful MicroED data collection. We discuss both the initial results from such experiments and the methodological challenges in developing this approach into a reliable workflow for millisecond-to-second time-resolved structural studies of macromolecules. Our results promise a strategy to deposit crystals on grids using GDVNs and determine high-resolution structures by MicroED, constituting a first step towards development of time-resolved MicroED experiments.

MicroED↗

Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better detection via good peak separation with a longer run time is a better asset than moderate peak separation with a shorter run time. Even given that RESOLVE is highly interested in water and that mission timeline is of significant importance given the short seven-to-ten-day mission timeline, worse detection with an 8m column may lead to overlooking other substances existing on the moon that could advance planetary science. Thus, I recommend the 20m column. However, if mission timeline and water separation are deemed the highest priority, the 8m column should be selected due to its ability to separate water within a shorter run time than the 20m column.

Column↗

Reconstruction of boosted and resolved multi-Higgs-boson events with symmetry-preserving attention networks

The production of multiple Higgs bosons at the CERN LHC provides a direct way to measure the trilinear and quartic Higgs self-interaction strengths as well as potential access to beyond the standard model effects that can enhance production at large transverse momentum p T . The largest event fraction arises from the fully hadronic final state in which every Higgs boson decays to a bottom quark-antiquark pair ($b\bar{b}$). This introduces a combinatorial challenge known as the jet assignment problem: assigning jets to sets representing Higgs boson candidates. Symmetry-preserving attention networks (SPA-Nets) have been developed to address this challenge. However, the complexity of jet assignment increases when simultaneously considering both H → $b\bar{b}$ reconstruction possibilities, i.e., two “resolved” small-radius jets each containing a shower initiated by a b quark or one “boosted” large-radius jet containing a merged shower initiated by a $b\bar{b}$ pair. The latter improves the reconstruction efficiency at high p T . In this work, we introduce a generalization to the SPA-Net approach to simultaneously consider both boosted and resolved reconstruction possibilities and unambiguously interpret an event as “fully resolved”, “fully boosted”, or in between. We report the performance of baseline methods, the original SPA-Net approach, and our generalized version on nonresonant HH and HHH production at the LHC. Considering both boosted and resolved topologies, our SPA-Net approach increases the Higgs boson reconstruction purity by 56–80% and the efficiency by 37–38% compared to the baseline method depending on the final state.

Higgs Production↗

A Practical Framework for Simulating Time-Resolved Spectroscopy Based on a Real-Time Dyson Expansion

Time-resolved spectroscopy is a powerful tool for probing electron dynamics in molecules and solids, revealing transient phenomena on subfemtosecond time scales. The interpretation of experimental results is often enhanced by parallel numerical studies, which can provide insight and validation for experimental hypotheses. However, developing a theoretical framework for simulating time-resolved spectra remains a significant challenge. The most suitable approach involves the many-body nonequilibrium Green's function formalism, which accounts for crucial dynamical many-body correlations during time evolution. While these dynamical correlations are essential for observing emergent behavior in time-resolved spectra, they also render the formalism prohibitively expensive for large-scale simulations. Substantial effort has been devoted to reducing this computational cost─through approximations and numerical techniques─while preserving the key dynamical correlations. The ultimate goal is to enable first-principles simulations of time-dependent systems ranging from small molecules to large, periodic, multidimensional solids. Here, in this perspective, we outline key challenges in developing practical simulations for time-resolved spectroscopy, with a particular focus on Green's function methodologies. We highlight a recent advancement toward a scalable framework: the real-time Dyson expansion (RT-DE) [Phys. Rev. Lett. 2024, 133, 226902]. We introduce the theoretical foundation of RT-DE and discuss strategies for improving scalability, which have already enabled simulations of system sizes beyond the reach of previous fully dynamical approaches. We conclude with an outlook on future directions for extending RT-DE to first-principles studies of dynamically correlated, nonequilibrium systems.

