Search NASA⌕ Search

SEARCH · Search NASA

Results for “robust estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Synchrophasor Calculation Algorithm Based on Robust State Estimation

This paper proposes a novel robust state estimation based method for synchrophasor calculation. The proposed method upgrades traditional weighted least square based state estimation to a robust state estimation that uses iteratively re-weighted least square. As a result, it can better filter out measurement noise and reject bad data from synchrophasors. Numerical experiments are tested to compare the proposed method with existing IEEE C37.118 standard. Extensive results have demonstrated the great accuracy and dependability of proposed method when processing synchrophasor with measurement noises or bad data.

Li, Yunting↗

Reducing the cost of energy estimation in the variational quantum eigensolver algorithm with robust amplitude estimation

Quantum chemistry and materials is one of the most promising applications of quantum computing. Yet much work is still to be done in matching industry-relevant problems in these areas with quantum algorithms that can solve them. Most previous efforts have carried out resource estimations for quantum algorithms run on large-scale fault-tolerant architectures, which include the quantum phase estimation algorithm. In contrast, few have assessed the performance of near-term quantum algorithms, which include the variational quantum eigensolver (VQE) algorithm. Recently, a large-scale benchmark study [Gonthier et al. 2020] found evidence that the performance of the variational quantum eigensolver for a set of industry-relevant molecules may be too inefficient to be of practical use. This motivates the need for developing and assessing methods that improve the efficiency of VQE. In this work, we predict the runtime of the energy estimation subroutine of VQE when using robust amplitude estimation (RAE) to estimate Pauli expectation values. Under conservative assumptions, our resource estimation predicts that RAE can reduce the runtime over the standard estimation method in VQE by one to two orders of magnitude. Despite this improvement, we find that the runtimes are still too large to be practical. These findings motivate two complementary efforts towards quantum advantage: 1) the investigation of more efficient near-term methods for ground state energy estimation and 2) the development of problem instances that are of industrial value and classically challenging, but better suited to quantum computation.

Johnson, Peter D.↗

Evaluating Energy Differences on a Quantum Computer with Robust Phase Estimation

Here, we adapt the robust phase estimation algorithm to the evaluation of energy differences between two eigenstates using a quantum computer. This approach does not require controlled unitaries between auxiliary and system registers or even a single auxiliary qubit. As a proof of concept, we calculate the energies of the ground state and low-lying electronic excitations of a hydrogen molecule in a minimal basis on a cloud quantum computer. The denominative robustness of our approach is then quantified in terms of a high tolerance to coherent errors in the state preparation and measurement. Conceptually, we note that all quantum phase estimation algorithms ultimately evaluate eigenvalue differences.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Consistency testing for robust phase estimation

In this work, we present an extension to the robust phase estimation protocol, which can identify incorrect results that would otherwise lie outside the expected statistical range. Robust phase estimation is increasingly a method of choice for applications such as estimating the effective process parameters of noisy hardware, but its robustness is dependent on the noise satisfying certain threshold assumptions. We provide consistency checks that can indicate when those thresholds have been violated, which can be difficult or impossible to test directly. We test these consistency checks for several common noise models, and identify two possible checks with high accuracy in locating the point in a robust phase estimation run at which further estimates should not be trusted. One of these checks may be chosen based on resource availability, or they can be used together in order to provide additional verification.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust state estimation of feeding–blending systems in continuous pharmaceutical manufacturing

State estimation is a fundamental part of monitoring, control, and real-time optimization in continuous pharmaceutical manufacturing. For nonlinear dynamic systems with hard constraints, moving horizon estimation (MHE) can estimate the current state by solving a well-defined optimization problem where process complexities are explicitly considered as constraints. Traditional MHE techniques assume random measurement noise governed by some normal distributions. However, state estimates can be unreliable if noise is not normally distributed or measurements are contaminated with gross or systematic errors. In this paper, to improve the accuracy and robustness of state estimation, we incorporate robust estimators within the standard MHE skeleton, leading to an extended MHE framework. The proposed MHE approach is implemented on two pharmaceutical continuous feeding–blending system (FBS) configurations which include loss-in-weight (LIW) feeders and continuous blenders. Numerical results show that our MHE approach is robust to gross errors and can provide reliable state estimates when measurements are contaminated with outliers and drifts. Finally and moreover, the efficient solution of the MHE realized in this work, suggests feasible application of on-line state estimation on more complex continuous pharmaceutical processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How robust are estimates of key parameters in standard viral dynamic models?

