Search NASA⌕ Search

SEARCH · Search NASA

Results for “room-temperature radiation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

27 records · Page 2

Synthesis of CdZnTeSe single crystals for room temperature radiation detector fabrication: mitigation of hole trapping effects using a convolutional neural network

In this article, we report the growth of Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 (CZTS) wide bandgap semiconductor single crystals for room temperature gamma-ray detection using a modified vertical Bridgman method. Charge transport properties measured in the radiation detectors, fabricated from the grown CZTS crystals, indicated signs of hole trapping. Hole traps inhibit high-resolution radiation detection especially for energetic gamma rays. Machine learning (ML) applications are gaining tremendous mpetus in improving device and sensor performance by compensating for limi tations arising from such intrinsic material properties. In this article, we describe a deep convolutional neural network (CNN) that has demonstrated remarkable efficiency in identifying the energy of a gamma photon detected by a CZTS detector. The CNN has been trained using simulated data that resemble output pulses from actual CZTS detectors when exposed to 662-keV gamma photons. The device properties required for the simulation have been derived from radiation detection measurements on a real Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 detector fabricated in our laboratory. The CNN has been trained with detector pulses arising through photoelectric (PE) and Compton scattering (CS) separately. The percentage error in predicting the detected energies, within an extremely small duration of 0.28 ms, was found to be lower than 0.1% for gamma energies above 50 keV and for training datasets con taining PE and CS events separately. The CNN was also validated for a mixed PE and CS dataset to obtain a prediction error of 1%. Additionally, the effect of detector resolution on the efficiency of the CNN was also explored.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-low-noise, high-impedance preamp for cryogenic detectors

A relatively simple room-temperature preamp design that satisfies both the low-noise and wideband requirements for the InSb Putley-mode detector and which is based on a common-drain JFET input, is presented. The design has an input capacitance of 28 pf which is much less than comparably noisy common-source amplifiers. It can be used for preamplification of 0.1 to 10 MHz signals from liquid-helium-cooled radiation detectors.

Brown, E. R.↗

Micromachined Electron-Tunneling Infrared Detectors

Pneumatic/thermal infrared detectors based partly on Golay-cell concept, but smaller and less fragile. Include containers filled with air or other gas trapped behind diaphragms. Infrared radiation heats sensors, causing gas to expand. Resulting deflections of diaphragms measured by displacement sensors based on principle of electron-tunneling transducers of scanning tunneling microscopes. Exceed sensitivity of all other miniature, uncooled infrared sensors presently available. Expected to include low consumption of power, broadband sensitivity, room-temperature operation, and invulnerability to ionizing radiation.

Kenny, Thomas W.↗

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

NASA Tech Briefs, June 2009

Topics covered include: Device for Measuring Low Flow Speed in a Duct, Measuring Thermal Conductivity of a Small Insulation Sample, Alignment Jig for the Precise Measurement of THz Radiation, Autoignition Chamber for Remote Testing of Pyrotechnic Devices, Microwave Power Combiners for Signals of Arbitrary Amplitude, Synthetic Foveal Imaging Technology, Airborne Antenna System for Minimum-Cycle-Slip GPS Reception, Improved Starting Materials for Back-Illuminated Imagers, Multi-Modulator for Bandwidth-Efficient Communication, Some Improvements in Utilization of Flash Memory Devices, GPS/MEMS IMU/Microprocessor Board for Navigation, T/R Multi-Chip MMIC Modules for 150 GHz, Pneumatic Haptic Interfaces, Device Acquires and Retains Rock or Ice Samples, Cryogenic Feedthrough Test Rig, Improved Assembly for Gas Shielding During Welding or Brazing, Two-Step Plasma Process for Cleaning Indium Bonding Bumps, Tool for Crimping Flexible Circuit Leads, Yb14MnSb11 as a High-Efficiency Thermoelectric Material, Polyimide-Foam/Aerogel Composites for Thermal Insulation, Converting CSV Files to RKSML Files, Service Management Database for DSN Equipment, Chemochromic Hydrogen Leak Detectors, Compatibility of Segments of Thermoelectric Generators, Complementary Barrier Infrared Detector, JPL Greenland Moulin Exploration Probe, Ultra-Lightweight Self-Deployable Nanocomposite Structure for Habitat Applications, and Room-Temperature Ionic Liquids for Electrochemical Capacitors.