Reeves, Cian C. [Univ. of California, Santa Barbar↗

Operando Depth-Resolved Measurement of Solvation Entropy, Interfacial Transport, and Charge-Transfer Kinetics in Lithium-Ion Batteries

Understanding and improving the performance and longevity of lithium-ion batteries critically depends on insight into the dynamic processes occurring at buried electrode-electrolyte interfaces. However, direct, depth-resolved, and operando diagnosis of these interfaces remains a longstanding challenge due to their inaccessibility beneath bulk materials, the limitations of conventional surface- and bulk-sensitive characterization tools, and the difficulty of maintaining realistic cell environments during measurement. These challenges have made it nearly impossible to uniquely resolve important interfacial properties such as charge transfer resistance, SEI (solid electrolyte interphase) resistance, and solvation entropy at the individual electrode interfaces within a working cell, information that is essential for mechanistic insight and accelerated battery design. Here, in this study, we report the development of multiharmonic electro-thermal spectroscopy (METS), an operando technique that enables depth-resolved measurement of solvation entropy, interfacial transport resistance, charge-transfer resistance, and SEI resistance at individual electrode-electrolyte interfaces within practical lithium-ion batteries. By leveraging frequency-dependent, thermal-wave sensing and interface-specific modeling, METS uniquely attributes interfacial properties to specific electrodes, as validated by comparison with traditional electrochemical impedance spectroscopy (EIS). The ability to spatially and temporally resolve interfacial processes in real time provides new diagnostic capabilities that are crucial for mechanistic studies of battery degradation and for the rapid development of next-generation energy storage systems.

Chalise, Divya [University of California, Berkeley↗

High Performance, High Fidelity: A GPU‐Accelerated Doubly‐Periodic Configuration of the Simple Cloud‐Resolving E3SM Atmosphere Model Version 1 (DP‐SCREAMv1)

The development of the Simplified Cloud Resolving Energy Exascale Earth System Atmosphere Model (SCREAMv1) enables global storm-resolving simulations on modern GPU-based supercomputers. However, the high computational cost of SCREAMv1 limits its routine use for process-level studies, creating a need for efficient proxy configurations. This study addresses this gap by introducing DP-SCREAMv1, a doubly periodic cloud-resolving model designed to be fully consistent with SCREAMv1 while enabling high-resolution, long-duration simulations at significantly reduced computational expense by simulating a limited doubly periodic domain rather than the entire globe. Built on a C++/Kokkos architecture, DP-SCREAMv1 achieves exceptional performance scalability on GPU systems and includes a rich library of cases for validation and scientific exploration. In this work, we demonstrate short wall-clock times at SCREAMv1's default resolution and show that DP-SCREAMv1 supports routine execution of large-domain, high-resolution experiments that were previously challenging in practice. Furthermore, we show that DP-SCREAMv1 enables routine execution of “Giga-LES” style simulations and facilitates large-domain, high-resolution simulations that were recently considered burdensome to perform. These results document an efficient, fully consistent process-level configuration for SCREAMv1 (DP-SCREAMv1) and illustrate its use for long-duration and large-domain experiments at cloud-resolving to eddy-permitting resolution.

Environmental sciences↗

Scaling and merging time-resolved pink-beam diffraction with variational inference

Time-resolved x-ray crystallography (TR-X) at synchrotrons and free electron lasers is a promising technique for recording dynamics of molecules at atomic resolution. While experimental methods for TR-X have proliferated and matured, data analysis is often difficult. Extracting small, time-dependent changes in signal is frequently a bottleneck for practitioners. Recent work demonstrated this challenge can be addressed when merging redundant observations by a statistical technique known as variational inference (VI). However, the variational approach to time-resolved data analysis requires identification of successful hyperparameters in order to optimally extract signal. In this case study, we present a successful application of VI to time-resolved changes in an enzyme, DJ-1, upon mixing with a substrate molecule, methylglyoxal. We present a strategy to extract high signal-to-noise changes in electron density from these data. Furthermore, we conduct an ablation study, in which we systematically remove one hyperparameter at a time to demonstrate the impact of each hyperparameter choice on the success of our model. We expect this case study will serve as a practical example for how others may deploy VI in order to analyze their time-resolved diffraction data.