Mathematical models of viral infection have been developed, fitted to data, and provide insight into disease pathogenesis for multiple agents that cause chronic infection, including HIV, hepatitis C, and B virus. However, for agents that cause acute infections or during the acute stage of agents that cause chronic infections, viral load data are often collected after symptoms develop, usually around or after the peak viral load. Consequently, we frequently lack data in the initial phase of viral growth, i.e., when pre-symptomatic transmission events occur. Missing data may make estimating the time of infection, the infectious period, and parameters in viral dynamic models, such as the cell infection rate, difficult. However, having extra information, such as the average time to peak viral load, may improve the robustness of the estimation. Here, we evaluated the robustness of estimates of key model parameters when viral load data prior to the viral load peak is missing, when we know the values of some parameters and/or the time from infection to peak viral load. Although estimates of the time of infection are sensitive to the quality and amount of available data, particularly pre-peak, other parameters important in understanding disease pathogenesis, such as the loss rate of infected cells, are less sensitive. Viral infectivity and the viral production rate are key parameters affecting the robustness of data fits. Fixing their values to literature values can help estimate the remaining model parameters when pre-peak data is missing or limited. We find a lack of data in the pre-peak growth phase underestimates the time to peak viral load by several days, leading to a shorter predicted growth phase. On the other hand, knowing the time of infection (e.g., from epidemiological data) and fixing it results in good estimates of dynamical parameters even in the absence of early data. While we provide ways to approximate model parameters in the absence of early viral load data, our results also suggest that these data, when available, are needed to estimate model parameters more precisely.

59 BASIC BIOLOGICAL SCIENCES↗

A COMPREHENSIVE ANALYSIS OF UNCERTAINTIES AFFECTING THE STELLAR MASS-HALO MASS RELATION FOR 0 < z < 4

We conduct a comprehensive analysis of the relationship between central galaxies and their host dark matter halos, as characterized by the stellar mass-halo mass (SM-HM) relation, with rigorous consideration of uncertainties. Our analysis focuses on results from the abundance matching technique, which assumes that every dark matter halo or subhalo above a specific mass threshold hosts one galaxy. We provide a robust estimate of the SM-HM relation for 0 < z < 1 and discuss the quantitative effects of uncertainties in observed galaxy stellar mass functions (including stellar mass estimates and counting uncertainties), halo mass functions (including cosmology and uncertainties from substructure), and the abundance matching technique used to link galaxies to halos (including scatter in this connection). Our analysis results in a robust estimate of the SM-HM relation and its evolution from z = 0 to z = 4. The shape and the evolution are well constrained for z < 1. The largest uncertainties at these redshifts are due to stellar mass estimates (0.25 dex uncertainty in normalization); however, failure to account for scatter in stellar masses at fixed halo mass can lead to errors of similar magnitude in the SM-HM relation for central galaxies in massive halos. We also investigate the SM-HM relation to z = 4, although the shape of the relation at higher redshifts remains fairly unconstrained when uncertainties are taken into account. We find that the integrated star formation at a given halo mass peaks at 10%-20% of available baryons for all redshifts from 0 to 4. This peak occurs at a halo mass of 7 x 10{sup 11} M{sub sun} at z = 0 and this mass increases by a factor of 5 to z = 4. At lower and higher masses, star formation is substantially less efficient, with stellar mass scaling as M{sub *} {approx} M {sup 2.3}{sub h} at low masses and M{sub *} {approx} M {sup 0.29}{sub h} at high masses. The typical stellar mass for halos with mass less than 10{sup 12} M{sub sun} has increased by 0.3-0.45 dex for halos since z {approx} 1. These results will provide a powerful tool to inform galaxy evolution models.

