Search NASA⌕ Search

SEARCH · Search NASA

Results for “rounding error analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

SU-C-BRD-02: A Team Focused Clinical Implementation and Failure Mode and Effects Analysis of HDR Skin Brachytherapy Using Valencia and Leipzig Surface Applicators

Purpose: and Leipzig applicators (VLAs) are single-channel brachytherapy surface applicators used to treat skin lesions up to 2cm diameter. Source dwell times can be calculated and entered manually after clinical set-up or ultrasound. This procedure differs dramatically from CT-based planning; the novelty and unfamiliarity could lead to severe errors. To build layers of safety and ensure quality, a multidisciplinary team created a protocol and applied Failure Modes and Effects Analysis (FMEA) to the clinical procedure for HDR VLA skin treatments. Methods: team including physicists, physicians, nurses, therapists, residents, and administration developed a clinical procedure for VLA treatment. The procedure was evaluated using FMEA. Failure modes were identified and scored by severity, occurrence, and detection. The clinical procedure was revised to address high-scoring process nodes. Results: Several key components were added to the clinical procedure to minimize risk probability numbers (RPN): -Treatments are reviewed at weekly QA rounds, where physicians discuss diagnosis, prescription, applicator selection, and set-up. Peer review reduces the likelihood of an inappropriate treatment regime. -A template for HDR skin treatments was established in the clinical EMR system to standardize treatment instructions. This reduces the chances of miscommunication between the physician and planning physicist, and increases the detectability of an error during the physics second check. -A screen check was implemented during the second check to increase detectability of an error. -To reduce error probability, the treatment plan worksheet was designed to display plan parameters in a format visually similar to the treatment console display. This facilitates data entry and verification. -VLAs are color-coded and labeled to match the EMR prescriptions, which simplifies in-room selection and verification. Conclusion: Multidisciplinary planning and FMEA increased delectability and reduced error probability during VLA HDR Brachytherapy. This clinical model may be useful to institutions implementing similar procedures.

60 APPLIED LIFE SCIENCES↗

Error Analysis of ZFP Compression for Floating-Point Data

Compression of floating-point data will play an important role in high-performance computing as data bandwidth and storage become dominant costs. Lossy compression of floating-point data is powerful, but theoretical results are needed to bound its errors when used to store look-up tables, simulation results, or even the solution state during the computation. In this paper, we analyze the round-off error introduced by ZFP, a lossy compression algorithm. Here, the stopping criteria for ZFP depends on the compression mode specified by the user: fixed rate, fixed accuracy, or fixed precision [P. Lindstrom, ZFP 0.5.3 Documentation, 2018]. While most of our discussion is focused on the fixed precision mode of ZFP, we establish a bound on the error introduced by all three compression modes. In order to tightly capture the error, first we introduce a vector space that allows us to work with binary representations of components. Under this vector space, we define operators that implement each step of the ZFP compression and decompression to establish a bound on the error caused by ZFP. To conclude, numerical tests are provided to demonstrate the accuracy of the established bounds.

97 MATHEMATICS AND COMPUTING↗

Search for Muon Neutrino Disappearance in the Booster Neutrino Beam of Fermilab; Busqueda de Desaparicion de Neutrinos del Muon en el Haz de Neutrinos del Booster de Fermilab

In this work we carried out the disappearance analysis of muon neutrinos produced in the Fermilab Booster Neutrino Beam, using the data released to the public by the collaborations of the MiniBooNE and SciBooNE experiments. The calculations were made with programs in C and C++, implementing the ROOT libraries. From the analysis, using both the classical Pearson method and the Feldman and Cousins frequentist corrections, we obtained the 90\% C.L. limit for the oscillation parameters sin 2 2θ and Δm 2 in the region 0.1 ≤ Δm 2 ≤ 10 eV 2 using a two neutrino model. The result presented in this work is consistent with the official one, with small deviations ascribed to round-off errors in the format of the used data, as well as statistical fluctuations in the generation of fake experiments used in the Feldman and Cousins method. As the official one, our result is consistent with the null oscillation hypothesis. This work was carried out independently to the MiniBooNE and SciBooNE collaborations and its results are not official.

