Search NASA⌕ Search

SEARCH · Search NASA

Results for “respiratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Respiratory Protection Program medical clearance for respirator use

Background on occupational exposure to various inhalents is discussed including on-site hazard control measures, procedures, physiological effects, and interpretation of results for the medical clearance of employee for use of personal respiratory protection devices. The purpose of the Respiratory Protection Program at LeRC is outlined, and the specifics of the Medical Surveillance Program for Respiratory Protection at LeRC are discussed.

Source record↗

Three-dimensional ballistocardiography and respiratory motion in sustained microgravity

BACKGROUND: We measured the three-dimensional ballistocardiogram (BCG) in a free-floating subject in sustained microgravity during spaceflight to test the usefulness of such measurements for future non-invasive monitoring of cardiac function, and to examine the effects of respiratory movement on the BCG in three axes. METHODS: Acceleration was measured using a three-axis accelerometer fastened to the lumbar region of the subject while simultaneous recordings of ECG, and respiratory motion via impedance plethysmography were also made. Data were recorded during a 146-s period of inactivity on the part of the subject during which time there was no contact with the spacecraft. RESULTS: Total body motion due to respiratory activity was consistent with that calculated from the known action of the diaphragm and conservation of momentum. The accelerations due to cardiac activity, ensemble averaged over the R-R interval, were greatest along the head-to-foot axis. Maximum amplitude of the HIJK complex of the BCG generated by ventricular ejection was greatest in the head to foot axis (approximately 70 x 10(-3) m x s(-2)), but there were also substantial accelerations along the dorsoventral axis of up to 43 10(-3) m x s(-2), that are not measured interrestrial two-dimensional studies. The amplitude of the BCG was strongly affected by lung volume, with accelerations being reduced 50 to 70% between end-inspiration and end-expiration. CONCLUSIONS: These data suggest a greatly reduced transmission of the cardiac motion to the body at end-expiration (FRC) than at higher lung volumes. The BCG might be further developed as a non-invasive means of monitoring parameters such as stroke volume in microgravity.

Flight Experiment↗

Human Factors Assessment and Redesign of the ISS Respiratory Support Pack (RSP) Cue Card

The Respiratory Support Pack (RSP) is a medical pack onboard the International Space Station (ISS) that contains much of the necessary equipment for providing aid to a conscious or unconscious crewmember in respiratory distress. Inside the RSP lid pocket is a 5.5 by 11 inch paper procedural cue card, which is used by a Crew Medical Officer (CMO) to set up the equipment and deliver oxygen to a crewmember. In training, crewmembers expressed concerns about the readability and usability of the cue card; consequently, updating the cue card was prioritized as an activity to be completed. The Usability Testing and Analysis Facility at the Johnson Space Center (JSC) evaluated the original layout of the cue card, and proposed several new cue card designs based on human factors principles. The approach taken for the assessment was an iterative process. First, in order to completely understand the issues with the RSP cue card, crewmember post training comments regarding the RSP cue card were taken into consideration. Over the course of the iterative process, the procedural information was reorganized into a linear flow after the removal of irrelevant (non-emergency) content. Pictures, color coding, and borders were added to highlight key components in the RSP to aid in quickly identifying those components. There were minimal changes to the actual text content. Three studies were conducted using non-medically trained JSC personnel (total of 34 participants). Non-medically trained personnel participated in order to approximate a scenario of limited CMO exposure to the RSP equipment and training (which can occur six months prior to the mission). In each study, participants were asked to perform two respiratory distress scenarios using one of the cue card designs to simulate resuscitation (using a mannequin along with the hardware). Procedure completion time, errors, and subjective ratings were recorded. The last iteration of the cue card featured a schematic of the RSP, colors, borders, and simplification of the flow of information. The time to complete the RSP procedure was reduced by approximately three minutes with the new design. In an emergency situation, three minutes significantly increases the probability of saving a life. In addition, participants showed the highest preference for this design. The results of the studies and the new design were presented to a focus group of astronauts, flight surgeons, medical trainers, and procedures personnel. The final cue card was presented to a medical control board and approved for flight. The revised RSP cue card is currently onboard ISS.