79 ASTRONOMY AND ASTROPHYSICS↗

Hybrid approach for estimating dynamic states of synchronous generators

Accurate and robust estimation of dynamic states is essential for monitoring and controlling a power grid. To achieve higher accuracy and robustness, this paper proposes a hybrid estimation approach to estimate the dynamic states of synchronous generators using multiple models, classified into a set of local models and a wide-area model. The proposed estimation approach, first, estimates dynamic states using the extended Kalman filter (EKF) based on a local model and a wide-area model. Then, at each time step, probability indexes, which quantify the likelihood of both local and wide-area models, are determined using hypothesis testing based on measurements innovations. Finally, using the weighted fix approach, the states estimated from the local and wide-area models are combined based on their probability indexes. Simulation studies using the two-area four-machine system shows that the proposed approach can improve estimation accuracy and increase robustness against model errors.

Akhlaghi, Shahrokh↗

Robust Period Estimation Using Mutual Information for Multiband Light Curves in the Synoptic Survey Era

The Large Synoptic Survey Telescope (LSST) will produce an unprecedented amount of light curves using six optical bands. Robust and efficient methods that can aggregate data from multidimensional sparsely sampled time-series are needed. Here, we present a new method for light curve period estimation based on quadratic mutual information (QMI). The presented method does not assume a particular model for the light curve nor its underlying probability density and it is robust to non-Gaussian noise and outliers. By combining the QMI from several bands the true period can be estimated even when no single-band QMI yields the period. Period recovery performance as a function of average magnitude and sample size is measured using 30,000 synthetic multiband light curves of RR Lyrae and Cepheid variables generated by the LSST Operations and Catalog simulators. The results show that aggregating information from several bands is highly beneficial in LSST sparsely sampled time-series, obtaining an absolute increase in period recovery rate up to 50%. We also show that the QMI is more robust to noise and light curve length (sample size) than the multiband generalizations of the Lomb–Scargle and AoV periodograms, recovering the true period in 10%–30% more cases than its competitors. A python package with efficient Cython implementations of the QMI and other methods is provided.

79 ASTRONOMY AND ASTROPHYSICS↗

RADIO OBSERVATIONS OF HD 80606 NEAR PLANETARY PERIASTRON

This paper reports Very Large Array observations at 325 and 1425 MHz ({lambda}90 cm and {lambda}20 cm) during and near the periastron passage of HD 80606b on HJD 2454424.86 (2007 November 20). We obtain flux density limits (3{sigma}) of 1.7 mJy and 48 {mu}Jy at 325 and 1425 MHz, respectively, equivalent to planetary luminosity limits of 2.3 x 10{sup 24} erg s{sup -1} and 2.7 x 10{sup 23} erg s{sup -1}. Unfortunately, these are several orders of magnitude above the nominal Jovian value (at 40 MHz) of 2 x 10{sup 18} erg s{sup -1}. The motivation for these observations was that the planetary magnetospheric emission is driven by a stellar wind-planetary magnetosphere interaction so that the planetary luminosity would be elevated near periastron. We estimate that, near periastron, HD 80606b might be as much as 3000 times more luminous than Jupiter. Recent transit observations of HD 80606b provide reasonably stringent constraints on the planetary mass and radius, and, because of the planet's highly eccentric orbit, its rotation period is likely to be 'pseudo-synchronized' to its orbital period, allowing a robust estimate of the former. Consequently, we are able to make relatively robust estimates of the emission frequency of the planetary magnetospheric emission and find it to be around 60-90 MHz. While this is too low for our reported observations, we compare HD 80606b to other high-eccentricity systems and assess the detection possibilities for both near-term and more distant future systems. Of the known high-eccentricity planets, only HD 80606b is likely to be detectable, as the others (HD 20782B and HD 4113) are both lower mass and longer rotational periods, which imply weaker magnetic field strengths. We find that both the forthcoming 'EVLA low band' system, which will operate as low as 65 MHz, and the Low Frequency Array may be able to improve upon our planetary luminosity limits for HD 80606b, and do so at a more optimum frequency. If the low-frequency component of the Square Kilometre Array (SKA-lo) and a future lunar radio array are able to approach their thermal noise limits, they should be able to detect an HD 80606b-like planet, unless the amount by which the planet's luminosity increases is substantially less than the factor of 3000 that we estimate; for the SKA-lo, which is to be located in the southern hemisphere, future planetary surveys will have to find southern hemisphere equivalents of HD 80606b.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of scat detection methods for a social ungulate, the wild pig, and experimental evaluation of factors affecting detection of scat