43 PARTICLE ACCELERATORS↗

Lamost observations in the Kepler field. Analysis of the stellar parameters measured with LASP based on low-resolution spectra

All 14 subfields of the Kepler field were observed at least once with the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (lamost, Xinglong Observatory, China) during the 2012–2014 observation seasons. There are 88,628 reduced spectra with a signal-to-noise ratio in the g band (S/N{sub g}) ≥ 6 after the first round (2012–2014) of observations of the lamost– Kepler project (LK-project). By adopting the upgraded version of the lamost Stellar Parameter pipeline (lasp), we have determined the atmospheric parameters (T{sub eff}, logg, and [Fe/H]) and heliocentric radial velocity v {sub rad} for 51,406 stars with 61,226 spectra. Compared with the atmospheric parameters derived from both high-resolution spectroscopy and asteroseismology for common stars in Huber et al., an external calibration of lasp atmospheric parameters was made, leading to the determination of the external errors for giants and dwarfs. Multiple spectroscopic observations of the same objects in the LK-project were used to estimate the internal uncertainties of the atmospheric parameters as a function of S/N{sub g} with the unbiased estimation method. The lasp atmospheric parameters were calibrated based on both the external and internal uncertainties for the giants and dwarfs. A general statistical analysis of the stellar parameters leads to the discovery of 106 candidate metal-poor stars, 9 candidate very metal-poor stars, and 18 candidate high-velocity stars. Fitting formulae were obtained segmentally for both the calibrated atmospheric parameters of the LK-project and the Kepler Input Catalog (KIC) parameters with common stars. The calibrated atmospheric parameters and radial velocities of the LK-project will be useful for studying stars in the Kepler field.

79 ASTRONOMY AND ASTROPHYSICS↗

Technical Development for S-CO 2 Advanced Energy Conversion

This report is divided into four parts. First part of the report describes the methods used to measure and model the flow of supercritical carbon dioxide (S-CO 2 ) through annuli and straight-through labyrinth seals. The effects of shaft eccentricity in small diameter annuli were observed for length-to-hydraulic diameter (L/D) ratios of 6, 12, 143, and 235. Flow rates through tooth-cavity labyrinth seals were measured for inlet pressures of 7.7, 10, and 11 MPa with corresponding inlet densities of 325, 475, and 630 kg/m 3 . Various leakage models were compared to this result to describe their applicability in supercritical carbon dioxide applications. Flow rate measurements were made varying tooth number for labyrinth seals of same total length. Second part of the report describes the computational study performed to understand the leakage through the labyrinth seals using Open source CFD package OpenFOAM. Fluid Property Interpolation Tables (FIT) program was implemented in OpenFOAM to accurately model the properties of CO2 required to solve the governing equations. To predict the flow behavior in the two phase dome Homogeneous Equilibrium Model (HEM) is assumed to be valid. Experimental results for plain orifice (L/D ~ 5) were used to show the capabilities of the FIT model implemented in OpenFOAM. Error analysis indicated that OpenFOAM is capable of predicting experimental data within ±10% error with the majority of data close to ±5% error. Following the validation of computational model, effects of geometrical parameters and operating conditions are isolated from each other and a parametric study was performed in two parts to understand their effects on leakage flow. Third part of the report provides the details of the constructed heat exchanger test facility and presents the experimental results obtained to investigate the effects of buoyancy on heat transfer characteristics of Supercritical carbon dioxide in heating mode. Turbulent flows with Reynolds numbers up to 60,000, at operating pressures of 7.5, 8.1, and 10.2 MPa were tested in a round tube. Local heat transfer coefficients were obtained from measured wall temperatures over a large set of experimental parameters that varied inlet temperature from 20 °C to 55 °C,mass flux from 150 to 350 kg/m 2 s, and a maximum heat flux of 65 KW/m 2 . Horizontal, upward and downward flows were tested to investigate the unusual heat-transfer characteristics to the effect of buoyancy and flow acceleration caused by large variation in density. Final part of this report presents the simplified analysis performed to investigate the possibility of using wet cooling tower option to reject heat from the supercritical carbon dioxide Brayton cycle power convertor for AFR-100 and ABR-1000 plants. A code was developed to estimate the tower dimensions, power and water consumption, and to perform economic analysis. The code developed was verified by comparing the calculations to a vendor quote. The effect of ambient air and water conditions on the sizing and construction of the cooling tower as well as the cooler is studied. Finally, a cost-based optimization technique is used to estimate the optimum water conditions which will improve the plant economics.