Byrne, Vicky↗

Influence of respiratory motor neurone activity on human autonomic and haemodynamic rhythms

Although humans hold great advantages over other species as subjects for biomedical research, they also bring major disadvantages. One is that among the many rhythmic physiological signals that can be recorded, there is no sure way to know which individual change precedes another, or which change represents cause and which represents effect. In an attempt to deal with the inherent complexity of research conducted in intact human subjects, we developed and used a structural equation model to analyse responses of healthy young men to pharmacological changes of arterial pressure and graded inspiratory resistance, before and after vagomimetic atropine. Our model yielded a good fit of the experimental data, with a system weighted R2 of 0.77, and suggested that our treatments exerted both direct and indirect influences on the variables we measured. Thus, infusions of nitroprusside and phenylephrine exerted all of their direct effects by lowering and raising arterial pressure; the changes of R-R intervals, respiratory sinus arrhythmia and arterial pressure fluctuations that these drugs provoked, were indirect consequences of arterial pressure changes. The only direct effect of increased inspiratory resistance was augmentation of arterial pressure fluctuations. These results may provide a new way to disentangle and understand responses of intact human subjects to experimental forcings. The principal new insight we derived from our modelling is that respiratory gating of vagal-cardiac motor neurone firing is nearly maximal at usual levels of arterial pressure and inspiratory motor neurone activity.

Non-NASA Center↗

Transient cardio-respiratory responses to visually induced tilt illusions

Although the orthostatic cardio-respiratory response is primarily mediated by the baroreflex, studies have shown that vestibular cues also contribute in both humans and animals. We have demonstrated a visually mediated response to illusory tilt in some human subjects. Blood pressure, heart and respiration rate, and lung volume were monitored in 16 supine human subjects during two types of visual stimulation, and compared with responses to real passive whole body tilt from supine to head 80 degrees upright. Visual tilt stimuli consisted of either a static scene from an overhead mirror or constant velocity scene motion along different body axes generated by an ultra-wide dome projection system. Visual vertical cues were initially aligned with the longitudinal body axis. Subjective tilt and self-motion were reported verbally. Although significant changes in cardio-respiratory parameters to illusory tilts could not be demonstrated for the entire group, several subjects showed significant transient decreases in mean blood pressure resembling their initial response to passive head-up tilt. Changes in pulse pressure and a slight elevation in heart rate were noted. These transient responses are consistent with the hypothesis that visual-vestibular input contributes to the initial cardiovascular adjustment to a change in posture in humans. On average the static scene elicited perceived tilt without rotation. Dome scene pitch and yaw elicited perceived tilt and rotation, and dome roll motion elicited perceived rotation without tilt. A significant correlation between the magnitude of physiological and subjective reports could not be demonstrated.

NASA Center JSC↗

Respiratory system

The general anatomy and function of the human respiratory system is summarized. Breathing movements, control of breathing, lung volumes and capacities, mechanical relations, and factors relevant to respiratory support and equipment design are discussed.

Bartlett, R. G., Jr.↗

User's instructions for the Grodins' respiratory control model using the UNIVAC 1110 remote batch and demand processing

The transient and steady state response of the respiratory control system for variations in volumetric fractions of inspired gases and special system parameters are modeled. The program contains the capability to change workload. The program is based on Grodins' respiratory control model and can be envisioned as a feedback control system comprised of a plant (the controlled system) and the regulating component (controlling system). The controlled system is partitioned into 3 compartments corresponding to lungs, brain, and tissue with a fluid interconnecting patch representing the blood.

Source record↗

Self-Calibrating Respiratory-Flowmeter Combination

Dual flowmeters ensure accuracy over full range of human respiratory flow rates. System for measurement of respiratory flow employs two flowmeters; one compensates for deficiencies of other. Combination yields easily calibrated system accurate over wide range of gas flow.

Westenskow, Dwayne R.↗

MSFC Respiratory Protection Services

An overview of the Marshall Space Flight Center Respiratory Protection program is provided in this poster display. Respiratory protection personnel, building, facilities, equipment, customers, maintenance and operational activities, and Dynatech fit testing details are described and illustrated.

CoVan, James P.↗

Respiratory Distress

The University of Miami School of Medicine asked the Research Triangle Institute for assistance in improvising the negative pressure technique to relieve respiratory distress in infants. Marshall Space Flight Center and Johnson Space Center engineers adapted this idea to the lower-body negative-pressure system seals used during the Skylab missions. Some 20,000 babies succumb to respiratory distress in the U.S. each year, a condition in which lungs progressively lose their ability to oxygenate blood. Both positive and negative pressure techniques have been used - the first to force air into lungs, the second to keep infant's lungs expanded. Negative pressure around chest helps the baby expand his lungs and maintain proper volume of air. If doctors can keep the infant alive for four days, the missing substance in the lungs will usually form in sufficient quantity to permit normal breathing. The Skylab chamber and its leakproof seals were adapted for medical use.