Source record↗

Review of Direct Neutron Conversion and Detection Processes

Commercial and laboratory neutron detection systems use indirect neutron response of materials like pressurized helium-3 (via nuclear reaction 3He(n, p)3H) to measure and count neutrons emanating from a source. Recently a host of semiconductors, especially a ternary semiconductor of lithium indium diselenide (6LiInSe2) and a quaternary alloy of enriched lithium-6, indium, phosphorous, and selenium (6LiInP2Se6), have shown promising neutron counting possibilities by directly converting neutrons into charge-carrying elements within the body of the semiconductor. These semiconductors have high thermal neutron capture cross sections, suitable energy bandgaps (~2.0 electron volts) for room-temperature operations, and a favorable electronic band structure for efficient electron charge transport. The article examines the semiconductor properties of these compounds in terms of their neutron counting capabilities and possible ways to extract neutron energy information from them. Lithium-6 and boron-10 (with thermal neutron absorption cross sections of 938 ± 6 and 3855 ± 26 barns, respectively) produce charged particles to be measured via indirect neutron interactions. The efficiency of indirect conversion neutron detectors is limited because of the inefficiencies in conversion mechanism. In case of direct conversion, the neutrons create charged particles in a single material for neutron capture and charge collection, increasing detection efficiency. Unlike 3He proportional counters, which provide no neutron energy information, the semiconductors can be used as neutron energy spectrometer. Fully resolved neutron energy by 6LiInP2Se6 from a plutonium-beryllium source has been reported in the literature. We will discuss the influence of these multilayered semiconductors’ crystallographic structures and growth techniques on neutron energy determination.

61 RADIATION PROTECTION AND DOSIMETRY↗

Determination of electron-hole pair creation energy in Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 quaternary semiconductor for room-temperature gamma-ray detection

We report the first-time measurement of the electron-hole pair (ehp) creation energy (W ehp ) in novel Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 (CZTS) quaternary semiconductor. CZTS in single crystalline form is poised to be the future of large-volume room-temperature gamma-ray detectors due to its excellent compositional homogeneity with highly reduced defects, high-Z (atomic number) constituents, wide bandgap (1.6 eV), and superior charge transport properties. Despite a great deal of study of the material and device properties since its inception, the W ehp in CZTS has not been measured experimentally. Accurate determination of W ehp is essential for calibration of the spectrometer and other theoretical calculations. In this study we have used an absolute calibration approach, which is based on an iterative approach that yields the Wehp as the best-fit parameter. Using a 241 Am alpha emitting radioisotope and a planar CZTS detector, the Wehp in CZTS was calculated to be 4.47 eV. The obtained value has been validated by accurately predicting the peak energy for gamma rays emitted by a 137 Cs source and read by a CZTS detector with different dimensions. The dependences of the calculated W ehp value on the detector dimensions, type of interaction, and effect of charge trapping are also discussed.

42 ENGINEERING↗

Raman Wavelength Conversion in Ionic Liquids

Here, we explore the use of room-temperature ionic liquids (ILs) as Raman wavelength converters. ILs provide an engineerable framework to design suitable liquids for wavelength conversion over a broad spectral range, through careful selection of the molecular structures of the IL anions and cations so that specific characteristics can be obtained, such as a desirable Raman shift, low Brillouin scattering, and good optical transmission in the pump and Stokes wavelengths. Applying such criteria, we demonstrate that 1-ethyl-3-methylimidazolium dicyanamide (EMIM DCA) is an effective medium for conversion of 532-nm pulses from a Q-switched Nd :YAG laser to 603 nm. This corresponds to an approximate 2200 cm –1 shift, which can be used to generate mid-infrared radiation through subsequent difference frequency generation for optical pumping of CO 2 lasers. Threefold-higher Raman conversion efficiency is obtained in EMIM DCA compared with water under identical conditions in a proof-of-principle single-pass conversion setup, resulting in an efficient generation of multimillijoule, <6 ns duration, high-quality orange laser pulses in a wavelength region that is difficult to access at high energies. Consequently, we examine ILs representing two other classes of Raman-active functional groups and obtain conversion up to the fifth-order Stokes shift and first anti-Stokes shift. Through the tunable selection of their components and their useful dynamical properties, ILs provide a platform for efficient, simple, and alignment-tolerant high-energy Raman shifting with numerous industrial and technological applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Holographic particle detection

The feasibility was studied of developing a novel particle track detector based on the detection of 1p-1s emission radiation from electron bubbles in liquid helium. The principles, design, construction, and initial testing of the detection system have been described in previous reports. The main obstacle encountered was the construction of the liquid-helium tight infrared windows. Despite numerous efforts in testing and redesigning the windows, the problem of window leakage at low temperature persisted. Due to limited time and resources, attention was switched to investigating the possibility of using room-temperature liquid as the detection medium. A possible mechanism was the detection of de-excitation radiation emitted from localized electrons in common liquids where electrons exhibit low mobilities, as suggested in the previous report. The purity of the liquid is critical in this method as the dissolved impurities (such as oxygen), even in trace amounts, will act as scavengers of electrons. Another mechanism is discussed whereby the formation of the superoxide ions by electron scavenging behavior of dissolved oxygen is exploited to detect the track of ionizing particles. An experiment to measure the ionization current produced in a liquid by a pulsed X-ray beam in order to study propertiies of the ions is also reported.

Bowen, Theodore↗