36 MATERIALS SCIENCE↗

Round Robin Measurements of Molten Salt Properties for LiF-NaF-KF (FLiNaK) and NaCl-KCl Mixtures

The development, operation, and regulation of nuclear reactors that utilize molten salts as fuel or as heat transfer media require knowledge of the thermal properties of the salt systems and quantification of the corresponding uncertainties. Knowledge of molten salt properties is also necessary for applications in material synthesis, processing, separations, solar thermal power generation, and energy storage. A round robin was conducted with national laboratory and university participants from twenty-one laboratories in five countries to compare property measurements, to better understand uncertainties, and to identify possible best practices. Two salt mixtures, each from a common batch, were distributed to participants for evaluation: equimolar NaCl-KCl and 45.0LiF-13.7NaF-41.3KF mol % (FLiNaK). Measurements were performed to determine the major constituent composition, oxygen content, density, thermal expansivity, melting point, and thermal conductivity. Error analysis was performed on each measurement for uncertainty quantification for each type of property that was explored. Finally, the resulting discussion of the methodologies used in this work is meant to lay the groundwork for the development of standard methods and reference materials for future high-temperature property measurements on halide melts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ensuring statistical reproducibility of ocean model simulations in the age of hybrid computing

Novel high performance computing systems that feature hybrid architectures require large scale code refactoring to unravel underlying exploitable parallelism. Such redesign can often be accompanied with machine-precision changes as the order of computation cannot always be maintained. For chaotic systems like climate models, these round-off level differences can grow rapidly. Systematic errors may also manifest initially as machine-precision differences. Isolating genuine round off level differences from such errors remains a challenge. Here, we apply two-sample equality of distribution tests to evaluate statistical reproducibility of the ocean model component of US Department of Energy's Energy Exascale Earth System Model (E3SM). A 2-year control simulation ensemble is compared to a modified ensemble as a test case - after a known non-bit-for-bit change in a model component is introduced - to evaluate the null hypothesis that the two ensembles are statistically indistinguishable. To quantify the false negative rates of these tests, we conduct a formal power analysis using a targeted suite of short simulation ensembles. The ensemble suite contains several perturbed ensembles, each with a progressively different climate than the baseline ensemble - obtained by perturbing the magnitude of a single model tuning parameter, the Gent and McWilliams κ, in a controlled manner. The null hypothesis is evaluated for each of perturbed ensembles using these tests. The power analysis informs on the detection limits of the tests for given ensemble size allowing model developers to evaluate the impact of an introduced non-bit-for-bit change to the model.