Source record↗

Respiratory sinus arrhythmia: opposite effects on systolic and mean arterial pressure in supine humans

1. Are arterial blood pressure fluctuations buffered or reinforced by respiratory sinus arrhythmia (RSA)? There is still considerable debate about this simple question. Different results have been obtained, triggering a discussion as to whether or not the baroreflexes are responsible for RSA. We suspected that the measurements of different aspects of arterial pressure (mean arterial pressure (MAP) and systolic pressure (SP)) can explain the conflicting results. 2. Simultaneous recordings of beat-to-beat MAP, SP, left cardiac stroke volume (SV, pulsed ultrasound Doppler), heart rate (HR) and respiration (RE) were obtained in 10 healthy young adults during spontaneous respiration. In order to eliminate HR variations at respiratory frequency we used propranolol and atropine administration in the supine and tilted positions. Respiration-synchronous variation in the recorded variables was quantified by spectral analysis of the recordings of each of these variables, and the phase relations between them were determined by cross-spectral analysis. 3. MAP fluctuations increased after removing heart rate variations in both supine and tilted position, whereas SP fluctuations decreased in the supine position and increased in the head-up tilted position. 4. RSA buffers respiration-synchronous fluctuations in MAP in both positions. However, fluctuations in SP were reinforced by RSA in the supine and buffered in the tilted position.

Clinical Trial↗

Swimming kinematics and respiratory behaviour of Xenopus laevis larvae raised in altered gravity

We examined the respiratory behaviours and swimming kinematics of Xenopus laevis tadpoles hatched in microgravity (Space Shuttle), simulated microgravity (clinostat) and hypergravity (3 g centrifuge). All observations were made in the normal 1 g environment. Previous research has shown that X. laevis raised in microgravity exhibit abnormalities in their lungs and vestibular system upon return to 1 g. The tadpoles raised in true microgravity exhibited a significantly lower tailbeat frequency than onboard 1 g centrifuge controls on the day of landing (day0), but this behaviour normalized within 9 days. The two groups did not differ significantly in buccal pumping rates. Altered buoyancy in the space-flight microgravity tadpoles was indicated by an increased swimming angle on the day after landing (day1). Tadpoles raised in simulated microgravity differed to a greater extent in swimming behaviours from their 1 g controls. The tadpoles raised in hypergravity showed no substantive effects on the development of swimming or respiratory behaviours, except swimming angle. Together, these results show that microgravity has a transient effect on the development of locomotion in X. laevis tadpoles, most notably on swimming angle, indicative of stunted lung development. On the basis of the behaviours we studied, there is no indication of neuromuscular retardation in amphibians associated with embryogenesis in microgravity.

Flight Experiment↗

Heart rate and respiratory rhythm dynamics on ascent to high altitude

OBJECTIVE--To investigate the alterations in autonomic control of heart rate at high altitude and to test the hypothesis that hypoxaemic stress during exposure to high altitude induces non-linear, periodic heart rate oscillations, similar to those seen in heart failure and the sleep apnoea syndrome. SUBJECTS--11 healthy subjects aged 24-64. MAIN OUTCOME MEASURES--24 hour ambulatory electrocardiogram records obtained at baseline (1524 m) and at 4700 m. Simultaneous heart rate and respiratory dynamics during 2.5 hours of sleep by fast Fourier transform analysis of beat to beat heart rate and of an electrocardiographically derived respiration signal. RESULTS--All subjects had resting hypoxaemia at high altitude, with an average oxyhaemoglobin saturation of 81% (5%). There was no significant change in mean heart rate, but low frequency (0.01-0.05 Hz) spectral power was increased (P < 0.01) at high altitude. Time series analysis showed a complex range of non-linear sinus rhythm dynamics. Striking low frequency (0.04-0.06 Hz) heart rate oscillations were observed during sleep in eight subjects at high altitude. Analysis of the electrocardiographically derived respiration signal indicated that these heart rate oscillations correlated with low frequency respiratory oscillations. CONCLUSIONS--These data suggest (a) that increased low frequency power during high altitude exposure is not simply attributable to increased sympathetic modulation of heart rate, but relates to distinctive cardiopulmonary oscillations at approximately 0.05 Hz and (b) that the emergence of periodic heart rate oscillations at high altitude is consistent with an unstable cardiopulmonary control system that may develop on acute exposure to hypoxaemic stress.

Non-NASA Center↗

Human Factors Assessment of Respiratory Support Pack (RSP) Cue Card

The Respiratory Support Pack (RSP) is a medical pack onboard the International Space Station (ISS) that contains much of the necessary equipment for providing aid to a conscious or unconscious crewmember in respiratory distress. Inside the RSP lid pocket is a 5.5 by 11 inch paper cue card, which is used by a Crew Medical Officer as the procedure to set up the equipment and deliver oxygen to a crewmember. In training, crewmembers expressed concerns about the readability and usability of the cue card; consequently, updating the cue card was prioritized as an activity to be completed prior to Space Shuttle return-to-flight. The Usability Testing and Analysis Facility at the Johnson Space Center evaluated the current layout of the cue card, and proposed several new cue card designs based on human factors principals. A series of three studies were performed in order to experimentally compare performance with each of the cue card designs. Nonmedically trained personnel used either a redesigned RSP cue card, or the original card to simulate resuscitation (using a mannequin along with the hardware). Time to completion, errors and subjective ratings were recorded. The addition of pictures, colors, borders, and simplification of the flow of information (making minimal changes to the actual procedure content) elicited great benefits during testing. Time to complete RSP procedures was reduced by as much as three minutes with the final cue card design. Detailed results from these studies, as well as general guidelines for cue card design will be discussed.