47 OTHER INSTRUMENTATION↗

Time-resolved cryogenic electron tomography for the study of transient cellular processes

Cryogenic electron tomography (cryo-ET) is the highest resolution imaging technique applicable to the life sciences, enabling sub-nanometer visualization of specimens preserved in their near native states. The rapid plunge freezing process used to prepare samples lends itself to time-resolved studies, which researchers have pursued for in vitro samples for decades. Here, we focus on developing a freezing apparatus for time-resolved studies in situ. The device mixes cellular samples with solution-phase stimulants before spraying them directly onto an electron microscopy grid that is transiting into cryogenic liquid ethane. By varying the flow rates of cell and stimulant solutions within the device, we can control the reaction time from tens of milliseconds to over a second prior to freezing. In a proof-of-principle demonstration, the freezing method is applied to a model bacterium, Caulobacter crescentus, mixed with an acidic buffer. Through cryo-ET we resolved structural changes throughout the cell, including surface-layer protein dissolution, outer membrane deformation, and cytosolic rearrangement, all within 1.5 seconds of reaction time. This new approach, Time-Resolved cryo-ET (TR-cryo-ET), enhances the capabilities of cryo-ET by incorporating a sub-second temporal axis and enables the visualization of induced structural changes at the molecular, organelle, or cellular level.

59 BASIC BIOLOGICAL SCIENCES↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

On symmetry-resolved generalized entropies

Symmetry-resolved entanglement, capturing the refined structure of quantum entanglement in systems with global symmetries, has attracted a lot of attention recently. In this manuscript, introducing the notion of symmetry-resolved generalized entropies, we aim to develop a computational framework suitable for the study of excited state symmetry-resolved entanglement as well as the dynamical evolution of symmetry-resolved entanglement in symmetry-preserving out-of-equilibrium settings. We illustrate our framework using the example of (1+1)-d free massless compact boson theory, and benchmark our results using lattice computation in the XX chain. As a byproduct, our computational framework also provides access to the probability distribution of the symmetry charge contained within a subsystem and the corresponding full counting statistics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HIRS-AMTS satellite sounding system test - Theoretical and empirical vertical resolving power

The present investigation is concerned with the vertical resolving power of satellite-borne temperature sounding instruments. Information is presented on the capabilities of the High Resolution Infrared Radiation Sounder (HIRS) and a proposed sounding instrument called the Advanced Moisture and Temperature Sounder (AMTS). Two quite different methods for assessing the vertical resolving power of satellite sounders are discussed. The first is the theoretical method of Conrath (1972) which was patterned after the work of Backus and Gilbert (1968) The Backus-Gilbert-Conrath (BGC) approach includes a formalism for deriving a retrieval algorithm for optimizing the vertical resolving power. However, a retrieval algorithm constructed in the BGC optimal fashion is not necessarily optimal as far as actual temperature retrievals are concerned. Thus, an independent criterion for vertical resolving power is discussed. The criterion is based on actual retrievals of signal structure in the temperature field.

Thompson, O. E.↗

HIRS-AMTS satellite sounding system test - Vertical resolving power

The present investigation is concerned with the vertical resolving power of satellite borne temperature sounding instruments. Specifically, information is presented on the capabilities of the High Resolution Infra-red Radiation Sounder (HIRS) and a proposed sounding instrument called the Advanced Meteorological Temperature Sounder (AMTS). Two quite different methods for assessing the vertical resolving power of satellite sounders are discussed, taking into account the theoretical method of Conrath (1972), and an independent criterion for vertical resolving power which is based on actual retrievals of signal structure in the temperature field. Some discrepancies are found between theory and retrieval tests. The results indicate that the theoretical Backus and Gilbert spread function does not represent the shortest resolvable length scale for a retrieval system.

Thompson, O. E.↗

Candidate galaxies for study of the local velocity field and distance scale using Space Telescope. I - The most easily resolved. II - The more difficult cases. III - Galaxies in the Virgo cluster core

A subset of 1246 Shapley-Ames galaxies is presented which holds promise for some degree of useful resolution by the Space Telescope. The 95 candidate galaxies easiest to resolve are described and illustrated first. Many of these can be readily resolved into brightest stars from the ground with presently available telescopes at a few sites, while others might be resolved from the ground into at least the brightest blue supergiants. Then, 152 additional candidates are presented which can only be adequately studied with the Space Telescope. Finally, the most promising galaxies for studies of the resolved stellar content that occur in the central six degree core of the Virgo cluster are given. These are expected to be useful for any direct attack on the distance to the cluster itself.

Sandage, A.↗