Mahajan, Salil↗

RICH: OPEN-SOURCE HYDRODYNAMIC SIMULATION ON A MOVING VORONOI MESH

We present here RICH, a state-of-the-art two-dimensional hydrodynamic code based on Godunov’s method, on an unstructured moving mesh (the acronym stands for Racah Institute Computational Hydrodynamics). This code is largely based on the code AREPO. It differs from AREPO in the interpolation and time-advancement schemeS as well as a novel parallelization scheme based on Voronoi tessellation. Using our code, we study the pros and cons of a moving mesh (in comparison to a static mesh). We also compare its accuracy to other codes. Specifically, we show that our implementation of external sources and time-advancement scheme is more accurate and robust than is AREPO when the mesh is allowed to move. We performed a parameter study of the cell rounding mechanism (Lloyd iterations) and its effects. We find that in most cases a moving mesh gives better results than a static mesh, but it is not universally true. In the case where matter moves in one way and a sound wave is traveling in the other way (such that relative to the grid the wave is not moving) a static mesh gives better results than a moving mesh. We perform an analytic analysis for finite difference schemes that reveals that a Lagrangian simulation is better than a Eulerian simulation in the case of a highly supersonic flow. Moreover, we show that Voronoi-based moving mesh schemes suffer from an error, which is resolution independent, due to inconsistencies between the flux calculation and the change in the area of a cell. Our code is publicly available as open source and designed in an object-oriented, user-friendly way that facilitates incorporation of new algorithms and physical processes.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of the Planetary Boundary Layer Height From ERA5 Reanalysis With MOSAiC Observations Over the Arctic Ocean

The planetary boundary layer height (PBLH) is a crucial indicator reflecting the region of the atmosphere characterized by continuous turbulence. Here, we use radiosonde and surface meteorological observations (4–7 times per day, year-round measurements) during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition to derive the PBLH (PBLH MOSAiC ), and further evaluate the PBLH from the ERA5 reanalysis (PBLH ERA5 ). Comparisons between PBLH MOSAiC and PBLH ERA5 from different perspectives reveal that: (a) The overestimation of PBLH ERA5 when the sea ice concentration is >90% is significant with the centered root mean squared error reaching up to 201 m; (b) The difference between the two products is notably pronounced in cold seasons, while it is comparatively diminished in warm seasons; (c) In neutral boundary layers, differences in PBLH ERA5 are larger compared with stable and convective boundary layers. In addition, the analysis of error sources indicates that the bias of PBLH ERA5 is sensitive to the bias of vertical thermal structure and wind speed profiles in ERA5 data sets in all conditions. Finally, we find a Random Forest model effectively reduces the bias of PBLH ERA5 with the index of agreement reaching up to 0.71 in the test data set, while a multiple linear regression demonstrates comparable performance to the Random Forest model.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Hanford LAW Phase 3 Glasses

This report provides analyses of glass compositions, wash solution compositions, and Product Consistency Test (PCT) leachate compositions for a series of simulated low-activity waste (LAW) glasses fabricated at the Pacific Northwest National Laboratory (PNNL). These data will be used in the development of improved property/composition models for LAW glass at Hanford. Chemical analyses were performed on a representative sample of each of the quenched and sulfur saturated glasses to allow for comparisons with the targeted compositions. For some of the quenched glasses, measured concentrations of Cr 2 O 3 , K 2 O, Na 2 O, P 2 O 5 , and ZrO 2 were below the targeted values. For some of the sulfur saturated glasses, the measured concentrations of Al 2 O 3 , Cl - , Cr 2 O 3 , F - , K 2 O, Na 2 O, P 2 O 5 , V 2 O 5 , and ZrO 2 were generally low relative to the targeted values. A comparison of the measured compositions of the quenched and sulfur saturated versions of the study glasses showed that the measured concentrations of Al 2 O 3 , Cl - , and F - were lower for most of the sulfur saturated glasses. The measured Cr 2 O 3 and K 2 O concentrations were markedly lower for the sulfur saturated versions of the glasses as compared to the quenched versions, which may indicate that these elements partitioned to the soluble sulfur salts. A set of modified glasses was received from PNNL later in this study. Chemical analysis showed that these glasses generally met their targeted compositions. The measured SO 3 concentrations were higher for most of the sulfur saturated glasses relative to those of the quenched versions, as expected. Chemical analysis of the wash solutions that resulted from preparation of the sulfur saturated melts identified Cr, K, Na, P, S, and V as the major elements in solution. With the exception of sulfur, this may explain why the measured concentrations of these components in the study glasses were generally below the targeted values. PNNL performed PCTs on quenched and canister centerline cooled (CCC) versions of the study glasses, as well as the modified glasses. The leachates were sent to SRNL for chemical analysis. Minor scatter in the measured values among the triplicate samples for each glass was noted, with significant differences among the triplicate values noted for four of the CCC glasses. Normalized concentration values for some of the study glasses were greater than the 100 g/L maximum (total dissolution), which may indicate an error in the test. It is recommended that PNNL review the performance of the PCTs to determine the cause of these potential outliers and errors. Revision 1 of this report: Corrects an issue with high chromium measurements for the Mod glass compositions and the second set of PCT leachates, Adds data for the Mod glass wash solutions that were unintentionally omitted, Corrects an issue with rounding of the targeted Al 2 O 3 concentrations in the study glasses