Whitmore, Mihriban↗

Modeling Respiratory Toxicity of Authentic Lunar Dust

The lunar expeditions of the Apollo operations from the 60 s and early 70 s have generated awareness about lunar dust exposures and their implication towards future lunar explorations. Critical analyses on the reports from the Apollo crew members suggest that lunar dust is a mild respiratory and ocular irritant. Currently, NASA s space toxicology group is functioning with the Lunar Airborne Dust Toxicity Assessment Group (LADTAG) and the National Institute for Occupational Safety and Health (NIOSH) to investigate and examine toxic effects to the respiratory system of rats in order to establish permissible exposure levels (PELs) for human exposure to lunar dust. In collaboration with the space toxicology group, LADTAG and NIOSH the goal of the present research is to analyze dose-response curves from rat exposures seven and twenty-eight days after intrapharyngeal instillations, and model the response using BenchMark Dose Software (BMDS) from the Environmental Protection Agency (EPA). Via this analysis, the relative toxicities of three types of Apollo 14 lunar dust samples and two control dust samples, titanium dioxide (TiO2) and quartz will be determined. This will be executed for several toxicity endpoints such as cell counts and biochemical markers in bronchoaveolar lavage fluid (BALF) harvested from the rats.

Santana, Patricia A.↗

Benefits of Using Remote Sensing for Health Alerts and Chronic Respiratory Exposures

Respiratory diseases such as asthma can be triggered by environmental conditions that can be monitored using Earth observing data and environmental forecast models. Frequent dust storms in the southwestern United States, the annual cycle of juniper pollen events in the spring, and increased aerosol and ozone concentrations in summer, are health concerns shared by the community at large. Being able to forecast the occurrence of these events would help the health care community prepare for increased visits to emergency rooms, as well as allow public health officials to issue alerts to affected persons. This information also is important to epidemiologists for analyzing long-term trends and impacts of these events on the health and well-being of the community. Earth observing data collected by remote sensing platforms are important for improving the performance of models that can forecast these events, and in turn, improve products and information for decision-making by public health authorities. This presentation will discuss the benefits of using remote sensing data for forecasting environmental events that can adversely affect individuals with respiratory ailments. The presentations will include a brief discussion on relevant Earth observing data, the forecast models used, and societal benefits of the resulting products and information. Several NASA-funded projects will be highlighted as examples

Luvall, J. C.↗

Cardiac and Vascular Responses to Thigh Cuffs and Respiratory Maneuvers on Crewmembers of the International Space Station

The transition to microgravity eliminates the hydrostatic gradients in the vascular system. The resulting fluid redistribution commonly manifests as facial edema, engorgement of the external neck veins, and a decrease in leg diameter. This experiment examined the responses to modified Valsalva and Mueller maneuvers measured by cardiac and vascular ultrasound (ECHO) in a baseline steady state and during preload reduction introduced with thigh occlusion cuffs used as a counter-measure device (Braslet cuffs) measured by cardiac and vascular ultrasound examinations. Methods: Nine International Space Station crewmember subjects (Expeditions 16 - 20) were examined in 15 experiment sessions 101 +/- 46.days after launch (mean +/- SD; 33 - 185). Twenty Seven cardiac and vascular parameters were obtained with/without respiratory maneuvers before and after tightening of the Braslet cuffs. Results: Non-physicians performed diagnostic-quality cardiac and vascular ultrasound examinations using remote guidance. Three of 27 combinations of maneuvers and Braslet or Braslet alone were identified as being significant changed when compared to baseline. Eleven of 81 differences between combinations of Mueller, Valsalva or baseline were significant and related to cardiac preload reduction or increase in lower extremity venous volume. Conclusions: Acute application of Braslet occlusion cuffs causes lower extremity fluid sequestration and exerts commensurate measurable effects on cardiac performance in microgravity. Ultrasound techniques to measure the hemodynamic effects of thigh cuffs in combination with respiratory maneuvers may serve as an invaluable tool in determining the volume status of the cardiac patient at the 'microgravity bedside'.

Hamilton, Douglas↗