Collection of scat samples is common in wildlife research, particularly for genetic capture-mark-recapture applications. Due to high degradation rates of genetic material in scat, large numbers of samples must be collected to generate robust estimates. Optimization of sampling approaches to account for taxa-specific patterns of scat deposition is, therefore, necessary to ensure sufficient sample collection. While scat collection methods have been widely studied in carnivores, research to maximize scat collection and noninvasive sampling efficiency for social ungulates is lacking. Further, environmental factors or scat morphology may influence detection of scat by observers. We contrasted performance of novel radial search protocols with existing adaptive cluster sampling protocols to quantify differences in observed amounts of wild pig ( Sus scrofa ) scat. We also evaluated the effects of environmental (percentage of vegetative ground cover and occurrence of rain immediately prior to sampling) and scat characteristics (fecal pellet size and number) on the detectability of scat by observers. We found that 15- and 20-m radial search protocols resulted in greater numbers of scats encountered than the previously used adaptive cluster sampling approach across habitat types, and that fecal pellet size, number of fecal pellets, percent vegetative ground cover, and recent rain events were significant predictors of scat detection. Our results suggest that use of a fixed-width radial search protocol may increase the number of scats detected for wild pigs, or other social ungulates, allowing more robust estimation of population metrics using noninvasive genetic sampling methods. Further, as fecal pellet size affected scat detection, juvenile or smaller-sized animals may be less detectable than adult or large animals, which could introduce bias into abundance estimates. In conclusion, knowledge of relationships between environmental variables and scat detection may allow researchers to optimize sampling protocols to maximize utility of noninvasive sampling for wild pigs and other social ungulates.

59 BASIC BIOLOGICAL SCIENCES↗

A robust geometry estimation method for spiral, sequential and circular cone-beam micro-CT

Purpose: The authors propose a novel method for misalignment estimation of micro-CT scanners using an adaptive genetic algorithm. Methods: The proposed algorithm is able to estimate the rotational geometry, the direction vector of table movement and the displacement between different imaging threads of a dual source or even multisource scanner. The calibration procedure does not rely on dedicated calibration phantoms and a sequence scan of a single metal bead is sufficient to geometrically calibrate the whole imaging system for spiral, sequential, and circular scan protocols. Dual source spiral and sequential scan protocols in micro-computed tomography result in projection data that-besides the source and detector positions and orientations-also require a precise knowledge of the table direction vector to be reconstructed properly. If those geometric parameters are not known accurately severe artifacts and a loss in spatial resolution appear in the reconstructed images as long as no geometry calibration is performed. The table direction vector is further required to ensure that consecutive volumes of a sequence scan can be stitched together and to allow the reconstruction of spiral data at all. Results: The algorithm's performance is evaluated using simulations of a micro-CT system with known geometry and misalignment. To assess the quality of the algorithm in a real world scenario the calibration of a micro-CT scanner is performed and several reconstructions with and without geometry estimation are presented. Conclusions: The results indicate that the algorithm successfully estimates all geometry parameters, misalignment artifacts in the reconstructed volumes vanish, and the spatial resolution is increased as can be shown by the evaluation of modulation transfer function measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