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantitative phase analysis of challenging samples using neutron powder diffraction. Sample #4 from the CPD QPA round robin revisited

Here, quantitative phase analysis (QPA) using neutron powder diffraction more often than not involves non-ambient studies where no sample preparation is possible. The larger samples and penetration of neutrons versus X-rays makes neutron diffraction less susceptible to inhomogeneity and large grain sizes, but most well-characterized QPA standard samples do not have these characteristics. Sample #4 from the International Union of Crystallography Commission on Powder Diffraction QPA round robin was one such sample. Data were collected using the POWGEN time-of-flight (TOF) neutron powder diffractometer and analysed together with historical data from the C2 diffractometer at Chalk River. The presence of magnetic reflections from Fe 3 O 4 (magnetite) in the sample was an additional consideration, and given the frequency at which iron-containing and other magnetic compounds are present during in-operando studies their possible impact on the accuracy of QPA is of interest. Additionally, scattering from thermal diffuse scattering in the high- Q region (<0.6 Å) accessible with TOF data could impact QPA results during least-squares because of the extreme peak overlaps present in this region. Refinement of POWGEN data was largely insensitive to the modification of longer d -spacing reflections by magnetic contributions, but the constant-wavelength data were adversely impacted if the magnetic structure was not included. A robust refinement weighting was found to be effective in reducing quantification errors using the constant-wavelength neutron data both where intensities from magnetic reflections were ignored and included. Results from the TOF data were very sensitive to inadequate modelling of the high- Q (low d -spacing) background using simple polynomials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How Should Machine Learning Be Successfully Used for Wind Speed Vertical Extrapolation?

An accurate characterization of the wind resource available at hub-height is required for an efficient and bankable wind farm project. However, direct measurement of wind speed at the constantly increasing height of the hub of commercial wind turbines is oftentimes challenging and expensive, so that it is common practice to vertically extrapolate the wind resource from lower and more easily accessible levels. Conventional techniques for wind speed vertical extrapolation include the use of a power law and a logarithmic profile. While simple, the limits in accuracy of these methods have been shown in various studies. Recently, machine learning has been proposed as a new method to vertically extrapolate winds. All the published studies on the topic assess the performance of machine learning techniques in vertically extrapolating the wind resource at the same location where the algorithm has been trained. However, in real-world applications, the wind resource is measured at the instrument location, but it then needs to be extrapolated at hub height at the location of the wind turbines within the find farm. To be able to fully recommend the use of machine learning techniques over the simple power law and logarithmic law, the spatial variability of the performance improvements of the machine learning approaches needs to be assessed. Here, we propose a round-robin validation of a machine learning-based method for wind speed extrapolation. We use 20 months of observations at four locations spanning a 100 km wide region at the Southern Great Plains (SGP) atmospheric observatory, in north-central Oklahoma. At each location, we train a random forest to predict 30-min average wind speed at 143 m AGL. We use as input features lidar wind speed at 65 m AGL, time of day, sonic anemometer wind speed at 4 m AGL, turbulent kinetic energy, and Obukhov length. First, we perform a same-site comparison of the performance of the proposed random forest against the conventional techniques for wind speed extrapolation (namely power law and logarithmic profile, with widely accepted stability corrections). We find that the random forest outperforms the power law in vertically extrapolating wind speed in all the considered stability regimes, with a 33% reduction in MAE for stable conditions, and a 31% reduction in unstable conditions. Similar results are found when comparing predictions of extrapolated winds from the logarithmic profile and the random forest with the observed values. Next, we propose a round-robin validation, to use the random forest trained at each site to extrapolate wind speed at the remaining three sites. We find that the performance of the random forest approach degrades when the algorithm is tested at a site different than the training one. However, even under those circumstances, the machine learning-based approach still outperforms the conventional techniques for wind speed extrapolation, with, on average, a reduction in mean absolute error between 15 and 20% over the conventional methods, with the largest benefits obtained under stable conditions.

Monte Carlo↗

MONTE-CARLO BURNUP CALCULATION UNCERTAINTY QUANTIFICATION AND PROPAGATION DETERMINATION

MONTEBURNS is a Monte-Carlo depletion routine utilizing MCNP and ORIGEN 2.2. Uncertainties exist in the MCNP transport calculation, but this information is not passed to the depletion calculation in ORIGEN or saved. To quantify this transport uncertainty and determine how it propagates between burnup steps, a statistical analysis of a multiple repeated depletion runs is performed. The reactor model chosen is the Oak Ridge Research Reactor (ORR) in a single assembly, infinite lattice configuration. This model was burned for a 25.5 day cycle broken down into three steps. The output isotopics as well as effective multiplication factor (k-effective) were tabulated and histograms were created at each burnup step using the Scott Method to determine the bin width. It was expected that the gram quantities and k-effective histograms would produce normally distributed results since they were produced from a Monte-Carlo routine, but some of results do not. The standard deviation at each burnup step was consistent between fission product isotopes as expected, while the uranium isotopes created some unique results. The variation in the quantity of uranium was small enough that, from the reaction rate MCNP tally, round off error occurred producing a set of repeated results with slight variation. Statistical analyses were performed using the {chi}{sup 2} test against a normal distribution for several isotopes and the k-effective results. While the isotopes failed to reject the null hypothesis of being normally distributed, the {chi}{sup 2} statistic grew through the steps in the k-effective test. The null hypothesis was rejected in the later steps. These results suggest, for a high accuracy solution, MCNP cell material quantities less than 100 grams and greater kcode parameters are needed to minimize uncertainty propagation and minimize round off effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-G-TeP4-11: Implementation of a Non-Measurement-Based Patient-Specific IMRT QA Program

Purpose: To implement a comprehensive non-measurement-based verification program for patient-specific IMRT QA Methods: Based on published guidelines, a robust IMRT QA program should assess the following components: 1) accuracy of dose calculation, 2) accuracy of data transfer from the treatment planning system (TPS) to the record-and-verify (RV) system, 3) treatment plan deliverability, and 4) accuracy of plan delivery. Results: We have implemented an IMRT QA program that consist of four components: 1) an independent re-calculation of the dose distribution in the patient anatomy with a commercial secondary dose calculation program: Mobius3D (Mobius Medical Systems, Houston, TX), with dose accuracy evaluation using gamma analysis, PTV mean dose, PTV coverage to 95%, and organ-at-risk mean dose; 2) an automated in-house-developed plan comparison system that compares all relevant plan parameters such as MU, MLC position, beam iso-center position, collimator, gantry, couch, field size settings, and bolus placement, etc. between the plan and the RV system; 3) use of the RV system to check the plan deliverability and further confirm using “mode-up” function on treatment console for plans receiving warning; and 4) implementation of a comprehensive weekly MLC QA, in addition to routine accelerator monthly and daily QA. Among 1200 verifications, there were 9 cases of suspicious calculations, 5 cases of delivery failure, no data transfer errors, and no failure of weekly MLC QA. These 9 suspicious cases were due to the PTV extending to the skin or to heterogeneity correction effects, which would not have been caught using phantom measurement-based QA. The delivery failure was due to the rounding variation of MLC position between the planning system and RV system. Conclusion: A very efficient, yet comprehensive, non-measurement-based patient-specific QA program has been implemented and used clinically for about 18 months with excellent results.

60 APPLIED LIFE SCIENCES↗

Advanced Graphite Creep Uncertainty Analysis

Radiation damage estimation is an important component of the post irradiation analysis of the Advanced Graphite Creep (AGC) experiment. It depends primarily on the fast fluence, which is determined using well established methods of spectral adjustment. These are based on best estimates from models such as Monte Carlo N-Particle (MCNP), input cross-sections, and measured activities from flux wires in the experiment. Each of these parameters can propagate uncertainties which will affect the uncertainty in the calculated dose levels for AGC, or any experiment irradiated within a reactor. While the methods of propagating uncertainty are well-established, the final uncertainty estimates they provide are only as good as the estimates of uncertainty in the inputs on which they are based. The purpose of this work is to outline some deficiencies in the ways these input uncertainties are presently estimated, and to outline a methodology by which they can be improved. The fast fluence and radiation damage received by graphite specimens irradiated in the Advanced Graphite Creep (AGC) experiments is presently estimated using spectral adjustment methods that are based on both flux wire activity measurements, and MCNP model predictions. This work describes an ongoing effort to quantify and propagate uncertainties in inputs to the spectral adjustment process, and thereby quantify the resultant error in radiation damage (dpa) estimates. The effort is multi-faceted, and we consider the impacts of both the set of flux wires selected, and the counting process. An expanded set of flux wires is identified that provides a more comprehensive data set on the fast spectrum. To address the counting process itself, a series of round-robin measurements in several reactor metrology laboratories across the Department of Energy (DOE) complex and nuclear industry are being undertaken to refine the American Society for Testing and Materials (ASTM) standards for flux wire measurements. To address the contribution of uncertainty in the MCNP model predictions, an uncertainty quantification (UQ) tool has been developed that statistically samples the model input parameters, runs a series of cases, and assimilates the results to provide an overall uncertainty. The impact of the MCNP UQ tool results is demonstrated by re-analyzing previous AGC flux wire and irradiation data. While the expanded flux wire set obviously cannot be added to these experiments retroactively, plans for future graphite irradiations are outlined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

3D-printed sheet jet for stable megahertz liquid sample delivery at X-ray free-electron lasers

X-ray free-electron lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit involves the delivery of samples to the X-ray interaction point in such a way that produces data of the highest possible quality and with maximal efficiency. This is hampered by intrinsic constraints posed by the light source and operation within a beamline environment. For liquid samples, the solution typically involves some form of high-speed liquid jet, capable of keeping up with the rate of X-ray pulses. However, conventional jets are not ideal because of radiation-induced explosions of the jet, as well as their cylindrical geometry combined with the X-ray pointing instability of many beamlines which causes the interaction volume to differ for every pulse. This complicates data analysis and contributes to measurement errors. An alternative geometry is a liquid sheet jet which, with its constant thickness over large areas, eliminates the problems related to X-ray pointing. Since liquid sheets can be made very thin, the radiation-induced explosion is reduced, boosting their stability. These are especially attractive for experiments which benefit from small interaction volumes such as fluctuation X-ray scattering and several types of spectroscopy. Although their use has increased for soft X-ray applications in recent years, there has not yet been wide-scale adoption at XFELs. Here, gas-accelerated liquid sheet jet sample injection is demonstrated at the European XFEL SPB/SFX nano focus beamline. Its performance relative to a conventional liquid jet is evaluated and superior performance across several key factors has been found. This includes a thickness profile ranging from hundreds of nanometres to 60 nm, a fourfold increase in background stability and favorable radiation-induced explosion dynamics at high repetition rates up to 1.13 MHz. Its minute thickness also suggests that ultrafast single-particle solution scattering is a possibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-A-BRC-00: New Task Groups for External Beam QA: An Overview

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗

TH-A-BRC-01: AAPM TG-135U1 QA for Robotic Radiosurgery

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